Search NASA⌕ Search

SEARCH · Search NASA

Results for “Enclosures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Activation Analysis of Soil, Air and Water near the NSLS-II Accelerator Enclosures

The radiation environment in the accelerator enclosures is sufficiently high energy to permit the activation of air inside the accelerator enclosures, soil surrounding the concrete shielding of the enclosures and the coolant water used for cooling various components of the accelerator system like magnets etc. Bremsstrahlung is generated inside the accelerator enclosures by the radiative interaction of the electron beam with the accelerator components.

36 MATERIALS SCIENCE↗

Application of the relative energy release criteria to enclosure fire testing

The five relative energy release criteria (RERC) which are a first step towards formulating a unified concept that can be applied to the development of fires in enclosures, place upper bounds on the rate and amount of energy released during a fire. They are independent, calculated readily, and may be applied generally to any enclosure regardless of size. They are useful in pretest planning and for interpreting experimental data. Data from several specific fire test programs were examined to evaluate the potential use of RERC to provide test planning guidelines. The RERC were compared with experimental data obtained in full-scale enclosures. These results confirm that in general the RERC do identify the proper limiting constraints on enclosure fire development and determine the bounds of the fire development envelope. Plotting actual fire data against the RERC reveals new valid insights into fire behavior and reveals the controlling constraints in fire development. The RERC were calculated and plotted for several descrpitions of full-scale fires in various aircraft compartments.

Roschke, E. J.↗

Enclosure fire hazard analysis using relative energy release criteria

A method for predicting the probable course of fire development in an enclosure is presented. This fire modeling approach uses a graphic plot of five fire development constraints, the relative energy release criteria (RERC), to bound the heat release rates in an enclosure as a function of time. The five RERC are flame spread rate, fuel surface area, ventilation, enclosure volume, and total fuel load. They may be calculated versus time based on the specified or empirical conditions describing the specific enclosure, the fuel type and load, and the ventilation. The calculation of these five criteria, using the common basis of energy release rates versus time, provides a unifying framework for the utilization of available experimental data from all phases of fire development. The plot of these criteria reveals the probable fire development envelope and indicates which fire constraint will be controlling during a criteria time period. Examples of RERC application to fire characterization and control and to hazard analysis are presented along with recommendations for the further development of the concept.

Coulbert, C. D.↗

Development of a General Method for Determining Leak Rates from Limiting Enclosures

This paper discusses the development of a general method for the determination of very low leak rates from limiting enclosures. There are many methods that can be used to detect and repair leaks from enclosures. Many methods have also been proposed that allow the estimation of actual leak rates, usually expressed as enclosure volume turnover. The proposed method combines measurements of the state variables (pressure, temperature, and volume) as well as the change in the concentration of a tracer gas to estimate the leak rate. The method was applied to the containment enclosure of the Engineering Development Unit of the CELSS Test Facility, currently undergoing testing at the NASA Ames Research Center.

Zografos, A. I.↗

On the Maximum Expected Electric Field in Electrically Small, Undermoded Enclosures

This paper reports the experimental validation of an improved statistical model for the prediction of maximum expected electric field in electrically small and under-moded enclosures. The aerospace community is interested in application of Hill’s statistical models to design of avionics boxes for shielding effectiveness and for tailoring EMC test requirements for critical applications. However, it is observed that the probability distribution for mean-squared electric field (|E(sub x)|(exp 2)) in an electrically small enclosure differs from the exponential distribution which is widely used in reverberation chamber testing. It is postulated here that the difference is attributable to the under-moded character of the small enclosure. We will define “under-moded” as the condition where a single excitation frequency does not excite enough closely spaced resonant modes to achieve Hill’s assumption of an isotropic (or fully diffuse) plane wave field in the enclosure.

