Search NASA⌕ Search

SEARCH · Search NASA

Results for “External hazards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multicriterion Benefit Evaluation of Deploying New Battery Technology with Increased Capacity at a Generic Nuclear Power

Nuclear power plant (NPP) safety improvements are routinely made by plant licensees and regulators. Examples of plant improvements include accident-tolerant fuel, diverse and flexible coping strategies, passive cooling systems, and increased battery capacity. A combined use of these plant improvements could lead to plant designs with enhanced resilience, allowing NPPs to better cope with both internal and external hazards and keep the plant operating safely, efficiently, and economically. This paper focuses on increased battery capacity and evaluates the potential costs and benefits of deploying batteries with increased capacities at a generic boiling water reactor (BWR) NPP. A multicriterion benefit evaluation methodology is used for the cost-benefit analysis. Ten alternatives for extending battery capacity are developed, including nine alternatives to provide additional direct-current power and one alternative to provide additional alternating-current power. Potential benefits of reducing plant risk are quantified through incorporating the alternatives into loss-of-offsite-power scenarios of the generic BWR probabilistic risk assessment model. Potential costs of implementing the alternatives are qualitatively discussed and ranked. The alternatives are then compared based on their impacts on plant risk and economics.

99 GENERAL AND MISCELLANEOUS↗

Multicriterion Benefit Evaluation of Deploying New Battery Technology with Increased Capacity at a Generic Nuclear Power Plant

This presentation is prepared for the DOE LWRS RISA Pathway Stakeholder Engagement Meeting on October 13-14, 2021. Nuclear power plant (NPP) safety improvements are routinely made by plant licensees and regulators. Examples of plant improvements include accident-tolerant fuel, diverse and flexible coping strategies, passive cooling systems, and increased battery capacity. A combined use of these plant improvements could lead to plant designs with enhanced resilience, allowing NPPs to better cope with both internal and external hazards and keep the plant operating safely, efficiently, and economically. This presentation focuses on increased battery capacity and evaluates the potential costs and benefits of deploying batteries with increased capacities at a generic boiling water reactor (BWR) NPP. A multicriterion benefit evaluation methodology is used for the cost-benefit analysis. Ten alternatives for extending battery capacity are developed, including eight alternatives to provide additional direct-current power and one alternative to provide additional alternating-current power. Potential benefits of reducing plant risk are quantified through incorporating the alternatives into loss-of-offsite-power scenarios of the generic BWR probabilistic risk assessment model. Potential costs of implementing the alternatives are qualitatively discussed and ranked. The alternatives are then compared based on their impacts on plant risk and economics.

99 GENERAL AND MISCELLANEOUS↗

fmdtools Tutorial: Intro to Resilience Modelling, Simulation, and Visualization in Python With fmdtools

This workshop will cover the basics of using the fmdtools package for the simulation of hazardous scenarios for resilience simulation. The fmdtools simulation package is an open-source python toolkit for simulating the dynamic response of a system to internal and externally-driven hazardous scenarios, including faults and environmental conditions, that can be used to analyze the risks related to these hazards. Prior to the development of fmdtools, researchers had to either adapt an (often limited) propriety toolkit or develop their own design/simulation/analysis codes to develop their models of hazardous events, a significant technical burden to both (1) leveraging resilience modeling methodologies and (2) extending these methodologies with their own contributions. The fmdtools package provides a number of model constructs and simulation and analysis methods to enable the designer to focus to solely on their modeling case-study while still enabling a significant degree of model expressiveness and adaptability via Python-based model definition. This tutorial will present the setup of fmdtools and a high-level overview of its use, as well as some simple examples for understanding how to leverage its modelling, simulation, and analysis capabilities. Familiarity with jupyter notebook and basic python will be assumed.

