Search NASA⌕ Search

SEARCH · Search NASA

Results for “Error Floors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

MO-D-213-07: RadShield: Semi- Automated Calculation of Air Kerma Rate and Barrier Thickness

Purpose: To develop the first Java-based semi-automated calculation program intended to aid professional radiation shielding design. Air-kerma rate and barrier thickness calculations are performed by implementing NCRP Report 147 formalism into a Graphical User Interface (GUI). The ultimate aim of this newly created software package is to reduce errors and improve radiographic and fluoroscopic room designs over manual approaches. Methods: Floor plans are first imported as images into the RadShield software program. These plans serve as templates for drawing barriers, occupied regions and x-ray tube locations. We have implemented sub-GUIs that allow the specification in regions and equipment for occupancy factors, design goals, number of patients, primary beam directions, source-to-patient distances and workload distributions. Once the user enters the above parameters, the program automatically calculates air-kerma rate at sampled points beyond all barriers. For each sample point, a corresponding minimum barrier thickness is calculated to meet the design goal. RadShield allows control over preshielding, sample point location and material types. Results: A functional GUI package was developed and tested. Examination of sample walls and source distributions yields a maximum percent difference of less than 0.1% between hand-calculated air-kerma rates and RadShield. Conclusion: The initial results demonstrated that RadShield calculates air-kerma rates and required barrier thicknesses with reliable accuracy and can be used to make radiation shielding design more efficient and accurate. This newly developed approach differs from conventional calculation methods in that it finds air-kerma rates and thickness requirements for many points outside the barriers, stores the information and selects the largest value needed to comply with NCRP Report 147 design goals. Floor plans, parameters, designs and reports can be saved and accessed later for modification and recalculation. We have confirmed that this software accurately calculates air-kerma rates and required barrier thicknesses for diagnostic radiography and fluoroscopic rooms.

07 ISOTOPE AND RADIATION SOURCES↗

Multiple Explanations for the Single Transit of KIC 5951458 Based on Radial Velocity Measurements Extracted with a Novel Matched-template Technique

Planetary systems that show single-transit events are a critical pathway to increasing the yield of long-period exoplanets from transit surveys. From the primary Kepler mission, KIC 5951458 b (Kepler-456b) was thought to be a single-transit giant planet with an orbital period of 1310 days. However, radial velocity (RV) observations of KIC 5951458 from the HIRES instrument on the Keck telescope suggest that the system is far more complicated. To extract precise RVs for this V≈13 star, we develop a novel matched-template technique that takes advantage of a broad library of template spectra acquired with HIRES. We validate this technique and measure its noise floor to be 4–8 m s{sup −1} (in addition to internal RV error) for most stars that would be targeted for precision RVs. For KIC 5951458, we detect a long-term RV trend that suggests the existence of a stellar companion with an orbital period greater than a few thousand days. We also detect an additional signal in the RVs that is possibly caused by a planetary or brown dwarf companion with mass in the range of 0.6–82 M {sub Jup} and orbital period below a few thousand days. Curiously, from just the data on hand, it is not possible to determine which object caused the single “transit” event. We demonstrate how a modest set of RVs allows us to update the properties of this unusual system and predict the optimal timing for future observations.

79 ASTRONOMY AND ASTROPHYSICS↗

3D Measurement Simulation and Relative Pointing Error Verification of the Telescope Mount Assembly Subsystem for the Large Synoptic Survey Telescope

An engineering validation of a large optical telescope consists of executing major performing tests at the subsystem level to verify the overall engineering performance of the observatory. Thus, the relative pointing error verification of the telescope mount assembly subsystem is of special interest to guarantee the absolute pointing performance of the large synoptic survey telescope. This paper presents a new verification method for the relative pointing error assessment of the telescope mount assembly, based on laser tracker technology and several fiducial points fixed to the floor. Monte-Carlo-based simulation results show that the presented methodology is fit for purpose, even if floor movement occurs due to temperature variation during the measurement acquisition process. A further research about laser tracker technology integration into the telescope structure may suggest that such laser tracker technology could be permanently installed in the telescope in order to provide an active alignment system that aims to detect and correct possible misalignment between mirrors or to provide the required mirror positioning verification accuracy after maintenance activities. The obtained results show that two on-board laser tracker systems combined with eight measurement targets could result in measurement uncertainties that are better than 1 arcsec, which would provide a reliable built-in metrology tool for large telescopes.

