Search NASA⌕ Search

SEARCH · Search NASA

Results for “Evaporation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluating Enhanced Reservoir Evaporation Losses From CMIP6‐Based Future Projections in the Contiguous United States

Abstract Enhanced reservoir evaporation has become an emerging concern regarding water loss, especially when compounded with the ever‐increasing water demand. In this study, we evaluated the evaporation rates and losses for 678 major reservoirs (representing nearly 90% of total storage capacity) in the Contiguous United States over historical baseline (1980–2019), near‐term (2020–2039), and mid‐term (2040–2059) future periods. The evaporation rate was estimated using the Lake Evaporation Model (LEM), an advanced lake evaporation model that addresses both heat storage and fetch effects, driven by multi‐ensemble downscaled Coupled Model Intercomparison Projects 6 (CMIP6) projections under the SSP585 emission scenario. The results project that the evaporation loss may increase by 2.5 × 10 7 m 3 /yr through the research period (1980–2059). Among all regions, the Rio Grande is projected to have the largest increasing rate in the near‐term and mid‐term future, with values of 7.11% of 10.25%, respectively. At the seasonal scale, the most significant increase in the evaporation rate is projected during the fall. The evaporation is projected to increase faster than the streamflow over many of the regions in the southwestern US during the summer/fall, suggesting that the shortage of water will be further exacerbated. The climate models contribute the most to the variance, as compared to the other components related to the projection of evaporation losses (e.g., hydrological model, downscaling method, and historical meteorological data set). These findings demonstrate the need to consider accelerated water loss through open water evaporation in long‐term water resources planning across various spatiotemporal scales.

54 ENVIRONMENTAL SCIENCES↗

Organic Evaporation and Oxidation Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 56 million gallons of radioactive mixed waste stored in 177 underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method to supplement vitrification. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste. This work evaluates potential avenues to eliminate that impediment to permit possible use of a cementitious waste form and work towards a decision whether additional LDR organic pretreatment would be required. Savannah River National Laboratory (SRNL) performed testing using simulants to examine evaporation as a method to remove some prevalent organics from LAW. Spiking the caustic LAW simulant with selected regulated organic chemicals found one that clearly decomposes because of caustic instability. Oxidation testing of other organic chemicals found some LDR organics degrade as desired and others are stable in the presence of peroxide and permanganate. In addition to studies with simulants, a literature review was performed to evaluate radiological stability of LDR organics. Descriptions of the experimental details, equipment, and results are included in this report. Evaporation testing consisted of preparing the LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation) and also at atmospheric pressure. The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na + ] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species. Organic chemicals were chosen for the work with a consideration of how their volatility compares with that of methanol. This was done by comparing the ratio of the pure water Henry’s law coefficient (K h ) of methanol to that of the compound in question (hereafter termed the K h ratio), where ratios above unity indicated less volatility than methanol. Methanol was chosen because it is a common regulated chemical with relatively low volatility but which has been removed by evaporation in previous laboratory work. While organic separation results depend on evaporator design, laboratory experiments verified that organic partitioning to the overhead condensate stream by evaporation is a practical process. The work reported here found difficulties in quantitative analysis of the organic chemicals in aqueous samples. Most of the time there was insufficient analysis to close a mass balance for evaporator runs, but qualitative evidence of carryover was obtained. The methods were also able to show whether organic chemicals were susceptible or resistant to solution oxidation in permanganate or hydrogen peroxide tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mineral Scaling in 3D Interfacial Solar Evaporators–A Challenge for Brine Treatment and Lithium Recovery

