Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy-Dispersive Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Purification Procedures for Single-Wall Carbon Nanotubes

This report summarizes the comparison of a variety of procedures used to purify carbon nanotubes. Carbon nanotube material is produced by the arc process and laser oven process. Most of the procedures are tested using laser-grown, single-wall nanotube (SWNT) material. The material is characterized at each step of the purification procedures by using different techniques including scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), Raman, X-ray diffractometry (XRD), thermogravimetric analysis (TGA), nuclear magnetic resonance (NMR), and high-performance liquid chromatography (HPLC). The identified impurities are amorphous and graphitic carbon, catalyst particle aggregates, fullerenes, and hydrocarbons. Solvent extraction and low-temperature annealing are used to reduce the amount of volatile hydrocarbons and dissolve fullerenes. Metal catalysts and amorphous as well as graphitic carbon are oxidized by reflux in acids including HCl, HNO3 and HF and other oxidizers such as H2O2. High-temperature annealing in vacuum and in inert atmosphere helps to improve the quality of SWNTs by increasing crystallinity and reducing intercalation.

Gorelik, Olga P.↗

Micro Electron MicroProbe and Sample Analyzer

A proposed, low-power, backpack-sized instrument, denoted the micro electron microprobe and sample analyzer (MEMSA), would serve as a means of rapidly performing high-resolution microscopy and energy-dispersive x-ray spectroscopy (EDX) of soil, dust, and rock particles in the field. The MEMSA would be similar to an environmental scanning electron microscope (ESEM) but would be much smaller and designed specifically for field use in studying effects of geological alteration at the micrometer scale. Like an ESEM, the MEMSA could be used to examine uncoated, electrically nonconductive specimens. In addition to the difference in size, other significant differences between the MEMSA and an ESEM lie in the mode of scanning and the nature of the electron source.

Manohara, Harish↗

Flight Readiness of Mochii ISS-NL Portable Spectroscopic Electron Microscope

Electron microscopes (EM’s), are workhorse tools serving diverse fields such as materials science, biological science, and engineering. Scanning EM’s (SEM’s) in particular enable high magnification study and pinpoint chemical analyses of structures down to the nanoscale by providing a powerful blend of strong optical scattering, high native resolution, large depth of focus, and energy-dispersive X-ray spectroscopy (EDS). Mochii is the world’s smallest production electron microscope, scheduled to travel to the International Space Station (ISS) this spring where it will serve as an ISS National Laboratory (ISSNL) microgravity facility on successful demonstration. We previously reported on progress preparing Mochii for space flight, in particular flight integration verifications and science application testing. These included standard integration testing such as electromagnetic interference and flight vibration, and extend to unique functional testing such as magnetic susceptibility and extreme analog environment testing under the sea. Presently, Mochii payload flight hardware has completed testing and was handed over to NASA’s ISS payload processing facility in Houston. It will make its way to the the east coast for launch currently scheduled on Space-X CRS-20 for Mission increment 62 in March 2020.

Own, C. S.↗

A Transmission Electron Microscopy Study of a Refractory Metal Grain from a Calcium-Aluminum-Rich Inclusion in the Leoville CV3 Chondrite

