Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPULSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Pressurization and expulsion of a flightweight liquid hydrogen tank

Experimental results are presented for pressurization and expulsion of a flight-weight 4.89 cu m liquid hydrogen storage tank under normal gravity conditions. Pressurization and expulsion times are parametrically varied to study the effects of longer transfer times expected in future space flight applications. It is found that the increase in pressurant consumption with increased operational time is significant at shorter pressurization or expulsion durations and diminishes as the duration lengthens. Gas-to-wall heat transfer in the ullage is the dominant mode of energy exchange, with more than 50 percent of the pressurant energy being lost to tank wall heating in expulsions and the long duration pressurizations. Advanced data analysis will require a multidimensional approach combined with improved measurement capabilities of liquid-vapor interfacial transport phenomena.

Vandresar, N. T.↗

Flux Expulsion and Material Properties of Niobium Explored in 644-650 MHz Cavities

Upcoming projects requiring high-Q ~650 MHz medium-to-high-${\beta}$ elliptical cavities drive a need to understand magnetic RF loss mechanisms and mitigations in greater detail. High-temperature annealing and fast-cooldowns have proven effective techniques for promoting magnetic flux expulsion in cavities, however the extent of their effectiveness has been observed to vary between niobium material lot and vendor. We explore the fast-cooldown method, and high-temperature annealing (900{\deg}C) in 644-650 MHz cavities fabricated from two different niobium vendors: Tokyo-Denkai, and Ningxia. which promote flux-expulsion efficiency. Using EBSD and PPMS methods, we aim to trace cavity flux expulsion efficiency to specific, measurable properties of the bulk niobium material, which, if identified, can lead to methods by which the flux expulsion properties of Nb material can be predicted prior to cavity fabrication, and can enable fine-tuning of cavity temperature treatments.

43 PARTICLE ACCELERATORS↗

Identifying the connections between grain growth and flux expulsion in low RRR niobium SRF cavities

The SRF community has shown that high temperature annealing can improve the flux expulsion of niobium cavities during cooldown. The required temperature will vary between cavities and different batches of material, typically around 800 C and up to 1000 C. However, for niobium with a low residual resistance ratio (RRR), even 1000 C is not enough to improve its poor flux expulsion. The purpose of this study is to observe the grain growth behavior of low RRR niobium coupons subjected to high temperature annealing to identify the mechanism for improving flux expulsion. We observe that low RRR material experiences less grain growth than high RRR when annealed at the same temperature. We search for the limitations to grain growth in low RRR material and develop a diagnostic based on grain structure to determine the appropriate recipe for good flux expulsion. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

Howard, K. [Chicago U.] (ORCID:0000000325613308)↗

Role of microstructure on flux expulsion of superconducting radio frequency cavities

The trapped residual magnetic flux during the cool-down due to the incomplete Meissner state is a significant source of radio frequency losses in superconducting radio frequency cavities. Here, in this study, we clearly correlate the niobium microstructure in elliptical cavity geometry and flux expulsion behavior. In particular, a traditionally fabricated Nb cavity half-cell from an annealed poly-crystalline Nb sheet after an 800 °C heat treatment leads to a bi-modal microstructure that ties in with flux trapping and inefficient flux expulsion. This non-uniform microstructure is related to varying strain profiles along the cavity shape. A novel approach to prevent this non-uniform microstructure is presented by fabricating a 1.3 GHz single cell Nb cavity with a cold-worked sheet and subsequent heat treatment leading to better flux expulsion after 800 °C/3 h. Microstructural evolution by electron backscattered diffraction-orientation imaging microscopy on cavity cutouts, and flux pinning behavior by dc-magnetization on coupon samples confirms a reduction in flux pinning centers with increased heat treatment temperature. The heat treatment temperature-dependent mechanical properties and thermal conductivity are reported. The significant impact of cold work in this study demonstrates clear evidence for the importance of the microstructure required for high-performance superconducting cavities with reduced losses caused by magnetic flux trapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Iodine (I) Expulsion at Photoirradiated Mixed Halide Perovskite Interface. Should I Stay or Should I Go?

