Search NASA⌕ Search

SEARCH · Search NASA

Results for “Enhanced condensation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Outgassing of casted and 3D printed silicones

Outgassing of 3D printed and casted silica-filled silicones was studied using a standard ASTM E-595 procedure and a modified Soreq’s method that allows very sensitive measurements of the outgassing kinetics even at low temperatures, 20 – 50 °C. We studied three different silica-filled silicones, non-porous cased M9787, and 3D printed LL50 and 40P materials. The present report shows that vacuum outgassing products of polysiloxane-based materials include multiple species. In addition to chemisorbed and physisorbed water outgassing, previously studied by TPD, polymer fragments of varying sizes evaporate as well. The chemical composition of the condensable volatile species collected on a Germanium substrate, was analyzed by FTIR. It was shown that all studied materials produce mostly PDMS-based outgassing products that form stable droplet-like structure on the Ge substrate. The highest amount of the condensable volatile species was measured for LL50. Isothermal TGA in nitrogen atmosphere of the LL50 material was compared to the standard vacuum outgassing. The results of TGA showed lower mass loss and higher water regain. The kinetics of the outgassing at relatively low temperatures of 20, 30 and 50 °C was studied using Thermoelectric Quartz Crystal Microbalance (TQCM). The TQCM surface was held at -10 °C to enhance condensation of the outgassed moisture. The analysis presented here, when combined with the extensive previous work on moisture outgassing, provides a better understanding of the aging mechanism of polysiloxane-based materials. In this work we show that outgassing techniques, usually applied for qualification of polymers for space-related applications, may be used as a complementary method to study thermal degradation and aging of silica-based silicones. Our results indicate that the long-term degradation mechanics and thermal degradation products depend primarily on the chemical composition of silicone-based material and only slightly affected by the manufacturing process. Surprisingly, the surface-to-volume ratio of the 3D printed vs. casted/molded materials showed only minor effect on the outgassing kinetic parameters.

36 MATERIALS SCIENCE↗

Silicon alloying enhances fast heating rate combustion of aluminum particles

Alloys and composites of aluminum (Al) have shown promise in regulating and enhancing particle combustion for energy generation applications. Recent work on aluminum-silicon (Al-Si) spherical alloy particles has shown improved combustion at low heating rates through enhanced diffusion accompanying a lower melting temperature. This study extends reactivity analysis to higher heating rates, comparing oxidation of Al-Si with Al. Flame speeds of Al-Si powder mixed with molybdenum trioxide (MoO 3 ) powder (Al-Si+MoO 3 ) exhibited a faster transition to steady propagation relative to Al+MoO 3 . Bomb calorimetry experiments revealed up to 5.8% greater early temperature rise for Al-Si powder. Rapid steady propagation for Al-Si mixture and faster temperature rise for Al-Si particles were attributed to accelerated kinetics evidenced in thermal equilibrium analysis of the mixtures using a differential scanning calorimeter (DSC). Larger DSC exotherms in the early stages of oxidation (i.e., 480–720 °C) correlated with early heat release and promoted steady flame propagation for Al-Si+MoO 3 compared with Al+MoO 3 . Furthermore, in multiple heating rate DSC studies, Al-Si+MoO 3 ignited at a lower heating rate (i.e., 15 ⁰C/min) than Al+MoO 3 (i.e., 20 ⁰C/min). Both mixtures ignited at temperatures less than 625 °C which is above the melting temperature of Al-Si (574 °C) and below Al (659 °C). Thus, alloy particle fuels with enhanced diffusion-controlled kinetics promote steady flame propagation and show promise for energy generation applications. This is especially promising for technologies driven by enhanced condensed phase combustion such as some propellant additives or applications dependent on reliable burn rates such as pyrotechnic time delay formulations and primers.