Introduction: Calcium-aluminum-rich inclusions (CAIs) are an important component of chondritic meteorites. They can contain materials that are thermodynamically predicted and isotopically age dated to be among the first-formed solids in our solar system [1-5]. Observed in some CAIs are micron to sub-micron sized inclusions rich in Fe, Ni, and high-Z elements such as Pt, Os, Ir and W, in the form of refractory metal nuggets (RMNs), fremdlinges, and ‘nugget like objects’ (NLOs) [1,6]. Refractory siderophile elements such as Os, Ir and Ru are thermodynamically predicted to condense at temperatures well in excess of the major CAI phases such as melilite, perovskite, spinel and hibonite [2,7-9]. These refractory metal inclusions in CAIs can therefore serve as probes into the thermodynamic landscape of the early solar protoplanetary disk. Here we report on a refractory grain identified in a CAI of the Leoville CV3 chondrite. This work is part of an ongoing effort to gain insight into the thermochemistry of the early solar system through systematic analyses of the structure and chemistry of various components in CAIs [10-13]. Sample and Analytical Techniques: A fluffy type A CAI (Fig. 1A) was identified in a section of the Leoville, CV3 chondrite (Center for Meteorite Studies, Arizona State University collection, #821_C_3) using a JOEL-JXA 8530F electron microprobe at Arizona State University. Backscattered electron (BSE) imaging and energy-dispersive X-ray spectroscopy (EDS) were used to identify refractory metal grains in the CAI using a Thermo Fisher (formerly FEI) Helios NanoLab 660 G3 focused-ion-beam scanning-electron microscope (FIBSEM) located at the Kuiper Materials Imaging and Characterization Facility (KMICF) at the Lunar and Planetary Laboratory, University of Arizona. The FIB is equipped with an EDAX EDS system. We selected one of the larger (micron-sized) refractory metal grains, designated as ‘Spud’ (Fig. 1B) for further analysis. ‘Spud’ was extracted and thinned to electron transparency (<100 nm) using the FIB-SEM located in KMICF, following methods described by [14- 15]. The FIB section was analyzed using a 200 keV Hitachi HF5000 scanning transmission electron microscope (S/TEM) located at KMICF. The HF5000 is equipped with cold-field emission gun, 3rd-order spherical aberration corrector for STEM imaging, and an Oxford Instruments X-Max N 100 TLE energydispersive spectroscopy (EDS) system with dual 100 mm2 windowless silicon-drift detectors (Ω = 2.0 sr). Selected-area electron-diffraction (SAED) patterns were acquired to aid in determination of crystallinity and phase. Results: The mineralogy, texture, and morphology of the CAI are consistent with that of a fluffy type A (FTA) CAI [16]. BSE imaging at high magnifications revealed grains with high contrast, indicative of compositions rich in elements of higher atomic number relative to surrounding material. These high-Z grains have sizes that range from ∼250 nm to 4 µm. EDS analyses confirm that the bright grains are metal-rich inclusions. A minor fraction of the grains are composed of only Fe and Ni, but the majority (∼60%) of the identified inclusions also contained various refractory siderophiles including Os, Ru, Zr, Ir and Mo. EDS analysis on the FIB-SEM of Spud shows that it contains Fe, Ni, Mo and Ru. High-angle annular dark-field (HAAFD) imaging and EDS mapping in the TEM (Fig. 2) show that Spud occurs in melilite (Ca1.9Al1.99Si1.06O7). Spud contains a subhedral to anhedral morphology and is compositionally heterogenous (polyphasic, Fig. 2). Local spatial correlation occurs among Fe, Ni, and Pt, and also among Os, Ru, and Mo. SAED patterns show that the Fe-Ni-Pt, Fe-Os-Mo-Ru and Fe-Pt regions are crystalline. Discussion: CAIs can contain various types of inclusions rich in Fe, Ni and refractory siderophiles such as Os, Ru, W and Pt [1]. RMNs are micron-sized, single phase alloy grains and can contain Os, Ir, Ru and Rh [1,7,17]. NLOs are also micron-sized inclusions, but contain two phases, a refractory metal, and an oxide [6]. Fremdlinge are the largest of such inclusions (tens of microns in size) and are complex aggregates of Fe-Ni alloy, silicates, oxides, and sulfides [1,17]. While the size of Spud matches previous descriptions of RMNs and NLOs, Spud is neither a single-phase alloy like RMNs, nor does it contain one metal phase and one oxide like NLOs. Spud does not match the above described categories of refractory metal inclusions. The presence of refractory siderophiles such as Mo, Os, Ru, and Pt suggests a high-temperature origin. Thermodynamic modelling by [7] indicates condensation temperatures of 1917 K, 1693 K, 1613 K and 1415 K for Os, Mo, Ru and Pt respectively. These models also show that following the initial condensation of a refractory metal, alloying of solutes such as Fe, Ni and W, occurs in levels proportional to their partial pressures in the surrounding gas. Such alloying occurs at temperatures above the condensation temperatures of common CAI phases such as melilite (1529 K), perovskite (1441 K), spinel (197 K) and forsterite (1354 K) [2]. The polyphasic nature of Spud could be the result of such high-temperature alloying, possibly shortly after the condensation of Mo and Ru at 1693 K and 1613 K respectively. That Spud occurs as an inclusion is consistent with it having formed prior to and at temperature above that of its host melilite in this FTA CAI, which is qualitatively consistent with such prior thermodynamic modeling. Further, the polyphasic nature of Spud is similar to refractory grains from a FTA CAI in the Northwest Africa (NWA) 8323, CV3 chondrite [11-13]. These data suggest that such refractory metal grains could have been widespread in the inner and early solar protoplanetary disk and represent some of the earliest formed solids to have condensed. Acknowledgments: Research and instrumentation supported by NASA grants #NNX12AL47G, #NNX15AJ22G and #80NSSC19K0509, and NSF grants #1531243 and #0619599. Fig 2. STEM data on ‘Spud’. HAADF Image (Top) False-color EDS Maps (Bottom) References: [1] MacPherson G. J. (2014) T. of Geochem. Vol I: Met. And Cosmochem. Processes, 139-179. [2] Lodders K. (2003) ApJ, 591, 1220-1247. [3] Ebel D. S. (2006) Met. & the Early S. Sys. II., 253- 277. [4] Amelin Y. (2002) Science, 297, 1678-1683. [5] Connelly J.N. et.al. (2012) Science, 338, 651-655. [6] Schwander D. et al. (2015) GCA, 18, 70-87. [7] Palme H. and Wlotzka F. (1976) EPSL, 33, 45-60. [8] Berg T. et al. (2009) ApJ, 702, 172-176. [9] Liffman K. et al. (2021) Icarus, 221, 89-105. [10] Zega T.J. et al. (2021) PSJ, 2, 115. [11] Ramprasad T. et al. (2020) LPSC LI, Abstract #2472. [12] Ramprasad T. et al. (2021) Microscopy & Microanalysis, S1, 2792-2794. [13] Ramprasad T. et al. (2021) 84th MetSoc, Abstract #6123. [14] Zega T.J. et al. (2007) MAPS, 42, 1373-1386. [15] Ramprasad T. et al. (2022) MAPS, in revision. [16] Grossman L. (1975), GCA, 39, 433-454. [17] El Goresy A. et al. (1978) LPSC IX, Abstract#1100