Visible light irradiation of the mixed halide perovskite film in contact with a solvent (dichloromethane, DCM) in which the film otherwise is stable, leads to selective expulsion of iodide (I) from the film with concurrent shift in the band edge to lower wavelengths. Here we have now employed mixed halide perovskites to uncover the influence of A-site cation (Methyl ammonium, MA and Cesium, Cs) on the mobility of iodide ions under photoirradiation. In the absence of solvent contact, the mixed halide perovskite films undergo photoinduced segregation with a rate constant that decreases with increasing Cs content. Interestingly, the iodide expulsion rate in DCM is strongly dependent on the rate of photoinduced segregation. At Cs atomic concentrations higher than 50%, the films become stable as the iodide expulsion is largely suppressed. The role of A-site cation in dictating the mobility of halide ions is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetic Flux Expulsion Studies in Niobium SRF Cavities

With the recent discovery of nitrogen doping treatment for SRF cavities, ultra-high quality factors at medium accelerating fields are regularly achieved in vertical RF tests. To preserve these quality factors into the cryomodule, it is important to consider background magnetic fields, which can become trapped in the surface of the cavity during cooldown and cause Q₀ degradation. Building on the recent discovery that spatial thermal gradients during cooldown can significantly improve expulsion of magnetic flux, a detailed study was performed of flux expulsion on two cavities with different furnace treatments that are cooled in magnetic fields amplitudes representative of what is expected in a realistic cryomodule. In this contribution, we summarize these cavity results, in order to improve understanding of the impact of flux expulsion on cavity performance.

43 PARTICLE ACCELERATORS↗

MATERIAL QUALIFICATION OF LCLS-II PRODUCTION NIOBIUM MATERIAL INCLUDING RF AND FLUX EXPULSION MEASUREMENTS ON SINGLE CELL CAVITIES

It has been shown that cooldown details through transition temperature can significantly affect the amount of trapped magnetic flux in SRF cavities, which can lead to performance degradation proportional to the magnitude of the ambient magnetic field.1 It has also more recently been shown that depending on the exact material properties - even when the material used originated from the same batch from the same vendor - and subsequent heat treatment, the percent of flux trapped during a cool-down could vary widely for identical cool-down parameters.2 For LCLS-II, two material vendors have produced half of the niobium used for the cavity cells (Tokyo Denkai Co., Ltd. (TD) and Ningxia Orient Tantalum Industry Co., Ltd. (NX)). Both vendors delivered material well within specifications set out by the project (according to ASTM B 393-05), which allows yet some variation of material characteristics such as grain size and defect density. In this contribution, we present RF and magnetic flux expulsion measurements of four single cell cavities made out of two different niobium batches from each of the two LCLS-II material suppliers and draw conclusions on potential correlations of flux expulsion capability with material parameters. We present observations of limited flux expulsion in cavities made from the production material and treated with the baseline LCLS-II recipe.

Palczewski, Ari↗

Flux Expulsion Testing for LCLS-II-HE Cavity Production

Nitrogen-doped niobium SRF cavities are sensitive to trapped magnetic flux, which decreases the cavity intrinsic Q₀. Prior experimental results have shown that heat treatments to 900°C and higher can result in stronger flux expulsion during cooldown; the precise temperature required tends to vary by vendor lot/ingot of the niobium material used in the cavity cells. For LCLS-II-HE, to ensure sufficient flux expulsion in all cavities, we built and tested single-cell cavities to determine this required temperature for each vendor lot of niobium material to be used in cavity cells. In this report, we present the results of the single-cell flux expulsion testing and the Q₀ of the nine-cell cavities built using the characterized vendor lots. We discuss mixing material from different vendor lots, examine the lessons learned, and finally present an outlook on possible refinements to the single-cell technique.

