Replacing NaI with CdZnTe in Radioxenon Detectors for Nuclear Explosion Monitoring
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Current efforts to correctly categorize natural events from suspected explosion sources with data that is collected by ground- or space-based sensors presents historical challenges that remain unaddressed by the Event Categorization Matrix (ECM) model. Smaller historical events (lower yield explosions) may have data available from fewer measurement techniques than are available today, and therefore, a historical event record can lack a complete set of discriminants. The covariance structures can also differ between such observations of event (source-type) categories. Both obstacles are problematic for the classic ECM model. Our work addresses this gap and presents a Bayesian update to the previous ECM model, termed the Bayesian Event Categorization Matrix model, which can be trained on partial observations and does not rely on a pooled covariance structure. We further augment the ECM model with Bayesian Decision Theory so that false negative or false positive rates of an event categorization can be reduced in an intuitive manner. To demonstrate improved categorization rates for the Bayesian Event Categorization Matrix model, we compare an array of Bayesian and classic models with multiple performance metrics using Monte Carlo experiments. We use both synthetic and real data. Our Bayesian models show consistent gains in overall accuracy and lower false negative rates relative to the classic ECM model. Here, we propose future avenues to improve Bayesian Event Categorization Matrix models’ decision making and predictive capability.
The analysis of seismic data for evidence of possible nuclear explosion testing is a critical global security mission that relies heavily on human expertise to identify and mark seismic signals embedded in background noise. To assist analysts in making these determinations, we adapted two compression distance metrics for use with seismic data. First, we demonstrated that the Normalized Compression Distance (NCD) metric can be adapted for use with waveform data and can identify the arrival times of seismic signals. Then we tested an approximation for the NCD called Sliding Information Distance (SLID), which can be computed much faster than NCD. We assessed the accuracy of the SLID output by comparing it to both the Akaike Information Criterion (AIC) and the judgments of expert seismic analysts. Our results indicate that SLID effectively identifies arrival times and provides analysts with useful information that can aid their analysis process.
This a guide on how to detect and identify explosions from various sources. For example, nuclear explosions produce acoustic, optical, and EMP outputs. Each signal can be buried in noise, but fusing detection statistics from seismic, acoustic, and electromagnetic signals results in clear detection otherwise unobtainable.
SUMMARY An underground nuclear explosion (UNE) couples mechanical energy into crustal rock, which propagates as seismic and acoustic waves. These different physical phenomena transport, by different pathways, to standoff detectors at varying distances. The transport pathways attenuate the original signal but in different ways. Enabled by correct statistical weighting, signal attenuation models can be used to combine these disparate sensor data to estimate the yield of an UNE. Contemporaneous statistical models, used in yield estimation, can be improved with an advanced partition of error for these physical signal propagation models. We present an advanced multivariate approach to error modelling of multiphenomenology physical signatures. In addition to measurement error, our error model represents physical model biases as random with a physics-based covariance structure. To illustrate this proposed framework, we demonstrate the estimation of explosion yield using openly available seismic and acoustic data from chemical single-point explosions.
This project is in support of the Source Physics Experiment (SEP), which aims to develop new seismic source models of explosions. One priority of this program is first principle numerical modeling to validate and extend current empirical models.
This project is in support of the Source Physics Experiment SPE (Snelson et al. 2013), which aims to develop new seismic source models of explosions. One priority of this program is first principle numerical modeling to validate and extend current empirical models.
A series of multi-physics experiments, referred to as Physics Experiment 1 (PE1) is underway at the United States’ Nevada National Security Site (NNSS). The PE1 series includes detonations of three underground chemical explosions in P-tunnel, with fully coupled (PE1 A), partially decoupled (PE1 D L ), and fully decoupled (PE1 B) emplacements. Canisters with gas tracers are imbedded in the explosives, and the tracers are released when the canister is destroyed by the detonation. A dedicated electromagnetic (EM) experiment (EMX) generates well-characterized EM signals at an underground location near the chemical explosive experiments. A series of atmospheric experiments (METEX, REACT, and METREX) release smoke and radioactive tracers around Aqueduct Mesa to test gas transport in complex topography. Each of the chemical explosive experiments includes a network of sensors to record seismic, acoustic, and electromagnetic waves, measurement of atmospheric conditions, and air sample collection for measurement of tracer concentration. EMX records EM signals underground and on the surface of Aqueduct Mesa. METEX, REACT, and METREX include measurement of atmospheric condition, as well as tracking smoke releases. REACT and METREX add low-level radioactive gas tracers to the atmospheric releases.
Not Available
The Comprehensive Nuclear-Test-Ban Treaty bans all nuclear tests and mandates development of verification measures to detect treaty violations. One verification measure is detection of radioactive xenon isotopes produced in the fission of actinides. The International Monitoring System (IMS) currently deploys automated radioxenon systems that can detect four radioxenon isotopes. Radioxenon systems with lower detection limits are currently in development. Historically, the sensitivity of radioxenon systems was measured by the minimum detectable concentration for each isotope. In this paper we analyze the response of radioxenon systems using rigorous metrics in conjunction with hypothetical representative releases indicative of an underground nuclear explosion instead of using only minimum detectable concentrations. Our analyses incorporate the impact of potential spectral interferences on detection limits and the importance of measuring isotopic ratios of the relevant radioxenon isotopes in order to improve discrimination from background sources particularly for low-level releases. To provide a sufficient data set for analysis, hypothetical representative releases are simulated every day from the same location for an entire year. The performance of three types of samplers are evaluated assuming they are located at 15 IMS radionuclide stations in the region of the release point. The performance of two IMS-deployed samplers and a next-generation system is compared with proposed metrics for detection and discrimination using representative releases from the nuclear test site used by the Democratic People’s Republic of Korea.
Design of an efficient monitoring network requires information on the type and size of releases to be detected, the accuracy and reliability of the measuring equipment, and the desired network performance. This work provides a scientific basis for optimizing or minimizing networks of 133 Xe samplers to achieve a desired performance level for different levels of release. The approach of this work varies the density of sampling locations to find optimal location subsets, and to explore the properties of variations of those subsets – how crucial is a specific subset; are substitutions problematic? The choice of possible station locations is arbitrary but constrained to some extent by the location of islands, land masses, difficult topography (mountains, etc.) and the places where infrastructure exists to run and support a sampler. Performance is evaluated using hypothetical releases and atmospheric transport models that cover an entire year.
Abstract Not Provided.
To be presented at the 36th International Test and Evaluation Education Symposium, November 12-16, 2019. https://www.itea.org/event/36th-international-test-and-evaluation-symposium/ https://www.itea.org/guidelines-for-presentations-at-itea-events/
The data sources tend to have the highest quality data and metadata, particularly for more recent data sets. Early data from sources such as IRIS tend to have some metadata issues.
Abstract not provided.
Explore the source record for details and available documents.