Search NASA⌕ Search

SEARCH · Search NASA

Results for “Efficient Exterior Walls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

34 records · Page 2

Fallout from the Shuttle Arm

Vadeko International, Inc., Mississauga, Ontario developed for the Canadian National Railways (CN) the Robotic Paint Application System. The robotic paint shop has two parallel paint booths, allowing simultaneous painting of two hopper cars. Each booth has three robots, two that move along wall-mounted rails to spray-paint the exterior, a third that is lowered through a hatch in the railcar's top to paint the interior. A fully computerized system controls the movement of the robots and the painting process. The robots can do in four hours a job that formerly took 32 hours. The robotic system applies a more thorough coating and CN expects that will double the useful life of its hoppers and improve cost efficiency. Human painters no longer have to handle the difficult and hazardous job. CN paint shop employees have been retrained to operate the computer system that controls the robots. In addition to large scale robotic systems, Vadeko International is engaged in such other areas of technology as flexible automation, nuclear maintenance, underwater vehicles, thin film deposition and wide band monitoring.

Source record↗

High-Performance Windows -- More than just a Pretty Hole in the Wall

As more stringent building energy codes and better insulation products combine to yield better performing walls, window efficiency is coming into sharper focus. The U.S. Department of Energy has supported several projects through its national laboratories to improve the thermal performance of windows. At Pacific Northwest National Laboratory (PNNL) in Richland, Washington, the PNNL Lab Homes, two fully monitored identical side-by-side manufactured homes, have been used to test the performance of several window improvements including triple-pane windows, storm windows with low-emissivity (low-e) coatings, smart automated interior insulated shades, and exterior shading products. Findings will be presented on these studies, along with impacts. For example, PNNL’s Lab Home research on low-e storm windows has helped to support a new ENERGY STAR certification, industry standards, and utility incentives. Preliminary findings will also be presented on current Lab Homes experiments focusing on exterior shades. The session will also present findings from related field studies and a market assessment of emerging high-efficiency windows technologies and discuss some of PNNL’s planned field studies that will focus on validating the benefits and costs of the emerging thin triple-pane high-R window.

windows, high-r windows, insulating windows, windo↗

Mitigating Moisture with High-R Walls

Energy-efficient building enclosures are key to decreasing energy load demand and enabling advanced space-conditioning systems for high-performance homes. One efficient enclosure design solution is high-R walls, which feature increased insulation levels as an effective solution for reducing air leakage and permeance of material layers. To increase builder confidence and encourage greater market adoption of high-R walls, Home Innovation Research Labs sought to demonstrate the long-term moisture performance of several high-R wall configurations in cold climate zones. The team monitored 22 newly constructed, occupied homes located throughout climate zones 4–7, where a substantial vapor drive to the exterior is present during the winter.

buildings↗

The Prediction of Ducted Fan Engine Noise Via a Boundary Integral Equation Method

A computationally efficient Boundary Integral Equation Method (BIEM) for the prediction of ducted fan engine noise is presented. The key features of the BIEM are its versatility and the ability to compute rapidly any portion of the sound field without the need to compute the entire field. Governing equations for the BIEM are based on the assumptions that all acoustic processes are linear, generate spinning modes, and occur in a uniform flow field. An exterior boundary value problem (BVP) is defined that describes the scattering of incident sound by an engine duct with arbitrary profile. Boundary conditions on the duct walls are derived that allow for passive noise control treatment. The BVP is recast as a system of hypersingular boundary integral equations for the unknown duct surface quantities. BIEM solution methodology is demonstrated for the scattering of incident sound by a thin cylindrical duct with hard walls. Numerical studies are conducted for various engine parameters and continuous portions of the total pressure field are computed. Radiation and duct propagation results obtained are in agreement with the classical results of spinning mode theory for infinite ducts.

Boundary integral equation↗

Efficient Fluid Dynamic Design Optimization Using Cartesian Grids

This report is subdivided in three parts. The first one reviews a new approach to the computation of inviscid flows using Cartesian grid methods. The crux of the method is the curvature-corrected symmetry technique (CCST) developed by the present authors for body-fitted grids. The method introduces ghost cells near the boundaries whose values are developed from an assumed flow-field model in vicinity of the wall consisting of a vortex flow, which satisfies the normal momentum equation and the non-penetration condition. The CCST boundary condition was shown to be substantially more accurate than traditional boundary condition approaches. This improved boundary condition is adapted to a Cartesian mesh formulation, which we call the Ghost Body-Cell Method (GBCM). In this approach, all cell centers exterior to the body are computed with fluxes at the four surrounding cell edges. There is no need for special treatment corresponding to cut cells which complicate other Cartesian mesh methods.

