Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Characteristics of Antarctic sea ice as determined by satellite-borne microwave imagers

The electrically scanning microwave radiometers on Nimbus 5 (wavelengths of 1.55 cm) and Nimbus 6 (wavelengths of 0.81 cm) produce images with a resolution of about 30 km. Weekly maps of sea ice coverage are generated, showing the percent of open water in each 2.5 x 2.5 degree cell. More detailed studies of the dynamics and thermodynamics of the sea ice and its interaction with the ocean and the atmosphere are carried out, using 3-day average pseudo-color images and maps of ice boundaries. Features of the Antarctic ice discerned from microwave images are discussed, and the important features of Antarctic currents are illustrated.

Zwally, H. J.↗

Inner Magnetospheric Electric Fields Derived from IMAGE EUV

The local and global patterns of plasmaspheric plasma transport reflect the influence of electric fields imposed by all sources in the inner magnetosphere. Image sequences of thermal plasma G:istribution obtained from the IMAGE Mission Extreme Ultraviolet Imager can be used to derive plasma motions and, using a magnetic field model, the corresponding electric fields. These motions and fields directly reflect the dynamic coupling of injected plasmasheet plasma and the ionosphere, in addition to solar wind and atmospheric drivers. What is being learned about the morphology of inner magnetospheric electric fields during storm and quite conditions from this new empirical tool will be presented and discussed.

Gallagher, D. L.↗

Television image of a large upward electrical discharge above a thunderstorm system

A low light-level TV camera is used to obtain an unusual image of luminous electrical discharge over a thunderstorm 250 km from the observation site. The image is presented and the discharge in the image is described. It is suggested that the image is probably due to two localized electric charge concentrations at the cloud tops. The hazard of these discharges for aircraft and rocket launches is examined. Consideration is given to the possibility that these discharges may account for unexplained photometric observations of distant lightning events that show a low rise rate of the luminous pulse and no electromagnetic sferic pulse like that in cloud-to-earth lightning strokes. The photometric events of this type that occurred on September 22-23, 1989 during hurricane Hugo are noted.

Franz, R. C.↗

Meteorological interpretations of the images from Nimbus 5 electrically scanned microwave radiometer

The Electrically Scanned Microwave Radiometer on the Nimbus 5 satellite measures microwave radiation in a band centered at 1.55 cm. It scans perpendicular to the satellite motion from 50 deg to the left to 50 deg to the right in the 78 steps every 4 seconds producing an image with a best resolution of 25 km. It is shown that these images can be used to delineate areas of rain over the oceans. This data can be used to approximate the location of fronts, the rain/snow boundary and secondary cyclogenesis.

Wilheit, T.↗

Back-illuminated imager and method for making electrical and optical connections to same

Methods for bringing or exposing metal pads or traces to the backside of a backside-illuminated imager allow the pads or traces to reside on the illumination side for electrical connection. These methods provide a solution to a key packaging problem for backside thinned imagers. The methods also provide alignment marks for integrating color filters and microlenses to the imager pixels residing on the frontside of the wafer, enabling high performance multispectral and high sensitivity imagers, including those with extremely small pixel pitch. In addition, the methods incorporate a passivation layer for protection of devices against external contamination, and allow interface trap density reduction via thermal annealing. Backside-illuminated imagers with illumination side electrical connections are also disclosed.

Pain, Bedabrata↗

Photocapacitive image converter

An apparatus for converting a radiant energy image into corresponding electrical signals including an image converter is described. The image converter includes a substrate of semiconductor material, an insulating layer on the front surface of the substrate, and an electrical contact on the back surface of the substrate. A first series of parallel transparent conductive stripes is on the insulating layer with a processing circuit connected to each of the conductive stripes for detecting the modulated voltages generated thereon. In a first embodiment of the invention, a modulated light stripe perpendicular to the conductive stripes scans the image converter. In a second embodiment a second insulating layer is deposited over the conductive stripes and a second series of parallel transparent conductive stripes perpendicular to the first series is on the second insulating layer. A different frequency current signal is applied to each of the second series of conductive stripes and a modulated image is applied to the image converter.

Miller, W. E.↗

Electric Field Reconstruction in the Image Plane of a High-Contrast Coronagraph Using a Set of Pinholes around the Lyot Plane

In a setup similar to the self coherent camera, we have added a set of pinholes in the diffraction ring of the Lyot plane in a high-contrast stellar Lyot coronagraph. We describe a novel complex electric field reconstruction from image plane intensity measurements consisting of light in the coronagraph's dark hole interfering with light from the pinholes. The image plane field is modified by letting light through one pinhole at a time. In addition to estimation of the field at the science camera, this method allows for self-calibration of the probes by letting light through the pinholes in various permutations while blocking the main Lyot opening. We present results of estimation and calibration from the High Contrast Imaging Testbed along with a comparison to the pair-wise deformable mirror diversity based estimation technique. Tests are carried out in narrow-band light and over a composite 10% bandpass.

coronagraphs↗

Diffraction Modeling of Finite Subband EFC Probing on Dark Hole Contrast with WFIRST-CGI Shaped Pupil Coronagraph

