Search NASA⌕ Search

SEARCH · Search NASA

Results for “Exercise Therapy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

USTUR WHOLE BODY CASE 0269: DEMONSTRATING EFFECTIVENESS OF I.V. CA-DTPA FOR PU

This whole body donation case (USTUR Registrant) involved a single acute inhalation of an acidic Pu(NO3)4 solution in the form of an aerosol ‘mist.’ Chelation treatment with i.v. Ca-EDTA was initiated on the day of the intake, and continued intermittently over 6 months. After 2½ years with no further treatment, a course of i.v. Ca-DTPA was administered. A total of 400 measurements of 239+240Pu excreted in urine were recorded; starting on the first day (both before and during the initial Ca-EDTA chelation), and continuing for 37 years. This sampling included all intervals of chelation. In addition, 91 measurements of 239+240Pu-in-feces were recorded over this whole period. The Registrant died about 38 years after the intake, at age 79 y, with extensive carcinomatosis secondary to adenocarcinoma of the prostate gland. At autopsy, all major soft tissue organs were harvested for radiochemical analyses of their 238Pu, 239+240Pu and 241Am content. Also, all types of bone (comprising about half the skeleton) were harvested for radiochemical analyses, as well as samples of skin, subcutaneous fat and muscle. This comprehensive dataset has been applied to derive ‘chelation-enhanced’ transfer rates in the ICRP Publication 67 plutonium biokinetic model, representing the behaviour of blood-borne and tissue-incorporated plutonium during intervals of therapy. The resulting model of the separate effects of i.v. Ca-EDTA and Ca-DTPA chelation shows that the therapy administered in this case succeeded in reducing substantially the long-term burden of plutonium in all body organs, except for the lungs. The calculated reductions in organ content at the time of death are approximately 40% for the liver, 60% for other soft tissues (muscle, skin, glands, etc.), 50% for the kidneys, and 50% for the skeleton. Essentially all of the substantial reduction in skeletal burden occurred in trabecular bone. This modeling exercise demonstrated that 3-y-delayed Ca-DTPA therapy was as effective as promptly administered Ca-EDTA.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Research Agenda for Radiation Oncology: Results of the Radiation Oncology Institute's Comprehensive Research Needs Assessment

Purpose: To promote the rational use of scarce research funding, scholars have developed methods for the systematic identification and prioritization of health research needs. The Radiation Oncology Institute commissioned an independent, comprehensive assessment of research needs for the advancement of radiation oncology care. Methods and Materials: The research needs assessment used a mixed-method, qualitative and quantitative social scientific approach, including structured interviews with diverse stakeholders, focus groups, surveys of American Society for Radiation Oncology (ASTRO) members, and a prioritization exercise using a modified Delphi technique. Results: Six co-equal priorities were identified: (1) Identify and develop communication strategies to help patients and others better understand radiation therapy; (2) Establish a set of quality indicators for major radiation oncology procedures and evaluate their use in radiation oncology delivery; (3) Identify best practices for the management of radiation toxicity and issues in cancer survivorship; (4) Conduct comparative effectiveness studies related to radiation therapy that consider clinical benefit, toxicity (including quality of life), and other outcomes; (5) Assess the value of radiation therapy; and (6) Develop a radiation oncology registry. Conclusions: To our knowledge, this prioritization exercise is the only comprehensive and methodologically rigorous assessment of research needs in the field of radiation oncology. Broad dissemination of these findings is critical to maximally leverage the impact of this work, particularly because grant funding decisions are often made by committees on which highly specialized disciplines such as radiation oncology are not well represented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A snapshot of radiation therapy techniques and technology in Queensland: An aid to mapping undergraduate curriculum