In this work, we analyzed the effects of mineral scaling on the performance of a 3D interfacial solar evaporator, with a focus on the cations relevant to lithium recovery from brackish water. The field has been rapidly moving toward resource recovery applications from brines with higher cation concentrations. However, the potential complications caused by common minerals in these brines other than NaCl have been largely overlooked. Therefore, in this study, we thoroughly examined the effects of two common cations (calcium and magnesium) on the long-term solar evaporation performance of a 3D graphene oxide stalk. The 3D stalk can achieve an evaporation flux as high as 17.8 kg m –2 h –1 under one-sun illumination, and accumulation of NaCl on the stalk surface has no impact. However, the presence of CaCl 2 and MgCl 2 significantly reduces the evaporative flux even in solutions lacking scale-forming anions. A close examination of scale formation during long-term evaporation experiments revealed that CaCl 2 and MgCl 2 tend to precipitate out within the stalk, thus blocking water transport through the stalk and significantly dropping the evaporation rates. These findings imply that research attention is needed to modify and optimize the internal water transport channels for 3D evaporators. Additionally, we emphasize the importance of testing realistic mixtures–including prominent divalent cations– and testing long-term operations in interfacial solar evaporation research and investigating approaches to mitigate the negative impacts of divalent cations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EXPERIMENTAL ANALYSIS OF SINGLE EVAPORATION TUBE UTILIZING SINTERED COPPER PARTICLE WICKING STRUCTURES

Wicking structures have been widely used within passive heat transfer devices with high heat fluxes, such as heat pipes, to enhance their thermal performance. While wicking structures promote capillary pumping of the working fluid as well as thin film evaporation, they can result in capillary evaporation and further enhances the evaporation heat transfer. In this study, a 0.5 mm thick layer of 105 microns sintered copper particles was added to the inner wall of a copper tube, aiming to enhance the heat transfer characteristics by taking advantage of capillary evaporation. Acetone was chosen as the working fluid, and the performance of an evaporation tube was tested for power inputs of 10, 30, 50, and 70 W. For each power input, trials were run at inclination angles varying from -90° and 90° to investigate the capillary effects. The temperature measurements showed that the temperature distribution along the evaporation tube is always downward sloping, meaning the temperature at the fluid inlet is larger than the outlet. Interestingly, the surface temperature at some locations is less than the outlet temperature, indicating the effect of capillary evaporation. In addition, a theoretical investigation was performed to investigate the effects of the particle size on the thermal performance of the evaporation tube and found that particle sizes affect capillary evaporation.

Wang, Pengtao↗

Gas-Phase Temperature Mapping of Evaporating Microdroplets

Evaporation is a ubiquitous and complex phenomenon of importance to many natural and industrial systems. Evaporation occurs when molecules near the free interface overcome intermolecular attractions with the bulk liquid. As molecules escape the liquid phase, heat is removed, causing evaporative cooling. The influence of evaporative cooling on inducing a temperature difference with the surrounding atmosphere as well as within the liquid is poorly understood. Here, we develop a technique to overcome past difficulties encountered during the study of heterogeneous droplet evaporation by coupling a piezo-driven droplet generation mechanism to a controlled micro-thermocouple to probe microdroplet evaporation. The technique allowed us to probe the gas-phase temperature distribution using a micro-thermocouple (50 μm) in the vicinity of the liquid–vapor interface with high spatial (±10 μm) and temporal (±100 ms) resolution. We experimentally map the temperature gradient formed surrounding sessile water droplets having varying curvature dictated by the apparent advancing contact angle (100° ≲ θ ≲ 165°). The experiments were carried out at temperatures below and above ambient for a range of fixed droplet radii (130 μm ≲ R ≲ 330 μm). Our results provide a primary validation of the centuries-old theoretical framework underpinning heterogeneous droplet evaporation mediated by the working fluid, substrate, and gas thermophysical properties, droplet apparent contact angle, and droplet size. We show that microscale droplets residing on low-thermal-conductivity substrates such as glass absorb up to 8× more heat from the surrounding gas compared to droplets residing on high-thermal-conductivity substrates such as copper. Finally, our work not only develops an experimental understanding of the heat transfer mechanisms governing droplet evaporation but also presents a powerful platform for the study and characterization of liquid–vapor transport at curved interfaces wetting and nonwetting advanced functional surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaporation of Water Nanodroplets on Heated Surfaces: Does Nano Matter?

