SEARCH · Search NASA
Results for “Emission Tomography”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Positron Emission Tomography Imaging of Functional Transforming Growth Factor β (TGFβ) Activity and Benefit of TGFβ Inhibition in Irradiated Intracranial Tumors
Transforming growth factor β (TGFβ) promotes cell survival by endorsing DNA damage repair and mediates an immunosuppressive tumor microenvironment. Thus, TGFβ activation in response to radiation therapy is potentially targetable because it opposes therapeutic control. Strategies to assess this potential in the clinic are needed.
Positron Emission Tomography–Magnetic Resonance Imaging Pharmacokinetics, In Vivo Biodistribution, and Whole-Body Elimination of Mn-PyC3A
Not provided.
A Novel Approach to Map Permeability Using Passive Seismic Emission Tomography
Newly acquired magnetotelluric data and passive seismic data collected with tightly spaced geophone arrays are combined with historic drilling, active seismic, and potential fields data to generate 3-D permeability maps. A cooperative inversion methodology has been developed using active seismic, magnetotelluric, and gravity data in order to produce more robust velocity models for passive seismic data processing without requiring expensive 3-D active seismic surveys. The cooperative inversion estimates velocities from other geophysical data where no prior seismic velocity information is available at two geothermal sites in Nevada: San Emidio and Crescent Valley.
Imaging of Fibroblast Activation Protein Alpha Expression in a Preclinical Mouse Model of Glioma Using Positron Emission Tomography
Glioblastoma multiforme (GBM) is the most aggressive glioma of the primary central nervous system. Due to the lack of effective treatment options, the prognosis for patients remains bleak. Fibroblast activation protein alpha (FAP), a 170 kDa type II transmembrane serine protease was observed to be expressed on glioma cells and within the glioma tumor microenvironment. To understand the utility of targeting FAP in this tumor type, the immuno-PET radiopharmaceutical [ 89 Zr]Zr-Df-Bz-F19 mAb was prepared and Lindmo analysis was used for its in vitro evaluation using the U87MG cell line, which expresses FAP endogenously. Lindmo analysis revealed an association constant (K a ) of 10 -8 M -1 and an immunoreactivity of 52%. Biodistribution studies in U87MG tumor-bearing mice revealed increasing radiotracer retention in tumors over time, leading to average tumor-to-muscle ratios of 3.1, 7.3, 7.2, and 8.3 at 2, 24, 48 and 72 h, respectively. Small animal PET corroborated the biodistribution studies; tumor-to-muscle ratios at 2, 24, 48, and 72 h were 2.0, 5.0, 6.1 and 7.8, respectively. Autoradiography demonstrated accumulated activity throughout the interior of FAP + tumors, while sequential tumor sections stained positively for FAP expression. Conversely, FAP - tissues retained minimal radioactivity and were negative for FAP expression by immunohistochemistry. These results demonstrate FAP as a promising biomarker that may be exploited to diagnose and potentially treat GBM and other neuroepithelial cancers.
Positron Emission Tomography Imaging of Cell Trafficking: A Method of Cell Radiolabeling
Not provided.
Fan Beam Emission Tomography for Estimating Scalar Properties in Laminar Flames
A new method of estimating temperatures and gas species concentrations (CO2 and H2O) in a laminar flame is reported. The path-integrated, spectral radiation intensities emitted from a laminar flame at multiple wavelengths and view angles are calculated using a narrow band radiation model. Synthetic data, in the form of radial profiles of temperature and gas concentrations, are used in these calculations. The calculations mimic measurements that would theoretically be obtained using a mid-infrared spectrometer with a scanner. The path integrated spectral radiation intensities are deconvoluted using a maximum likelihood estimation method in conjunction with an iterative scheme. The deconvolution algorithm accounts for the self-absorption of radiation by the intervening gases, and provides the local temperature and gas species concentrations. The deconvoluted temperatures and gas concentrations are compared with the synthetic data used for calculating the spectral radiation intensities. The deconvoluted temperatures and gas species concentrations are within 0.5 % of the synthetic data. The deconvolution algorithm is expected to provide combustion researchers with an easy method of obtaining the radial profiles of major gas species concentrations and temperatures in laminar flames non-intrusively using a mid-infrared spectrometer with a scanner.