Dadone, A.↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

A Machine Learning-Assisted Framework to Control Thermally Anisotropic Building Envelopes in Residential Buildings

To curb the energy consumption of buildings and their related CO2 emissions, Oak Ridge National Laboratory (ORNL) has developed the thermally anisotropic building envelope (TABE) —a multi-layer design comprising insulation materials and metal foils connected to thermal loops. In this study, a machine learning-assisted framework was developed to control the TABE in residential buildings to reduce the computation load for future optimal rule-based control and application. First, a 2D finite element model was established in COMSOL to calculate the hourly heat flux through exterior walls installed with the TABE. Then, TABE wall heat fluxes were simulated for various given indoor and outdoor boundary conditions, as well as thermal loops fluid temperatures and flow rates. Since the finite element simulations are computationally expensive, an artificial neural network (ANN) was then trained to use as a proxy of the finite element (COMSOL) modeling. Finally, the trained ANN model was coupled with the EnergyPlus model to predict the energy consumption of a US Department of Energy prototype single-family house installed with the TABE. An optimal simple rule-based control was determined from predefined rules for a case study. The results demonstrate that the developed machine learning–assisted framework can reduce 99.9% of the computation time while efficiently managing residential building energy for installed TABE walls.

Shen, Zhenglai↗

Benefits Of Automated Construction And Energy Efficiency Measures In Modular Homes

This article builds on and adds to a Buildings XV publication that introduced the Transformative Efficiency and Automation in Modular Homes (TEAMH) project. The TEAMH project sought to develop a scalable solution for producing modular homes with 20-50% energy savings and similar cost relative to site-fabricated single-family home construction. A key aspect of the project was assessing the potential for labor cost reductions through automation-assisted construction using light gauge steel (LGS). To quantify the advantages of this approach, side-by-side comparisons were made between traditional wood-framed construction and automation-assisted LGS construction. This demonstration involved constructing one wood-framed wall and several LGS test walls, accompanied by a time-and-motion study. The results indicated that automation assistance could decrease construction time and associated labor costs by as much as 46%. High-performance envelope technologies for exterior insulation and air sealing were evaluated to compare modular homes with site-built homes that meet the International Energy Conservation Code (IECC). A key technology considered was vacuum insulation panels (VIPs) with fiberglass cores. Guarded hot box testing of multiple full-scale wall assemblies containing different combinations of exterior continuous insulation systems containing phenolic foam and VIPs. Testing on various full-scale wall assemblies revealed that, with LGS construction, cavity insulation had minimal impact on exterior wall performance. Omitting cavity insulation can reduce labor and material costs while streamlining manufacturing, as its installation is labor-intensive and not easily automated due to the need for precise placement around wiring and other internal components. Guarded hot box tests of multiple LGS test walls with foam and VIP-based exterior insulation systems achieved R-values of up to 31 hr-ft2-°F/Btu. Finally, building energy modeling of multiple modular home designs indicated that the upgraded envelope assemblies can yield heating energy savings of up to 50% and cooling energy savings of up to 30% compared to IECC 2018 standards.

Shrestha, Som [ORNL] (ORCID:0000000183993797)↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Numerical investigation of sound transmission through double wall cylinders with respect to active noise control

Market pressure for more fuel efficient air travel has led to increased use of turboprop and higher bypass turbofan engines. The low frequency components of propeller, jet and boundary layer noise are difficult to attenuate with conventional passive techniques. Weight and geometric restrictions for sound absorbing meterials limit the amount and type of treatment that may be applied. An active noise control (ANC) method is providing to be an attractive alternative. The approach taken in this paper uses a numerical finite/boundary element method (FEM/BEM) that may be easilty adapted to arbitrary geometries. A double walled cylinder is modeled using commercially available software. The outer shell is modeled as an aluminum cylinder, similar to that of aircraft skins. The inner shell is modeled as a composite material representative of a lightweight, stiff trim panel. Two different inner shell materials are used. The first is representative of current trim structure, the second a much stiffer composite. The primary source is generated by an exterior acoustic monopole. Control fields are generated using normal force inputs to the inner cylindrical shell. A linear least mean square (LMS) algorithm is used to determine amplitudes of control forces that minimize the interior acoustic field. Coupling of acoustic and structural modes and noise reductions are discussed for each of the inner shell materials.