Undergraduate students studying the Bachelor of Radiation Therapy at Queensland University of Technology (QUT) attend clinical placements in a number of department sites across Queensland. To ensure that the curriculum prepares students for the most common treatments and current techniques in use in these departments, a curriculum matching exercise was performed. A cross-sectional census was performed on a pre-determined “Snapshot” date in 2012. This was undertaken by the clinical education staff in each department who used a standardized proforma to count the number of patients as well as prescription, equipment, and technique data for a list of tumour site categories. This information was combined into aggregate anonymized data. All 12 Queensland radiation therapy clinical sites participated in the Snapshot data collection exercise to produce a comprehensive overview of clinical practice on the chosen day. A total of 59 different tumour sites were treated on the chosen day and as expected the most common treatment sites were prostate and breast, comprising 46% of patients treated. Data analysis also indicated that intensity-modulated radiotherapy (IMRT) use is relatively high with 19.6% of patients receiving IMRT treatment on the chosen day. Both IMRT and image-guided radiotherapy (IGRT) indications matched recommendations from the evidence. The Snapshot method proved to be a feasible and efficient method of gathering useful data to inform curriculum matching. Frequency of IMRT use in Queensland matches or possibly exceeds that indicated in the literature. It is recommended that future repetition of the study be undertaken in order to monitor trends in referral patterns and new technology implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-598: Parametric Equation for Quick and Reliable Estimate of Stray Neutron Doses in Proton Therapy and Application for Intracranial Tumor Treatments

Purpose: Development of a parametric equation suitable for a daily use in routine clinic to provide estimates of stray neutron doses in proton therapy. Methods: Monte Carlo (MC) calculations using the UF-NCI 1-year-old phantom were exercised to determine the variation of stray neutron doses as a function of irradiation parameters while performing intracranial treatments. This was done by individually changing the proton beam energy, modulation width, collimator aperture and thickness, compensator thickness and the air gap size while their impact on neutron doses were put into a single equation. The variation of neutron doses with distance from the target volume was also included in it. Then, a first step consisted in establishing the fitting coefficients by using 221 learning data which were neutron absorbed doses obtained with MC simulations while a second step consisted in validating the final equation. Results: The variation of stray neutron doses with irradiation parameters were fitted with linear, polynomial, etc. model while a power-law model was used to fit the variation of stray neutron doses with the distance from the target volume. The parametric equation fitted well MC simulations while establishing fitting coefficients as the discrepancies on the estimate of neutron absorbed doses were within 10%. The discrepancy can reach ∼25% for the bladder, the farthest organ from the target volume. Finally, the validation showed results in compliance with MC calculations since the discrepancies were also within 10% for head-and-neck and thoracic organs while they can reach ∼25%, again for pelvic organs. Conclusion: The parametric equation presents promising results and will be validated for other target sites as well as other facilities to go towards a universal method.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Case Study of Tunable White LED Lighting with Networked Lighting Controls (Emory University Cognitive Empowerment Program)

Emory University and Georgia Institute of Technology (Georgia Tech) partnered to create the Charlie and Harriet Schaffer Cognitive Empowerment Program (CEP) facility in northeast Atlanta. Together with the funders they are building a program to help individuals experiencing mild cognitive impairment (MCI) to maintain their physical and cognitive health, and independence as long as possible. In addition to applying effective strategies and therapies, the two research groups are investigating the responses of the MCI members to treatments that involve acoustical conditions, exercise and movement, and lighting changes that may support retention or relearning of skills. Care partners and family members receive support and instruction to improve home and work life, promoting joy, purpose, and wellness in the family groups. The lighting system uses tunable-white LEDs, employing luminaires with both warm and cool-color emitters that can be dimmed separately to produce any white correlated color temperature (CCT) between 2700 K and 6500 K. All luminaires were dimmable to achieve subdued or lively surroundings for different treatments, time-of-day, and mood. A central networked digital control system was employed to allow tuning of multiple spaces together (for example, bright, cool morning light could be programmed for extra stimulation, or lighting in all spaces at the end of the day could be reduced in both light output and CCT to promote relaxation and not interfere with the melatonin cycle of occupants). Almost all spaces were equipped with individual room control of dimming and color temperature with touch screens to allow users to tune the lighting as desired, but each room’s controls could also be specially programmed through the server in case the research staff were investigating lighting settings on learning, for example. The server incorporates a timeclock, and it is able to send signals to switch off all lighting after occupancy hours, or enable occupancy sensors to control the lighting. The bulk of the construction work was completed in January 2020. It was clear from an initial walk-through that although the lighting system produced the expected high light level with low-glare qualities of light, that there were issues and inconsistencies to be resolved. These were noted in an initial punchlist visit and expected to be resolved when the tech representatives from the agency visited with the electrical contractor in the following few weeks. What followed was 2.5 years of identifying unexpected lighting performance in terms of light output, color, scheduling, and occupancy. This report documents the issues encountered in the effort to get the lighting and controls systems to operate as intended. It concludes with guidance for design professionals and manufacturers to help avoid problematic complexity in future projects.

