Search NASA⌕ Search

SEARCH · Search NASA

Results for “Extraction chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Rapid Method for Quantification OF 242Pu in Urine Using Extraction Chromatography and ICP-MS

Occupational exposure to plutonium is generally monitored through analysis of urine samples. Typically, plutonium is separated from the sample and other actinides, and the concentration is determined using alpha spectroscopy. Current methods for separations and analysis are lengthy and require long count times. A new method for monitoring occupational exposure levels of plutonium has been developed, which requires fewer steps and overall less time than the alpha spectroscopy method. In this method, the urine is acidified, and a 239 Pu internal standard is added. The urine is digested in a microwave oven, and plutonium is separated using an Eichrom TRU Resin column. The plutonium is eluted, and the eluant is injected directly into the Inductively Coupled Plasma–Mass Spectrometer (ICP-MS). Compared to a direct “dilute and shoot” method, a 30-fold improvement in sensitivity is achieved. This method was validated by analyzing several batches of spiked samples. Based on these analyses, a combined standard uncertainty plot, which relates uncertainty to concentration, was produced. As a result, the MDA 95 was calculated to be 7.0 × 10 –7 μg L –1 , and the Lc95 was calculated to be 3.5 × 10 –7 μg L –1 for this method.

61 RADIATION PROTECTION AND DOSIMETRY↗

Separation of actinides using capillary extraction chromatography-inductively coupled plasma mass spectrometry

Trace levels of actinides have been separated on extraction chromatography columns. Detection of the actinides was achieved using an inductively coupled plasma mass spectrometer (ICP-MS), which was coupled with the extraction chromatography system. In this study we compare 30 cm long, 4.6 mm ID columns to capillary columns (750 {micro}m ID) with lengths from 30 cm up to 150 cm. The columns that were tested were packed with TRU resin. We were able to separate a mixture of five actinides ({sup 232}Th, {sup 238}U, {sup 237}Np, {sup 239}pU, {sup 241}Am). This work has application to rapid bioassay as well as for automated separations of actinide materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studies of Flerovium and Element 115 Homologs with Macrocyclic Extractants

Study of the chemistry of the heaviest elements, Z ≥ 104, poses a unique challenge due to their low production cross-sections and short half-lives. Chemistry also must be studied on the one-atom-at-a-time scale, requiring automated, fast, and very efficient chemical schemes. Recent studies of the chemical behavior of copernicium (Cn, element 112) and flerovium (Fl, element 114) together with the discovery of isotopes of these elements with half-lives suitable for chemical studies have spurred a renewed interest in the development of rapid systems designed to study the chemical properties of elements with Z ≥ 114. This dissertation explores both extraction chromatography and solvent extraction as methods for development of a rapid chemical separation scheme for the homologs of flerovium (Pb, Sn, Hg) and element 115 (Bi, Sb), with the goal of developing a chemical scheme that, in the future, can be applied to on-line chemistry of both Fl and element 115. Carrier-free radionuclides, used in these studies, of the homologs of Fl and element 115 were obtained by proton activation of high-purity metal foils at the Lawrence Livermore National Laboratory (LLNL) Center for Accelerator Mass Spectrometry (CAMS): nat In(p,n) 113 Sn, nat Sn(p,n) 124 Sb, and Au(p,n) 197m,g Hg. The carrier-free activity was separated from the foils by novel separation schemes based on ion exchange and extraction chromatography techniques. Carrier-free Pb and Bi isotopes were obtained from development of a novel generator based on cation exchange chromatography using the 232 U parent to generate 212 Pb and 212 Bi. Macrocyclic extractants, specifically crown ethers and their derivatives, were chosen for these studies; crown ethers show high selectivity for metal ions. Finally. a potential chemical system for Fl was established based on the Eichrom Pb resin, and insight to an improved system based on thiacrown ethers is presented.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Extraction Chromatographic Methods in the Sample Preparation Sequence for Thermal Ionization Mass Spectrometric Analysis of Plutonium Isotopes