Bremner, P. G.↗

Advanced Modular Power System Fully Populated Electronics Enclosure Thermal Testing

A thermal test of an enclosure housing the AMPS electronics cards was performed. The enclosure was fully populated with 17 nonfunctioning AMPS electronics cards. Heaters were applied to the cards to simulate their operation. A cold plate was installed on the top of the case. The case was then insulated to simulate its installation within an electronics rack with the face and rear of the enclosure left open. The cold plate was connected to a chiller which provided cooling water at a fixed input temperature to the cold plate. Flow rates from the chiller of 0.0 L/min, 1.4 L/min and 1.8 L/min were tested. The test was operated at each flow rate over a range of heater power levels until the steady state temperature of the electronics cards was reached. Heater power levels from 2.5 W/card to 45 W/card were tested. The data collected was used to determine the steady state operating temperature of the cards, the temperature distribution between the cards, the time to reach steady-state temperature, the change in steady state temperature with change in heater power, the temperature distribution between the cards at the steady state condition and the heat lost to the surrounds by the enclosure. One of the main goals of the testing was to determine how much waste heat the cards could generate and still maintain a touch temperature at or below 40°C. Based on this requirement, for the 3 cooling rates tested, the maximum card waste heat that could be generated by each individual card was 3.9 W, 16.3 W and 17.6 W respectively. An analysis was also set up to provide an analytical model to estimate the card temperature under different cold plate flow rates and card heater power levels. The results off the analysis was compared to that of the experiment of the range of flow rates and power levels tested.

Anthony Colozza↗

Enclosure for light detection and ranging unit and related methods

This disclosure provides systems, methods, and apparatus related to light detection and ranging. In one aspect, a method comprises providing an apparatus. The apparatus comprises a LiDAR unit and a LiDAR enclosure. The LiDAR enclosure comprises a four-sided container having a square or rectangular cross-section with a first open end and a second open end comprising two opposite ends of the four-sided container. The LiDAR unit is attached to a mounting area inside the four-sided container. A reflective material is disposed on an interior of a second side and a third side of the four-sided container. Laser light is generated with the LiDAR unit. The laser light that has interacted with environment surrounding the LiDAR enclosure and that has been reflected back to the LiDAR unit is detected. The detected laser light is processed to construct an image of the environment surrounding the LiDAR enclosure.

Bandstra, Mark S.↗

Cask Processing Enclosure Specification/Operation - 12231

Following an evaluation of throughput rates in the Hot Cell at the Transuranic Waste Processing Center and considering the variability in the waste with respect to actual dose rates a new approach to processing transuranic waste was necessary. Compounding the issue was the remote equipment poor reliability and high down-time. After considering all the factors, the evaluation resulted in the design and construction of a new waste processing area for handling the concrete casks that predominately contain contact handled transuranic (TRU) waste. The area is called the Cask Processing Enclosure and essentially the Cask Processing Enclosure mimics the projects current process techniques used for processing Contact Handled -TRU waste in the existing Box Breakdown Area and Glovebox. The Cask Processing Enclosure approach was developed based on a review of the RH processing throughput rates in the Hot Cell. As the process was reviewed consideration was given to the variability in the waste with respect to actual dose rates and the lack of equipment reliability and high wear in the Hot Cell. Based on that review, a new contact handled processing area for handling the concrete casks is being constructed and startup is expected shortly following WM2012. The Cask Processing Enclosure essentially mimics the projects current process techniques used for processing Contact Handled waste in the existing Box Breakdown Area and Glovebox and the design takes into consideration six years of operational experience. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Finite Element Analysis and Machine Learning Guided Design of Carbon Fiber Organosheet-Based Battery Enclosures for Crashworthiness

Carbon fiber composite can be a potential candidate for replacing metal-based battery enclosures of current electric vehicles (E.V.s) owing to its better strength-to-weight ratio and corrosion resistance. However, the strength of carbon fiber-based structures depends on several parameters that should be carefully chosen. Here, in this work, we implemented high throughput finite element analysis (FEA) based thermoforming simulation to virtually manufacture the battery enclosure using different design and processing parameters. Subsequently, we performed virtual crash simulations to mimic a side pole crash to evaluate the crashworthiness of the battery enclosures. This high throughput crash simulation dataset was utilized to build predictive models to understand the crashworthiness of an unknown set. Our machine learning (ML) models showed excellent performance (R 2 > 0.97) in predicting the crashworthiness metrics, i.e., crush load efficiency, absorbed energy, intrusion, and maximum deceleration during a crash. We believe that this FEA-ML work framework will be helpful in down select process parameters for carbon fiber-based component design and can be transferrable to other manufacturing technologies.