43 PARTICLE ACCELERATORS↗

The Path to High Q-Factors in Superconducting Accelerating Cavities: Flux Expulsion and Surface Resistance Optimization

Accelerating cavities are devices resonating in the radio-frequency (RF) range used to accelerate charged particles in accelerators. Superconducting accelerating cavities are made out of niobium and operate at the liquid helium temperature. Even if superconducting, these resonating structures have some RF driven surface resistance that causes power dissipation. In order to decrease as much as possible the power losses, the cavity quality factor must be increased by decreasing the surface resistance. In this dissertation, the RF surface resistance is analyzed for a large variety of cavities made with different state-of-the-art surface treatments, with the goal of finding the surface treatment capable to return the highest Q-factor values in a cryomodule-like environment. This study analyzes not only the superconducting properties described by the BCS surface resistance, which is the contribution that takes into account dissipation due to quasi-particle excitations, but also the increasing of the surface resistance due to trapped flux. When cavities are cooled down below their critical temperature inside a cryomodule, there is always some remnant magnetic field that may be trapped increasing the global RF surface resistance. This thesis also analyzes how the fraction of external magnetic field, which is actually trapped in the cavity during the cooldown, can be minimized. This study is performed on an elliptical single-cell horizontally cooled cavity, resembling the geometry of cavities cooled in accelerator cryomodules. The horizontal cooldown study reveals that, as in case of the vertical cooldown, when the cooling is performed fast, large thermal gradients are created along the cavity helping magnetic flux expulsion. However, for this geometry the complete magnetic flux expulsion from the cavity equator is more difficult to achieve. This becomes even more challenging in presence of orthogonal magnetic field, that is easily trapped on top of the cavity equator causing temperature rising. The physics behind the magnetic flux expulsion is also analyzed, showing that during a fast cooldown the magnetic field structures, called vortices, tend to move in the same direction of the thermal gradient, from the Meissner state region to the mixed state region, minimizing the Gibbs free energy. On the other hand, during a slow cool down, not only the vortices movement is limited by the absence of thermal gradients, but, also, at the end of the superconducting transition, the magnetic field concentrates along randomly distributed normal-conducting region from which it cannot be expelled anymore. The systematic study of the surface resistance components performed for the different surface treatments, reveals that the BCS surface resistance and the trapped flux surface resistance have opposite trends as a function of the surface impurity content, defined by the mean free path. At medium field value, the BCS surface resistance is minimized for nitrogen-doped cavities and significantly larger for standard niobium cavities. On the other hand, Nitrogen-doped cavities show larger dissipation due to trapped flux. This is consequence of the bell-shaped trend of the trapped flux sensitivity as a function of the mean free path. Such experimental findings allow also a better understanding of the RF dissipation due to trapped flux. The best compromise between all the surface resistance components, taking into account the possibility of trapping some external magnetic field, is given by light nitrogen-doping treatments. However, the beneficial effects of the nitrogen-doping is completely lost when large amount of magnetic field is trapped during the cooldown, underlying the importance of both cooldown and magnetic field shielding optimization in high quality factors cryomodules.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Oscillatory phase separation during expulsion of daughter GUVs

A video assembled from time-lapse fluorescence images of phase-separating GUVs containing internal ‘organelle’ vesicles. GUVs consisting of POPC:SM:Ch (2:2:1) labeled with 0.5 mol% Sphingomyelin-Atto647N (SM-647N) (pseudo-colored green), encapsulate 1 M sucrose, and diluted in MilliQ water at 25°C. The video reveals shifting patterns of osmotic pressure and tension during expulsion of the internal vesicles after an osmotic differential had been established. Key steps include (A) a homogeneous, flaccid mother vesicle encapsulating tense daughter vesicles, at a time point prior to vesicle expulsion; (B) just after expulsion, the daughter GUV remains tense exhibiting oscillatory phase separation, while the mother GUV is left deflated and homogenous due to the sudden loss of volume; (C) The mother GUV subsequently becomes inflated by influx of water; and (D) the mother GUV begins to exhibit oscillatory phase separation.