36 MATERIALS SCIENCE↗

NUMERICAL INVESTIGATION OF AIR DEHUMIDIFICATION THROUGH WATER DROPLETS DIELECTROPHORESIS

This paper numerically investigated the dehumidification of moist airflow in a converging rectangular duct with electrically enhanced condensation. The aim was to develop a condensation model that predicted water vapor condensation by employing the dielectrophoresis principle. The charged droplets were injected into the computational domain to produce a gradient electric field. The dielectrophoretic interaction between the droplets and vapor molecules of the humid air resulted in local water vapor condensation at the vapor and liquid droplet interface. This phenomenon is described in detail in this paper. A hybrid Eulerian-Lagrangian solver SprayFoam was developed based on OpenFOAM® to simulate condensation in two-phase gas-liquid mixtures. The following developments were made based on the standard compressible multiphase flow solver SprayFoam in OpenFOAM®: (1) Eulerian solver for gas phase (2) multi-component species transport, and (3) Lagrangian solver for gas-droplet two-phase flows and sub-models for liquid droplets. The newly developed numerical model was experimentally validated with data from a series of tests conducted in the authors' laboratory. The results showed that the simulations followed the same trends as the data, and the model predicted the condensation due to the electro-spray injection process in the air stream. The injected water droplets, which are electrically charged to their Rayleigh limits, increased in size while wiping out the humidity from the air. The simulations indicated that the dehumidification was about 1% for 0.5 cubic feet per minute airflow rate. Scaling up to larger flows is a future follow-up work.

Yel Mahi, *Maliha↗

Examining the vertical heterogeneity of aerosols over the Southern Great Plains

Abstract. Atmospheric aerosols affect the global energy budget by scattering and absorbing sunlight (direct effects) and by changing the microphysical structure, lifetime, and coverage of clouds (indirect effects). Both aerosol direct and indirect effects are affected by the vertical distribution of aerosols in the atmosphere, which is further influenced by a range of processes, such as aerosol dynamics, long-range transport, and entrainment. However, many observations of these processes are based on ground measurements, limiting our ability to understand the vertical distribution of aerosols and simulate their impact on clouds and climate. In this work, we examined the vertical heterogeneity of aerosols over the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) using data collected from the Holistic Interactions of Shallow Clouds, Aerosols and Land Ecosystems (HI-SCALE) campaign. The vertical profiles of meteorological and aerosol physiochemical properties up to 2500 m above are examined based on the 38 flights conducted during the HI-SCALE campaign. The aerosol properties over the SGP show strong vertical heterogeneity and seasonal variabilities. The aerosol concentrations at the surface are the highest due to strong emissions at ground level. In general, the mode diameter of aerosols during summer (∼ 100 nm) is larger than that during spring (∼ 30 nm), a result of enhanced condensational growth due to enriched volatile organic compounds in summer. The concentration of aerosols below 30 nm in the boundary layer (BL) (e.g., below 1000 m) during spring is higher than that during summer, a result of the stronger new particle formation (NPF) events due to the reduced condensation sink in spring. In the BL, the size of the aerosols gradually increases with altitude due to condensational growth and cloud processing. However, the chemical composition of the aerosols remained similar, with organics and sulfates representing 59.8 ± 2.2 % and 22.7 ± 2.1 %, respectively, of the total mass in the BL. Through the vertical profiles of aerosol properties, we observed NPF events in the upper BL during 7 out of 38 research flights, where the newly formed particles continue to grow as they are mixed down to the surface. There is also an indication that deep convection brings aerosols from the free troposphere (FT) to the surface, where they grow to contribute to the cloud condensation nuclei (CCN). Overall, the vertical heterogeneity of aerosols over the SGP is influenced by aerosol dynamics (new particle formation, growth, and cloud processing) and transport processes (mixing in the BL, long-range transport, entrainment, and convective downward transport). Case studies showing the influence of these factors are discussed.