T. Ramprasad↗

Advanced TUFROC Thermal Protection System Evolution Under Re-entry like Conditions

Toughened Unipiece Fibrous Reinforced Oxidation-resistant Composite (TUFROC) and its successor, Advanced TUFROC, are state-of-the-art thermal protection systems (TPS) for high temperature reusable applications. Originally designed for use on the wing-leading edge of X-37B, TUFROC is an insulative tiled system consisting of a low-conductivity ceramic base, a carbonaceous cap, and multiple coatings for thermal performance. The improved Advanced TUFROC has demonstrated reusability up to 2900 °F and single use capabilities exceeding 3200 °F. This effort explores the evolution of Advanced TUFROC when exposed to re-entry like conditions via arc jet testing. Chemical reactions and constituent migration resulting from the aerothermal heating are known to occur and are studied in detail. Further, the interaction between the multiple constituents and layers will be discussed as this is believed to have a significant impact on the overall performance. Characterization includes structural analysis via optical microscopy, scanning electron microscopy and energy-dispersive x-ray spectroscopy.

Thermal protection system↗

A Mossbauer investigation of iron-rich terrestrial hydrothermal vent systems: lessons for Mars exploration

Hydrothermal spring systems may well have been present on early Mars and could have served as a habitat for primitive life. The integrated instrument suite of the Athena Rover has, as a component on the robotic arm, a Mossbauer spectrometer. In the context of future Mars exploration we present results of Mossbauer analysis of a suite of samples from an iron-rich thermal spring in the Chocolate Pots area of Yellowstone National Park (YNP) and from Obsidian Pool (YNP) and Manitou Springs, Colorado. We have found that Mossbauer spectroscopy can discriminate among the iron-bearing minerals in our samples. Those near the vent and on the surface are identified as ferrihydrite, an amorphous ferric mineraloid. Subsurface samples, collected from cores, which are likely to have undergone inorganic and/or biologically mediated alteration (diagenesis), exhibit spectral signatures that include nontronite (a smectite clay), hematite (alpha-Fe2O3), small-particle/nanophase goethite (alpha-FeOOH), and siderite (FeCO3). We find for iron minerals that Mossbauer spectroscopy is at least as efficient in identification as X-ray diffraction. This observation is important from an exploration standpoint. As a planetary surface instrument, Mossbauer spectroscopy can yield high-quality spectral data without sample preparation (backscatter mode). We have also used field emission scanning electron microscopy (FESEM), in conjunction with energy-dispersive X ray (EDX) fluorescence spectroscopy, to characterize the microbiological component of surface sinters and the relation between the microbiological and the mineralogical framework. Evidence is presented that the minerals found in these deposits can have multi-billion-year residence times and thus may have survived their possible production in a putative early Martian hot spring up to the present day. Examples include the nanophase property and the Mossbauer signature for siderite, which has been identified in a 2.09-billion-year old hematite-rich chert stromatolite. Our research demonstrates that in situ Mossbauer spectroscopy can help determine whether hydrothermal mineral deposits exist on Mars, which is significant for exobiology because of the issue of whether that world ever had conditions conductive to the origin of life. As a useful tool for selection of samples suitable for transport to Earth, Mossbauer spectroscopy will not only serve geological interests but will also have potential for exopaleontology.

