Search NASA⌕ Search

SEARCH · Search NASA

Results for “Extreme cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ross 19B: An Extremely Cold Companion Discovered via the Backyard Worlds: Planet 9 Citizen Science Project

Through the Backyard Worlds: Planet 9 citizen science project, we have identified a wide-separation (∼10', ∼9900 au projected) substellar companion to the nearby (∼17.5 pc), mid-M dwarf Ross 19. We have developed a new formalism for determining chance alignment probabilities based on the BANYAN Σ tool, and find a 100% probability that this is a physically associated pair. Through a detailed examination of Ross 19A, we find that the system is metal-poor ([Fe/H] = −0.40 ± 0.12) with an age of 7.2 (+3.8, -3.6) Gyr. Combining new and existing photometry and astrometry, we find that Ross 19B is one of the coldest known wide-separation companions, with a spectral type on the T/Y boundary, an effective temperature of 500 (+115, -100) K, and a mass in the range 15–40 M(Jup). This new, extremely cold benchmark companion is a compelling target for detailed characterization with future spectroscopic observations using facilities such as the Hubble Space Telescope or James Webb Space Telescope.

Adam C. Schneider↗

Compression Strength of Sulfur Concrete Subjected to Extreme Cold

Sulfur concrete cubes were cycled between liquid nitrogen and room temperature to simulate extreme exposure conditions. Subsequent compression testing showed the strength of cycled samples to be roughly five times less than those non-cycled. Fracture surface examination showed de-bonding of the sulfur from the aggregate material in the cycled samples but not in those non-cycled. The large discrepancy found, between the samples is attributed to the relative thermal properties of the materials constituting the concrete.

Grugel, Richard N.↗

Evaluation of Commercial-Off-The-Shelf (COTS) Electronics for Extreme Cold Environments

Deep space and Icy Moon missions (Titan, Enceladus, Ceres, Europa, & Ganymede) will need qualified extreme environment capable components for electronic systems located in extremities of their rovers and spacecraft. Commercial off the shelf (COTS) components would be advantageous to use for some aspects of such projects, given that they are easier to procure and offer a broad range of functionalities. Furthermore, theoretical and experimental data suggest that many COTS parts are capable of operation, and not just storage, at temperatures well beyond the manufacturer specified temperature limits. To help address the challenges presented at near cryogenic temperatures, a COTS selection knowledge base is being developed to estimate the performance of COTS components within cold environments. The knowledge base captures queries from a range of information sources such as cold functionality test results for part types and families, theoretical and experimental literature reviews and key findings are summarized here. In addition, a selection of components are planned to be examined for their performance to near cryogenic temperatures to generate a methodology for identification and verification of the COTS candidates. As the qualification of COTS parts for extreme environments can be very costly, this knowledge base can serve to reduce qualification time and cost by pre-selecting and limiting candidates.

Mojarradi, Mohammad↗

Performance Evaluation and Costs of a Combined Ground Source Heat Pump and Solar Photovoltaic Storage System in an Extreme Cold Climate

This report outlines the effectiveness and economics of a ground source heat pump system installed together with solar photovoltaic panels and a battery storage system in a local community building situated in a cold climate. The community building is a tribal building located in Ruby, Alaska. Power from solar photovoltaic panels is supplemented by electricity purchased from the local community microgrid. A ground source heat pump was commissioned three years after the building was occupied, and supplements the heat generated by a boiler for both heat and domestic hot water. Data collected over the 2021-2022 heating season shows that the heat pump is providing heat to the building about 19% of the time with an average coefficient of performance of 2.68, ranging from below 2.5 in winter to above 3.0 in summer. The solar photovoltaic panels provided 4,700 kWh of power used within the building and an additional 2,900 kWh exported to the microgrid. The solar-produced power used within the building nearly offsets the estimated annual electrical draw of the heat pump of 5,700 kWh. Due to the very high costs for shipping and installation to remote locations, projects such as this, while not economically feasible if self-funded, can save the community an estimated $76,051 over a period of 20-years. Fuel prices increasing by more than 25%, or subsidized electricity prices decreasing by more than 25%, make the ground source heat pump a more viable option economically. Unsubsidized electricity prices increasing by 25% or more make a solar photovoltaic system with battery storage nearly economically viable after a 20-year period for commercial or school buildings that are not eligible for Alaska's Power Cost Equalization program.

14 SOLAR ENERGY↗

Impact of heating and cooling loads on battery energy storage system sizing in extreme cold climates

Efficient operation of battery energy storage systems requires that battery temperature remains within a specific range. Current techno-economic models neglect the parasitic loads heating and cooling operations have on these devices, assuming they operate at constant temperature. In this work, these effects are investigated considering the optimal sizing of battery energy storage systems when deployed in cold environments. Here, a peak shaving application is presented as a linear programming problem which is then formulated in the PYOMO optimization programming language. The building energy simulation software EnergyPlus is used to model the heating, ventilation, and air conditioning load of the battery energy storage system enclosure. Case studies are conducted for eight locations in the United States considering a nickel manganese cobalt oxide lithium ion battery type and whether the power conversion system is inside or outside the enclosure. The results show an increase of 42% to 300% in energy capacity size, 43% to 217% in power rating, and 43% to 296% increase in capital cost dependent on location. This analysis shows that the heating, ventilation, and air conditioning load can have a large impact on the optimal sizes and cost of a battery energy storage system and merit consideration in techno-economic studies.

