Detoxification of Halon Fire-Extinguishant Products

Ammonia compounds absorb toxic hydrogen halides as they are produced. Toxic acid vapors resulting from use of Halon (or equivalent) fire extinguishers immediately changed into nontoxic ammonium compounds when extinguishers contain some ammonia or ammonium carbonate. If ammonium carbonate used, particle size of resulting neutral compounds controlled to eliminate virtually any absorption into the lungs.

Miller, E. L.↗

Powder Extinguishants for Jet-Fuel Fires

Mixtures of alkali metal dawsonite and metal halide show superior performance. In tests of new dry powder fire extinguishants, mixtures of potassium dawsonite with either stannous iodide or potassium iodide found effective for extinguishing jet-fuel fires on hot metal surfaces (up to 900 degrees C). Mixtures performed more effectively than either compound alone.

Altman, R. L.↗

Extinguishment of a Diffusion Flame Over a PMMA Cylinder by Depressurization in Low-Gravity

The behavior of flames in low-speed flows in low-gravity is relevant to spacecraft fire safety. Previous work has shown that flames in the presence of low-speed forced flows in low-gravity may be more flammable than in a forced flow of the same magnitude in normal gravity. Additionally, fire suppression plans for the International Space Station include the use of venting (depressurization) as an emergency option for extinguishing fires. This procedure would induce flows in the affected compartment that could temporarily intensify the fire, as was observed in flammability tests of solids conducted on board Skylab. Despite a general Understanding, current knowledge of the combined effects of reduced pressure and forced flow on a burning solid in low-gravity is inadequate for the design of a venting extinguishment system. Previous studies in low-g have examined flammability limits for thermally thin solids. However, there are differences when burning thick materials because the interior solid-phase temperature continuously changes, which affects the percentage of gas-phase heat feedback to the solid-phase. Changes in the heat feedback to the solid-phase can affect the flammability characteristics of the material. In the current work, the extinction of a diffusion flame burning over PMMA (polymethyl methacrylate) cylinders during depressurization with a low-speed cross flow was examined experimentally and via numerical simulations.

Goldmeer, Jeffrey S.↗

Adsorption of Halogenated Fire-Extinguishing Agents on Powders

The amounts of four different Freons adsorbed by carbon, silica gel, alumina, and molecular sieves were determined at pressures up to 225 lb/sq in. The carbon adsorbed 50 to 100 percent and the silica gels, 30 to 50 percent of their own weight of Freon. Several adsorbed systems were tested in a standard dry-powder extinguisher on a 5-sq-ft gasoline fire for their effectiveness in putting out a fire. One of the Freons (bromotrifluoromethane) and carbon extinguished fires about as well as bicarbonate powder and nitrogen.

Barduhn, Allen J.↗

SEM Characterization of Extinguished Grains from Plasma-Ignited M30 Charges

M30 propellant grains that had been ignited in interrupted closed bomb experiments were characterize by scanning electron microscopy (SEM). Previous chemical analysis of extinguished grains had given no indications of plasma-propellant chemical interactions that could explain the increased burning rates that had been previously observed in full-pressure closed bomb experiments. (This does not mean that there is no unique chemistry occurring with plasma ignition. It may occur very early in the ignition event and then become obscured by the burning chemistry.) In this work, SEM was used to look at grain morphologies to determine if there were increases in the surface areas of the plasma-ignited grains which would contribute to the apparent increase in the burning rate. Charges were made using 30 propellant grains (approximately 32 grams) stacked in two tiers and in two concentric circles around a plastic straw. Each grain was notched so that, when the grains were expelled from the bomb during extinguishment, it could be determined in which tier and which circle each grain was originally packed. Charges were ignited in a closed bomb by either a nickel wire/Mylar-capillary plasma or black powder. The bomb contained a blowout disk that ruptured when the pressure reached 35 MPa, and the propellant was vented into a collection chamber packed with polyurethane foam. SEM analysis of the grains fired with a conventional black powder igniter showed no signs of unusual burning characteristics. The surfaces seemed to be evenly burned on the exteriors of the grains and in the perforations. Grains that had been subjected to plasma ignition, however, had pits, gouges, chasms, and cracks in the surfaces. The sides of the grains closest to the plasma had the greatest amount of damage, but even surfaces facing the outer wall of the bomb had small pits. The perforations contained gouges and abnormally burned regions (wormholes) that extended into the web. The SEM photos indicated that a grain from the top tier, which was farther away from the plasma ignition source, sustained more plasma-induced damage to the perforations and the web than did the grains on the bottom tier.