While experiments and continuum models have provided a relatively good understanding of the evaporation of macroscopic water droplets, elucidating how sessile nanodroplets evaporate is an open question critical for advancing nanotechnological applications where nanodroplets can play an essential role. In this study, using molecular dynamics simulations, we find that evaporating nanodroplets, in contrast to their macroscopic counterparts, are not always in thermal equilibrium with the substrate and that the vapor concentration on the nanodroplet surface does not reach a steady state. As a result, the evaporative behavior of nanodroplets is significantly different. Regardless of hydrophobicity, nanodroplets do not follow conventional evaporation modes but instead exhibit dynamic wetting behavior characterized by huge, non-equilibrium, isovolumetric fluctuations in the contact angle and contact radius. For hydrophilic nanodroplets, the evaporation rate, controlled by the vapor concentration, decays exponentially over time. Hydrophobic nanodroplets follow stretched exponential kinetics arising from the slower thermalization with the substrate. The evaporative half-lifetime of the nanodroplets is directly related to the thermalization time scale and therefore increases monotonically with the hydrophobicity of the substrate. Finally, the evaporative flux profile along the nanodroplet surface is highly nonuniform but does not diverge at the contact line as the macroscopic continuum models predict.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Experimental Investigation of Sintered Particle Effect on Heat Transfer Performance in an “Annular Flow” Evaporation Tube

Wicking structures have been widely used within passive heat transfer devices with high heat fluxes, such as heat pipes, to enhance their thermal performance. While wicking structures promote capillary pumping of the working fluid and thin film evaporation, they can result in capillary evaporation and further enhance the evaporation heat transfer. In this study, a 0.5 mm thick layer of 105 µm sintered copper particles was added to the inner wall of a copper tube, aiming to form an “annular flow” and enhance the heat transfer characteristics by taking advantage of thin film and capillary evaporation. Acetone was chosen as the working fluid, and the performance of an evaporation tube was tested for power inputs of 10, 30, 50, and 70 W. For each power input, trials were run at inclination angles varying from -90 deg to 90 deg to investigate the capillary effects. The temperature measurements showed that the temperature distribution along the evaporation tube is always downward sloping, meaning the temperature at the fluid inlet is larger than the outlet. In conclusion, results show that an “annular flow” formed by a thin layer of sintered particles can promote thin film and capillary evaporation and, therefore, boost the evaporation heat transfer coefficient.

42 ENGINEERING↗

Evaporative water loss of 1.42 million global lakes

The evaporative loss from global lakes (natural and artificial) is a critical component of the terrestrial water and energy balance. However, the evaporation volume of these water bodies—from the spatial distribution to the long-term trend—is as of yet unknown. Here, using satellite observations and modeling tools, we quantified the evaporation volume from 1.42 million global lakes from 1985 to 2018. We find that the long-term average lake evaporation is 1500 ± 150 km 3 year -1 and it has increased at a rate of 3.12 km 3 year -1 . The trend attributions include an increasing evaporation rate (58%), decreasing lake ice coverage (23%), and increasing lake surface area (19%). While only accounting for 5% of the global lake storage capacity, artificial lakes (i.e., reservoirs) contribute 16% to the evaporation volume. Our results underline the importance of using evaporation volume, rather than evaporation rate, as the primary index for assessing climatic impacts on lake systems.

54 ENVIRONMENTAL SCIENCES↗

Impact of Floating PV (FPV) System on Water Evaporation: Case Study of an Open Loop Reservoir in North Carolina

Fresh water scarcity is becoming one of the important concerns worldwide. This situation of water scarcity is further exacerbated by the increase in water evaporation due to climate change. This manuscript will address this concern by considering the impact of floating photovoltaics (FPVs) systems on water evaporation. The installation of PV modules on the water bodies can help reduce the water evaporation rate from reservoirs by reducing the evaporating area of the water surface. This work evaluates the effect of FPV on water evaporation rates in the TuckerTown reservoir located in North Carolina state of United States. Meteorological data, such as mean temperature and dew-point, are used to calculate the rate of the water evaporation by Linacre method. The simulation results for the TuckerTown case study showed that the aggregated avoided evaporated volume for one year is 9 million gallons.