NASA Discipline Exobiology↗

SIMS chemical and isotopic analysis of impact features from LDEF experiments AO187-1 and AO187-2

Previous secondary ion mass spectrometry (SIMS) studies of extended impact features from LDEF capture cell experiment AO187-2 showed that it is possible to distinguish natural and man-made particle impacts based on the chemical composition of projectile residues. The same measurement technique has now been applied to specially prepared gold target impacts from experiment AO187-1 in order to identify the origins of projectiles that left deposits too thin to be analyzed by conventional energy-dispersive x-ray (EDX) spectroscopy. The results indicate that SIMS may be the method of choice for the analysis of impact deposits on a variety of sample surfaces. SIMS was also used to determine the isotopic compositions of impact residues from several natural projectiles. Within the precision of the measurements all analyzed residues show isotopically normal compositions.

Stadermann, Frank J.↗

An ET Origin for Stratospheric Particles Collected during the 1998 Leonids Meteor Shower

On 17 November 1998, a helium-filled weather balloon was launched into tfle strato- sphere, equipped with a xerogel microparticle collector. The three-hour flight was designed to sample the dust environment in the stratosphere during the Leonid meteor shower, and possibly to capture Leonid meteoroids. Environmental Scanning Election Microscope analyses of the returned collectors revealed the capture of a -30-pm particle. with a smooth, multigranular shape, and partially melted, translucent rims; similar to known Antarctic micrometeorites. Energy-dispersive X-ray Mass Spectroscopy shows en- riched concentrations of the non-volatile elements, Mg, Al, and Fe. The particle possesses a high magnesium to iron ratio of 2.96, similar to that observed in 1998 Leonids meteors (Borovicka, et al. 1999) and sharply higher than the ratio expected for typical material from the earth's crust. A statistical nearest-neighbor analysis of the abundance ratios Mg/Si, Al/Si, and Fe/Si demonstrates that the particle is most similar in composition to cosmic spherules captured during airplane flights throucrh the stratosphere. The mineralogical class is consistent with a stony (S) type of silicates. olivine [(Mg, Fe)2SiO4] and pyroxene [(Mg,Fe)SiO3]-or oxides, herecynite [(Fe,Mg) Al2O4]. Attribution to the debris stream of the Leonids' parent body, comet Tempel-Tuttle, would make it the first such material from beyond the orbit of Uranus positively identified on Earth.

Noever, David A.↗

Surface composition of solid-rocket exhausted aluminum oxide particles

Particulate samples of aluminum oxide were collected on Teflon filters from the exhaust plume of the Space Shuttle (STS-61A, October 30, 1985) over the altitude interval 4.6-7.6 km immediately after launch. These particles were analyzed using SEM, energy-dispersive X-ray analysis, electron spectroscopy for chemical analysis, X-ray fluorescent spectroscopy, and conventional wet-chemical techniques. The samples were 0.6-1.0 percent surface-chlorided (chlorided meaning predominantly aluminum chlorides and oxychlorides, possibly including other adsorbed forms of chloride) by weight. This level of chloriding is about one-third of the amount determined previously from laboratory-prepared alumina and surface site samples of solid-rocket-produced alumina (SRPA) after both had been exposed to moist HCl vapor at temperatures down to ambient. This level is equivalent to previous laboratory results with samples exposed to moist HCl at temperatures above the boiling point of water. It is suggested that the present lower chloriding levels, determined for samples from a 'dry' Shuttle exhaust cloud, underscore the importance of a liquid water/hydrochloric acid phase in governing the extent of surface chloriding of SRPA. The reduced chloriding is not trivial with respect to potential physical/chemical modification of the SRPA particle surfaces and their corresponding interaction with the atmosphere.