47 OTHER INSTRUMENTATION↗

Testing of a 3-D Sonar for Future Deployment to Image Solids on the Floor of Hanford, HLW Conditioning Tanks - 15646

Florida International University (FIU) has tested the capability of 2-D and 3-D sonar systems to image solids settled on the floor of tanks, on the bottom of streams and small rivers, and in 55 gallon drums. FIU developed and successfully tested the Solid-Liquid Interface Monitor (SLIM) for mapping the interface between supernatant and settled solids in several test tanks. SLIM is comprised of: a sonar, a mechanical system for deploying the system into large high-level radioactive waste (HLW) tanks, and imaging programs and algorithms developed at and by FIU faculty and staff. Early testing had the objective to demonstrate the ability of SLIM to image and quantify the height and volume of settled solids on the floor of 1-million-gallon, HLW tanks at Hanford. Testing showed that SLIM: (1) functions accurately in liquid radioactive HLW tank conditions [i.e., caustic (pH>14), warm (up to 45 degrees Centigrade), and highly radioactive]; (2) provides accurate imaging of solids surfaces (1-2% relative error in the height of interfaces); and (3) provides an excellent volume estimation of the solids, thereby allowing engineers to fill tanks closer to the maximum allowed level and optimize solids retrieval; and (4) enables better placement of pumps inside tanks during retrieval to minimize the potential for plugging. The New Hanford technology need is for rapid imaging (even during vigorous mixing) of solids on the floor of conditioning (mixing) tanks. Results of recent successful testing show imaging times under 1 minute, solids volume estimates with <5% error and effective filtering and visualization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CMM Interim Check (U)

Coordinate Measuring Machines (CMM) are widely used in industry, throughout the Nuclear Weapons Complex and at Los Alamos National Laboratory (LANL) to verify part conformance to design definition. Calibration cycles for CMMs at LANL are predominantly one year in length. Unfortunately, several nonconformance reports have been generated to document the discovery of a certified machine found out of tolerance during a calibration closeout. In an effort to reduce risk to product quality two solutions were proposed – shorten the calibration cycle which could be costly, or perform an interim check to monitor the machine’s performance between cycles. The CMM interim check discussed makes use of Renishaw’s Machine Checking Gauge. This off-the-shelf product simulates a large sphere within a CMM’s measurement volume and allows for error estimation. Data was gathered, analyzed, and simulated from seven machines in seventeen different configurations to create statistical process control run charts for on-the-floor monitoring.