14 SOLAR ENERGY↗

Evaporation from thin porous Coatings: Pore size effects and predictive equation for homogeneous coatings

Evaporation of small water droplets on solids is hindered because surface tension pulls the droplet into a spherical cap that has a small perimeter. Our solution is to coat a solid with a very thin, porous layer into which the droplet flows to create a large-area disk with concomitant high rate of evaporation. We investigate evaporation by varying factors that have not been previously considered: pore size and distribution, contact angle, temperature, and relative humidity (RH). A larger pore size resulted in faster evaporation, which we explain through faster transport within the coating. Even faster evaporation occurred for a bilayer structure with small particles on the air side and larger particles on the solid side. Further, the water advancing contact angle had an insignificant effect in the range from < 10° through to 60°. Our results for different pore sizes, temperature, humidity, and contact angle all collapse onto a single curve when appropriately normalized. This validates an equation that can be used for the evaporation from a homogeneous coating that depends only one empirical factor and the droplet volume. Since the volume is often user-controlled, we envisage that this equation can be used to predict evaporation and guide design of fast-drying coatings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental investigation of elemental and isotopic evaporation processes by laser heating in an aerodynamic levitation furnace

In this report we carried out evaporation experiments on a B-type calcium–aluminium-rich inclusion (CAI) melt in a gas-mixing aerodynamic levitation laser furnace, at 1873 K and an oxygen partial pressure of 10 -9.1 atm, for durations ranging from 60 to 600 s. Evaporation of SiO 2 and MgO follow the same trend as those observed in vacuum furnace experiments at the same temperature and starting composition, showing that their evaporation relative to one another from the melt is independent of pressure, oxygen fugacity, and hydrodynamical regime specific to the furnace. Isotopic ratios of Mg and Si in evaporation residues are used to derive fractionation factors of α 26/24 Mg vap-liq = 0.9906± 0.0004 and α 30/28 Si vap-lip = 0.9943±0.0003, which are both significantly closer to unity than those found for evaporation in a vacuum, which translates to less isotope fractionation. The residues are also less isotopically fractionated than expected for cases in which transport of the gas species away from the melt is diffusion-controlled at 1-atm. By analysing the flow regimes in our furnace, we find that advection by the levitating gas is the primary mode of mass transport away from the melt surface, as opposed to diffusion-limited transport in a vacuum or 1-atm tube furnace. A modified Hertz–Knudsen–Langmuir formulation accounts for this process, and shows that isotopic fractionation of both Si and Mg reflect a saturation factor (ratio of the pressure of the evaporating species to vapour saturation pressure) equal to 0.75. This is in perfect accord with recent measurements of Cu isotopic fractionation using a similar furnace. The fact that three elements (Mg, Si, Cu) with varying equilibrium vapour pressures, activity coefficients in the liquid, and diffusion coefficients in the gas have the same scaling behaviour to saturation pressure is a strong indication that the mechanism controlling evaporation is driven by the hydrodynamical regime imposed in the furnace. Therefore, this class of experiments can be used to constrain processes in which advection dominates over diffusion, such as (but not limited to) planetary ejecta, tektites, giant impacts, nebular condensation in a turbulent flow, or nuclear fallout material. Finally, the possibility to reach high temperatures (in excess of 3500 K) in this furnace allows it to be used to evaluate the activity coefficients of melt components in extreme conditions relevant to molten planetary interiors (i.e., magma oceans), with a specific focus on refractory elements.