A sample preparation sequence for actinide isotopic analysis by TIMS is described that includes column-based extraction chromatography as the first separation step, followed by anion exchange column separations. The sequence is designed to include a wet ashing step after the extraction chromatography to prevent any leached extractant or oxalic acid eluent reagents from interfering with subsequent separations, source preparation, or TIMS ionization. TEVA-resin and DGA-resin materials, containing extractants that consist only of C, N, O, and H atoms, were investigated for isolation of plutonium. Radiotracer level studies confirmed expected high yields from column-based separation procedures. Femtogram-level studies were carried out with TIMS detection, using multiple isotopic spikes through the separation sequence. Pu recoveries were 87% and 86% for TEVA- and DGA-resins separations respectively. The Pu recoveries from 400 {mu}L anion-exchange column separations were 89% and 93% for trial sequences incorporating TEVA and DGA-resin. Thus, a prior extraction chromatography step in the sequence did not interfere with the subsequent anion exchange separation when a simple wet ash step was carried out in between these column separations. The average measurement efficiency, for Pu, encompassing the chemical separation recoveries and the TIMS ionization efficiency, was 2.73 {+-} 0.77% (2-sigma) for the DGA-resin trials and 2.67 {+-} 0.54% for the TEVA-resin trials, compared to 3.41% and 2.37% (average 2.89%) for two spikes in the experimental set. These compare with an average measurement efficiency of 2.78 {+-} 1.70%, n = 33 from process benchmark analyses using Pu spikes processed through a sequence of oxalate precipitation, wet ash, iron hydroxide precipitation, and anion exchange column separations. We conclude that extraction chromatography can be a viable separation procedure as part of a multistep sequence for TIMS sample preparation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Instrument for Solvent Extraction and Analysis (ISEE) of Organics from Regolith Simulant Using Supercritical Fluid Extraction and Chromatography

ISEE is an instrument with the potential to perform extractions from regolith found on the surface of asteroids and planets, followed by characterization and quantitation of the extracts using supercritical fluid extraction (SFE) and chromatography (SFC). SFE is a developed technique proven to extract a wide range of organic compounds. SFC is similar to High Performance Liquid Chromatography (HPLC) but has the advantage of performing chiral separations without needing to derivatize the chiral compounds. CO2 will be the solvent for both stages as it is readily available in the Mars atmosphere. ISEE will capture CO2 from the environment, and use it for SFE and SFC. If successful, this would allow ISEE to perform analysis of organic compounds without using consumables. This paper will present results on a preliminary, proof-of-principle effort to use SFE and SFC to extract and analyze lunar regolith simulant spiked with organic compounds representing a range of organics that ISEE would expect to characterize. An optimization of variables for the extraction of the organics from the spiked regolith was successfully developed, using 138 bar pressure and 40 C temperature. The extraction flow rate was optimized at 2% SLPM with 30% methanol modifier. The extractions were successful with a value of 77.3+/- 0.9% of organics extracted. However, the recovery of organics after the extraction was very low with only 48.5+/-14.2%. Moreover, three columns were selected to analyze multiple samples at a time; two of them are Viridis HSS C18 SB and Torus DIOL, and the third column, specific for chiral separations, has not yet been selected yet.

Franco, Carolina↗

Mo-99/Tc-99m Separation: An Assessment of Technical Options

Several strategies for the effective separation of 99mTc from 99Mo have been developed and validated. Due to the success of column chromatographic separation using acidic alumina coupled with high specific activity fission 99Mo (F 99Mo) for production of 99Mo/99mTc generators, however, most technologies until recently have generated little interest. The reduced availability of F 99Mo and consequently the shortage of 99Mo/99mTc column generators in the recent past have resurrected interest in the production of 99Mo as well as 99mTc by alternate routes. Most of these alternative production processes require separation techniques capable of providing clinical grade 99mTc from low specific activity 99Mo or irradiated Mo targets. For this reason there has been renewed interest in alternate separation routes. This paper reviews the reported separation technologies which include column chromatography, solvent extraction, sublimation and gel systems that have been traditionally used for the fabrication of 99Mo/99mTc generator systems. The comparative advantage, disadvantage, and technical challenges toward adapting the emerging requirements are discussed. New developments such as solid-phase column extraction, electrochemical separation, extraction chromatography, supported liquid membrane (SLM) and thermochromatographic techniques are also being evaluated for their potential application in the changed scenario of providing 99mTc from alternate routes. Based on the analysis provided in this review, it appears that some proven separation technologies can be quickly resurrected for the separation of clinical grade 99mTc from macroscopic levels of reactor or cyclotron irradiated molybdenum targets. Furthermore, emerging technologies can be developed further to respond to the expected changing modes of 99mTc production.

nuclear medicine↗

Method for producing thorium-226

Disclosed herein are embodiments of a method for producing thorium-226. The method comprises separating thorium-226 from uranium-230 to produce a solution of thorium-226 in a solvent, such as a chelating buffer, suitable for direct labeling by a chelate. The thorium-226 may be separated from the uranium-230 using extraction chromatography. The extraction may be repeated multiple times as additional thorium-226 is produced by uranium-230 decay.