Coats, T. J.↗

Low Cost Glass-Ceramic Matrix Composite Heat Exchanger

As part of ARPA-E’s High Intensity Thermal Exchange through Materials and Manufacturing Processes (HITEMMP) program, this project sought to develop novel heat exchanger (HX) capabilities to enable efficient and power dense power generation cycles. This class of HX comes under the category of ceramic/composite materials with the higher temperature goal in the program of ≥1100 °C inlet temperature operation. The enabling capability of this effort is the use of glass-ceramic matrix composite (GCMC) material which provides the high temperature durability of a ceramic, the flaw tolerance of a composite, a significantly faster and lower cost manufacturing process than conventional matrix CMCs and very low porosity levels < 0.5%. For thin-walled HX structures and the need to minimize leakage, the low porosity differentiator is particularly important. RTRC has prior experience with this material system and in the current project advanced the component design and manufacturing methods into new territory to produce features required for effective heat exchange under high pressures. In this approach, silicon carbide fiber is fabricated into a fiber preform using various textile processes. Graphite tooling is used both during the build-up of the fiber preform (interior tooling) and after the fiber preform has been completed (exterior tooling). This tooling assembly is heated to high temperature in an environment that has been evacuated and backfilled with inert gas. A reservoir of specialty glass is present and once the desired temperature has been reached to achieve the desired glass viscosity, an actuator distributes the glass throughout the fiber preform using passageways which are part of the tooling design in a process known as glass transfer molding. After the tooling has been removed, the composite is heat treated to convert the amorphous glass to a crystalline ceramic, providing improved properties. The project was divided into three phases focusing on the following: 1) 10 kW HX design and coupon-level tube sheet fabrication, 2) 10 kW HX fabrication, 3) 50 kW HX fabrication. During Budget Period 1 (BP1), additional risks were encountered and the need for additional funds was agreed upon by ARPA-E program leadership. Due to a variety of factors, the contract modification required nominally 18 months to execute at which time the HITEMMP program was effectively concluding. Because of this and the time that would be required to perform BP2 tasks, it was decided to conclude the project at the end of BP1. During the design of the 10 kW HX, manufacturing constraints were learned and incorporated, leading to a revised configuration for the fiber preform and HX. Heat exchange and pressure drop predictions also played a role in modifying the original design concept to be a higher aspect ratio shell-and-tube HX, simplifying the manufacturing process and improving the heat exchanger performance. Good gravimetric and volumetric thermal power densities of 11.2 kW/kg and 10,200 kW/m3 for the entire HX were projected that involved thermo-structural Finite Element Analysis to determine the structural mass needed for the high operation pressures of 250 bar cold inlet and 80 bar hot inlet. Fiber preforms using textile processes were produced for multiple headered tube sheets. Additional challenges were encountered during the glass transfer molding step for which solutions were identified, but programmatics did not allow them to be implemented in BP1. While complete HX test articles were not fabricated, the benefits of this GCMC material for a variety of high temperature applications remain.

30 DIRECT ENERGY CONVERSION↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Affordable Solid Panel "Perfect Wall" System

The SPS is an innovative interpretation of the “perfect wall” concept, in which environmental control layers are located on the exterior side of the structural components, as opposed to traditional cavity insulated, stud-framed walls. The primary objective of this study is to validate the SPS technology in terms of its constructability, cost, and performance. Specifically for this project, we partnered with two affordable housing nonprofits in Minnesota—Twin Cities Habitat for Humanity and Urban Homeworks—to build five new houses using SPS walls, as well as two high-performance stud-framed comparison homes. We also reviewed cost and performance data from 13 SPS homes built prior to this project by MonoPath and Spero Environmental Builders. Reviewing the outcomes of these 20 homes total, we find promising results in terms of constructability, cost, and performance, although more structural performance data are needed before this new technology can see widespread adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design, Construction, and Field Validation of a Blown-In Fiberglass Wall System in a Cold, Wet, and Windy Climate

