Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Technoeconomic and life cycle energy analysis of carbon fiber manufactured from coal via a novel solvent extraction process

Coal is a versatile energy resource and was a driver of the industrial revolution that transformed the economies of Europe and North America and the trajectory of civilization. In this work, a technoeconomic analysis was performed for a coal-to-carbon-fiber manufacture process developed at the University of Kentucky’s Center for Applied Energy Research. According to this process, coal, with decant oil as the solvent, was converted to mesophase pitch via solvent extraction, and the mesophase pitch was subsequently converted to carbon fiber. The total cost to produce carbon fibers from coal and decant oil via the solvent extraction process was estimated to be $\$$11.50/kg for 50,000-tow pitch carbon fiber with a production volume of 3750 MT/year. The estimated carbon fiber cost was significantly lower than the current commercially available PAN-based carbon fiber price ($\$$20–$\$$30/kg). With decant oil recycling rates of 50% and 70% in the solvent extraction process, the manufacturing cost of carbon fiber was estimated to be $\$$9.90/kg and $\$$9.50/kg of carbon fiber, respectively. A cradle-to-gate energy assessment revealed that carbon fiber derived from coal exhibited an embodied energy of 510 MJ/kg, significantly lower than that of conventionally produced carbon fiber from PAN. This notable difference is primarily attributed to the substantially higher conversion rate of coal-based mesophase pitch fibers into carbon fiber, surpassing PAN fibers by 1.6 times. These findings indicate that using coal for carbon fiber production through solvent extraction methods could offer a more energy-efficient and cost-competitive alternative to the traditional PAN based approach.

01 COAL, LIGNITE, AND PEAT↗

NREL Data, Modeling, and Tools Empower Marine Energy Analysis

NREL performs R&D and economic analyses to drive and empower the development of wave energy and tidal, ocean, and river current energy technologies. These technologies deliver renewable electricity to the grid and provide energy solutions that support the evolving "blue economy."

HYDRO ENERGY↗

Retrofit Energy Analysis and Central Thermal modeling (REACT) v1.0

REACT is a website designed to simplify the analysis and decision-making process for retrofitting existing central plant heating and cooling systems with advanced heat pump technologies. The tool evaluates the technical and economic viability of replacing traditional boilers with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. Retrofitting traditional boiler and chiller systems with water-to-water or air-to-water heat pumps can significantly reduce energy consumption and lower lifecycle costs. The REACT provides: User-Friendly Tools: A user friendly web interface for quick, intuitive analysis accessible to non-experts. Advanced Modeling: A Python-powered engine for detailed parametric studies, optimization, and research applications. Comprehensive Analysis: Lifecycle cost evaluation, energy consumption modeling, and environmental impact assessment. Visual Insights: A variety of plots to visualize system performance and design trade-offs. The engine for the website (REACT) bases on several Python libraries, and the website will be hosted on an ETA server.

Kim, Donghun [Lawrence Berkeley National Laborator↗

Traveling Wave Energy Analysis of Faults on Power Distribution Systems

This paper explores the most important factors that define the Traveling Wave (TW) propagation on distribution systems. The factors considered in this work are: the distance to the fault location, the fault type, and the crossing of system elements (such as regulators, capacitor banks, laterals, and extra loads within the protection zones). This work uses a realistic, yet simplified, distribution system composed of two protection zones, in which, several combinations of the previously mentioned factors are considered. The simulated fault measurements undergo a signal processing stage in which, first, they are decomposed into independent modes using the Karrenbauer transform. Second, a time–frequency representation is obtained using the Stationary Wavelet Transform (SWT), dividing the signal into several frequency bands. Finally, the Parseval’s Energy (PE) theorem is applied to calculate the signal energy in each frequency band. A qualitative analysis is performed based on the previously calculated energies to outline which are the factors that most affect the TW energy during propagation. The results show that distance, the presence of regulators, either in the propagation path or upstream, and the type of fault are the main factors that affect TW propagation across the system, and therefore they should be considered for TW-based protection schemes for distribution systems.