The current NASA WFIRST (Wide-Field InfraRed Survey Telescope) coronagraph instrument (CGI) design allocates two subband filters per each full science band in order to contain system complexity and cost. We present our detailed investigation results on the adequacy of such a limited number of finite subband filters in achieving broadband dark hole contrast with a shaped pupil coronagraph (SPC). The study is based on diffraction propagation modeling with realistic WFIRST optics, where each subband’s image plane electric field is estimated from pairwise pupil plane deformable mirror (DM) probing and image plane intensity averaging of the resulting fields of multiple (subband) wavelengths. Multiple subband choices and probing and control strategies are explored, including standard subband probing; mixed wavelength and/or weighted Jacobian matrix; subband probing with intensity subtraction; and extended subband probing with intensity subtraction. Overall, the investigation shows that the achievable contrast with a limited number of finite subbands is about 2~2.5x worse than the designed contrast for the current SPC. The result suggests that future shaped pupil designs should be optimized for slightly broader bandwidths than the intended science bandpasses if limited subbands are used for wavefront sensing via probing.

WFIRST↗

Dynamics Explorer guest investigator

A data base of satellite particle, electric field, image, and plasma data was used to determine correlations between the fields and the particle auroral boundaries. A data base of 8 days of excellent coverage from all instruments was completed. The geomagnetic conditions associated with each of the selected data periods, the number of UV image passes per study day that were obtained, and the total number of UV images for each day are given in tabular form. For each of the days listed in Table 1, both Vector Electric Field Instrument (VEFI) electric potential data and LAPI integrated particle energy fluxes were obtained. On the average, between 8 and 11 passes of useful data per day were obtained. These data are displayed in a format such that either the statistical electric field model potential or the statistical precipitation energy flux could be superimposed. The Heppner and Maynard (1987) and Hardy et al. (1987) models were used for the electric potential and precipitation, respectively. In addition, the auroral image intensity along the Dynamics Explorer-2 satellite pass could be computed and plotted along with the LAPI precipitation data and Hardy et al. (1987) values.

Sojka, Jan J.↗

Planetary mission summaries. Volume 1: Introduction and overview

Tabular synopses of twelve missions are presented along with the Mariner Jupiter/Saturn 1977 mission for comparison. Mission definitions considered include: Mars Polar Orbiter; Mars Surface Sample Return; Mars Rover; Marine Jupiter/Uranus 1979 with Uranus Entry Probe; Mariner Jupiter Orbiter; Mariner Mercury Orbiter 1978; Early Mariner Comet Flyby Solar Electric Encke Slow Flyby; Mariner Encke Ballistic Flyby; Solar Electric Encke Rendezvous 1981; Venus Orbital Imaging Radar; Solar Electric Out-of-the-Eliptic Probe 1979. Technical conclusions of mission studies are given in order that these results may interact with the broader questions of scope, pace, and priorities in the planetary exploration program.

Source record↗

Meteorological interpretations of the images from the Nimbus 5 electrically scanned microwave radiometer

The Nimbus 5 Electrically Scanned Microwave Radiometer (ESMR) is useful in determining the extent, structure, and intensity of rainfall over oceans. It is possible on the basis of rainfall maps to determine the location of frontal rain, rain/snow boundaries, and the structure of tropical storms. ESMR data on rainfall over the east coast of the United States and the Gulf of Mexico, on snowfall over the northeast coast of the United States, on frontal zones in the northwestern Pacific and on the tropical storm Leila in the South Indian Ocean are examined. Because of the generally high emissivities of land surfaces, interpretation of meteorological parameters over land is not yet possible.

Wilheit, T. T.↗

Landsat test of diffuse reflectance models for aquatic suspended solids measurement

Landsat radiance data were used to test mathematical models relating diffuse reflectance to aquatic suspended solids concentration. Digital CCT data for Landsat passes over the Bay of Fundy, Nova Scotia were analyzed on a General Electric Co. Image 100 multispectral analysis system. Three data sets were studied separately and together in all combinations with and without solar angle correction. Statistical analysis and chromaticity analysis show that a nonlinear relationship between Landsat radiance and suspended solids concentration is better at curve-fitting than a linear relationship. In particular, the quasi-single-scattering diffuse reflectance model developed by Gordon and coworkers is corroborated. The Gordon model applied to 33 points of MSS 5 data combined from three dates produced r = 0.98.

Munday, J. C., Jr.↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Boettger, Heinz G.↗

NASA NDE Program

The current activities in the National Aeronautics and Space Administration Nondestructive Evaluation (NDE) Program are presented. The topics covered include organizational communications, orbital weld inspection, electric field imaging, fracture critical probability of detection validation, monitoring of thermal protection systems, physical and document standards, image quality indicators, integrity of composite pressure vessels, and NDE for additively manufactured components.

Generazio, Ed↗

Image processing via ultrasonics - Status and promise

Acousto-electric devices for electronic imaging of light are discussed. These devices are more versatile than line scan imaging devices in current use. They have the capability of presenting the image information in a variety of modes. The image can be read out in the conventional line scan mode. It can be read out in the form of the Fourier, Hadamard, or other transform. One can take the transform along one direction of the image and line scan in the other direction, or perform other combinations of image processing functions. This is accomplished by applying the appropriate electrical input signals to the device. Since the electrical output signal of these devices can be detected in a synchronous mode, substantial noise reduction is possible

Kornreich, P. G.↗