Daniel Hulse↗

MASTODON: An Open-Source Software for Seismic Analysis and Risk Assessment of Critical Infrastructure

Seismic analysis and risk assessment of safety-critical infrastructure like hospitals, nuclear power plants, dams, and facilities handling radioactive materials involve computationally intensive numerical models and coupled multiphysics scenarios. They are also performed in a strict regulatory environment that requires high software quality assurance standards, and in the case of safety-related nuclear facilities, a conformance to the American Society of Mechanical Engineers Nuclear Quality Assurance (NQA-1) standard. This paper introduces the open-source finite-element software, MASTODON (Multi-hazard Analysis of Stochastic Time-Domain Phenomena), which implements state-of-the-art seismic analysis and risk assessment tools in a quality-controlled environment. MASTODON is built on MOOSE (Multi-physics Object-Oriented Simulation Environment), which is a highly parallelizable, NQA-1 conforming, coupled multiphysics, finite-element framework developed at Idaho National Laboratory. MASTODON is capable of fault rupture and source-to-site wave propagation using the domain reduction method, nonlinear site response, and soil-structure interaction analysis, implicit and explicit time integration, automated stochastic simulations, and seismic probabilistic risk assessment. When coupled with other MOOSE applications, MASTODON can also solve strongly and weakly coupled multiphysics problems. This paper presents a summary of the capabilities of MASTODON and some demonstrative examples.

42 ENGINEERING↗

Development of the Mobile Systems for Conditioning of Disused Sealed Radioactive Sources in Serbia - 20105

Sealed radioactive sources (SRS) are being used worldwide in the field of medicine, agriculture, industry and research. They can be found in mobile as well as stationary devices. SRS contains radioactive material that is (a) permanently sealed in a capsule or (b) closely bounded and in a solid form. The capsule or material of an SRS should be strong enough to maintain leak tightness under the conditions of use and purpose for which the source was designed, also in case of accidents. In this case only emitted radiation is utilized. Firstly, the hazard from external radiation has to be considered, but the possibility of contamination due to fracture of the capsule should not be disregarded. The radioactive sources are composed of the radiating isotope contained in the filling medium, the single or double isotope holder that partially or totally surrounds the filling medium, the outer cover that contains the parts mentioned above and the capsule closed airtightly by welding or using some other method. The capsule must be tested for leakage periodically. If the SRS is no longer needed (e.g. replaced by a different technique) or it becomes useless for the intended application (e.g. the activity becomes too weak, the equipment containing the source works poorly or becomes obsolete, the source is damaged or leaking) it is considered disused. Disused sealed radioactive sources (DSRS) are typically conditioned and disposed if a facility is available. If the disposal option is not available, conditioned DSRS should be stored under proper conditions. In some cases, the radionuclide(s) in DSRS can be recovered/recycled or the DSRS can be repurposed for other applications. Conditioning of DSRS ensures containment of the radioactive material, provides confinement for leaking sources, provides sufficient radiation shielding, reduces storage/disposal volume by allowing consolidation of multiple sources into a single storage/disposal container, facilitates transport operations and contributes to safety and security as well. Typically, conditioning technologies are deployed either as permanently installed stationary systems in centralized or mobile on-site waste processing facilities, or in a mobile configuration. Centralized stationary facilities provide a single processing location for multiple users that requires transport of the waste to the facility. On the other hand, mobile systems may be provided for the selection and application of the optimum technology for a specific waste stream (such as DSRS) by bringing the process to the point where the waste is generated. In addition, mobile systems could offer additional flexibility by sharing equipment among multiple waste generating sites for processing campaigns that vary in duration, from very short periods to several years. The term 'mobile processing system' refers to any radioactive waste processing system or component which is designed to be transportable and which is not considered permanently installed. Two mobile system for conditioning of disused sealed radioactive sources are developed in the Public Company Nuclear Facilities of Serbia. Development of these mobile systems was supported by SRB9005 national project via Technical Cooperation of the IAEA. The first mobile system, built inside the 20 feet ISO container, will be used for conditioning of DSRS category 3 to 5. The second mobile system, built inside the 7 m long vehicle (Iveco Daily Van), will be used for dismantling of ionizing smoke detectors mostly with Am-241 sources. Designs of the mobile systems were defined in cooperation with two companies from Belgium (Belgoprocess and Leniko) and a Croatian company Ekoteh as well as with the support of the IAEA experts. The generic safety assessment and operational procedures for the mobile systems are developed. Based on safety assessment the acceptance criteria and operational limits and conditions are established. Operational procedures include: (a) equipment and material requirements, (b) assembling procedure of the mobile unit, (c) procedure for acceptance of devices for dismantling and conditioning, (d) dismantling procedure for devices to recover the DSRS, (e) characterization of DSRS, (f) encapsulation procedure of DSRS, (g) disassembling procedure of the mobile unit, and (h) keeping records, identification and traceability. In addition, radiation safety, health safety, security and emergency preparedness plans are prepared. The generic safety assessment and operational procedures could be updated with site specific requirements, DSRS inventory, and different needs for future customers. Developed mobile systems could be used in all situations when it is feasible to perform conditioning of DSRS on the spot in the county and worldwide. Development of these mobile units was just the first step to create the Reference Center for Radioactive Waste Treatment and Disused Radioactive Sources Conditioning for Small Facilities which can become a regional training center in the future, and/or as a tool for comprehensive national search and secure programmes. In the next phases development of e-learning platforms and blended learning packages as well as application for the IAEA Qualified Technical Centre (QTC) for the management of DSRS is foreseen. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tritiated Sulfur Hexafluoride Disposition Strategies