42 ENGINEERING↗

A BASIS FOR MODIFYING THE TANK 12 COMPOSITE SAMPLING DESIGN

The SRR sampling campaign to obtain residual solids material from the Savannah River Site (SRS) Tank Farm Tank 12 primary vessel resulted in obtaining appreciable material in all 6 planned source samples from the mound strata but only in 5 of the 6 planned source samples from the floor stratum. Consequently, the design of the compositing scheme presented in the Tank 12 Sampling and Analysis Plan, Pavletich (2014a), must be revised. Analytical Development of SRNL statistically evaluated the sampling uncertainty associated with using various compositing arrays and splitting one or more samples for compositing. The variance of the simple mean of composite sample concentrations is a reasonable standard to investigate the impact of the following sampling options. Composite Sample Design Option (a). Assign only 1 source sample from the floor stratum and 1 source sample from each of the mound strata to each of the composite samples. Each source sample contributes material to only 1 composite sample. Two source samples from the floor stratum would not be used. Composite Sample Design Option (b). Assign 2 source samples from the floor stratum and 1 source sample from each of the mound strata to each composite sample. This infers that one source sample from the floor must be used twice, with 2 composite samples sharing material from this particular source sample. All five source samples from the floor would be used. Composite Sample Design Option (c). Assign 3 source samples from the floor stratum and 1 source sample from each of the mound strata to each composite sample. This infers that several of the source samples from the floor stratum must be assigned to more than one composite sample. All 5 source samples from the floor would be used. Using fewer than 12 source samples will increase the sampling variability over that of the Basic Composite Sample Design, Pavletich (2013). Considering the impact to the variance of the simple mean of the composite sample concentrations, the recommendation is to construct each sample composite using four or five source samples. Although the variance using 5 source samples per composite sample (Composite Sample Design Option (c)) was slightly less than the variance using 4 source samples per composite sample (Composite Sample Design Option (b)), there is no practical difference between those variances. This does not consider that the measurement error variance, which is the same for all composite sample design options considered in this report, will further dilute any differences. Composite Sample Design Option (a) had the largest variance for the mean concentration in the three composite samples and should be avoided. These results are consistent with Pavletich (2014b) which utilizes a low elevation and a high elevation mound source sample and two floor source samples for each composite sample. Utilizing the four source samples per composite design, Pavletich (2014b) utilizes aliquots of Floor Sample 4 for two composite samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford double-shell tank extent-of-condition construction review - 15498

During routine visual inspections of Hanford double-shell waste tank 241-AY-102 (AY-102), anomalies were identified on the annulus floor which resulted in further evaluations. Following a formal leak assessment in October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of AY-102 was leaking. A formal leak assessment, documented in RPP-ASMT-53793, Tank 241-AY-102 Leak Assessment Report, identified first-of-a-kind construction difficulties and trial-and-error repairs as major contributing factors to tank failure. To determine if improvements in double-shell tank (DST) construction occurred after construction of tank AY-102, a detailed review and evaluation of historical construction records was performed for Hanford's remaining twenty-seven DSTs. Review involved research of 241 boxes of historical project documentation to better understand the condition of the Hanford DST farms, noting similarities in construction difficulties/issues to tank AY-102. Information gathered provides valuable insight regarding construction difficulties, future tank operations decisions, and guidance of the current tank inspection program. Should new waste storage tanks be constructed in the future, these reviews also provide valuable lessons-learned.(authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surrogate modelling for urban building energy simulation based on the bidirectional long short-term memory model

Here, the urban microclimate is essential for accurate simulation-based urban building energy modelling (UBEM). However, a high spatial-resolution microclimate can increase the computational resources demands of UBEM. Surrogate modelling is one of the promising approaches for fast UBEM. This study proposes a bidirectional Long Short-Term Memory (LSTM)-based approach for simulation-based UBEM surrogate modelling. The estimations are aggregated into census tracts using total building floor area. A case study using UBEM to estimate annual hourly building energy use and anthropogenic heat from all existing buildings in Los Angeles County found that most of the surrogate models can complete the annual hourly simulation within 90 minutes with a normalized mean absolute error lower than 10%, and that the bidirectional LSTM outperforms the standard LSTM in accuracy. This study demonstrates the advantages of bidirectional RNN architecture in building energy surrogate modelling and is expected to promote long-term and high-resolution UBEM with detailed microclimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring cosmological distances using cluster edges as a standard ruler

