At least 37 records · Page 2

Electrocoagulation of high-salinity produced water: lessons learned from its early applications in unconventional reservoir plays

Ample research has demonstrated that electrocoagulation is a versatile technology capable of facilitating the removal of a wide range of physical, biological, organic, and inorganic constituents such as suspended solids, turbidity, bacteria, viruses, oil and grease, organic carbon (including chemical and biological oxygen demand), silica, fluoride, and so on. Despite its purported advantages and extensive lab-scale evaluations, it has not yet been widely adopted for water and wastewater treatment and reuse at commercial scale. This is symptomatic of a chasm between its technological capabilities on one hand and field performance and reputation on the other. Herein, we opine as to why this might be the case using our collective experiences with the oil and gas industry as an exemplar. In this study, we highlight scientific, technological, engineering, and business issues that need to be addressed to realize the full potential of this promising technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Escherichia coli Attenuation by Fe Electrocoagulation in Synthetic Bengal Groundwater: Effect of pH and Natural Organic Matter

Technologies addressing both arsenic and microbial contamination of Bengal groundwater are needed. Fe electrocoagulation (Fe-EC), a simple process relying on the dissolution of an Fe(0) anode to produce Fe(III) precipitates, has been shown to efficiently remove arsenic from groundwater at low cost. In this work, we investigated Escherichia coli (E. coli) attenuation by Fe-EC in synthetic Bengal groundwater as a function of Fe dosage rate, total Fe dosed, pH, and presence of natural organic matter (NOM). A 2.5 mM Fe dosage simultaneously achieved over 4-log E. coli attenuation and arsenic removal from 450 to below 10 μg/L. E. coli reduction was significantly enhanced at pH 6.6 compared to pH 7.5, which we linked to the decreased rate of Fe(II) oxidation at lower pH. 3 mg/L-C of NOM (Suwanee River fulvic acid) did not significantly affect E. coli attenuation. Live-dead staining and comparisons of Fe-EC with chemical coagulation controls showed that the primary mechanism of E. coli attenuation is physical removal with Fe(III) precipitates, with inactivation likely contributing as well at lower pH. Transmission electron microscopy showed that EC precipitates adhere to and bridge individual E. coli cells, resulting in large bacteria-Fe aggregates that can be removed by gravitational settling. Our results point to the promising ability of Fe-EC to treat arsenic and bacterial contamination simultaneously at low cost.

54 ENVIRONMENTAL SCIENCES↗

Electrocoagulation Combined with Ultrafiltration Membranes as Pretreatment for RO Desalination of Synthetic Cooling Tower Blowdown Water

Electrocoagulation (EC), an electrochemical water treatment process, is commonly used to remove particulate and colloidal matter from water. Here, in this study, we demonstrate that EC, when coupled with membrane filtration, is also capable of removing dissolved species, such as Ca + , Mg 2+ , and SiO x . The removal of such species is important for downstream membrane-based desalination treatment of the water that can suffer from reduced performance due to membrane scaling. Here, we describe how EC can be combined with a low-pressure membrane (LPM) system to offer efficient (and potentially universal) pretreatment for downstream membrane desalination. Synthetic water, simulating cooling tower blowdown (CTBD) with elevated concentrations of hardness and silicates (Ca: 418 ppm, Mg: 63 ppm, SiO 2 : 50 ppm) is treated using EC coupled to ultrafiltration (UF) to remove Mg up to 30 ± 1%, Ca up to 29 ± 1%, and silica up to 99 ± 1%. We evaluated the effectiveness of the EC-UF pretreatment system in reducing downstream RO scaling using thermodynamic modeling to predict the saturation index (SI) at the RO membrane/water interface. An SI value below zero (SI < 0) indicates under-saturated conditions (with respect to a particular mineral) where mineral scaling does not take place, which correlates with improved water recovery. Our findings suggest that the EC-UF pretreatment system was able to increase water recovery by up to 30%, compared to 0% recovery without pretreatment, under optimal conditions (feed solution pH of 7 and an EC charge loading of 1800 C/L). Finally, we conducted an economic analysis showing that implementing an EC-UF system for CTBD water could yield a cost benefit of up to $\$$14.13 per m 3 compared to direct brine disposal.