Tritium (T 2 ) is a radioactive isotope of hydrogen that is produced in nuclear fission reactions and is often used in nuclear fusion reactions and accelerator-based applications for medical isotope production. As a hydrogen isotope, tritium can readily bind to hydroxyl radicals (OH), forming tritiated water (HTO or T 2 0), and to carbon atoms. Tritium decays to helium-3 ( 3 He) via beta-decay with max decay energy of 18.6 keV. While it is not an external radiation hazard, it can be an internal radiation hazard if tritium is inhaled, ingested, or absorbed through the skin. In applications where tritium is handled, tritium confinement is performed using different barriers to minimize releases to the environment. For gaseous (elemental), liquid (oxide), and metal (hydride) tritium, process piping and components provide the primary confinement function. Secondary tritium confinement is typically provided by inert (i.e. non-flammable gases such as nitrogen, argon, or helium) gloveboxes which are connected to a tritium stripper system. Primary tritium confinement barriers typically produce low volumes of high tritium concentrations of tritiated methane from carbon in steels or organic materials along with tritiated water/tritium oxide (e.g. HTO) and tritiated ammonia from reactions with oxygen and nitrogen. Tritium escaping primary confinement into secondary confinement atmospheres (e.g. gloveboxes) produce higher volumes of lower activity contamination than found in process piping. Tritium contamination also occurs by leaks or tritium permeation/diffusion through confinement materials. Tritium from inside primary confinement barriers will diffuse or leak out of the primary confinement barrier and usually into the air, if the system is inside an air hood or ventilated hot cell, or into the secondary confinement (e.g. glovebox) atmosphere which is either exhausted or stripped based on the function of the secondary confinement (glovebox) system. Accelerator based processes for medical isotope production represent an atypical tritium contamination challenge. In medical isotope production, deuterium supply gas is ionized and accelerated to a tritium gas target to produce neutrons that are then used to produce the medical isotopes through additional nuclear fission reactions. To create large voltage differentials for accelerator operations, an electrical insulation medium is needed to prevent or rapidly quench electric discharges. A common electrical insulation medium utilized in accelerator applications is sulfur hexafluoride (SF 6 ) gas. SF 6 has a high dielectric strength and allows for the construction of smaller accelerator systems compared to other electrical insulation mediums such as air or dry nitrogen. Due to tritium permeation/diffusion through accelerator process and confinement materials, there is the possibility that tritium can contaminate the electrical insulation medium of the accelerator. Tritium contaminated SF 6 creates a material without any obvious processes for managing the contamination, reuse, or disposal of the used SF 6 . This document will discuss possible management strategies for tritium contaminated SF 6 for accelerator-based processes for Molybdenum-99 (Mo-99) production.

