Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron exposure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Radiometric infrared focal plane array imaging system for thermographic applications

This document describes research performed under the Radiometric Infrared Focal Plane Array Imaging System for Thermographic Applications contract. This research investigated the feasibility of using platinum silicide (PtSi) Schottky-barrier infrared focal plane arrays (IR FPAs) for NASA Langley's specific radiometric thermal imaging requirements. The initial goal of this design was to develop a high spatial resolution radiometer with an NETD of 1 percent of the temperature reading over the range of 0 to 250 C. The proposed camera design developed during this study and described in this report provides: (1) high spatial resolution (full-TV resolution); (2) high thermal dynamic range (0 to 250 C); (3) the ability to image rapid, large thermal transients utilizing electronic exposure control (commandable dynamic range of 2,500,000:1 with exposure control latency of 33 ms); (4) high uniformity (0.5 percent nonuniformity after correction); and (5) high thermal resolution (0.1 C at 25 C background and 0.5 C at 250 C background).

Esposito, B. J.↗

640 x 480 MWIR and LWIR camera system developments

The performance of a 640 x 480 PtSi, 3,5 microns (MWIR), Stirling cooled camera system with a minimum resolvable temperature of 0.03 is considered. A preliminary specification of a full-TV resolution PtSi radiometer was developed using the measured performance characteristics of the Stirling cooled camera. The radiometer is capable of imaging rapid thermal transients from 25 to 250 C with better than 1 percent temperature resolution. This performance is achieved using the electronic exposure control capability of the MOS focal plane array (FPA). A liquid nitrogen cooled camera with an eight-position filter wheel has been developed using the 640 x 480 PtSi FPA. Low thermal mass packaging for the FPA was developed for Joule-Thomson applications.

Tower, J. R.↗

Evaluation of reformulated thermal control coatings in a simulated space environment. Part 1: YB-71

The Air Force Space and Missile Systems Center and Wright Laboratory Materials Directorate (WL/ML) have sponsored and effort to effort to reformulate and qualify Illinois Institute of Technology Research Institute (IITRI) spacecraft thermal control coatings. S13G/LO-1, Z93, and YB-71 coatings were reformulated because the potassium silicate binder, Sylvania PS-7, used in the coatings is no longer manufactured. Coatings utilizing the binder's replacement candidate, Kasil 2130, manufactured by The Philadelphia Quartz (PQ) Corporation, Baltimore, Maryland, and undergoing testing at the Materials Directorate's Space Combined Effects Primary Test and Research Equipment (SCEPTRE) Facility operated by the University of Dayton Research Institute (UDRI). The simulated space environment consists of combined ultraviolet (UV) and electron exposure with in site specimen reflectance measurements. A brief description of the effort at IITRI, results and discussion from testing the reformulated YB-71 coating in SCEPTRE, and plans for further testing of reformulated Z93 and S13G/LO-1 are presented.

Cerbus, Clifford A.↗

High Energy Electron and Gamma - Ray Detection with ATIC

The Advanced Thin Ionization Calorimeter (ATIC) balloon borne ionization calorimeter is well suited to record and identify high energy cosmic ray electrons, and at very high energies gamma-ray photons as well. We have simulated the performance of the instrument, and compare the simulations with actual high energy electron exposures at the CERN accelerator. Simulations and measurements do not compare exactly, in detail, but overall the simulations have predicted actual measured behavior quite well. ATIC has had its first 16 day balloon flight at the turn of the year over Antarctica, and first results obtained using the analysis methods derived from simulations and calibrations will be reported.

Chang, J.↗

High Energy Electron Detection with ATIC

The ATIC (Advanced Thin Ionization Calorimeter) balloon-borne ionization calorimeter is well suited to record and identify high energy cosmic ray electrons. The instrument was exposed to high-energy beams at CERN H2 bean-dine in September of 1999. We have simulated the performance of the instrument, and compare the simulations with actual high energy electron exposures at the CERN accelerator. Simulations and measurements do not compare exactly, in detail, but overall the simulations have predicted actual measured behavior quite well.

Chang, J.↗

X-Ray Exposure of Electron-Deposited Photoresist for Conformal Lithography on Corrugated Surfaces

Proximity printing using synchrotron X-ray lithography provides high resolution pattern transfer with large depth of field, low diffraction effects and no reflection from the substrate. Electro-plating of photo-resist allows deposition of thin, uniform films over geometrically complex and topographically diverse, electrically conductive surfaces.