59 BASIC BIOLOGICAL SCIENCES↗

Metallic positive expulsion diaphragms

High-cycle life ring-reinforced hemispherical type positive expulsion diaphragm performance was demonstrated by room temperature fluid expulsion tests of 13" diameter, 8 mil thick stainless steel configurations. A maximum of eleven (11) leak-free, fluid expulsions were achieved by a 25 deg cone angle diaphragm hoop-reinforced with .110-inch cross-sectional diameter wires. This represents a 70% improvement in diaphragm reversal cycle life compared to results previously obtained. The reversal tests confirmed analytic predictions for diaphragm cycle life increases due to increasing values of diaphragm cone angle, radius to thickness ratio and material strain to necking capacity. Practical fabrication techniques were demonstrated for forming close-tolerance, thin corrugated shells and for obtaining closely controlled reinforcing ring stiffness required to maximize diaphragm cycle life. A non-destructive inspection technique for monitoring large local shell bending strains was developed.

Gleich, D.↗

An experimental evaluation of metallic diaphragms for positive fuel expulsion in the Atmosphere Explorer, hydrazine propulsion subsystem

Four Arde conospheroid metallic diaphragms were tested at NASA to evaluate their capability for use in the orbit adjust propulsion subsystem (OAPS) of the Atmosphere Explorer spacecraft (AE's C, D, and E). The diaphragms will be used for positive propellant expulsion and spacecraft center of mass (c.m.) control. A leak-free cycle life capability of nine reversals was demonstrated. The diaphragms rolled smoothly from ring to ring in a predictable manner on the first reversal. Varying amounts of diaphragm cocking and ring skipping were observed on subsequent reversals. The diaphragm pressure differential did not exceed 10 psid during any reversal. Cycle life capability, reversal mode, and pressure differential were not affected by sudden reversals, environmental tests, or 18,000 partial reversals. An expulsion efficiency of approximately 97 percent was demonstrated. The results of these tests show that metallic diaphragms can be used as an effective means of positive fuel expulsion; however, to achieve spacecraft c.m. control, the diaphragm must not be reversed prior to flight.

Woodruff, W. L.↗

An experimental evaluation of metallic diaphragms for positive fuel expulsion in the atmosphere explorer hydrazine propulsion subsystem

Four Arde conospheroid metallic diaphragms were tested to evaluate their capability for use in the orbit adjust propulsion subsystem (OAPS) of the Explorer spacecraft. The diaphragms will be used for positive propellant expulsion and spacecraft center of mass control. A leak-free cycle life capability of nine reversals was demonstrated. The diaphragms rolled smoothly from ring to ring in a predictable manner on the first reversal. Varying amounts of diaphragm cocking and ring skipping were observed on subsequent reversals. The diaphragm pressure differential did not exceed 7 N/sq cm during any reversal. Cycle life capability, reversal mode, and pressure differential were not affected by sudden reversals, environmental tests, or 18,000 partial reversals. An expulsion efficiency of approximately 97 percent was demonstrated. The results of these tests show that metallic diaphragms can be used as an effective means of positive fuel expulsion; however, to achieve spacecraft center of mass control, the diaphragm must not be reversed prior to flight.

Woodruff, W. L.↗

Space Shuttle solid rocket motor slag expulsion mechanisms

A 13 psi pressure perturbation occurred at approximately 68 seconds on the right Redesigned Solid Rocket Motor (RSRM) during the STS-54 space shuttle mission. While pressure perturbations are a normal characteristic of RSRM operation, the magnitude of the STS-54 perturbation and the resulting thrust imbalance between the left and right motors was outside of flight experience. A joint Marshall Space Flight Center (MSFC) and Thiokol Corporation (RSRM manufacturer) team soon narrowed the probable cause to a temporary nozzle restriction due to slag expulsion. In support of the team, Rockwell Aerospace performed fluid finite element simulations and vehicle flight dynamic correlations to investigate possible slag expulsion mechanisms responsible for pressure perturbations. Results of the simulations and analyses provided evidence that the combination of flight induced accelerations acting on accumulated slag and nozzle vectoring were the most probable cause of RSRM slag expulsion.