Cofer, Wesley R., III↗

Metal-organic chemical vapour deposition of polycrystalline tetragonal indium sulphide (InS) thin films

The dimeric indium thiolate /(t Bu)2In(mu-S sup t Bu)/2 has been used as a single-source precursor for the MOCVD of InS thin films. The dimeric In2S2 core is proposed to account for the formation of the nonequilibrium high-pressure tetragonal phase in the deposited films. Analysis of the deposited films has been obtained by TEM, with associated energy-dispersive X-ray analysis and X-ray photoelectron spectroscopy.

Macinnes, Andrew N.↗

Corrosion Failure in Electronic Devices for Aerospace Application

Corrosion of complex electronic systems is a growing and expensive concern. New materials and technology are constantly being introduced to increase performance of devices. There are many factors that can induce a corrosive environment during the various stages of manufacturing, processing, transport, and storage of these devices. The scope of this paper was to identify potential causes for the corrosion failure of optocoupler batches being used in launch applications. Optical microscope with surface profile measurements, scanning electron microscopy (SEM), energy-dispersive X-ray spectrometry (EDS), and X-ray photoelectron spectroscopy (XPS) were used to identify and analyze the source of these failure. These studies revealed that the loss of adhesion between the electrolytic plated gold and nickel layers is the critical area that traps impurity ions into the chip allowing for blisters to form along the pins of the optocoupler.

Corrosion↗

Comprehensive Study of Hydrated IDPs: X-Ray Diffraction, IR Spectroscopy and Electron Microscopic Analysis

Chondritic hydrated interplanetary dust particles (IDPs) comprise up to 50% of all IDPs collected in the stratosphere(1). Although much is known about the mineralogy, chemistry and carbon abundance of hydrated IDPs (2-4) controversies still exist regarding their formation, history, and relationship to other primitive solar system materials. Hydrated IDPs are generally believed to be derived from asteroidal sources that have undergone some degree of aqueous alteration. However, the high C contents of hydrated IDPs (by 2 to 6X CI levels (3,4) indicate that they are probably not derived from the same parent bodies sampled by the known chondritic meteorites. We report the comprehensive study of individual hydrated IDPs. The strong depletion in Ca (I) has been used as a diagnostic feature of hydrated IDPs. The particles are embedded in elemental sulfur or low viscosity epoxy and ultramicrotomed thin sections are observed using a transmission electron microscope (TEM) equipped with an energy-dispersive X-ray detector (EDX) followed by other measurements including: 1) FTIR microspectroscopy to understand the significant constraints on the organic functionality and the nature of the C-bearing phases and 2) powder X-ray difiaction using a synchrotron X-ray source to understand the bulk mineralogy of the particles.

Nakamura, K.↗

Identification and characterization of extraterrestrial non-chondritic interplanetary dust

Interplanetary dust particles (IDPs) are among the most pristine and primitive extraterrestrial materials available for direct study. Most of the stratospheric particles selected for study from the JSC Curatorial Collection were chondritic in composition (major element abundances within a factor of two of chondritic meteorites) because this composition virtually ensures that the particle is from an extraterrestrial source. It is likely that some of the most interesting classes of IDP's have not been recognized simply because they are not chondritic or do not fit established criteria for extraterrestrial origin. Indeed, mass spectroscopy data from the Giotto Flyby of comet Halley indicate that a substantial fraction of the dust is in the submicron size range and that a majority of these particles contain C, H, O, and/or N as major elements. The preponderance of CHON particles in the coma of Halley implies that similar particles may exist in the JSC stratospheric dust collection. However, the JSC collection also contains a variety of stratospheric contaminants from terrestrial sources which have these same characteristics. Because established criteria for extraterrestrial origin may not apply to such particles in individual cases, and integrated approach is required in which a variety of analysis techniques are applied to the same particle. Non-chondritic IDP's, like their chondritic counterparts, can be used to elucidate pre- and early solar system processes and conditions. The study of non-chondritic IDP's may additionally yield unique information which bears on the nature of cometary bodies and the processing of carbonaceous and other low atomic number materials. A suite of complementary techniques, including Low Voltage Scanning Electron Microscopy (LVSEM), Energy-Dispersive X-ray Microanalysis (EDX), Secondary Ion Mass Spectrometry (SIMS) isotope-ratio imaging and Analytical Electron Microscopy (AEM), were utilized to accomplish the following two objectives: (1) to develop criteria for the unequivocal identification of extraterrestrial non-chondritic IDP's; and (2) to infer IDP parent body, solar nebula, and pre-solar conditions through the study of phases, textures, and components contained within non-chondritic IDP's. The general approach taken is designed to maximize the total information obtained from each particle. Techniques will be applied in order from least destructive to most destructive.