ABSTRACT The line-of-sight velocity dispersion profile of galaxy clusters exhibits a ‘kink’ corresponding to the spatial extent of orbiting galaxies. Because the spatial extent of a cluster is correlated with the amplitude of the velocity dispersion profile, we can utilize this feature as a gravity-calibrated standard ruler. Specifically, the amplitude of the velocity dispersion data allows us to infer the physical cluster size. Consequently, observations of the angular scale of the ‘kink’ in the profile can be translated into a distance measurement to the cluster. Assuming the relation between cluster radius and cluster velocity dispersion can be calibrated from simulations, we forecast that with existing data from the Sloan Digital Sky Survey we will be able to measure the Hubble constant with 3.0 per cent precision. Implementing our method with data from the Dark Energy Spectroscopic Instrument (DESI) will result in a 1.3 per cent measurement of the Hubble constant. Adding cosmological supernova data improves the uncertainty of the DESI measurement to 0.7 per cent. While these error estimates are statistical only, they provide strong motivation for pursuing the necessary simulation program required to characterize and calibrate the systematic uncertainties impacting our proposed measurement. Whether or not our proposed measurement can in fact result in competitive H0 constraints will depend on what the eventual systematics floor for this method is.

79 ASTRONOMY AND ASTROPHYSICS↗

Model-based tomographic reconstruction

A model-based approach to estimating wall positions for a building is developed and tested using simulated data. It borrows two techniques from geophysical inversion problems, layer stripping and stacking, and combines them with a model-based estimation algorithm that minimizes the mean-square error between the predicted signal and the data. The technique is designed to process multiple looks from an ultra wideband radar array. The processed signal is time-gated and each section processed to detect the presence of a wall and estimate its position, thickness, and material parameters. The floor plan of a building is determined by moving the array around the outside of the building. In this paper we describe how the stacking and layer stripping algorithms are combined and show the results from a simple numerical example of three parallel walls.

97 MATHEMATICS AND COMPUTING↗

A machine learning method of modern urban building energy modeling: A case study of Chicago

Urban-scale building energy modeling is vital for urban planning. However, it can be challenging to assimilate reliable non-geometry building data for urban-scale modeling without extensive investment. Here, this study introduces a novel approach to developing modern urban-scale building energy stock data using geographic information systems and machine learning algorithms without necessarily requiring pre-supplied non-geometric metadata. The proposed framework integrates building footprint and height data to estimate gross floor areas, and matches each building to a pool of candidate records from ComStock or ResStock—filtered to the same county and ranked by geometric similarity—demonstrate a proof-of-concept case study in Chicago for predicting energy use intensity (EUI) using scalable datasets. The model achieved a mean bias error (MBE) of 0.08 kWh/m² and root mean square error (RMSE) of 14.84 kWh/m² under full metadata input for EUI prediction. With only location inputs, the model captured 69.2 % of EUI within predicted ranges. These results demonstrate the model’s potential to support early-stage urban planning, identify candidates for energy-efficient retrofits. By removing the dependency on detailed pre-surveys or extensive building metadata, the approach overcomes a key barrier in traditional urban-scale building energy modeling, illustrating a pathway toward broader and more cost-effective application, though further multi-city validation and improved treatment of pre-1925 buildings are needed.