Jiménez-Aparicio, Miguel (ORCID:000000016864461X)↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Energy Analysis of Refrigeration Systems in Supermarkets: A Case Study

Refrigeration systems are the single largest consumer of electricity in supermarkets, accounting for approximately 40–60% of total store electricity use. As supermarkets face increasing pressures to improve efficiency and reduce operational costs, understanding the energy performance of refrigeration systems in supermarkets has become essential. In this paper, we investigate the energy performance and patterns of the refrigeration system using field measurements in one supermarket. The compressor coefficient of performance (COP) averaged 4.5 during nighttime steady-state operation, providing a practical efficiency benchmark. We develop simple physical-based load models for the display cases in the supermarket, where the refrigeration system uses R404A. The results show the display case models achieve a good agreement with measured data, validating its utility for energy estimation during unoccupied hours. Finally, the analysis reveals several challenges of data collection systems for refrigeration systems in the supermarket industry as well.

Chen, Yimin [ORNL] (ORCID:0000000338181655)↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Exploring New Ways to Classify Industries for Energy Analysis and Modeling

As the US moves closer to embracing a net zero greenhouse gas emissions position, combustion processes outside the power sector are becoming urgent concerns. Industry is an important end user of energy and relies on fossil fuels used directly for process heating and as feedstocks for a diverse range of applications. Fuel and energy use by industry is heterogeneous, meaning that even a single product group can vary broadly in its production routes and associated energy usage. In the US, the North American Industry Classification System (NAICS) serves as the basis for data collection and reporting. In turn, data based on NAICS is the foundation of most US energy modeling. Thus, the effectiveness of NAICS at representing energy use is a limiting condition for plans to improve energy efficiency and alternatives to fossil fuels in industry. Facility-level data to build more detail into heterogeneous sectors is scarce. This work explores alternative classification schemes for industry based on energy use characteristics, and provides a validation of an approach to make facility-level energy use estimates based on publicly available data from the greenhouse gas reporting program. First, several approaches to industrial taxonomies and their usefulness for industrial energy modeling are summarized. Data from Industrial Assessment Centers is analyzed using unsupervised machine learning techniques to detect clusters. Cladistics, an approach from biology, is adapted to energy and process characteristics of industries. A cladogram is presented for evolutionary directions in the iron and steel sector. Cladograms are a promising tool for constructing scenarios and summarizing directions of sectoral innovation. Finally, validation is performed for facility-level energy estimates from the US EPA Greenhouse Gas Reporting Program. This validation assists in making this data source available for use in energy modeling. Together, this work explores alternative approaches for categorizing industries in a way that aids understanding energy use, and presenting pathways for the future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Time-of-Flight Calculations with Multiple Beam Phase Monitors: Calibration, Jitter Analysis & Energy Measurement

This report describes time-of-flight (ToF) beam energy measurements with multiple phase monitors in a beam line with no acceleration. Measurement uncertainty is quantified via rigorous treatment of beam-based phase monitor calibration and jitter analysis of the accelerator system. Experimental results in the Superconducting Linac (SCL) of the Spallation Neutron Source (SNS) are presented.

43 PARTICLE ACCELERATORS↗

Economic and embodied energy analysis of integrated circuit manufacturing processes

Integrated circuits (ICs) are the fundamental microelectronic building blocks of typical information and communication technology (ICT) devices such as laptops and smartphone. With the emergence of faster and cheaper low-power ICs for the growing ICT market, there is a limited information on their manufacturing energy and economic impacts owing to the lack of recurrent upgradation of proprietary IC manufacturing process data. In this work, economic and life cycle energy assessments (LCAs) of IC manufacturing and assembly processes were conducted using the latest bill of materials (BOM) manufacturing data in a state-of-the-art IC manufacturing cost software tool developed by IC Knowledge, LLC. IC manufacturing cost was estimated to be $\$$1.00-$\$$5.00/cm 2 ; the high-end cost represents the most advanced 3D NAND IC technology with the Wafer Level Chip Scale Package cost of $4/cm 2 . Total cumulative energy demand (CED) estimates of IC manufacturing using the OpenLCA software ranged from 9 to 38 MJ/cm 2 or 56–235 BJ/month with the largest share (~ 75%) from on-site energy. The IC manufacturing CED is projected to increase with the progress in IC technology node, which has increased by more than two times for technology node evolution from 110 to 14 nm. Furthermore, the representative detailed BOM data were considered to reduce the CED uncertainties of the estimated standard deviation of 35%- 42%.