Blake, D. F.↗

Applicability of Micro X-Ray Fluorescence Spectroscopy to Astromaterials Curation and Research

Introduction: The Astromaterials Acquisition and Curation Office at NASA’s Johnson Space Center (JSC) curates NASA’s astromaterial sample collections which includes: Apollo samples, Luna samples, Ant-arctic meteorites, cosmic dust particles, microparticle impacts into space-flown materials, Genesis solar wind atoms, Stardust comet Wild-2 particles, Stardust inter-stellar particles, Hayabusa asteroid Itokawa particles, Hayabusa 2 asteroid Ryugu particles, and future OSIRIS-Rex asteroid Bennu particles (landing in Sep-tember, 2023) [1–3]. To enhance JSC’s advanced cu-ration capabilities, we have recently installed a high-performance micro-X-ray fluorescence (µXRF) spec-trometer to assist in sample characterization through rapid, non-destructive, in-situ elemental analyses that do not require the sample preparation protocols (i.e., polishing and carbon-coating) commonly needed for electron beam analyses. With this new instrument, we are capable of detecting all elements down to carbon in a variable-pressure or He-purged chamber for anal-ysis of a wide range of sample types. Here we describe the instrumental set-up, capabilities, and applicability of µXRF analysis to astromaterials curation and re-search. Instrumentation and Methodology: The X-ray fluorescence and computed tomography lab (X-FaCT) lab at JSC is now equipped with a Bruker M4 Tornado Plus µXRF (Fig. 1). This system is an energy-dispersive x-ray spectrometer equipped with two 60 mm2 silicon drift detectors (SDD) that are able to be used simulta-neously for output count rates ~500,000 cps. New light element windows allow detecting and analyzing the entire elemental range from carbon to americium. Two x-ray tubes (micro-focus Rh with polycapillary lenses and W with collimators of 0.5, 1.0, 2.0, and 4.5 mm) with max excitation parameters of 50 kV, 30 W and 50 kV, 40 W, respectively, allow for more flexibility of the analysis of high energy lines. The motorized X-Y-Z stage has a mapping range of 190 x 160 mm and can support samples up to 7 kg (~15.5 lbs) and a height of 120 mm [4]. Analytical modes include elemental analysis (down to ~20 µm spot size) via point, line, or area of bulk materials (rock surfaces, thin sections, thick sections, etc.) as well as coating analysis (determination of thickness and composition) of samples. This system has a variable vacuum chamber (1 mbar to 1 atm) that is also equipped with a He-purge system which accommodates vacuum sensitive samples while still allowing detection of light elements at atmospheric pressure. Utility and Applicability of µXRF in Astro-materials research and exploration science (ARES): Elemental analysis using µXRF is commonly em-ployed for both terrestrial and planetary geological science disciplines [5]. It is especially useful for analy-sis of astromaterials given the limited sample prepara-tion required, which is not feasible for certain materi-als. Here we show select applications of µXRF anal-yses of astromaterials that can, have, and will be done at JSC’s X-FaCT lab. Point analysis: In-situ spot analyses (~20 µm spot size) on a cut slab of Martian meteorite NWA 10922 allowed for the discovery, qualitative elemental analy-sis and determination of different feldspar minerals [6]. These point analyses served as an effective prelim-inary step for subsequent quantitative analyses. Ana-lytical standards can be employed for more accurate quantification of µXRF spot analyses. Area analysis: This analytical mode measures all detectable elements (from C to Am) at each pixel (>5 µm pixel size) in a user-defined area. The results are shown as elemental maps which can be extracted as 16-bit TIFF’s for further data processing. In Fig. 2. we show elemental distribution maps of the high-Ti basalt 73001,531 that have been processed using ImageJ software. From these maps you can accurately and quickly (this map took ~50 mins.) identify mineral components, such as pyroxene, plagioclase, oxides, and phosphates, compositional zoning, and mineral textures. Detection of high-Z phases: µXRF techniques are es-pecially effective at analyzing trace minerals with high-atomic-number (high-Z) elements because the high-energy characteristic X-rays used (relative to SEM EDS) allow for mapping of K lines in elements up to La (typically SEM maps use L X-ray lines for elements >Zn, and these can often have interferences). Thus, µXRF is especially suited for identifying minerals like zircon, baddeleyite, REE-rich phosphates, Fe-rich met-als, oxides, sulfides, and phosphides [4]. In Fig. 3 we show elemental distribution maps for 73001,530 where we are able to correlate the original video image with, Zr, Si, Y and Hf elemental maps together identi-fying the location of a zircon. In this location you would expect lower Si compared to surrounding mate-rial, as well as higher Zr, Y, and Hf content compared to surrounding material, all of which is confirmed by our XRF ele-mental distribution maps (Figure 2.) Conclusions: The new M4 Tornado Plus µXRF within the Astromaterials Acquisition and Curation office at NASA JSC allows for rapid and non-destructive elemental analysis of astromaterials with limited or no sample preparation. µXRF analyses pro-vide crucial compositional knowledge for the prelimi-nary examination and curation of astromaterials. This instrument enhances the advanced curation capabili-ties in the X-FaCT laboratory at JSC by allowing pro-ductive, cohesive, and non-destructive multi-modal x-ray analyses on astromaterial samples, which is neces-sary for the comprehensive curation and study of our current and future astromaterial collections. Addition-ally, µXRF can provide complimentary information to researchers for studies on astromaterials. References: [1] Allen, C. et al., (2011). Chemie De Erde Geochemistry, 71, 1-20. [2] McCubbin, F. M. et al., (2016) 47th LPSC, abstract #2668 [3] Zeigler, R. A. et al., (2017) 48th LPSC, abstract #2772 [4] Bruker User Manual [5] Young et al., (2016) Appl. Geochemistry, 72, 77-87 [6] Mor-ris, R. V. et al., (2023) 54th LPSC.