Electron-deposited resist X-ray lithography Deep d↗

Solar and geomagnetic modulation of low-energy secondary cosmic ray electrons.

Balloon exposures of hodoscope instruments at Churchill, Manitoba; Minneapolis, Minnesota; and Sioux Falls, South Dakota, have established that the flux of return albedo electrons does not depend upon launch latitude and varies with solar modulation in proportion to the intensity of atmospheric secondary electrons. Only one flight out of 21 showed any indication of a magnetospheric electron flux significantly in excess of that attributable to albedo. Diurnal changes in geomagnetic cutoffs exhibit marked variability from day to day, as was illustrated by one flight in which a low cutoff was observed at Churchill throughout the daytime hours. The intensity increase of 15- to 65-MeV primary cosmic ray electrons due to solar modulation was no more than a factor of 2 from 1969-1970 to 1971.

Luhmann, J. G.↗

Total Dose Survivability of Hubble Electronic Components

A total dose analysis for exposure of electronic parts at the box level is presented for the Hubble Space Telescope. This was done using solid angle sectoring/3-dimensional ray trace and Monte Carlo radiation transport simulations. Results are discussed in terms of parts that are potential total dose concerns.

Monte Carlo radiation transport simulation↗

Effects of Surface Treatments on Secondary Electron Emission from CVD Diamond Films

Secondary electron emission (SEE) properties of polycrystalline diamond films grown by chemical vapor deposition (CVD) were measured. The total secondary yield (sigma) from as-grown samples was observed to be as high as 20 at room temperature and 48 while heating at 700 K in vacuum. Electron-beam-activated, alkali-terminated diamond films have shown stable values of sigma as high as 60 when coated with CsI and similarly high values when coated with other alkali halides. Diamond coated with BaF2 had a stable sigma of 6, but no enhancement of the SEE properties was observed with coatings of Ti or Au. Hydrogen was identified to give rise to this effect in as-grown films. However, electron beam exposure led to a reduction in sigma values as low as 2. Exposure to a molecular hydrogen environment restored sigma to its original value after degradation, and enabled stable secondary emission during electron beam exposure. Atomic hydrogen and hydrogen plasma treatments were performed on diamond/Mo samples in an attempt to increase the near-surface hydrogen concentration which might lead to increased stability in the secondary emission. Raman scattering analysis, scanning electron microscopy, and Auger electron spectroscopy (AES) confirmed that hydrogen plasma and atomic hydrogen treatments improved the quality of the CVD diamond significantly. Elastic recoil detection (ERD) showed that heating as-grown diamond targets to 7OO K, which was correlated with an increase in sigma, removed contaminants from the surface but did not drive hydrogen from the diamond bulk. ERD showed that the hydrogen plasma treatment produced an increase in the hydrogen concentration in the near-surface region which did not decrease while heating in vacuum at 700 K, but no improvement in the SEE properties was observed.

Mearini, G. T.↗

Electron temperature and concentration in a thermal atomic oxygen source

A thermal atomic oxygen source for materials screening was built for NASA by Boeing Aerospace. The objective here was to use a microwave interferometer and Langmuir probe to characterize the electron concentration in this thermal atomic oxygen source. Typical operating conditions in the thermal atomic oxygen source were found to produce electron concentrations that were well below the detection threshold of the interferometer (10(exp 8) cm (sup -3)). The researchers calibrated (with the interferometer) the Langmuir probe at an artificially high plasma density and then used the circular and the square Langmuir probes to measure the low electron concentrations that exist during materials exposure tests. Electron concentration was measured as a function of power and position. The electrons were lost to the walls through ambipolar diffusion, and their concentration was accurately described by an equation. The electron concentration was proportional to power squared and decayed exponentially with distance.

Pedrow, Patrick Dennis↗

The effect of high-energy electron radiation on poly(arylene ether)s

Thin films of four experimental poly(arylene ether)s of similar chemical structure were exposed to 1 MeV electrons while under high vacuum. The films received total exposures of 5 x 10 exp 7 and 1 x 10 exp 9 rads at a dose rate of 5 x 10 exp 7 rads/h and a pressure of 2 x 10 exp -7 torr. Films exposed to 5 x 10 exp 7 rads showed dramatic changes in molecular weight distribution. After exposures of 1 x 10 exp 9 rads the films were only partially soluble in chloroform and exhibited no detectable changes in the glass transition temperatures. Thin-film tensile properties were also altered by the exposure to electron radiation. The effect of the exposures as determined by various analyses is discussed.