42 ENGINEERING↗

Multicenter Collaborative Quality Assurance Program for the Province of Ontario, Canada: First-Year Results

Purpose: The objective of this work was to develop a collaborative quality assurance (CQA) program to assess the performance of intensity modulated radiation therapy (IMRT) planning and delivery across the province of Ontario, Canada. Methods and Materials: The CQA program was designed to be a comprehensive end-to-end test that can be completed on multiple planning and delivery platforms. The first year of the program included a head-and-neck (H and N) planning exercise and on-site visit to acquire dosimetric measurements to assess planning and delivery performance. A single dosimeter was used at each institution, and the planned to measured dose agreement was evaluated for both the H and N plan and a standard plan (linear-accelerator specific) that was created to enable a direct comparison between centers with similar infrastructure. Results: CQA program feasibility was demonstrated through participation of all 13 radiation therapy centers in the province. Planning and delivery was completed on a variety of infrastructure (treatment planning systems and linear accelerators). The planning exercise was completed using both static gantry and rotational IMRT, and planned-to-delivered dose agreement (pass rates) for 3%/3-mm gamma evaluation were greater than 90% (92.6%-99.6%). Conclusions: All centers had acceptable results, but variation in planned to delivered dose agreement for the same planning and delivery platform was noted. The upper end of the range will provide an achievable target for other centers through continued quality improvement, aided by feedback provided by the program through the use of standard plans and simple test fields.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Circulating Tumour Cell Numbers Correlate with Platelet Count and Circulating Lymphocyte Subsets in Men with Advanced Prostate Cancer: Data from the ExPeCT Clinical Trial (CTRIAL-IE 15-21)

Interactions between circulating tumour cells (CTCs) and platelets are thought to inhibit natural killer(NK)-cell-induced lysis. We attempted to correlate CTC numbers in men with advanced prostate cancer with platelet counts and circulating lymphocyte numbers. Sixty-one ExPeCT trial participants, divided into overweight/obese and normal weight groups on the basis of a BMI ≥ 25 or <25, were randomized to participate or not in a six-month exercise programme. Blood samples at randomization, and at three and six months, were subjected to ScreenCell filtration, circulating platelet counts were obtained, and flow cytometry was performed on a subset of samples (n = 29). CTC count positively correlated with absolute total lymphocyte count (r 2 = 0.1709, p = 0.0258) and NK-cell count (r 2 = 0.49, p < 0.0001). There was also a positive correlation between platelet count and CTC count (r 2 = 0.094, p = 0.0001). Correlation was also demonstrated within the overweight/obese group (n = 123, p < 0.0001), the non-exercise group (n = 79, p = 0.001) and blood draw samples lacking platelet cloaking (n = 128, p < 0.0001). By flow cytometry, blood samples from the exercise group (n = 15) had a higher proportion of CD3+ T-lymphocytes (p = 0.0003) and lower proportions of B-lymphocytes (p = 0.0264) and NK-cells (p = 0.015) than the non-exercise group (n = 14). These findings suggest that CTCs engage in complex interactions with the coagulation cascade and innate immune system during intravascular transit, and they present an attractive target for directed therapy at a vulnerable stage in metastasis.