07 ISOTOPE AND RADIATION SOURCES↗

Calculation of Transactinide Homolog Isotope Production Reactions Possible with the Center for Accelerator Mass Spectrometry (CAMS) at Lawrence Livermore National Laboratory

The LLNL heavy element group has been investigating the chemical properties of the heaviest elements over the past several years. The properties of the transactinides (elements with Z > 103) are often unknown due to their low production rates and short half-lives, which require lengthy cyclotron irradiations in order to make enough atoms for statistically significant evaluations of their chemistry. In addition, automated chemical methods are often required to perform consistent and rapid chemical separations on the order of minutes for the duration of the experiment, which can last from weeks to months. Separation methods can include extraction chromatography, liquid-liquid extraction, or gas-phase chromatography. Before a lengthy transactinide experiment can be performed at an accelerator, a large amount of preparatory work must be done both to ensure the successful application of the chosen chemical system to the transactinide chemistry problem being addressed, and to evaluate the behavior of the lighter elemental homologs in the same chemical system. Since transactinide chemistry is literally performed on one single atom, its chemical properties cannot be determined from bulk chemical matrices, but instead must be inferred from the behavior of the lighter elements that occur in its chemical group and in those of its neighboring elements. By first studying the lighter group homologs in a particular chemical system, when the same system is applied to the transactinide element under investigation, its decay properties can be directly compared to those of the homologues, thereby allowing an inference of its own chemistry. The Center for Accelerator Mass Spectrometry (CAMS) at Lawrence Livermore National Laboratory (LLNL) includes a 1 MV Tandem accelerator, capable of accelerating light ions such as protons to energies of roughly 15 MeV. By using the CAMS beamline, tracers of transactinide homolog elements can be produced both for development of chemical systems and for evaluation of homolog chemical properties. CAMS also offers an environment for testing these systems 'online' by incorporating automated chemical systems into the beamline so that tracers can be created, transported, and chemically separated all on the shorter timescales required for transactinide experiments. Even though CAMS is limited in the types and energies of ions they can accelerate, there are still a wide variety of reactions that can be performed there with commercially available target materials. The half-lives of these isotopes vary over a range that could be used for both online chemistry (where shorter half-lives are required) and benchtop tracers studies (where longer lived isotopes are preferred). In this document, they present a summary of tracer production reactions that could be performed at CAMS, specifically for online, automated chemical studies. They are from chemical groups four through seven, 13, and 14, which would be appropriate for studies of elements 104-107, 113, and 114. Reactions were selected that had (a) commercially available target material, (b) half-lives long enough for transport from a target chamber to an automated chemistry system, and (c) cross-sections at CAMS available projectile energies that were large enough to produce enough atoms to result in a statistically relevant signal after losses for transport and chemistry were considered. In addition, the resulting product atoms had to decay with an observable gamma-ray using standard Ge gamma-ray detectors. The table includes calculations performed for both metal targets and their corresponding oxides.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Separation and determination of ultratrace rhenium quantities in molybdenum matrix

The production of very pure molybdenum, free of Re even at ultratrace levels, is extremely important in meeting target purity specifications during the production of 99 Mo for medical applications. Here we propose two methods for separating ultratrace levels of Re from a bulk Mo matrix using either solvent extraction or extraction chromatography, combined with inductively coupled plasma quadrupole mass spectrometry (ICP-MS) detection. Re is extracted (D > 70) from solutions in sulfuric acid as a complex with tri-n-butyl phosphate. Scrubbing and washing steps result in total decontamination factors for Mo up to 1,700 for solvent extraction and 3,500 for extraction chromatography. Re is stripped into a 3 M NH 4 OH matrix and analyzed by ICP-MS. Detection (L D ) and quantification (L Q ) limits were optimized by matrix-matching to allow detection of Re in strip solutions at levels of L D = 0.1 ng Re/g-Mo and L Q = 0.3 ng Re/g-Mo in Mo powder samples. By employing these two extraction methods, excellent recoveries of Re from bulk Mo are achieved, and the L Q is improved by a factor of 5 x 10 4 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of SR/ TEVA/ TRU triple stack for separation of activation products

A rapid method to separate Ta, Po, Au, Pt, and W from a sample containing mixed fission and activation products was developed using three commercially available extraction chromatography resins stacked in series. When the separation was tested using all the target activation products, even those with short half-lives were measurable. Finally, combining multiple extraction chromatography resin cartridges in tandem allows for multiple short-lived activation products to be separated from one sample addition without the complication of multiple steps.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The Use of Isotope Dilution Alpha Spectrometry and Liquid Scintillation Counting to Determine Radionuclides in Environmental Samples