36 MATERIALS SCIENCE↗

Effects of Protective Shell Enclosures on Uranium Adsorbing Polymers

Here, this study aims to evaluate the impact of shell enclosures on the uranium uptake of amidoxime-based polymeric adsorbents they contain. Researchers have observed that the tensile strength of the adsorbent’s polyethylene backbone is degraded after γ-irradiation to induce grafting of the amidoxime ligand. A two-part system was developed to decouple the mechanical and chemical requirements of the adsorbent by encapsulating them in a hard, permeable shell. The water flow in six shell designs and an unenclosed adsorbent for control in a recirculating flume was analyzed via a novel method developed using the measurement of radium extracted onto MnO 2 impregnated acrylic fibers. Although the water flow was found to vary with enclosure design, orien- tation to the flow, and placement within the flume, little to no difference was observed in the uranium adsorption rate between all enclosures. The results of this study will be used to design a large-scale ocean deployment of a uranium harvesting system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sound reduction by metamaterial-based acoustic enclosure

In many practical systems, acoustic radiation control on noise sources contained within a finite volume by an acoustic enclosure is of great importance, but difficult to be accomplished at low frequencies due to the enhanced acoustic-structure interaction. In this work, we propose to use acoustic metamaterials as the enclosure to efficiently reduce sound radiation at their negative-mass frequencies. Based on a circularly-shaped metamaterial model, sound radiation properties by either central or eccentric sources are analyzed by numerical simulations for structured metamaterials. The parametric analyses demonstrate that the barrier thickness, the cavity size, the source type, and the eccentricity of the source have a profound effect on the sound reduction. It is found that increasing the thickness of the metamaterial barrier is an efficient approach to achieve large sound reduction over the negative-mass frequencies. These results are helpful in designing highly efficient acoustic enclosures for blockage of sound in low frequencies.

36 MATERIALS SCIENCE↗

Numerical simulation of transient moisture transfer into an electronic enclosure

Electronic systems are sometimes exposed to harsh environmental conditions of temperature and humidity. Moisture transfer into electronic enclosures and condensation can cause several problems such as corrosion and alteration in thermal stresses. It is therefore essential to study the local climate inside the enclosures to be able to protect the electronic systems. In this work, moisture transfer into a typical electronic enclosure is numerically studied using CFD. In order to reduce the CPU-time and make a way for subsequent factorial design analysis, a simplifying modification is applied in which the real 3D geometry is approximated by a 2D axial symmetry one. The results for 2D and 3D models were compared in order to calibrate the 2D representation. Furthermore, simulation results were compared with experimental data and good agreement was found.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mixed convection flow of nanofluid in a square enclosure with an intruded rectangular fin

Mixed convection flow in enclosures has been a subject of interest for many years due to their ever increasing applications in solar collectors, electronic cooling, lubrication technologies, food processing, and nuclear reactors. In comparison, little effort has been given to the problem of mixed convection in enclosures filled with nanofluids, while the addition of nanoparticles in a fluid base to alter specific material properties is considered a feasible solution for many heat transfer problems. Mixed convection of nanofluids is a challenging problem as the addition of nanoparticles changes the fluid’s thermo-physical properties as well as due to the complex interactions among inertia, viscous, and buoyancy forces. In this study, a two-dimensional steady-state numerical model has been developed to investigate mixed convection flow of nanofluids in a square enclosure with an intruded rectangular fin and to optimize the fin geometry for maximizing the heat transfer using the Constructal design. The model has been developed using ANSYS-FLUENT for various fin geometries. Flow fields, temperature fields, and heat transfer rates are examined for different values of Rayleigh and Reynolds numbers for several geometries of the fin with the aim of maximizing the heat transfer from the fin to the surrounding flow. Outcome of this study provides important insight into the heat transfer behavior of nanofluids, which will help in developing novel geometries with enhanced and controlled heat transfer for solar collectors and electronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Benchmark analytical solutions for steady state high frequency broadband sound fields in three rectangular enclosures