60 APPLIED LIFE SCIENCES↗

Optimizing Radiation Therapy Quality Assurance in Clinical Trials: A TROG 08.03 RAVES Substudy

Purpose: To explore site- and clinician-level factors associated with protocol violations requiring real-time-review (RTR) resubmission in a multicenter clinical trial to help tailor future quality assurance (QA) protocols. Methods and Materials: RAVES (Radiation Therapy–Adjuvant vs Early Salvage) (Trans-Tasman Radiation Oncology Group 08.03) is a randomized trial comparing adjuvant with early salvage radiation therapy in men with positive surgical margins or pT3 disease after prostatectomy. Quality assurance in RAVES required each clinician and site to submit a credentialing dummy run (DR) and for each patient's radiation therapy plan to undergo external RTR before treatment. Prospectively defined major violations from trial protocol required remedy and resubmission. Site and clinician factors associated with RTR resubmission were examined using hierarchical modeling. Results: Data were collected from 171 consecutive patients, treated by 46 clinicians at 32 hospitals. There were 47 RTR resubmissions (27%) due to 65 major violations. The relative rate of resubmission decreased by 29% per year as the study progressed (odds ratio OR. 0.71, P=.02). The majority of resubmissions were due to contouring violations (39 of 65) and dosimetric violations (22 of 65). For each additional patient accrued, significant decreases in RTR resubmission were seen at both clinician level (OR 0.75, P=.02) and site level (OR 0.72, P=.01). The rate of resubmission due to dosimetric violations was only 1.6% after the first 5 patients. Use of IMRT was associated with lower rates of resubmission compared with 3-dimensional conformal radiation therapy (OR 0.38, P=.05). Conclusion: Several low- and high-risk factors that may assist with tailoring future clinical trial QA were identified. Because the real-time resubmission rate was largely independent of the credentialing exercise, some form of RTR QA is recommended. The greatest benefit from QA was derived early in trial activation and clinician experience.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating Swallowing Muscles Essential for Hyolaryngeal Elevation by Using Muscle Functional Magnetic Resonance Imaging

Purpose: Reduced hyolaryngeal elevation, a critical event in swallowing, is associated with radiation therapy. Two muscle groups that suspend the hyoid, larynx, and pharynx have been proposed to elevate the hyolaryngeal complex: the suprahyoid and longitudinal pharyngeal muscles. Thought to assist both groups is the thyrohyoid, a muscle intrinsic to the hyolaryngeal complex. Intensity modulated radiation therapy guidelines designed to preserve structures important to swallowing currently exclude the suprahyoid and thyrohyoid muscles. This study used muscle functional magnetic resonance imaging (mfMRI) in normal healthy adults to determine whether both muscle groups are active in swallowing and to test therapeutic exercises thought to be specific to hyolaryngeal elevation. Methods and Materials: mfMRI data were acquired from 11 healthy subjects before and after normal swallowing and after swallowing exercise regimens (the Mendelsohn maneuver and effortful pitch glide). Whole-muscle transverse relaxation time (T2 signal, measured in milliseconds) profiles of 7 test muscles were used to evaluate the physiologic response of each muscle to each condition. Changes in effect size (using the Cohen d measure) of whole-muscle T2 profiles were used to determine which muscles underlie swallowing and swallowing exercises. Results: Post-swallowing effect size changes (where a d value of >0.20 indicates significant activity during swallowing) for the T2 signal profile of the thyrohyoid was a d value of 0.09; a d value of 0.40 for the mylohyoid, 0.80 for the geniohyoid, 0.04 for the anterior digastric, and 0.25 for the posterior digastric-stylohyoid in the suprahyoid muscle group; and d values of 0.47 for the palatopharyngeus and 0.28 for the stylopharyngeus muscles in the longitudinal pharyngeal muscle group. The Mendelsohn maneuver and effortful pitch glide swallowing exercises showed significant effect size changes for all muscles tested, except for the thyrohyoid. Conclusions: Muscles of both the suprahyoid and the longitudinal pharyngeal muscle groups are active in swallowing, and both swallowing exercises effectively target muscles elevating the hyolaryngeal complex. mfMRI is useful in testing swallowing muscle function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Involvement of Cot activity in the proliferation of ALCL lymphoma cells