58 GEOSCIENCES↗

Ensemble modeling of global lake evaporation under climate change

Global projections of lake evaporation are typically based on simulations using single mechanistic models. However, because of its complex interactions with various lake physical properties, environmental and anthropogenic drivers, lake evaporation is highly variable and sensitive to the choice of model used. In this study, we present a multi-model analysis to investigate differences across global simulations of lake evaporation during the warm-season using three different lake models driven by outputs from four general circulation models (GCM) (i.e. 12 model combinations in total) for historic and future scenarios. Our results suggest substantial differences among lake-climate model simulations of lake evaporation. These differences varied throughout the 20th and 21st century, with model driver data explaining 74% of the variance in future projections of warm- season lake evaporation. Our projections indicate that, by the end of the 21st century (2070–2099), global annual lake evaporation rates will increase by 10–27% under Representative Concentration Pathways (RCPs) 2.6–8.5. Finally, we highlight the importance of using a multi-model approach for the prediction of future global lake evaporation responses to climate change.

54 ENVIRONMENTAL SCIENCES↗

On falling film evaporator – A review of mechanisms and critical assessment of correlation on a horizontal tube bundle with updated development

Optimization of the energy efficiency and reduction of the greenhouse gas emission for the heat pump system is imperative to meet the net-zero goals at 2050. Chillers with falling film evaporator design not only possess better system performance but also contain less refrigerant inventory. Hence, accurate prediction of the evaporator performance is pivotal especially when charged with low-GWP refrigerant. Here, the study reviews the correlations for falling film evaporator with a horizontal tube bundle configuration. The major efforts of this study include four tasks: (a) literature review of the experimental studies and available empirical correlations; (b) comprehensive discussion of the falling film evaporation heat transfer mechanism; (c) development of a new rationally based correlation based on available literature; and (d) comparison of different correlations based on the existing data. The collected data includes 4114 data points from 8 sources, 6 refrigerants (R-600a, R-290, R-245fa, R-134a, R-1234ze(E), R-123), 5 types of the tubes (Plain, Turbo-GII-HP, GEWA-B, Low-fin, High-Flux), liquid Weber number from 2.2 × 10 –6 to 0.7, imposed vapor Weber number from 0 to 37.2, heat flux from 2.5 to 151.5 kW/m 2 , and film Reynolds number from 1 to 3159.8. The new correlation gives a MAD of 28.3%, and an R 2 of 0.86. Yet, the developed correlation considers various heat transfer mechanisms, including the transition point from falling film evaporation to the nucleate boiling, local evaporation, dry-out, mist flow, imposed flow, and enhanced tube effects.

42 ENGINEERING↗

Elucidating the Mechanism of Helium Evaporation from Liquid Water

Here, we investigate the evaporation of trace amounts of helium solvated in liquid water using molecular dynamics simulations and theory. Consistent with experimental observations, we find a super-Maxwellian distribution of kinetic energies of evaporated helium. This excess of kinetic energy over typical thermal expectations is explained by an effective continuum theory of evaporation based on a Fokker–Planck equation, parametrized molecularly by a potential of mean force and position-dependent friction. Using this description, we find that helium evaporation is strongly influenced by the friction near the interface, which is anomalously small near the Gibbs dividing surface due to the ability of the liquid–vapor interface to deform around the gas particle. Our reduced description provides a mechanistic interpretation of trace gas evaporation as the motion of an underdamped particle in a potential subject to a viscous environment that varies rapidly across the air–water interface. From it we predict the temperature dependence of the excess kinetic energy of evaporation, which is yet to be measured.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights Into the Aerodynamic Versus Radiometric Surface Temperature Debate in Thermal-Based Evaporation Modeling

Global evaporation monitoring from Earth observation thermal infrared satellite missions is historically challenged due to the unavailability of any direct measurements of aerodynamic temperature. State-of-the-art one-source evaporation models use remotely sensed radiometric surface temperature as a substitute for the aerodynamic temperature and apply empirical corrections to accommodate for their inequality. This introduces substantial uncertainty in operational drought mapping over complex landscapes. By employing a non-parametric model, we show that evaporation can be directly retrieved from thermal satellite data without the need of any empirical correction. Independent evaluation of evaporation in a broad spectrum of biome and aridity yielded statistically significant results when compared with eddy covariance observations. While our simplified model provides a new perspective to advance spatio-temporal evaporation mapping from any thermal remote sensing mission, the direct retrieval of aerodynamic temperature also generates the highly required insight on the critical role of biophysical interactions in global evaporation research.