Energy Use Intensity↗

R and DE Robotic Sensor Intern Team: Sensor Suite Mock Up Testing

Assess sensor suite performance: - Mounted on crawler typical to what would be used in tunnel; - In test bed simulating the tunnel environment. The SuperDroid fiber tethered LT-F crawler is a general-purpose surveillance robot that our team has refurbished as a testing platform for the sensor suite. This crawler was selected because its dimensions are similar to the actual crawler that will be deployed in the field. Crawler preparation included: - Communicating with vendor to resolve software and platform issues; - Configuring a laptop with the crawler control software; - Reconfiguration of communication protocol between computer and crawler; - Resolution of control board checksum errors; - Installation of a mounting fixture on the base; - In progress: addition of lighting needed for total darkness. A solution for hosting the selected sensors onto a single unit that could function standalone or be mounted on the crawler was needed. Sensor mount requirements included: - Host Lidar, panospheric cameras and IMU sensors; - Cable management for rotating Lidar; - House on-board crawler computer; - Method for affixing to crawler; - Robust and vibration proof. The Lidar sensor required a sturdy mount that ensured the axis of rotation be centered with the LiDAR's desired laser path and included a slender profile in order to not block the scanning FOV. The mounting plate holds two 180-degree cameras on either side and the servo on the center. The servo mount is located so the axis of rotation is in the center of the plate. The mount features a set of guides that hold the wires and ensure they wrap around the spool area properly. The sensor box design features thick walls for added strength, holes for mounting the sensor suite to the crawler, notches on the bottom for the different components and holes for cable routing and management. The sensor mounts were designed using CREO and printed in the R and DE Additive Manufacturing Lab. To test the performance of the sensor suite for our application it was desired to design and build a test bed simulating the H-Canyon tunnel environment. Requirements included: - Dimensions similar to the tunnel; - Wall surfaces simulating the eroded tunnel walls; - Complete darkness; - Even and uneven crawler path; - Ability to change the tunnel width to simulate erosion. The HCAEX tunnel changes in height and includes several bends ranging from approximately 30 to 80 degrees, for that reason a test bed capable of easily being changed was needed. The final design includes two sections that can be connected to provide a 16' tunnel or placed at an angle to create a tunnel bend. The test bed features caster wheels for easy movement and has a sliding inner wall that enables tunnel width to be controlled. In order to simulate the tunnel walls without adding a lot of weight to the test bed, sheets of faux stone are to be used on the inner walls. To create a completely dark tunnel, 100% black-out film will be draped over the tunnel structure. Carpet remnants in the lab will enable folds to be introduced in the floor to generate uneven surface data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Double-Shell Tank Extent-of-Condition Construction Review

During routine visual inspections of Hanford double-shell waste tank 241-AY-102 (AY-102), anomalies were identified on the annulus floor which resulted in further evaluations. Following a formal leak assessment in October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of AY-102 was leaking. The formal leak assessment, documented in RPP-ASMT-53793,Tank 241-AY-102 Leak Assessment Report, identified first-of-a-kind construction difficulties and trial-and-error repairs as major contributing factors to tank failure. To determine if improvements in double-shell tank (DST) construction occurred after construction of tank AY-102, a detailed review and evaluation of historical construction records were performed for the first three DST tank farms constructed, which included tanks 241-AY-101, 241-AZ-101, 241-AZ-102, 241-SY-101, 241-SY-102, and 241-SY-103. The review for these six tanks involved research and review of dozens of boxes of historical project documentation. These reviews form a basis to better understand the current condition of the three oldest Hanford DST farms. They provide a basis for changes to the current tank inspection program and also provide valuable insight into future tank use decisions. If new tanks are constructed in the future, these reviews provide valuable "lessons-learned" information about expected difficulties as well as construction practices and techniques that are likely to be successful.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Double-Shell Tank Extent-of-Condition Review - 15498

During routine visual inspections of Hanford double-shell waste tank 241-AY-102 (AY-102), anomalies were identified on the annulus floor which resulted in further evaluations. Following a formal leak assessment in October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of AY-102 was leaking. A formal leak assessment, documented in RPP-ASMT-53793, Tank 241-AY-102 Leak Assessment Report, identified first-of-a-kind construction difficulties and trial-and-error repairs as major contributing factors to tank failure.1 To determine if improvements in double-shell tank (DST) construction occurred after construction of tank AY-102, a detailed review and evaluation of historical construction records was performed for Hanford’s remaining twenty-seven DSTs. Review involved research of 241 boxes of historical project documentation to better understand the condition of the Hanford DST farms, noting similarities in construction difficulties/issues to tank AY-102. Information gathered provides valuable insight regarding construction difficulties, future tank operations decisions, and guidance of the current tank inspection program. Should new waste storage tanks be constructed in the future, these reviews also provide valuable lessons-learned.