In Albania in recent years it has been of increasing interest to determine various pollutants in the environment and their possible effects on human health. The radiochemical procedure used to identify Pu, Am, U, Th, and Sr radioisotopes in soil, sediment, water, coal, and milk samples is described. The analysis is carried out in the presence of respective tracer solutions and combines the procedure for Pu analysis based on anion exchange, the selective method for Sr isolation based on extraction chromatography using Sr-Spec resin, and the application of the TRU-Spec column for separation of Am fraction. An acid digestion method has been applied for the decomposition of samples. The radiochemical procedure involves the separation of Pu from Th, Am, and Sr by anion exchange, followed by the preconcentration of Am and Sr by coprecipitation with calcium oxalate. Am is separated from Sr by extraction chromatography. Uranium is separated from the bulk elements by liquid-liquid extraction using UTEVA registered resin. Thin sources for alpha spectrometric measurements are prepared by microprecipitation with NdF3. Two International Atomic Energy Agency reference materials were analyzed in parallel with the samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The production and separation of 161 Tb with high specific activity at the University of Utah

Targeted radiotherapy (TRT) is an increasingly prominent area of research in nuclear medicine, particularly in the context of treating cancerous tumors. One radionuclide of considerable interest for TRT is terbium-161 (t 1/2 = 6.95 days), which undergoes beta emission and shares similar decay properties as 177 Lu (FDA-approved as LUTATHERA® and PLUVICTO®). Besides beta emission, 161 Tb also emits a significant number of conversion and Auger electrons further enhancing its therapeutic potential. Terbium-161 can be produced using nuclear reactors through an indirect neutron capture reaction, $^{160}_{64}$Gd(n,γ) $^{161}_{64}$Gd → (3.7 min, β – ) $^{161}_{65}$Tb, from 160 Gd targets. However, a key challenge in utilizing 161 Tb for TRT lies in effectively separating target and product materials to attain high specific activity for radiolabeling. Here, we detail the production of no-carrier added 161 Tb using low flux research reactors (mean thermal (< 0.625 eV) neutron flux: 1.356 ×10 12 n • cm –2 • s –1 ) like the University of Utah TRIGA Reactor, using enriched 160 Gd 2 O 3 targets (1.5 ± 0.3 µCi of 161 Tb per mg of 160 Gd target per hour of irradiation). We also developed a separation technique based on cation exchange and extraction chromatography, suitable for mCi level irradiations with targets exceeding 200 milligrams. In a simulated full-scale irradiation, 161 Tb was successfully isolated from large mass targets using cation exchange (AG 50W-X8, with 2-hydroxyisobutyric acid at 70 mM, pH 4.75) and extraction chromatography (LN Resin, 0.5 – 0.75 M HNO 3 ) methods. Here, this resulted in high apparent molar activities of [ 161 Tb]Tb-DOTA (113 ± 3 MBq/nmol), demonstrating high purity 161 Tb relevant for potential future preclinical applications.

161Tb↗

“Age” Determination of Irradiated Materials Utilizing Inductively Coupled Plasma Mass Spectrometric (ICP-MS) Detection

A gas pressurized extraction chromatography (GPEC) system has been developed to perform elemental separations on radioactive samples to determine total and isotopic compositions of Cs and Ba from an irradiated salt sample, fuel sample and two sealed radiation sources. The separation is necessary to remove isobaric interferences in the determination of 137Cs, 135Cs, 137Ba, 135Ba, which are used to determine the age of a sample from radioactive decay or purification. The micro-column extraction chromatography system employs compressed nitrogen to move liquid through the system, compared to gravity or pumped liquids that are typically used for separations. The use of compressed gas allows for accurate and precise recovery of all liquids put into the chromatography system, enabling very accurate dilutions. The use of a small analytical column permits the use of very small amounts of liquids to be used. As a benefit, the amount of radiological waste that is generated in the separation process is minimized. For this work, a commercially available Sr-Resin™ was used to perform the separation for the above mentioned analytes. The column consists of a 7 inch piece of 1/16 in. O.D. x 0.030 in I.D. Teflon™ tubing having an internal volume of 81 µL. To this column, 49 mg of resin was added. The columns are re-usable after regeneration with 3 M HNO3. All samples were separated using batch collection, although real time analysis is possible with the current experimental design. A 1 % acetic acid solution was determined to be the best extractant for Ba. A flow rate of 0.1 mL/min was determined to be optimal for the separation of Ba. Complete recovery of the Cs and Ba was achieved, within the systematic error of the experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Separation of gold from irradiated actinide material utilizing a 2- thenoyltrifluoroacetone extraction resin

Post-detonation nuclear forensics capabilities depend on the ability to rapidly isolate radionuclides to improve measurement quality. In this work an extraction chromatography resin was developed utilizing the extractants thenoyltrifluoroacetone and 1-octanol supported on Eichrom prefilter resin. Here the resin was tested in nitric and hydrochloric acid matrices. In nitric acid matrices the resin is able to extract zirconium, while in hydrochloric acid matrices it is possible to extract iron and gallium. In all acid conditions tested gold is retained but can be removed from the column with a 10% thiourea rinse.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