Highlights: {yields} We show here that ALCL lymphoma cell lines present high levels of Cot (MAP3K8). {yields} We show that Cot mediates the constitutive Erk1/2 activation in SUDHL-1 cells. {yields} Inhibition of Cot activity reduces the number of cell divisions in SUDHL-1 cells. {yields} Cot controls the activation state of p70 S6K and JunB expression in SUDHL-1 cells. -- Abstract: Anaplastic large-cell lymphoma (ALCL) cells overexpress CD30 on their cell surface, show increased levels of activated Erk1/2 and of JunB; participating JunB in the proliferative capacity of these lymphomas. Here, we show that ALCL lymphoma cells also present high expression levels of the proto-oncogenic Cot (MAP3K8). Using pharmacological drugs as well as the RNA interference technique we show that Cot protein is responsible for the constitutive Erk1/2 activation in the ALCL lymphoma cells, SUDHL-1. Besides, inhibition of Cot activity reduces the number of cell divisions which is achieved, at least in part, by the control that Cot exercises on the activation state of p70 S6K and on the expression levels of JunB. Since Cot represents an alternative mode, independently of RAF, to activate Erk1/2, all these data strongly suggest that molecular targeting of Cot may be a potential new specific strategy for ALCL lymphomas therapy, without the fully disturbance of the Erk1/2 function.

60 APPLIED LIFE SCIENCES↗

'Pharyngocise': Randomized Controlled Trial of Preventative Exercises to Maintain Muscle Structure and Swallowing Function During Head-and-Neck Chemoradiotherapy

Purpose: Dysphagia after chemoradiotherapy is common. The present randomized clinical trial studied the effectiveness of preventative behavioral intervention for dysphagia compared with the 'usual care.' Methods and Materials: A total of 58 head-and-neck cancer patients treated with chemoradiotherapy were randomly assigned to usual care, sham swallowing intervention, or active swallowing exercises (pharyngocise). The intervention arms were treated daily during chemoradiotherapy. The primary outcome measure was muscle size and composition (determined by T{sub 2}-weighted magnetic resonance imaging). The secondary outcomes included functional swallowing ability, dietary intake, chemosensory function, salivation, nutritional status, and the occurrence of dysphagia-related complications. Results: The swallowing musculature (genioglossus, hyoglossuss, and mylohyoid) demonstrated less structural deterioration in the active treatment arm. The functional swallowing, mouth opening, chemosensory acuity, and salivation rate deteriorated less in the pharyngocise group. Conclusion: Patients completing a program of swallowing exercises during cancer treatment demonstrated superior muscle maintenance and functional swallowing ability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Patients' Decision Aid for Older Women With Stage I Breast Cancer Considering Radiotherapy After Lumpectomy

Purpose: To develop a patient decision aid (PtDA) for older women with Stage I, pathologically node negative, estrogen receptor-positive progesterone receptor-positive breast cancer who are considering adjuvant radiotherapy after lumpectomy and to examine its impact on patients' decision making. Methods and Materials: A PtDA was developed and evaluated in three steps according to the Ottawa Decision Support Framework: (1) needs assessment (n = 16); (2) Pilot I to examine PtDA acceptability (n = 12); and (3) Pilot II, a pretest posttest (n = 38) with older women with estrogen receptor-positive progesterone receptor-positive breast cancer after lumpectomy who were receiving adjuvant radiation therapy. Measures included patients' satisfaction with the PtDA, self-reported decisional conflict, level of distress, treatment-related knowledge, and choice predisposition. Results: The PtDA is a booklet that details each adjuvant treatment option's benefits, risks, and side effects tailored to the patient's clinical profile; includes a values clarification exercise; and includes steps to guide patients towards their decision. On the basis of qualitative comments and satisfaction ratings, all women thought that the PtDA was helpful and informative. In comparison with their baseline scores, patients had a statistically significant (p < 0.05) reduction in decisional conflict (adjusted mean difference [AMD], -7.18; 95% confidence interval [CI], -13.50 to 12.59); increased clarity of the benefits and risks (AMD, -10.86; CI, -20.33 to 21.49); and improved general treatment knowledge (AMD, 8.99; CI, 2.88-10.28) after using the PtDA. General trends were also reported in the patients' choice predisposition scores that suggested potential differences in treatment decision after PtDA use. Conclusions: This study provides evidence that this PtDA may be a helpful educational tool for this group of women. The quality of care for older breast cancer patients may be enhanced by the use of a tailored PtDA to help patients be better informed about their treatment options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Associated With Long-Term Dysphagia After Definitive Radiotherapy for Locally Advanced Head-and-Neck Cancer