Kinkennon, A.↗

Space Experiment Concepts: Cup-Burner Flame Extinguishment

Space Fire Suppression Processes & Technology. Space experiment concepts of cup-burner flame extinguishment have been conceived to address to the key issues (i.e., organizing questions) in space fire suppression. Cup-burner flame extinguishment experiment can reveal physical and chemical suppression processes and provide agent effectiveness data useful for technology development of space fire suppression systems in various reduced-gravity platforms.

Takahashi, Fumiaki↗

Solid State Digital Propulsion "Cluster Thrusters" For Small Satellites Using High Performance Electrically Controlled Extinguishable Solid Propellants (ECESP)

Electrically controlled extinguishable solid propellants (ESCSP) are capable of multiple ignitions, extinguishments and throttle control by the application of electrical power. Both core and end burning no moving parts ECESP grains/motors to three inches in diameter have now been tested. Ongoing research has led to a newer family of even higher performance ECESP providing up to 10% higher performance, manufacturing ease, and significantly higher electrical conduction. The high conductivity was not found to be desirable for larger motors; however it is ideal for downward scaling to micro and pico- propulsion applications with a web thickness of less than 0.125 inch/ diameter. As a solid solution propellant, this ECESP is molecularly uniform, having no granular structure. Because of this homogeneity and workable viscosity it can be directly cast into thin layers or vacuum cast into complex geometries. Both coaxial and grain stacks have been demonstrated. Combining individual propellant coaxial grains and/or grain stacks together form three-dimensional arrays yield modular cluster thrusters. Adoption of fabless manufacturing methods and standards from the electronics industry will provide custom, highly reproducible micro-propulsion arrays and clusters at low costs. These stack and cluster thruster designs provide a small footprint saving spacecraft surface area for solar panels and/or experiments. The simplicity of these thrusters will enable their broad use on micro-pico satellites for primary propulsion, ACS and formation flying applications. Larger spacecraft may find uses for ECESP thrusters on extended booms, on-orbit refueling, pneumatic actuators, and gas generators.

Sawka, Wayne N.↗

Orion Portable Fire Extinguisher Performance Testing Against a Laptop Lithium-Ion Battery Stored-Energy Fire-Method, Magnesium Fires, and Combustion By-Product Toxicity

As part of the qualification of the International Space Station (ISS) fine water mist portable fire extinguisher (PFE), several test methods were developed to determine firefighting capability against stored-energy sources. The most challenging of these devised stored-energy fire test methods proved to be the Lithium-ion (Li-ion) battery fire test scenario. The Orion crew capsule will utilize a different PFE technology from ISS (water spray rather than water mist), which spurred the need for the same type of evaluation focused on the sources of stored energy slated for use on Orion. Laptops were identified as a realistic source for stored-energy fires, requiring a modified Li-ion battery fire test scenario. In addition to open test cell (ambient oxygen concentration) testing to evaluate new proposed PFE performance, sealed chamber (20.9% and elevated oxygen concentration) testing was also performed. Chamber testing included combustion product sampling at various fire progression points for analysis and application to Orion emergency equipment design and response planning. The PFE stored-energy fire test methodology was modified and testing performed. Initial tests indicated ignition of the laptop magnesium laptop cases was possible. Additional tests were performed to characterize the laptop magnesium case fire behavior in various configurations. The new water spray PFE technology proved effective in extinguishing laptop stored-energy fires, and much was learned in the way these types of fires progressed. Findings indicate potential laptop magnesium case ignition mitigation strategies need to be further investigated.

Harper, Susana A.↗

Problems of Fire Prevention and Extinguishment in Space Cabins

The problems of prevention and extinguishment of fires in space cabins are, except for a few specific situations, not much different from those at sea level or in aircraft conditions. The unusual atmospheric environment and limitations of space and firefighting equipment compound the general problem. The zero-gravity environment modifies firefighting procedures in a rather profound way and will be given detailed treatment in this report.

CHEMICAL EXTINGUISHER↗

Fire extinguishment in hypobaric and hyperbaric environments

Work that has been performed to provide information on the effects of various fire extinguishing agents in special atmospheres is discussed. Data used in the development of both equipment and techniques for manned spacecraft and related equipment are discussed. The equipment includes a hypobaric chamber suitable for low pressure use and a hyperbaric chamber for high pressure operation. The effectiveness of agents in weightless environment is also discussed.

Kimzey, J. H.↗