07 ISOTOPE AND RADIATION SOURCES↗

Direct-Link Prehensor

Operator-powered mechanical hand gives protection, dexterity, and proximity to work. Prehensor has ring finger, index finger, and thumb, mounted on supporting frame. Ring and index fingers consist of three jointed links each, and thumb consists of two jointed links. Thumb positioned opposite fingers in anthropomorphic arrangement. Palm assistor (disk projecting from support frame) helps mechanical fingers to hold objects. Shroud encloses operator's hand, protecting it from vacuum, high pressure, or hazardous materials. External mechanical fingers made of materials compatible with external environment.

Jameson, John W.↗

Design Safety Used in NASA's Human-rated Primary Lithium Batteries

Single cell tests were benign for external short, inadvertent charge and overdischarge into reversal up to 4.5 A. At lower current loads cells die (may be due to excessive dendrite formation) benignly. String level external short circuits lead to an unbalanced overdischarge, with one cell going into reversal. The result is catastrophic violent venting. Unbalanced string overdischarges at different currents causes catastrophic violent venting also. Heat-to-vent is very dramatic displaying violent venting Simulated internal short is also catastrophic and displays violent venting. Battery is not UL-rated; hence does not have dual-fault tolerance or tolerance to inherent cell tolerance to failures Battery Design for NASA JSC's human-rated application for use on ISS was changed to include two bypass diodes per cell to provide for two-failure tolerance to overdischarge into reversal (and external short) hazards.

Jeevarajan, J.↗

Simulation of external and internal electrostatic discharges at the spacecraft system test level

Environmental test activities concerned with space plasma-caused charging and discharing phenomena are discussed. It is pointed out that the origin of such an electrostatic discharge (ESD) is charging of spacecraft dielectrics by an energetic plasma in geosynchronous orbit, Jupiter's magnetosphere, or other similar space environments. In dealing with environmental testing problems, it is necessary to define the location and magnitude of any ESD's in preparation for a subsequent simulation of the given conditions. Questions of external and internal charging are discussed separately. The environmental hazard from an external discharge can be assessed by viewing the dielectric surface as one side of a parallel plate capacitor. In the case of internal charging, the level of environmental concern depends on the higher energy spectrum of the ambient electrons.

Whittlesey, A.↗

Integrated Safety Analysis Teams

Today's complex systems require understanding beyond one person s capability to comprehend. Each system requires a team to divide the system into understandable subsystems which can then be analyzed with an Integrated Hazard Analysis. The team must have both specific experiences and diversity of experience. Safety experience and system understanding are not always manifested in one individual. Group dynamics make the difference between success and failure as well as the difference between a difficult task and a rewarding experience. There are examples in the news which demonstrate the need to connect the pieces of a system into a complete picture. The Columbia disaster is now a standard example of a low consequence hazard in one part of the system; the External Tank is a catastrophic hazard cause for a companion subsystem, the Space Shuttle Orbiter. The interaction between the hardware, the manufacturing process, the handling, and the operations contributed to the problem. Each of these had analysis performed, but who constituted the team which integrated this analysis together? This paper will explore some of the methods used for dividing up a complex system; and how one integration team has analyzed the parts. How this analysis has been documented in one particular launch space vehicle case will also be discussed.