cooling tower blowdown↗

Treatment of Lagoon Dairy Manure Wastewater via Iron Electrocoagulation, Microfiltration, and Adsorption

Dairy manure wastewater generated by flushing barn cow waste contains nutrients, pathogens, and organic and inorganic contaminants. This study utilized a process consisting of iron electrocoagulation (Fe-EC), microfiltration (MF), and activated carbon (AC) adsorption to treat farm wastewater and explore the reclamation of clean water for irrigation and livestock consumption. Significant removal (>99.9%) of chemical oxygen demand (COD), total organic carbon (TOC), phosphorus (P), turbidity, and microorganisms, as well as ions including magnesium, calcium, sulfur, and silica was achieved by the combined EC-MF-AC process. Specifically, a charge loading of ∼37,500 C/L in a continuous-flow EC configuration, followed by MF, achieved more than 95% removal of TOC and COD. Characterization of produced flocs and foam via scanning-electron microscopy with energy-dispersal spectroscopy and Fourier transform infrared spectroscopy confirmed the removal of ions, including calcium, sulfur, and silica. A key finding was the electrocatalytic conversion of nitrogen species to ammonia gas through the intermediate reduction of nitrate/nitrite, which led to ∼60% total nitrogen (TN) removal. AC treatment further improved TN removal to ∼70%. The Fe-EC process also eradicated >99.9% of bacteria. Preliminary process cost assessment, based on recycled materials for EC electrodes, showed significant cost savings (∼2 times) compared to commercial electrodes.

Dutta, Swapnamoy [ORNL]↗

Production and Transformation of Mixed-Valent Nanoparticles Generated by Fe(0) Electrocoagulation

Mixed-valent iron nanoparticles (NP) generated electrochemically by Fe(0) electrocoagulation (EC) show promise for on-demand industrial and drinking water treatment in engineered systems. This work applies multiple characterization techniques (in situ Raman spectroscopy, XRD, SEM, and cryo-TEM) to investigate the formation and persistence of magnetite and green rust (GR) NP phases produced via the Fe(0) EC process. Current density and background electrolyte composition were examined in a controlled anaerobic system to determine the initial Fe phases generated as well as transformation products with aging. Fe phases were characterized in an aerobic EC system with both simple model electrolytes and real groundwater to investigate the formation and aging of Fe phases produced in a system representing treatment of arsenic-contaminated ground waters in South Asia. Two central pathways for magnetite production via Fe(0) EC were identified: (i) as a primary product (formation within seconds when DO absent, no intermediates detected) and (ii) as a transformation product of GR (from minutes to days depending on pH, electrolyte composition, and aging conditions). Furthermore, this study provides a better understanding of the formation conditions of magnetite, GR, and ferric (oxyhydr)oxides in Fe EC, which is essential for process optimization for varying source waters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field Validation of Electrocoagulation Treatment for Oily Wastewater at Cleveland-Cliffs Steel Mill in Cleveland, OH

The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized technologies in the industrial sector to help inform decisions towards accelerating commercialization and deployment. This initiative aims to identify, validate, and showcase new, emerging, and underutilized technologies in the industrial sector to expedite their commercialization and widespread deployment. By conducting thorough validations and demonstrating the efficacy of these technologies, the ITV program facilitates informed decision-making among industry stakeholders, contributing to the transition towards more sustainable and efficient industrial processes. This ITV demonstration involved the testing of an electrocoagulation (EC) treatment system at a steel plant in Ohio. The system was designed to treat oily wastewater generated from cold rolling operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TREATABILITY TEST REPORT FOR THE REMOVAL OF CHROMIUM FROM GROUNDWATER AT 100-D AREA USING ELECTROCOAGULATION