54 ENVIRONMENTAL SCIENCES↗

Microphysics Dominates Sub‐Cloud Rain Evaporation in Trade Cumuli Over Barbados

This study investigates the microphysical and thermodynamic influences on North Atlantic trade-cumulus rain evaporation in the sub-cloud layer over Barbados from January to November 2020. Using radar observations and a 1-D model, the results reveal that microphysical properties, namely geometric mean diameter (D g ) and raindrop concentration, primarily control evaporation processes under conditions of limited thermodynamic variability. Thermodynamic factors like cloud base height and relative humidity exert a smaller influence due to their narrow observed ranges. Small D g leads to rapid increases in rain evaporation fraction (REF), as small drops evaporate completely, while larger D g yields slower, more gradual REF changes. Frequent weak-rain cases reduce the mean evaporation flux, whereas infrequent intense-rain events substantially enhance it. These findings highlight the pivotal role of microphysical variability in shaping sub-cloud evaporation in this trade cumulus regime, while thermodynamic effects may be more important in other environments.

54 ENVIRONMENTAL SCIENCES↗

Laser heating and evaporation of a single droplet

The laser technology is being abundantly studied for controlled energy deposition for a range of applications in aerodynamic flow control, material processing, ignition, and combustion. The absorption of laser radiation by liquid droplets affects further propagation of laser in the atmosphere and causes bleaching of suspended droplets while the ignition and combustion characteristics in combustors are influenced by the evaporation rate of the sprayed fuel. In this work, we present a multi-dimensional mathematical model built on OpenFOAM for laser heating and evaporation of a single droplet in the diffusion dominated regime taking into account absorption of the laser radiation, evaporation process and vapor flow dynamics. The developed solver is validated against available experimental and numerical data for the ethanol and water droplet heating and evaporation. For continuous heating the peak temperature is established by the balance of cooling, evaporation and heating and results in high temperature for larger droplets. It has been shown that for heating by a single laser pulse the maximum temperature of droplets depends only on the peak intensity of the laser radiation. Furthermore, for the peak irradiance close to the transition to the boiling regime, temporal dynamics of the droplet temperature is independent of the droplet size. With proper normalization of time, the dynamics of the droplet shrinkage and cooling is shown to be independent of droplet sizes and peak laser intensities. The influence of cooling and evaporation processes on droplet heating was found to be controlled by the pulse repetition rate for repeated pulse operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deuteron Evaporation from N = Z Compound Nuclei

Deuteron evaporation was observed from the N = Z compound nuclei 52 Fe ⋆ , 56 Ni ⋆ , and 64 Ge ⋆ in an experiment conducted at Argonne National Laboratory, USA. The experiment included a novel combination of two highly pixelated double-sided Si-strip detectors inside the Microball chargedparticle detection array, allowing for unequivocal discrimination of evaporated deuterons from protons and α particles. In conjunction with the Gammasphere array, Neutron Shell, and additional ancillary detectors, decay paths into various residual nuclei were investigated. The study provides insights into the competition of deuteron vs. proton-neutron evaporation as a function of available excitation energy and populated angular momentum. Results are interpreted using a statistical evaporation formalism for multiple subsequent particle emissions. The decisive factor in the comparison appears to be the available excitation energy in the residual system, with single nucleon evaporation preferred over deuteron evaporation for higher excitation energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