54 ENVIRONMENTAL SCIENCES↗

Capillary-driven Condensation for Heat Transfer Enhancement in Steam Power Plants

A novel condensation method was developed to enhance the efficiency of steam power plants. The method consists of a hierarchical structure on the surface of condenser tubes consisting of a wicking structure overlaid with a porous hydrophobic membrane. The project is divided into two main efforts. First, a structure with highly defined geometry was made utilizing microfabrication on silicon. This structure helped us elucidate the physics of steam condensation at the surface, more easily model the heat transfer coefficient, and demonstrate the first proof-of-concept for our proposed condensation approach. The structures on silicon achieved a heat transfer coefficient ~ 240% higher than the theoretical filmwise value at the same operating condition. Second, the method is explored for scalability by fabricating surfaces with industrial class materials followed by heat transfer measurements on flat surfaces. An HTC enhancement of 50% over the experimental filmwise value was achieved on hierarchical copper surfaces made of commercially available copper foams and meshes, showing the potential of achieving heat transfer enhancement using low cost and scalable materials. Scalable fabrication of the hydrophobic membrane and the porous copper wick were also investigated. Our heat and mass transfer model predicts a > 5x heat transfer enhancement on a scalable version of capillary driven condenser made of membrane covered porous copper. The results demonstrate the promise of capillary-driven condensation surfaces for heat transfer applications.

20 FOSSIL-FUELED POWER PLANTS↗

Novel solid-infused durable nonwetting surfaces for sustained condensation heat transfer enhancement

Here, in this article, we report novel nonwetting solid-infused surfaces that are easily fabricated using industrially widely adopted methods such as chemical etching or electrodeposition and exhibit sustained dropwise condensation performance durably than superhydrophobic and lubricant-infused surfaces. Solid-infused surfaces demonstrate fourfold larger condensation heat transfer coefficient and 25% better condensation effectiveness when compared to superhydrophobic surface and conventional filmwise condensation. Although the condensation heat transfer coefficient of lubricant-infused surface initially matches that of solid-infused surface, it is shown through durability studies that the wettability characteristic that underpins the performance of lubricant-infused surfaces degrades quickly with time as the lubricant depletes and lubricant-infused surface transitions to superhydrophobic surface. Solid-infused surface, on the other hand, retains its steadfast superior dropwise condensation effectiveness in the long run, overcoming the challenges of droplet pinning, surface inundation, cloaking, and lubricant depletion that eventually deteriorate condensation on conventional nonwetting superhydrophobic and lubricant-infused surfaces.

42 ENGINEERING↗

Enhancements in Cloud Condensation Nuclei Activity From Turbulent Fluctuations in Supersaturation

Abstract The effect of aerosols on the properties of clouds is a large source of uncertainty in predictions of weather and climate. These aerosol‐cloud interactions depend critically on the ability of aerosol particles to form cloud droplets. A challenge in modeling aerosol‐cloud interactions is the representation of interactions between turbulence and cloud microphysics. Turbulent mixing leads to small‐scale fluctuations in water vapor and temperature that are unresolved in large‐scale atmospheric models. To quantify the impact of turbulent fluctuations on cloud condensation nuclei (CCN) activation, we used a high‐resolution Large Eddy Simulation of a convective cloud chamber to drive particle‐based cloud microphysics simulations. We show small‐scale fluctuations strongly impact CCN activity. Once activated, the relatively long timescales of evaporation compared to fluctuations causes droplets to persist in subsaturated regions, which further increases droplet concentrations.