The U.S. Department of Energy (DOE) has committed to accelerate cleanup of contaminated groundwater along the Columbia River. The current treatment approach was driven by a series of Interim Action Records of Decision (IAROD) issued in the mid-1990s. Part of the approach for acceleration involves increasing the rate of groundwater extraction for the chromium plume north of the 100-D Reactor and injecting the treated water in strategic locations to hydraulically direct contaminated groundwater toward the extraction wells. The current treatment system uses ion exchange for Cr(VI) removal, with off-site regeneration of the ion exchange resins. Higher flow rates will increase the cost and frequency of ion exchange resin regeneration; therefore, alternative technologies are being considered for treatment at high flow rates. One of these technologies, electrocoagulation (EC), was evaluated through a pilot-scale treatability test. The primary purpose of the treatability study was to determine the effectiveness of Cr(VI) removal and the robustness/implementability of an EC system. Secondary purposes of the study were to gather information about derivative wastes and to obtain data applicable to scaling the process from the treatability scale to full-scale. The treatability study work plan identified a performance objective and four operational objectives. The performance objective for the treatability study was to determine the efficiency (effectiveness) of hexavalent chromium removal from the groundwater, with a desired concentration of {le} 20 micrograms per liter ({micro}g/L) Cr(VI) in the effluent prior to re-injection. Influent and effluent total chromium and hexavalent chromium data were collected using a field test kit for multiple samples per week, and from off-site laboratory analysis of samples collected approximately monthly. These data met all data quality requirements. Two of three effluent chromium samples analyzed in the off-site (that is, fixed) laboratory met the performance objective during the continuous operational testing. Effluent hexavalent chromium analyzed by the field laboratory met the performance goal in over 90 percent of the samples. All effluent hexavalent chromium samples during the batch testing with high influent hexavalent chromium concentrations ({approx}2000 {micro}g/L) met the performance objective. Although the EC system was able to meet the performance goal, it must be noted that it was not uncommon for the system to be operated in recycle mode to achieve the performance goal. The EC unit was sometimes, but not always, capable of a single pass treatment efficiency high enough to meet the performance goal, and recycling water for multiple treatment passes was effective. An operational objective was to determine the volume and composition of the waste streams to enable proper waste designation. The toxicity characteristic leaching procedure (TCLP) concentrations, pH, and free liquids were determined for solid material from the EC electrodes (mechanically removed scale), the filter press, and the tank bottoms for the effluent and waste collector tanks. These data met all data quality requirements. All solid-phase secondary waste streams were found to be below the TCLP limits for the toxicity characteristic, and a pH value within the limits for the corrosivity characteristic. Out of three samples, two (one of scale from the EC unit and one from filter press solids) failed the free liquid (paint filter) test, which is one of the acceptability criteria for Hanford's Environmental Restoration Disposal Facility (ERDF). The solid-phase waste generation rate was about 0.65-gallon of solid waste per 100 gallons of water treated. It is concluded that the solid-phase secondary waste generated from this technology under the conditions at the test site will meet the toxicity and corrosivity criteria for disposal. It is also concluded that with engineering and/or operational improvements, a solid-phase secondary waste could be produced that would meet the free liquid disposal requirements. The second operational objective was to assess the operational reliability and safety of the system. For the continuous operations testing period from July 23 to September 12,2007, the system was not able to operate unattended. An extensive period of startup and adjustment preceded continuous operations, but was unsuccessful in providing a suitable and robust operating condition. Primary operational reliability problems were related to the sensitivity of the solid separation process to operational conditions such that a robust operating procedure (for example, chemical dosage) was not identified during the treatability test. Poor solids separation and high effluent iron concentrations also led to operational difficulties associated with injection well fouling.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ion concentration polarization-electrocoagulation hybrid water treatment system

Between two juxtaposed similar ion exchange membranes (AEMs or CEMs), an ion depletion zone and ion enrichment zone are generated under an electric field. As cations are selectively transferred through the CEMs, for example, anions are relocated in order to achieve electro-neutrality, resulting in the concentration drop (increase) in ion depletion (enrichment) zone. The use of a sacrificial metal anode allows electrocoagulation (EC) concurrently with ICP thereby permitting concentration of both ionic and non-ionic impurities to occur at the same time within the same cell or device.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field Validation of Electrocoagulation Treatment for Oily Wastewater at a Steel Mill

Oily wastewater is a significant byproduct across various industries, including steel production, posing environmental and health risks. Steelmaking is particularly water-intensive, with an estimated 75,000 gallons required to produce 1 ton of steel, although recycling reduces this to 13,000–23,000 gallons per ton.1 Water serves multiple purposes in steelmaking, including equipment cooling, scale removal, steam generation, lubrication, and pollution control.