Fan Beam Emission Tomography Demonstrated Successfully in the Reduced-Gravity Environment of Drop Towers
Fires onboard manned spacecraft and launch vehicles are a particularly feared hazard because one cannot jump ship while in orbit 240 nmi above the Earth at 17 000 mph! Understanding the physical properties of fires in free fall and on orbit is, therefore, a very important endeavor for NASA s Human Exploration and Development of Space (HEDS) enterprise. However, detailed information concerning the structure of microgravity fires remained elusive until recently since robustness, limited power, limited volume, and limited mass place severe constraints on diagnostic equipment for use in space and in NASA Glenn Research Center s reduced-gravity facilities. Under NASA Research Associate funding since 2001, En'Urga, Inc. (Dr. Sivathanu, principal investigator, and Dr. Lim, co-investigator) in collaboration with Glenn (Dr. Feikema, coinvestigator) have successfully demonstrated a new technology for use in microgravity combustion. A midinfrared scanning spectrometer has been developed by En'Urga and tested at Glenn to measure 30 spectra per second at different spatial locations in a flame from 1.8 to 4.8 microns.
Non-Intrusive Visualization of Optically Inaccessible Flow Fields Utilizing Positron Emission Tomography
Explore the source record for details and available documents.
An atlas of Doppler emission-line tomography of cataclysmic variable stars
Doppler emission-line tomography is a technique similar to medical tomography. In this atlas the emission-line profiles of cataclysmic variable stars, seen at different orbital phases, are transformed into velocity space images. This transformation makes many of the complex line profile changes easier to interpret. The emission contributions of the disk and the s-wave are clearly separated in these images, and any emission from the stream and the secondary star can often be identified. In this atlas, Doppler tomograms of Hbeta, He I lambda 4471, and He II lambda 4686 emission lines of 18 cataclysmic variable stars are presented. The Doppler images provide insights into the individual systems and a better technique for measuring and radial velocity amplitude of the white dwarf.
Dynamic three-dimensional maps of solute concentration and solute arrival times in synthetic and geologic porous media
Experimental and training data associated with the publication entitled ‘Three-Dimensional Permeability Inversion Using Convolutional Neural Networks and Positron Emission Tomography’ (published in WRR, DOI: 10.1029/2021WR031554). The dataset contain three-dimensional maps of various properties on four geologic rock cores obtained from X-ray Computed Tomography and Positron Emission Tomography imaging measurements. The synthetic training dataset used in the publication is also attached.
A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms
Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.
1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings
The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.
Use of Constrained Gamma Emission Computed Tomography to Evaluate Fission Product Distributions in High-Temperature Materials from a TRISO Fuel Irradiation
An image reconstruction technique was developed to overcome problems with earlier methods of gamma emission computed tomography of graphite rings surrounding the AGR-3/4 TRISO fission product transport experiment. The profiles obtained from the tomography are compared with sampling done via radially resolved destructive sampling techniques. Generally, there is good agreement between profiles measured via destructive sampling of the rings and the tomographic profiles, though at low signal strengths, the tomographic profiles appear elevated.
Segmenting Images for a Better Diagnosis
NASA's Hierarchical Segmentation (HSEG) software has been adapted by Bartron Medical Imaging, LLC, for use in segmentation feature extraction, pattern recognition, and classification of medical images. Bartron acquired licenses from NASA Goddard Space Flight Center for application of the HSEG concept to medical imaging, from the California Institute of Technology/Jet Propulsion Laboratory to incorporate pattern-matching software, and from Kennedy Space Center for data-mining and edge-detection programs. The Med-Seg[TM] united developed by Bartron provides improved diagnoses for a wide range of medical images, including computed tomography scans, positron emission tomography scans, magnetic resonance imaging, ultrasound, digitized Z-ray, digitized mammography, dental X-ray, soft tissue analysis, and moving object analysis. It also can be used in analysis of soft-tissue slides. Bartron's future plans include the application of HSEG technology to drug development. NASA is advancing it's HSEG software to learn more about the Earth's magnetosphere.
Production of Medically Desirable Radioisotopes in the EIRENE Molten Salt Reactor
Radioisotopes play a vital role in nuclear medicine, enabling the performance of diagnostic procedures such as Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT), in addition to innovative targeted therapies for selectively delivering cytotoxic radiation doses to tumor cells while minimizing damage to healthy tissue [1]. Beta emitting radionuclides such as 90Y and 131I find wide use in radio-immunotherapy, with the radiopharmaceuticals 90Y-ibritumomab tiuxetan (Zevalin®) and 131I-tositumomab (Bexxar®) having received FDA approval for treatment of non-Hodgkin’s lymphoma through targeting the CD20 surface receptor, which is commonly expressed in many B cell non-Hodgkin’s lymphoma subtypes [2, 3]. 90Y has also been successfully applied for treatment of brain tumors [4, 5] and liver cancer [6]. The favorable chelation chemistry of 90Y enables its use with a variety of ligands for the development of radiopharmaceuticals suitable for targeting different carcinoma types [1].