Hopson, Charles B.↗

Validation of a Two-Phase CFD Model for Autogenous Pressurization and Expulsion

This paper presents a two-phase computational fluid dynamics (CFD) model for simulating autogenous pressurization and expulsion in a cryogenic liquid hydrogen storage tank, utilizing a volume-of-fluid (VOF) approach combined with the kinetics-based Schrage equation to accurately capture the phase boundary and interfacial heat, mass, and momentum transfer between liquid and vapor phases. The model is validated against experimental data from NASA's K-site tank facility, specifically experimental case 225, which involved pressurization and controlled expulsion of liquid hydrogen. Various turbulence models are evaluated to assess their influence on model accuracy. The CFD simulations successfully replicate key thermodynamic behaviors observed during the experiments, including pressure evolution, temperature profiles, and phase-change dynamics at the vapor-liquid interface. The predicted tank pressures, temperatures, and pressurant requirements agree with experimental data, with pressurant mass predictions within 16\% of observed values. This study highlights the importance of selecting appropriate turbulence models to accurately simulate complex flow and heat transfer phenomena during tank pressurization and expulsion. By enhancing the accuracy and reliability of CFD models for liquid hydrogen under cryogenic conditions, this research contributes to developing efficient cryogenic propellant management strategies for future space missions.

Computational Fluid Dynamics↗

Validation of a Two-Phase CFD Model for Autogenous Pressurization and Expulsion

This paper presents a two-phase computational fluid dynamics (CFD) model for simulating autogenous pressurization and expulsion in a cryogenic liquid hydrogen storage tank, utilizing a volume-of-fluid (VOF) approach combined with the kinetics-based Schrage equation to accurately capture the phase boundary and interfacial heat, mass, and momentum transfer between vapor and liquid phases. The model is validated against experimental data from NASA's K-site tank facility, specifically experimental case 225, which involved autogenous pressurization and controlled expulsion of liquid hydrogen. Various turbulence models are evaluated to assess their influence on model accuracy. The CFD simulations successfully replicate key thermodynamic behaviors observed during the experiments, including pressure evolution, temperature profiles, and phase-change dynamics at the vapor-liquid interface. The predicted tank pressures and temperatures agree well with experimental data, whereas the pressurant mass predictions are within 16% of observed values. This study emphasizes the importance of selecting appropriate turbulence models to accurately simulate the complex flow and heat transfer phenomena during tank autogenous pressurization and expulsion. By improving the accuracy and reliability of CFD models for these processes, this research contributes to developing efficient cryogenic propellant management strategies for future space missions.

Computational Fluid Dynamics↗

Optimal Thermal Gradient for Flux Expulsion in 600°C Heat-treated CEBAF 12 GeV Upgrade Cavities

We will present results on measurement of flux expulsion in CEBAF 12 GeV upgrade cavities and original CEBAF cavities and the search for optimal thermal gradient for reducing the trapped flux in cavities installed in CEBAF linacs. Preliminary measurements of one C100 cavities has shown that a nearly perfect flux expulsion can be achieved at an optimal thermal gradient - a surprising result contrary to the expectation of zero flux expulsion for 600°C heat treated niobium cavities. These results could lead to a cost-effective path for improving the quality factor of cavities installed in CEBAF and ultimately saving accelerator operation cost.

Geng, R.↗

AMR Magnetic Sensors in Flux Expulsion Studies

Magnetic flux expulsion properties of the superconducting material such as bulk niobium, widely used for the radio-frequency cavity fabrication, substantially affect the performance characteristics of the cavities. The quality factor of the SRF resonators can be significantly compromised due to the presence of the trapped flux vortices causing additional RF energy losses in the material. Large number of experiments have been carried out by different research groups to establish the correlation of the flux trapping in niobium cavities with the presence of impurities in niobium as well as various surface treatment methods. Majority of these experiments utilize commercially available cryogenic fluxgate magnetic sensors to measure the field before and after the niobium transition to the superconducting state to quantify the amount of flux trapped. One disadvantage of the typically used fluxgates is the size of the sensing volume. As an example, the Barting-ton F and G type cryogenic fluxgates have a sensing core length of about 30mm, which is comparable to the curvature radius of the cavity walls and hence the magnetic field lines curvature radius after the expulsion. Thus, the measured field value needs to be corrected to account for the sensor effective averaging over the sensing volume. In case of the sharper geometries, for instance if the flux expulsion to be measured on the edge of the rectangular niobium flat sheet with a thickness of ~5mm, the use of the fluxgate would be impractical.

Netepenko, A.↗