54 ENVIRONMENTAL SCIENCES↗

RESULTS FROM RECENT SCIENCE AND TECHNOLOGY INVESTIGATIONS TARGETING CHROMIUM IN THE 100D AREA HANFORD SITE WASHINGTON USA

Sodium dichromate was used in Hanford's 100D Area during the reactor operations period of 1950 to 1964 to retard corrosion in the reactor cooling systems. Some of the sodium dichromate was released to the environment by spills and/or leaks from pipelines used to deliver the chemical to water treatment plants in the area. As a result, hexavalent chromium [Cr(VI)] has migrated through the vadose zone to the groundwater and contaminated nearly 1 km{sup 2} of groundwater to above the drinking water standard of 48 {micro}g/L. Three technology tests have recently been completed in this area to characterize the source area of the plumes and evaluate alternative methods to remove Cr(VI) from groundwater. These are (1) refine the source area of the southern plume; (2) test electrocoagulation as an alternative groundwater treatment technology; and (3) test the ability to repair a permeable reactive barrier by injecting micron or nanometer-size zero-valent iron (ZVI). The projects were funded by the US Department of Energy as part of a program to interject new technologies and accelerate active cleanup. Groundwater monitoring over the past 10 years has shown that Cr(VI) concentrations in the southern plume have not significantly diminished, strongly indicating a continuing source. Eleven groundwater wells were installed in 2007 and 2008 near a suspected source area and monitored for Cr(VI) and groundwater levels. Interpretation of these data has led to refinement of the source area location to an area of less than 1 hectare (ha, 2.5 acres). Vadose zone soil samples collected during drilling did not discover significant concentrations of Cr(VI), indicating the source is localized, with a narrow wetted path from the surface to the water table. Electrocoagulation was evaluated through a pilot-scale treatability test. Over 8 million liters of groundwater were treated to Cr(VI) concentrations of {le}20 {micro}g/L. The test determined that this technology has the potential to treat Cr(VI) to these low levels, but system reliability and operational complexity rendered electrocoagulation less cost effective than the baseline technology of ion exchange. Laboratory and field tests were conducted to evaluate the practicality of injecting ZVI into the aquifer to increase the lifespan and effectiveness of an existing permeable reactive barrier. From a database of 30 ZVI materials, 6 were chosen and tested in the laboratory to determine their geochemical and physical performance under simulated 100D aquifer conditions. The best-performing ZVI was injected into the aquifer and met the primary goals of communicating the iron at least 7 meters from the injection point and reducing the aquifer to transform mobile Cr(VI) to trivalent chromium Cr(III), which is effectively immobile in the aquifer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Intensified Flue Gas Desulfurization Water Treatment for Reuse, Solidification, and Discharge