In the Native Village of Tununak, located on Nelson Island in Southwest Alaska,buildings are exposed to wind-driven rain and snow throughout the year. The Cold Climate Housing Research Center (CCHRC) and Knauf Insulation partnered with the community in 2018 to design a residence for a public safety officer. Construction began in fall 2021 and is scheduled to conclude in summer 2022. The house will use integrated trusses with floor, attic, and wall cavities filled with blown-in fiberglass insulation. Hygrothermal models of the building envelope system demonstrate that the high ambient moisture load will wet the outer edges of the insulation annually regardless of the extent and integrity of exterior weather sealing measures; blown-in fiberglass is expected to be more resilient to this wetting than blown-in cellulose. To verify this, researchers will embed temperature, relative humidity, and moisture sensors in the two windward walls of the house to monitor the ability of the blown-in fiberglass insulation to dry out after wetting events that may have occurred during the transport of the insulation to the building site, storage of the insulation on site, construction process, or after installation in the wall. Sensors will remain in place for two years,documenting the wall's performance over time and verifying the design's potential for use in buildings located in climates where the chance for moisture damage is high. Here, we describe the wall system , design criteria, and the results from the hygrothermal modeling. We share details on the monitoring system's components and the planned management and analysis of data. Finally, we explain how the experiences and data from this project will inform future builds in similar locations.

building design↗

Development of the Electrostatic Precipitator (ESP) for Mars and Electrodynamic Dust Shield (EDS)

Kennedy Space Center's Swamp Works is a fast-paced and diverse technology development laboratory that aims to advance commercial and government capabilities to colonize extraterrestrial environments. As a part of Swamp Works, the Electrostatic and Surface Physics Laboratory (ESPL) is currently developing new technologies that will further NASA's capabilities to colonize lunar and Martian environments. At the ESPL, the objective of the overall project is to aid in the dust mitigation of robotic and human exploration missions to the moon and Mars. The moon and Mars are covered with layers of dust, which can make long-term exploration missions very difficult. The team at the ESPL is developing an electrostatic precipitator (ESP) to aid in the reduction of interference from airborne Martian dust on equipment. The ESP is designed to mitigate the dust in an intake of CO2-rich dusty gas (i.e., the Martian atmosphere). The ESP is essentially a cylindrical tube with a coaxial wire electrode. Applying a high voltage through this electrode induces a corona discharge (a glowing plasma that envelops the electrode), which is used to charge the inflowing dust. The electric field caused by the corona pushes the charged dust to the walls of the precipitator, preventing the dust to flow out of the tube. Environmental dust can make long-term exploration missions very difficult, and settled dust is no exception. Settled lunar or Martian dust can hinder the performance and lifetime of equipment. For example, dust can settle on the solar panels of a lunar or Martian rover, decreasing its performance while increasing its charging time. To address this, the team at the ESPL is also developing an electrodynamic dust shield (EDS), which is designed to remove lunar or Martian dust from the surfaces of equipment. The EDS uses a non-uniform electric field to generate a dielectrophoretic force, which pushes the particles away from the surface of the shield. A number of dust shields will be tested on the exterior of the International Space Station (ISS) via MISSE-11, a flight payload to the ISS that will test the effects of long-term exposure to space on materials. During my internship at the ESPL, I aided in the development of these technologies. For the ESP, I helped characterize the electrical properties of various geometries and helped redesign the hardware of the testbed (the precipitator used to test this technology in the lab). To characterize the electrical properties of the ESP, I ran various tests of the precipitator, which consisted of varying the environmental conditions and geometry of the testbed. Analyzing the electrical properties of the ESP in various environmental conditions is necessary to characterize its collection efficiency, since it will be used in the dusty Martian environment. For the EDS, I helped analyze the dielectric strength of the surface of the shield via high-voltage testing. A dielectrically strong surface will help the shield survive the harsh environment of space, which will enable it to have both lunar and Martian applications.

Corona Discharge↗

Transformative Efficiency and Automation in Modular Homes (TEAMH)

This report documents the Transformative Efficiency and Automation in Modular Homes (TEAMH) project, which evaluates the integration of advanced building envelope technologies and automation-assisted modular construction to improve residential energy performance and construction efficiency. The study investigates high-performance insulation systems, including vacuum insulation panels (VIPs), combined with light gauge steel (LGS) modular construction and factory automation. Laboratory testing, whole-building energy modeling across multiple climate zones, and factory demonstrations were conducted to assess thermal performance, energy savings, and production efficiency. Results indicate that upgraded envelope assemblies can achieve up to ~50% heating and ~34% cooling energy savings relative to IECC 2018 code-compliant homes, while automation-assisted construction can reduce wall assembly time by 24%–46% compared to conventional wood framing. The findings demonstrate the potential for scalable, high-performance modular homes that deliver significant energy savings with competitive projected costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