E W O'Neal↗

TEM Study of SAFARI-2000 Aerosols

The aim of our research was to obtain data on the chemical and physical properties of individual aerosol particles from biomass smoke plume s in southern Africa and from air masses in the region that are affec ted by the smoke. We used analytical transmission electron microscopy (ATEM), including energy-dispersive X-ray spectrometry (EDS) and ele ctron energy-loss spectroscopy (EELS), and field-emission electron microscopy (FESEM) to study aerosol particles from several smoke and haz e samples and from a set of cloud samples.

Buseck, Peter R.↗

Characterization of Individual Aerosol Particles Associated with Clouds (CRYSTAL-FACE)

The aim of our research was to obtain data on the chemical and physical properties of individual aerosol particles from near the bottoms and tops of the deep convective systems that lead to the generation of tropical cirrus clouds and to provide insights into the particles that serve as CCN or IN. We used analytical transmission electron microscopy (ATEM), including energy-dispersive X-ray spectrometry (EDS) and electron energy-loss spectroscopy (EELS), and field-emission electron microscopy (FESEM) to compare the compositions, concentrations, size distributions, shapes, surface coatings, and degrees of aggregation of individual particles from cloud bases and the anvils near the tropopause. Aggregates of sea salt and mineral dust, ammonium sulfate, and soot particles are abundant in in-cloud samples. Cirrus samples contain many H2SO4 droplets, but acidic sulfate particles are rare at the cloud bases. H2SO4 probably formed at higher altitudes through oxidation of SO2 in cloud droplets. The relatively high extent of ammoniation in the upper troposphere in-cloud samples appears to have resulted from vertical transport by strong convection. The morphology of H2SO4 droplets indicates that they had been at least yartiy ammoniated at the time of collection. They are internally mixed with organic materials, metal sulfates, and solid particles of various compositions. Ammoniation and internal mixing of result in freezing at higher temperature than in pure H2SO4 aerosols. K- and S-bearing organic particles and Si-Al-rich particles are common throughout. Sea salt and mineral dust were incorporated into the convective systems from the cloud bases and worked as ice nuclei while being vertically transported. The nonsulfate particles originated from the lower troposphere and were transported to the upper troposphere and lower stratosphere.