The goal of this final project report is to summarize the work conducted on project DE-FE0031555. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UK CAER) (Recipient) developed a hybrid electrochemical-membrane technology for treating wet flue gas desulfurization (WFGD) blowdown from coal-fired power generation plants that (1) removes government-regulated species and total suspended solids (TSS) via electrocoagulation with solid/liquid separation to avoid further treatments by a biological method specifically for selenium, and (2) reduces total dissolved solids (TDS) in a nanofiltration unit to promote water recycle and reduce freshwater intake. Additional technological configurations were pursued, including (1) nanofiltration combined with zeolite dewatering for a near-zero liquid discharge (ZLD) scenario, and (2) polishing discharge from zeolite dewatering using capacitive deionization (CDI) with 90+% salt rejection to produce water with less than 100ppm TDS for more beneficial use. Project results verified that UK CAER’s hybrid approach addressed the complexities of WFGD blowdown with simplified unit operation at relatively low capital investment by demonstrating: (1) an effective in-situ generated solid sorbent material, green-rust (GR), that specifically removes regulated dissolved species in WFGD blowdown, including selenium, arsenic, and nitrates; (2) a low-cost, high flux nanofiltration treatment that removes both monovalent and divalent species at >80% rejection to adequately provide water recycle and extend the life of FGD equipment by mitigating chloride aided pitting corrosion mechanisms; and (3) a solidification and stabilization process using pozzolanic agents that retain regulated species and satisfy the Resource Conservation and Recovery Act (RCRA) leachate requirements. UK CAER proved electrocoagulation with GR to be an intensified solution for effluent limit guidelines (ELG), and based on preliminary techno-economic analysis (TEA), in comparison to DOE’s Case 1 for Biological Wastewater Treatment that had a purchased equipment cost (PEC) of $\$$5.26 million and a Total plant cost (TPC) of $\$$30.0 million, the EC process had a PEC of $\$$2.67 million and the TPC of $\$$17.0 million. While the electricity consumption for Case 1 was 53 kW, it was 110 kW for the EC process due to dissolving iron for a three-stage reaction design. However, electricity consumption for the EC process could be significantly reduced by adopting a counter-current reactor design for at least a 6-stage chemical reaction operation.

01 COAL, LIGNITE, AND PEAT↗

SUPPLEMENTAL COLUMBIA RIVER PROTECTION ACTIVITIES AT THE DEPARTMENT OF ENERGY HANFORD SITE 2008 TECHNICAL REVIEW

Beginning in 2006, the US Department of Energy (DOE) supported nine applied research projects to improve the protection of the Columbia River and mitigate the impacts of Hanford Site groundwater. These projects were funded through a supplemental Congressional budget allocation, and are now in various stages of completion in accordance with the research plans. The DOE Office of Environmental Management Groundwater and Soil Cleanup Technologies (EM-22) sponsored a technical peer review meeting for these projects in Richland WA, July 28-31, 2008. The overall objective of the peer review is to provide information to support DOE decisions about the status and potential future application of the various technologies. The charge for the peer review panel was to develop recommendations for each of the nine 'technologies'. Team members for the July 2008 review were Brian Looney, Gene LeBoeuf, Dawn Kaback, Karen Skubal, Joe Rossabi, Paul Deutsch, and David Cocke. Previous project reviews were held in May 2007 and March-May of 2006. The team used the following four rating categories for projects: (a) Incorporate the technology/strategy in ongoing and future EM activities; (b) Finish existing scope of applied research and determine potential for EM activities when research program is finished; (c) Discontinue current development activities and do not incorporate technology/strategy into ongoing and future EM activities unless a significant and compelling change in potential viability is documented; and (d) Supplement original funded work to obtain the data needed to support a DOE decision to incorporate the technology into ongoing and future EM activities. The supplemental funding portfolio included two projects that addressed strontium, five projects that addressed chromium, one project that addressed uranium and one project that addressed carbon tetrachloride. The projects ranged from in situ treatment methods for immobilizing contaminants using chemical-based methods such as phosphate addition, to innovative surface treatment technologies such as electrocoagulation. Total funding for the nine projects was $9,900,000 in fiscal year (FY) 2006 and $2,000,000 in FY 2007. At the Richland meeting, the peer reviewers provided a generally neutral assessment of the projects and overall progress, and a generally positive assessment with regard to the principal investigators meeting their stated research objectives and performing the planned laboratory research and limited field work. Only one project, the Electrocoagulation Treatability Test, received a rating of 'discontinue' from the team because the project goals had not been met. Because this particular project has already ended, no action with respect to funding withdrawal is necessary. All other projects were recommended to be finished and/or incorporated into field efforts at Hanford. Specific technical comments and recommendations were provided by the team for each project.

54 ENVIRONMENTAL SCIENCES↗