Analytical solutions are presented for broadband sound fields in three rectangular enclosures with absorption applied on the floor and ceiling, rigid sidewalls, and a vertically oriented dipole source. The solutions are intended to serve as benchmarks that can be used to assess the performance of broadband techniques, particularly energy-based methods, in a relatively straightforward configuration with precisely specified boundary conditions. A broadband Helmholtz solution is developed using a frequency-by-frequency modal approach to determine the exact band averaged mean-square pressures along spatial trajectories within each enclosure. Due to the specific choice of enclosure configuration and absorption distribution, an approximate specular solution can be obtained through a summation of uncorrelated image sources. Comparisons between the band averaged Helmholtz solution and the uncorrelated image solution reveal excellent agreement for a wide range of absorption levels and improve the understanding of correlation effects in broadband sound fields. In conclusion, a boundary element solution with diffuse boundaries is also presented, which produces consistently higher mean-square pressures in comparison with the specular solution, emphasizing the careful attention that must be placed on correctly modeling reflecting boundary conditions and demonstrating the errors that can result from assuming a Lambertian surface.

42 ENGINEERING↗

Arc Weld Robotic Arm & Enclosure Seismic Anchorage in B226

The Arc Weld Robotic Arm & Enclosure is adequately anchored by the details shown on sheets SKS-01 through SKS-03. Two different Hilti anchors have been provided to allow for installation flexibility. Existing documentation shows that the existing enclosure base has been anchored with 5/8”Ø Kwik Bolt TZ’s. As a result, it is believed that the existing holes are sized for that 5/8”Ø anchor. The first option is to install a 5/8”Ø Kwik Bolt TZ2, similarly to the existing conditions. The second option is to use a threaded insert anchor. Since the largest allowable diameter of HIS-N insert is 1/2”Ø based on the slab thickness, 2”x2” square plate washers with a 9/16”Ø hole will need to be installed on the top of the existing enclosure base plates to reduce the diameter of the existing holes. This is required for the anchorage to provide proper restraint in a seismic event.

42 ENGINEERING↗

SPRUCE Enclosure Corral and Sump System: Description, Operation, and Calibration

This document describes the subsurface corral system that has been designed and constructed to measure water flow and allow the collection of water samples from the outflow of each experimental enclosure at the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site within the Marcell Experimental Forest in northern Minnesota, USA. SPRUCE implemented 10 years of whole-ecosystem warming, deep peat heating, and elevated carbon dioxide (CO2) treatments from 2015-2025 to assess the response of northern peatland ecosystems to increases in temperature and exposures to elevated atmospheric CO2 concentrations. This document: 1. Describes belowground corrals, sump systems, and the operation of sump systems, which are used to calculate the volumes of water that naturally drain enclosures and to trigger automatic collection of water samples; 2. Describes the calibration between water level and water volume in the sump system. This relationship is used to calculate near-surface lateral runoff (“outflow” in L/s) from each enclosure by measuring the change in water level over time. The water volume vs. water level relationship must be re-calibrated if water level sensors (or components) are replaced; and 3. Describes the data and data products that are and will be available from outflow measurements.

54 ENVIRONMENTAL SCIENCES↗

Radiative equilibrium in a rectangular enclosure bounded by gray walls

Two-dimensional temperature and heat-flux distributions are calculated for an absorbing-emitting gray medium at radiative equilibrium in a rectangular enclosure. The bounding walls are gray and diffuse with arbitrary surface-temperature distributions, and heat generation may take place inside the medium. As a first approximation, the problem is solved for optically thick systems (differential approximation). These results are subsequently improved by the introduction of a number of geometrical parameters to yield good accuracy for all optical thicknesses. As examples, two cases are discussed in detail: (1) uniform heat generation in a black enclosure, and (2) an enclosure with one gray surface at constant temperature. Comparison with some numerical solutions generated by Hottel's /Hottel and Cohen (1958) and Einstein (1963)/ zonal method shows excellent agreement.

Modest, M. F.↗

Tissue stimulator enclosure welding fixture

It was demonstrated that the thickness of the stimulator titanium enclosure is directly related to the battery recharge time cycle. Reduction of the titanium enclosure thickness from approximately 0.37 mm (0.015 inch) to 0.05 mm (0.002 inch) significantly reduced the recharge time cycle and thereby patient inconvenience. However, fabrication of titanium enclosures from the thinner material introduced problems in forming, holding, and welding that required improvement in state of the art shop practices. The procedures that were utilized to resolve these fabrication problems are described.

Mcclure, S. R.↗