Buseck, Peter R.↗

High-Resolution Electron Energy-Loss Spectroscopy (HREELS) Using a Monochromated TEM/STEM

A 200 keV FEI TF20 XT monochromated (scanning) transmission electron microscope funded by NASA's SRLIDAP program is undergoing installation at Lawrence Livermore National Laboratory. Instrument specifications in STEM mode are Cs =1.0 mm, Cc =1.2 mm, image resolution =0.18 nm, and in TEM mode Cs =1.3 mm, Cc =1.3 mm, information limit =0.14 nm. Key features of the instrument are a voltage-stabilized high tension (HT) supply, a monochromator, a high-resolution electron energy-loss spectrometer/energy filter, a high-resolution annular darkfield detector, and a solid-state x-ray energy-dispersive spectrometer. The high-tension tank contains additional sections for 60Hz and high frequency filtering, resulting in an operating voltage of 200 kV plus or minus 0.005V, a greater than 10-fold improvement over earlier systems. The monochromator is a single Wien filter design. The energy filter is a Gatan model 866 Tridiem-ERS high resolution GIF spec d for less than or equal to 0.15 eV energy resolution with 29 pA of current in a 2 nm diameter probe. 0.13 eV has already been achieved during early installation. The x-ray detector (EDAX/Genesis 4000) has a take-off angle of 20 degrees, an active area of 30 square millimeters, and a solid angle of 0.3 steradians. The higher solid angle is possible because the objective pole-piece allows the detector to be positioned as close as 9.47 mm from the specimen. The voltage-stabilized HT supply, monochromator and GIF enable high-resolution electron energy-loss spectroscopy (HREELS) with energy resolution comparable to synchrotron XANES, but with approximately 100X better spatial resolution. The region between 0 and 100 eV is called the low-loss or valence electron energy-loss spectroscopy (VEELS) region where features due to collective plasma oscillations and single electron transitions of valence electrons are observed. Most of the low-loss VEELS features we are detecting are being observed for the first time in IDPs. A major focus of our research is to understand the origin and significance of these features and how they might be exploited to gain insight about IDPs and other meteoritic materials.

Sai, Z. R.↗

Water-Rock Interactions in Outer Solar System Bodies: Evidence from the Coordinated Analysis of Interplanetary Dust

NASA has an ongoing program of collecting interplanetary dust particles (IDPs) in the stratosphere using high altitude research aircraft. The collected IDPs are derived from asteroids and comets and here we report studies of a subset of hydrated IDPs rich in carbonaceous matter that are proposed to have a cometary origin. Our studies are aimed at understanding the evolution of oxygen reservoirs in the Solar System and their interaction with cometary minerals and organic matter. The small size (<20 μm) and fragility of these IDPs present a number of analytical challenges. We have pioneered techniques for performing chemical, mineralogical, isotopic, and spectroscopic measurements on the same sample in a carefully coordinated sequence. Coordinated analyses of nanogram-size samples is made possible by several delicate sample preparation techniques. To avoid organic contamination, we embed IDPs in elemental sulfur and use ultramicrotomy to partly section the particles (the first few micrometers). Multiple thin sections (50-70 nm thick) are placed on different substrates depending on the analysis technique. We use a JEOL 2500SE scanning, transmission electron microscope (STEM) to determine the mineralogy, microstructure, and elemental compositions of constituent minerals in the thin sections through a combination of high resolution imaging, electron diffraction, quantitative energy-dispersive x-ray mapping, and electron energy-loss spectroscopy. Following the STEM analyses, we use a NanoSIMS 50L for high spatial resolution isotopic measurements of H, C, N, and O to search for presolar grains and to understand the origin of the indigenous organic matter. The isotopic analyses are performed on the same sections analyzed in the STEM in order to correlate isotopic properties with the elemental and mineralogical data. We reserve other thin sections for non-destructive analyses utilizing synchrotron-based techniques including Fourier-transform infrared (FTIR) micro-spectroscopy and X-ray absorption near-edge structure (XANES) analyses, especially for functional group analysis of organic matter in the particles. The remainder of the IDP is extracted from the sulfur bead that was used for microtomy and is pressed into Au foil for quantitative analysis (including light elements) using a JEOL 8530F field emission electron probe microanalyzer (EPMA). After the EPMA measurements, high precision oxygen isotopic analyses are obtained using Cameca IMS1270/1290 instruments at UCLA. The hydrated IDPs in this study are dominated by saponitic clays, with minor magnetite, carbonate and abundant organic matter. The remarkable oxygen isotopic compositions, high carbon contents, and the abundance of isotopically anomalous organic matter, together suggest that the high carbon, hydrated IDPs are derived from primitive sources not yet represented in meteorite collections such as outer main belt P- and D-type asteroids or comets.

Keller, Lindsay P.↗