25 ENERGY STORAGE↗

Integration of Electrolysis Systems Into Isolated Microgrid Systems at Extreme Cold Climates

Isolated microgrid systems are generally used to power communities in remote locations where transmission line installations are cost prohibitive. These systems are usually powered by diesel generators, delivering expensive energy with high carbon emissions. However, most of these communities have special geographic access to renewable energy. These special conditions make it interesting to investigate the deployment of renewable energies and storage solutions. Within this scope, this paper analyses the integration of water electrolysis systems into off-grid communities, simulating the electrolyzer as well as the whole electrical grid in real time.

digital real-time simulation↗

Rational Electrolyte Formulation for Sodium Metal Batteries Operating in Extremely Cold Environments

Sodium metal batteries have shown considerable potential when operated at ambient temperatures. However, their performance in cold environments is constrained by increased electrolyte resistance with decreasing temperature and dendritic sodium plating associated with unstable solid electrolyte interphase (SEI), which are primarily influenced by the electrolyte composition. In this study, we present an electrolyte formulation that remains thermally stable down to −150 °C, which not only facilitates low internal resistance but also contributes to the formation of a protective SEI under cryogenic conditions. When cycled at −40 °C at 1 mA cm −2 , the sodium metal electrode exhibits a low overpotential of only 16 mV over 750 h; even at an ultra-low temperature of −80 °C, the electrode demonstrates remarkable long-term stability with a low overpotential of 54 mV sustained over 1500 h at 0.5 mA cm −2 . Furthermore, full cell evaluations when paring with Na 3 V 2 (PO 4 ) 3 cathode reveal a high average Coulombic efficiency exceeding 99.1% and a capacity retention over 83% after 100 cycles at both −40 °C and −80 °C.

Electrolyte↗

Molecular aspects of adaptation to extreme cold environments

Some of the various strategies adopted by living organisms for survival at low temperatures are discussed from the molecular and membrane points of view. Two examples of connections between biological cold adaptation and the molecular level are considered: (1) antifreeze proteins in fish from cold sea water and (2) the fluidity characteristics of cell membranes in a wide variety of organisms. Emphasis is placed on the occurrence of s-phases.

Finegold, Leonard↗

Boundary layer warming by condensation - Air-sea interaction during an extreme cold air outbreak from the eastern coast of the United States

Studies on an intense cold air outbreak that took place after a cold air cyclogenesis on January 27, 1986 are reviewed. Particular attention is given to data obtained during a multiaircraft research mission carried out on January 28, 1986 as part of the Genesis of Atlantic Lows Experiment. It was found that condensation heating of the subcloud layer air was comparable to heating by turbulent flux divergence.

Grossman, Robert L.↗

Evaluation Of Potting Materials For Use In Extreme Cold

Tests help identify noncracking combinations of materials. Aid evaluation of potting materials for copper coils used at low temperatures to measure magnetic fields. Also determine effects of distribution of microballoons, voids, and porosity. Materials also evaluated for ease of use.

Acosta, Ernesto↗

Experimental Evidence for Weathering and Martian Sulfate Formation Under Extremely Cold Weather-Limited Environments

High resolution photography and spectroscopy of the martian surface (MOC, HiRISE) from orbit has revolutionized our view of Mars with one of the most important discoveries being wide-spread layered sedimentary deposits associated with sulfate minerals across the low to mid latitude regions of Mars [1, 2]. The mechanism for sulfate formation on Mars has been frequently attributed to playa-like evaporative environments under prolonged warm conditions [3]. However, there are several problems with the presence of prolonged surface temperatures on Mars above 273 K during the Noachian including the faint young Sun [4] and the presence of suitable greenhouse gases [5]. The geomorphic evidence for early warm conditions may instead be explained by periodic episodes of warming rather than long term prolonged warm temperatures [6]. An alternate view of the ancient martian climate contends that prolonged warm temperatures were never present and that the atmosphere and climate has been similar to modern conditions throughout most of its history [6]. This view is more consistent with the climate models, but has had a difficult time explaining the sedimentary history of Mars and in particular the presence of sulfate minerals. We suggest here that mixtures of atmospheric aerosols, ice, and dust have the potential for creating small films of cryo-concentrated acidic solutions that may represent an important unexamined environment for understanding weathering processes on Mars [7, 8]. This study seeks to test whether sulfate formation may be possible at temperatures well below 0 C in water limited environments removing the need for prolonged warm periods to form sulfates on early Mars.

Niles, Paul B.↗