Johnson, J. M.↗

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗

Servomotor-driven leveling elements for machine tool frame-to-floor alignment

This paper presents the results of aligning the frame to concrete floor of a large 5-axis machine tool by leveling element adjustments using servomotors instead of manual operation. The machine tool leveling elements used in this study are mechanical devices that attach the machine tool frame to the concrete foundation. These leveling elements are also adjustable so that each location along the machine tool can be uniquely adjusted such that the geometric errors of the frame are minimized, and the accuracy of the machine tool is improved. Off-the-shelf servomotors and connection equipment were installed at each of 12 leveling element locations for a precision 5-axis machine tool at Oak Ridge National Laboratory. The servomotors allow a technician to align the machine tool frame remotely, instead of crawling under the machine tool to iteratively manually adjust each of the 12 leveling elements. The open-loop servomotor-leveling element system design is presented in this paper as well as machine tool frame alignment results. The servomotor system significantly reduces leveling element adjustment time, eliminates the need for under-machine access, reduces technician physical strain, and significantly improves the adjustment repeatability.

Honeycutt, Andrew [ORNL]↗

Performance-based earthquake early warning for tall buildings

The ShakeAlert Earthquake Early Warning (EEW) system aims to issue an advance warning to residents on the West Coast of the United States seconds before the ground shaking arrives, if the expected ground shaking exceeds a certain threshold. However, residents in tall buildings may experience much greater motion due to the dynamic response of the buildings. Therefore, there is an ongoing effort to extend ShakeAlert to include the contribution of building response to provide a more accurate estimation of the expected shaking intensity for tall buildings. Currently, the supposedly ideal solution of analyzing detailed finite element models of buildings under predicted ground-motion time histories is not theoretically or practically feasible. The authors have recently investigated existing simple methods to estimate peak floor acceleration (PFA) and determined these simple formulas are not practically suitable. Instead, this article explores another approach by extending the Pacific Earthquake Engineering Research Center (PEER) performance-based earthquake engineering (PBEE) to EEW, considering that every component involved in building response prediction is uncertain in the EEW scenario. Additionally, while this idea is not new and has been proposed by other researchers, it has two shortcomings: (1) the simple beam model used for response prediction is prone to modeling uncertainty, which has not been quantified, and (2) the ground motions used for probabilistic demand models are not suitable for EEW applications. In this article, we address these two issues by incorporating modeling errors into the parameters of the beam model and using a new set of ground motions, respectively. We demonstrate how this approach could practically work using data from a 52-story building in downtown Los Angeles. Using the criteria and thresholds employed by previous researchers, we show that if peak ground acceleration (PGA) is accurately estimated, this approach can predict the expected level of human comfort in tall buildings.

58 GEOSCIENCES↗

CHROMOSPHERIC ACTIVITY AND JITTER MEASUREMENTS FOR 2630 STARS ON THE CALIFORNIA PLANET SEARCH

We present time series measurements of chromospheric activity for more than 2600 main-sequence and subgiant stars on the California Planet Search (CPS) program with spectral types ranging from about F5V to M4V for main-sequence stars and from G0IV to about K5IV for subgiants. The large data set of more than 44,000 spectra allows us to identify an empirical baseline floor for chromospheric activity as a function of color and height above the main sequence. We define {Delta}S as an excess in emission in the Ca II H and K lines above the baseline activity floor and define radial velocity jitter as a function of {Delta}S and B - V for main-sequence and subgiant stars. Although the jitter for any individual star can always exceed the baseline level, we find that K dwarfs have the lowest level of jitter. The lack of correlation between observed jitter and chromospheric activity in K dwarfs suggests that the observed jitter is dominated by instrumental or analysis errors and not astrophysical noise sources. Thus, given the long-term precision for the CPS program, radial velocities are not correlated with astrophysical noise for chromospherically quiet K dwarf stars, making these stars particularly well suited for the highest precision Doppler surveys. Chromospherically quiet F and G dwarfs and subgiants exhibit higher baseline levels of astrophysical jitter than K dwarfs. Despite the fact that the rms in Doppler velocities is correlated with the mean chromospheric activity, it is rare to see one-to-one correlations between the individual time series activity and Doppler measurements, diminishing the prospects for correcting activity-induced velocity variations in F and G dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