Purpose: The use of altered fractionation radiotherapy (RT) regimens, as well as concomitant chemotherapy and RT, to intensify therapy for locally advanced head-and-neck cancer can lead to increased rates of long-term dysphagia. Methods and Materials: We identified 122 patients who had undergone definitive RT for locally advanced head-and-neck cancer, after excluding those who had been treated for a second or recurrent head-and-neck primary, had Stage I-II disease, developed locoregional recurrence, had <12 months of follow-up, or had undergone postoperative RT. The patient, tumor, and treatment factors were correlated with a composite of 3 objective endpoints as a surrogate for severe long-term dysphagia: percutaneous endoscopic gastrostomy tube dependence at the last follow-up visit; aspiration on a modified barium swallow study or a clinical diagnosis of aspiration pneumonia; or the presence of a pharyngoesophageal stricture. Results: A composite dysphagia outcome occurred in 38.5% of patients. On univariate analysis, the primary site (p = 0.01), use of concurrent chemotherapy (p = 0.01), RT schedule (p = 0.02), and increasing age (p = 0.04) were significantly associated with development of composite long-term dysphagia. The use of concurrent chemotherapy (p = 0.01), primary site (p = 0.02), and increasing age (p = 0.02) remained significant on multivariate analysis. Conclusion: The addition of concurrent chemotherapy to RT for locally advanced head-and-neck cancer resulted in increased long-term dysphagia. Early intervention using swallowing exercises, avoidance of nothing-by-mouth periods, and the use of intensity-modulated RT to reduce the dose to the uninvolved swallowing structures should be explored further in populations at greater risk of long-term dysphagia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation of Molecular Response as Measured by 18-FDG Positron Emission Tomography With Outcome After Chemoradiotherapy in Patients with Esophageal Carcinoma

Purpose: To determine whether 18-fluorodeoxyglucose positron emission tomography (PET) computed tomography scans predict the pathologic complete response and disease-free and overall survival in patients with esophageal carcinoma undergoing definitive or preoperative chemoradiotherapy. Methods and Materials: The records of patients with esophageal carcinoma presenting for definitive or preoperative treatment and undergoing pre- and post-treatment 18-fluorodeoxyglucose PET-computed tomography scans were retrospectively reviewed. The histologic type, T stage, and nodal status were the variables investigated to determine a relationship with the baseline standardized uptake value (SUV) of the primary tumor at diagnosis. We also attempted to determine whether a relationship exists between the percent decrease in SUV and a pathologic complete response, overall and disease-free survival. Results: A total of 81 patients, 14 women and 67 men, underwent 18-fluorodeoxyglucose PET-computed tomography scanning before treatment and 63 also had post-treatment scans. T stage and tumor location predicted in univariate, but not multivariate, analysis for the initial SUV. Of the patients with a postchemoradiotherapy SUV of <2.5, 66% had tumor in the surgical specimen and 64% of patients had positive lymph nodes at surgery that were not imaged on the postchemoradiotherapy PET scan. A trend existed for post-treatment SUV and the days from radiotherapy to surgery to predict for a pathologic complete response (p = 0.09 and p = 0.08, respectively). The post-treatment SUV predicted for disease-free survival in the definitive chemoradiotherapy group (p = 0.01). Conclusions: A correlation was found between the depth of tumor invasion and the baseline SUV. The post-treatment SUV predicted for disease-free survival in the definitive chemoradiotherapy group. Caution should be exercised in using post-treatment PET scans to determine the necessity for surgical resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multimodal and integrated approach to interrogate human kidney biopsies with rigor and reproducibility: guidelines from the Kidney Precision Medicine Project