54 ENVIRONMENTAL SCIENCES↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗

Analysis of Electro-static Assisted Air Dehumidification

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 μm in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

Analysis of New Data of Electro-static Assisted Air Dehumidification Processes

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 m in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

Pyrolysis Vapor and Bio-Oil Preconditioning via Ex Situ Hydrodeoxygenation and Alkylation Using a Heteropolyacid Catalyst

Ex situ catalytic preconditioning of biomass pyrolysis vapors (partial deoxygenation) has the potential for both reducing the oxygen content and beneficially influencing the oxygen speciation of condense bio-oils for enhancement of downstream condensed phase upgrading processes. Here, condensed phase upgrading processes may refer to both coprocessing and hydroprocessing with vacuum gas-oil (VGO). Reduction of oxygen content to produce bio-oils with greater hydrophobicity can enhance VGO-solubility while tailoring of oxygen speciation by removal of reactive carbonyls (e.g., acetic acid) can lessen catalytic deactivation via coking reactions. 1,2 Furthermore, enhanced VGO-solubility and reduced coking leads to greater biogenic carbon incorporation in end-products from condensed phase upgrading processes. By leveraging the hydrodeoxygenation and alkylation activity of a titania-supported molybdenum-heteropolyacid (Mo-HPA/TiO2) catalyst, pyrolysis vapors and resulting condensed bio-oils were effectively preconditioned for downstream upgrading. 3 Data regarding the use of Mo-HPA/TiO2 for pyrolysis vapor preconditioning will be presented on, including method of employment, catalyst characterization, and impacts on bio-oil in relation to downstream condensed phase upgrading processes. Our approach is to: Compare Mo-HPA/TiO2 product distribution to HZSM-5; Investigate Mo-HPA/TiO2 regeneration and characterize changes in acid site character; Assess product differences in terms of enhanced VGO-solubility.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technoeconomic assessment of distillation heat transfer intensification using aeroelastically fluttering reeds

Dry cooling, where forced air is the heat transfer medium, is a preferable cooling method in arid locations lacking readily available process water. However, such locations often experience high ambient temperatures that limit the effectiveness of air cooling. The objective of this study is to quantify the economic and energetic benefits of heat transfer intensification via the implementation of aeroelastically fluttering reeds to the air-cooled condenser of a methanol distillation column. Condenser size and performance, regarding recovered methanol and required fan power, is evaluated across condenser operating temperatures (T cond ) from 60 to 62°C and heat transfer coefficients (U) U base –2U base for a range of inlet air temperatures based on ambient temperature data from Yuma, Arizona. Under typical design sizing, condenser capital cost was reduced by 6%–35% (1.3U base –2U base ) and nominal methanol recovery was increased from 0.26% to 0.38% (T cond = 62–60°C). At optimized condenser size, all enhanced U and T cond pairs increase methanol recovery and reduce fan power costs compared to the optimal Ubase reference. Overall, using enhanced heat transfer to maintain condenser temperature under a wider range of inlet conditions, rather than to reduce operation temperature, produces more favorable performance. Methanol price is not a determining factor in which pairs are profitable. Analysis was repeated for a global warming scenario, revealing more valuable improvements under elevated temperatures. Energy savings from condenser improvement to a methanol production system are not significant with respect to an optimized conventional system. Furthermore, unit economic and energetic incentives suggest implementation of fluttering reeds may be justified in other applications.

42 ENGINEERING↗

Arctic warming by abundant fine sea salt aerosols from blowing snow

Abstract The Arctic warms nearly four times faster than the global average, and aerosols play an increasingly important role in Arctic climate change. In the Arctic, sea salt is a major aerosol component in terms of mass concentration during winter and spring. However, the mechanisms of sea salt aerosol production remain unclear. Sea salt aerosols are typically thought to be relatively large in size but low in number concentration, implying that their influence on cloud condensation nuclei population and cloud properties is generally minor. Here we present observational evidence of abundant sea salt aerosol production from blowing snow in the central Arctic. Blowing snow was observed more than 20% of the time from November to April. The sublimation of blowing snow generates high concentrations of fine-mode sea salt aerosol (diameter below 300 nm), enhancing cloud condensation nuclei concentrations up to tenfold above background levels. Using a global chemical transport model, we estimate that from November to April north of 70° N, sea salt aerosol produced from blowing snow accounts for about 27.6% of the total particle number, and the sea salt aerosol increases the longwave emissivity of clouds, leading to a calculated surface warming of +2.30 W m −2 under cloudy sky conditions.