Connell, J. W.↗

Characterization of Novel Spacecraft Materials Under High Energy Electron and Atomic Oxygen Exposure

The harsh space environment imposes stringent requirements upon spacecraft materials, especially those located on exterior surfaces of space objects in low Earth orbit (LEO). As humankind moves from space exploration to space commercialization, these polymers may have to last for 15–20 years without considerable degradation of their material properties. Hence, we must understand the effects of the space environment on materials currently in use as well as on untested materials. In the presented study authors exposed several space-relevant polymers to the simulated space weather comprised by electrons and atomic oxygen irradiation. First, materials were thoroughly characterized in their pristine state to create a baseline for the ground- and space-based experiments. Next, alteration of optical, surface, and charge transport properties of the same materials were studied under space-simulated environment.

Elena A. Plis↗

Performance of candidate SEPS solar cells as a function of low temperature and low intensity exposure and 1 MeV electron irradiation

The behavior of 144 high-performance shallow-junction silicon solar cells under conditions of low temperature and intensity was examined. The cells represented nine combinations of thickness, base resistivity, front surface texture, and rear surface treatment. At least 16 cells of each type were individually tested both as active elements under light levels between 0.04 and 1.0 solar constant and in the dark as passive rectifiers under external forward bias. One cell type was also irradiated with 1 MeV electrons up to 2.7 x 10 to the 15th e/sq cm. The inferior cells demonstrated high ohmic and/or non-ohmic shunting. No series resistance or Schottky barrier effects were observed. Fluences beyond 10 to the 13th e/sq cm lowered cell current, probably by increasing volume recombination.

Whitaker, A. F.↗

Programmable hyperspectral image mapper with on-array processing

A hyperspectral imager includes a focal plane having an array of spaced image recording pixels receiving light from a scene moving relative to the focal plane in a longitudinal direction, the recording pixels being transportable at a controllable rate in the focal plane in the longitudinal direction, an electronic shutter for adjusting an exposure time of the focal plane, whereby recording pixels in an active area of the focal plane are removed therefrom and stored upon expiration of the exposure time, an electronic spectral filter for selecting a spectral band of light received by the focal plane from the scene during each exposure time and an electronic controller connected to the focal plane, to the electronic shutter and to the electronic spectral filter for controlling (1) the controllable rate at which the recording is transported in the longitudinal direction, (2) the exposure time, and (3) the spectral band so as to record a selected portion of the scene through M spectral bands with a respective exposure time t(sub q) for each respective spectral band q.

Cutts, James A.↗

Europa Missions: Generic Materials Test Methodology

This viewgraph presentation discusses: radiation fundamentals, radiation damage, how radiation dosage is determined, fluence testing approaches, ionization damage exposure, displacement damage exposure, Europa energy "bins", rationale for group flux (energy bins), electron/proton group fluences, electron beam exposure testing, proton sources, reactor exposures, gamma exposures, preliminary exposure findings, testing caveats, preliminary conclusions, internal discharge, and electron dose depth curves.

radiation↗

Results of protective coating studies for the Hubble Space Telescope solar array

An account is given of the methods, results, and interpretive conclusions obtained by a series of comprehensive performance verification/qualification tests conducted on candidate coatings for the Hubble Space Telescope's (HST) solar array. These coatings are intended to minimize the effects of orbital atomic oxygen impingement on exposed materials. Attention was given to atomic oxygen exposure, UV exposure, thermal cycling, and electron and proton exposure. The V-10 and CVI-1140-1 candidate coatings were demonstrated to be adequately resistant to a five-year HST mission's environmental exposure.

Linton, Roger C.↗

Infrared spectroscopic analysis of the effects of simulated space radiation on a polyimide

Infrared spectroscopic techniques have been used to study the effects of electron radiation on the polyimide PMDA-p,p-prime- ODA. The radiation exposures were made at various dose rates, for a total dose approximately equal to that for 30 years of exposure to electron radiation in geosynchronous earth orbit. At high dose rates the major effect was probably the formation of a polyisoimide or a charged quaternary amine, and at the low dose rates the effect was a reduction in the amount or aromatic ether linkage. In addition, the effects of dose rate for a small total dose were studied. Elevated temperatures occurred at high dose rates and were, in part, probably the cause of the radiation product. The data suggest that dose rates for accelerated simulations of the space environment should not exceed 100,000 rads/sec.

Ferl, J. E.↗