97 MATHEMATICS AND COMPUTING↗

Method and apparatus for shape-based energy analysis of solids

A computer-readable medium stores instructions including storing a model of a physical structure and defining a mesh for the model. The mesh includes finite elements, each defined by a respective set of edges. The instructions include, for each finite element, identifying a governing differential equation and a set of complementary functions that exactly satisfy the governing differential equation. The instructions include determining an applied physical stimulus for the physical structure. The instructions include generating an energy optimization model that minimizes a difference between internal energy and external energy of the finite elements in response to the applied physical stimulus. The model includes a matrix of respective scalar multipliers for the complementary functions for each finite element. The instructions include transforming the matrix and calculating a physical parameter of interest. The instructions include, in response to the physical parameter not satisfying a design parameter, updating the model of the physical structure.

Spears, Robert E.↗

Binding Free Energy Analysis of Colicin D, E3 and E8 to Their Respective Cognate Immunity Proteins Using Computational Simulations

Colicins are antimicrobial proteins produced by bacteria for the purpose of destroying neighboring bacteria. Colicin activity is neutralized by a specific cognate immunity protein in order to protect the host. This study investigates the structural and binding mechanisms underlying the interaction of colicin-D, -E3 and -E8 to their respective immunity proteins (ImD, Im3 and Im8) using structure prediction, molecular dynamics (MD) simulations and MM-PBSA approach of free energy calculations. High-confidence colicin-immunity (Col-Im) complex structures predicted using AlphaFold2 were subjected to MD simulations of 150 ns with GROMACS and were analyzed for the binding free energy calculation using gmx_MMPBSA. Results showed that the complex of Col_E3-Im3 exhibited the most favorable binding free energy, driven by strong van der Waals and electrostatic interactions. Col_D-ImD and Col_E8-Im8 also showed the favorable binding. Electrostatics and hydrogen bonding emerged as a key factor driving binding and stability, while polar solvation acted as a destabilizing factor across all systems. These outcomes provide an understanding of the molecular mechanisms of Col-Im systems, with potential applications for developing natural antimicrobials for food safety.

Biochemistry & Molecular Biology↗

Free-energy analysis of the nonhysteretic first-order phase transition of Eu 2 In

Binary intermetallic Eu 2 In was recently reported to exhibit a giant anhysteretic magnetocaloric effect due to a first-order magnetic phase transition between paramagnetic and ferromagnetic states. Experimentally, the transition occurs with a small phase volume change, ΔV/V, of approximately 0.1% around T C of ca. 55 K. We representmagnetic and computemagnetocaloric properties of a Eu 2 In compound using a microscopic description based on a model Hamiltonian that takes into account magnetic exchange and magnetoelastic interactions. In the model the thermodynamic nature of the transition is conveniently represented by a single magnetoelastic interaction parameter. We report a good agreement between the theoretical results and earlier published experimental data confirms the effectiveness of our approach.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

IHS-60 Stored Energy Analysis

The IHS-60 consists of a General Purpose Heat Source (GPHS) Fueled Clad (FC) that has been hot isostatically pressed to eliminate the gap between the iridium clad and the fuel pellet, thus preventing differential motion between the pellet and the clad in shock and vibration environments. The vented FC is enclosed within a Molybdenum barrier comprising the liner body and the lower support member. The slip- t Molybdenum liner members serve as a mechanical barrier to plutonia contact of the tantalum alloy (T-111) strength member in the event the iridium clad should fail. The slip- t liner is not a barrier to gaseous transport, so a tantalum getter is installed near the vent region of the FC to preclude potential oxygen transport to the T-111 interior surface. The T-111 strength member encloses the Molybdenum liner assembly and provides for both helium gas retention and isotope fuel containment under impact and external pressure environments. It is surrounded by an outer clad of Hastelloy-S which protects the strength member from external oxidation and corrosive sources during nominal operation and in the event of off-nominal operation or accidents. Both the strength member and outer clad parts are closed with seal welds. The strength member and outer clad are the primary containment members of the 60-Watt IHS. The iridium clad contains the fuel pellet during nominal operation and mild accident environments, but it is not considered to be a primary containment member.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