54 ENVIRONMENTAL SCIENCES↗

RF current condensation in the presence of turbulent enhanced transport

Sharp temperature gradients in a magnetically confined plasma can lead to turbulent motion of the plasma. This turbulence in turn enhances the transport of heat across magnetic field lines. The enhanced transport impacts the temperature differential that can be sustained in magnetic islands between the island center and its periphery. It is shown in this work that, by limiting this temperature differential, this enhanced transport can have a profound influence on the extent to which the RF current condensation effect stabilizes the island growth. Interestingly, because the heat transport is no longer simply linear in the temperature gradient, the RF current condensation effect also exhibits entirely new hysteresis phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Novel Steam Condenser with Loop Thermosyphons and Film-Forming Agents for Improved Heat Transfer Efficiency and Durability

In this DOE/NETL BAA program, Advanced Cooling Technologies, Inc. (ACT), with Suez Water Technologies & Solutions (Suez), developed film-forming amine coatings applied to condenser surfaces that incorporated loop thermosyphons to enhance steam surface condenser performance and efficiency for coal-fired power plants. The condensation phenomenon resulting from these coatings promotes efficient dropwise condensation without additional thermal resistance through the use of film-forming amines (FFA). The loop thermosyphon technology was being developed to supplant current pumped cooling water systems to reduce operations and maintenance issues, reduce energy use, and promote high thermal performance. Both of ACT’s advanced coating and loop thermosyphon technologies were developed for application to wet cooling and indirect dry cooling systems. Internal steam condensation and subsequent heat dissipation complete the thermodynamic power cycle used by power plant cooling systems. The successful 3-year project period delved into understanding the experimental performance gain using film-forming amines applied to flat and tubular condenser surfaces under realistic operating conditions. The performance gain was used to create a technoeconomic analysis to more clearly understand the market value for power plants using FFA coatings to achieve dropwise condensation on condenser surfaces. A tall (50 ft.) loop thermosyphon was designed, fabricated, and tested to optimize the performance characteristics by tuning the working fluid charge and determining the temperature drop across the loop at different heat loads. Commercialization opportunities were explored to transition the loop thermosyphon work into the building HVAC market.

20 FOSSIL-FUELED POWER PLANTS↗

Enhancement of ECCD by the current condensation effect for stabilizing large magnetic islands caused by neoclassical tearing modes in tokamak plasmas

The radio frequency current condensation effect reported in Reiman and Fisch (2018 Phys. Rev. Lett. 121 225001) is modeled in the nonlinear resistive magnetohydrodynamic code. A series of numerical investigations have been performed to investigate the enhancement of electron cyclotron current drive (ECCD) by the current condensation effect during the control of neoclassical tearing mode (NTM) in tokamak plasmas. In the numerical model, both the parallel transport and the perpendicular transport of electron temperature are considered. The EC driven current and driven perturbed electron temperature can nonlinearly evolve within the given magnetic configuration and eventually reach saturation states. The input power threshold of ECCD and the fold bifurcation phenomenon are numerically verified via nonlinear simulations. The numerical results show good agreements with the analytical results. Moreover, spatial distributions of EC current for the two solutions at different condensed level are displayed. The control effectiveness of ECCD for large NTM islands has been evaluated while considering the current condensation effect. While taking into account current condensation effect, for a sufficiently large input power, a larger island can be more effectively stabilized than a smaller one, which suggests a reassessment of the previous idea that the ECCD should always be turned on as early as possible. The potential physics mechanism behind the ECCD control have all been discussed in detail. Furthermore, the condensation effect is found to have favorable effects on the radial misalignment of ECCD. In the consideration of the situation for extremely localized control needs, a highly peaked heating profile is adopted to verify that the fold bifurcation phenomenon still exists and the current condensation effect can still take effect in this extreme condition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