Wetherholt, Jonathan C.↗

Vertical Field of View Reference Point Study for Flight Path Control and Hazard Avoidance

Researchers within the eXternal Visibility System (XVS) element of the High-Speed Research (HSR) program developed and evaluated display concepts that will provide the flight crew of the proposed High-Speed Civil Transport (HSCT) with integrated imagery and symbology to permit path control and hazard avoidance functions while maintaining required situation awareness. The challenge of the XVS program is to develop concepts that would permit a no-nose-droop configuration of an HSCT and expanded low visibility HSCT operational capabilities. This study was one of a series of experiments exploring the 'design space' restrictions for physical placement of an XVS display. The primary experimental issues here was 'conformality' of the forward display vertical position with respect to the side window in simulated flight. 'Conformality' refers to the case such that the horizon and objects appear in the same relative positions when viewed through the forward windows or display and the side windows. This study quantified the effects of visual conformality on pilot flight path control and hazard avoidance performance. Here, conformality related to the positioning and relationship of the artificial horizon line and associated symbology presented on the forward display and the horizon and associated ground, horizon, and sky textures as they would appear in the real view through a window presented in the side window display. No significant performance consequences were found for the non-conformal conditions.

Comstock, J. Raymond, Jr.↗

Establishing Hazardous Gas Launch Commit Criteria for the Space Shuttle External Tank Intertank Compartment

Until recently, the simultaneous detection and evaluation of multiple Space Transportation System (STS) element compartments for propellant leakage was not possible during the External Tank (ET) pre-pressurization (pre-press) phase of propellant loading; late in the loading sequence (T-3 min to T-0). There exist launch commit criteria (LCCS) designed to protect against leaks resulting in flammable mixtures in the intertank during the functional life of the ET; start of propellant loading through ET-Orbiter separation. However thus far, leak protection had relied on the premise that if a propellant supply system leak were to exist, it would be a leak of fixed area present at the start of propellant loading (dumb leak mode) and such a leak could be detected earlier in the loading sequence than the pre-press phase. No measures had ever been implemented which would protect against leaks potentially developing late in the loading sequence (smart leak mode), The STS community had baselined this situation as an accepted risk their decision supported by exhaustive hardware acceptance criteria and a history of many successful launches. With the recent development of improvements to the hazardous gas detection system (HGDS), an opportunity arose to monitor the intertank compartment for hazardous gas concentrations beyond the T-3 minute mark. In this timeframe the propellant supply system is pressurized for flight and protection was sought against potential leaks generated by this pressurization process. The challenge at hand was to develop LCCs in this timeframe that were not too conservative to unnecessarily prohibit a launch, yet not too liberal to endanger crew safety and mission success. Since essentially no measurement history existed in this timeframe, the LCCs would have to rely on analysis alone. At NASA's direction, Lockheed Martin Michoud Space Systems (LMMSS) developed requirements that would protect against a smart leak during pre-press. A smart leak protection strategy is noteworthy from an STS main propulsion system (NWS) community perspective. This paper presents the resultant requirements as well as the technical and program issues involved with establishing hazardous gas LCCs for the ET intertank compartment.

Baran, Adam J.↗

Towards Computational Functional Hazard Assessment (CFHA): A Gap Analysis and Concept for Emerging Aviation Systems

Given the current evolution of the National Airspace and future trajectory towards novel and evolving operations with varying levels of autonomy, complexity, and acceptable risk, there is an opportunity to support safety assurance by extending existing methodologies, such as Functional Hazard Assessment (FHA). In response to challenges in performing FHA for novel aviation concepts, we propose a concept for Computational Functional Hazard Assessment (CFHA), which provides processes, methods, and tools for incorporating external data to facilitate further exploration of the hazard space iterativelty throughout the design process. The core components of CFHA involve knowledge capture from historical and operational data, functional architecture specification via a formal modeling language, and simulation for hazardous scenario analysis. Through this concept, we aim to adapt conventional safety assessment to address the increasingly complex hazard space generated from emerging operations.