Comprehensive and spatially mapped molecular atlases of organs at a cellular level are a critical resource to gain insights into pathogenic mechanisms and personalized therapies for diseases. The Kidney Precision Medicine Project (KPMP) is an endeavor to generate three-dimensional (3-D) molecular atlases of healthy and diseased kidney biopsies by using multiple state-of-the-art omics and imaging technologies across several institutions. Obtaining rigorous and reproducible results from disparate methods and at different sites to interrogate biomolecules at a single-cell level or in 3-D space is a significant challenge that can be a futile exercise if not well controlled. Here we describe a “follow the tissue” pipeline for generating a reliable and authentic single-cell/region 3-D molecular atlas of human adult kidney. Our approach emphasizes quality assurance, quality control, validation, and harmonization across different omics and imaging technologies from sample procurement, processing, storage, shipping to data generation, analysis, and sharing. We established benchmarks for quality control, rigor, reproducibility, and feasibility across multiple technologies through a pilot experiment using common source tissue that was processed and analyzed at different institutions and different technologies. A peer review system was established to critically review quality control measures and the reproducibility of data generated by each technology before their being approved to interrogate clinical biopsy specimens. The process established economizes the use of valuable biopsy tissue for multiomics and imaging analysis with stringent quality control to ensure rigor and reproducibility of results and serves as a model for precision medicine projects across laboratories, institutions and consortia.

59 BASIC BIOLOGICAL SCIENCES↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

Role of IVC Filters in Endovenous Therapy for Deep Venous Thrombosis: The FILTER-PEVI (Filter Implantation to Lower Thromboembolic Risk in Percutaneous Endovenous Intervention) Trial

Objectives: The purpose of this study was to evaluate the necessity of and recommend indications for inferior vena cava (IVC) filter implantation during percutaneous endovenous intervention (PEVI) for deep venous thrombosis (DVT).BackgroundPEVI has emerged as a powerful tool in the management of acute proximal DVT. Instrumentation of extensive fresh thrombus is potentially associated with iatrogenic pulmonary embolism (PE). The true frequency of this complication has not been studied in a randomized fashion. We evaluated IVC filter implantation during PEVI for DVT. Methods: A total of 141 patients with symptomatic proximal DVT undergoing PEVI for symptomatic DVT were randomized to receive an IVC filter (70 patients) or no filter (71 patients; control group). The anticoagulation and PEVI regimen were similar between the two groups. Patients with development of symptoms suggestive of PE underwent objective testing for PE. Results: PE developed in 1 of the 14 symptomatic patients in the filter group and 8 of the 22 patients in the control group (P = 0.048). There was no mortality in any group. Three patients (4.2%) in the control group had transient hemodynamic instability necessitating resuscitory efforts. Predictors of iatrogenic PE were found to be PE at admission; involvement of two or more adjacent venous segments with acute thrombus; inflammatory form of DVT (severe erythema, edema, pain, and induration); and vein diameter of {>=}7 mm with preserved architecture. Conclusions: IVC filter implantation during PEVI reduces the risk of iatrogenic PE by eightfold without a mortality benefit. A selective approach may be exercised in filter implantation during PEVI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-G-BRE-09: Validating FMEA Against Incident Learning Data: A Study in Stereotactic Body Radiation Therapy

Purpose: Though FMEA (Failure Mode and Effects Analysis) is becoming more widely adopted for risk assessment in radiation therapy, to our knowledge it has never been validated against actual incident learning data. The objective of this study was to perform an FMEA analysis of an SBRT (Stereotactic Body Radiation Therapy) treatment planning process and validate this against data recorded within an incident learning system. Methods: FMEA on the SBRT treatment planning process was carried out by a multidisciplinary group including radiation oncologists, medical physicists, and dosimetrists. Potential failure modes were identified through a systematic review of the workflow process. Failure modes were rated for severity, occurrence, and detectability on a scale of 1 to 10 and RPN (Risk Priority Number) was computed. Failure modes were then compared with historical reports identified as relevant to SBRT planning within a departmental incident learning system that had been active for two years. Differences were identified. Results: FMEA identified 63 failure modes. RPN values for the top 25% of failure modes ranged from 60 to 336. Analysis of the incident learning database identified 33 reported near-miss events related to SBRT planning. FMEA failed to anticipate 13 of these events, among which 3 were registered with severity ratings of severe or critical in the incident learning system. Combining both methods yielded a total of 76 failure modes, and when scored for RPN the 13 events missed by FMEA ranked within the middle half of all failure modes. Conclusion: FMEA, though valuable, is subject to certain limitations, among them the limited ability to anticipate all potential errors for a given process. This FMEA exercise failed to identify a significant number of possible errors (17%). Integration of FMEA with retrospective incident data may be able to render an improved overview of risks within a process.

60 APPLIED LIFE SCIENCES↗