Seydou Mbaye↗

Towards Functional Hazard Assessment (CFHA): A Gap Analysis and Concept for Emerging Aviation Systems

Given the current evolution of the National Airspace and future trajectory towards novel and evolving operations with varying levels of autonomy, complexity, and acceptable risk, there is an opportunity to support safety assurance by extending existing methodologies, such as Functional Hazard Assessment (FHA). In response to challenges in performing FHA for novel aviation concepts, we propose a concept for Computational Functional Hazard Assessment (CFHA), which provides processes, methods, and tools for incorporating external data to facilitate further exploration of the hazard space iterativelty throughout the design process. The core components of CFHA involve knowledge capture from historical and operational data, functional architecture specification via a formal modeling language, and simulation for hazardous scenario analysis. Through this concept, we aim to adapt conventional safety assessment to address the increasingly complex hazard space generated from emerging operations.

Seydou Mbaye↗

Loss of Control Prevention and Recovery: Onboard Guidance, Control, and Systems Technologies

Loss of control (LOC) is one of the largest contributors to fatal aircraft accidents worldwide. LOC accidents are complex in that they can result from numerous causal and contributing factors acting alone or (more often) in combination. These LOC hazards include vehicle impairment conditions, external disturbances; vehicle upset conditions, and inappropriate crew actions or responses. Hence, there is no single intervention strategy to prevent these accidents. NASA previously defined a comprehensive research and technology development approach for reducing LOC accidents and an associated integrated system concept. Onboard technologies for improved situation awareness, guidance, and control for LOC prevention and recovery are needed as part of this approach. Such systems should include: LOC hazards effects detection and mitigation; upset detection, prevention and recovery; and mitigation of combined hazards. NASA is conducting research in each of these areas. This paper provides an overview of this research, including the near-term LOC focus and associated analysis, as well as preliminary flight system architecture.

Belcastro, Christine M.↗

Effectiveness evaluation of STOL transport operations

A short-takeoff and landing (STOL) systems simulation model has been developed and implemented in a computer code (known as STOL OPS) which permits evaluation of the operation of a STOL aircraft and its avionics in a commercial airline operating environment. STOL OPS concentrated on the avionics functions of navigation, guidance, control, communication, hazard aviodance, and systems management. External world factors influencing the operation of the STOL aircraft include each airport and its geometry, air traffic at each airport, air traffic control equipment and procedures, weather (including winds and visibility), and the flight path between each airport served by the route. The development of the STOL OPS program provides NASA a set of computer programs which can be used for detailed analysis of a STOL aircraft and its avionics and permit establishment of system requirements as a function of airline mission performance goals.

Hitt, E. F.↗

Annual report to the NASA Administrator by the Aerospace Safety Advisory Panel. Part 2: Space shuttle program. Section 1: Observations and conclusions

The NASA and contractor management systems, including policies, practices, and procedures for the development of critical systems, subsystems and integration of the program elements, were investigated. The technical development status of critical systems, subsystems, and interfaces is presented. Space shuttle elements were qualified as to potential risks and hazards. The elements included the orbiter, external tanks, main engine, solid rocket boosters, and the ground support facilities.

Source record↗

Operability of Space Station Freedom's meteoroid/debris protection system

The design of Space Station Freedom's external structure must not only protect the spacecraft from the hazardous environment, but also must be compatible with the extra vehicular activity system for assembly and maintenance. The external procedures for module support are utility connections, external orbital replaceable unit changeout, and maintenance of the meteoroid/debris shields and multilayer insulation. All of these interfaces require proper man-machine engineering to be compatible with the extra vehicular activity and manipulator systems. This paper discusses design solutions, including those provided for human interface, to the Space Station Freedom meteoroid/debris protection system. The system advantages and current access capabilities are illustrated through analysis of its configuration over the Space Station Freedom resource nodes and common modules, with emphasis on the cylindrical sections and endcones.

Kahl, Maggie S.↗