Search NASA⌕ Search

SEARCH · Search NASA

Results for “Extreme fast charging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Novel High‐Performance Electrolyte for Extreme Fast Charging in Pilot Scale Lithium‐Ion Pouch Cells

Realizing extreme fast charging (XFC) in lithium-ion batteries for electric vehicles is still challenging due to the insufficient lithium-ion transport kinetics, especially in the electrolyte. Herein, a novel high-performance electrolyte (HPE) consisting of lithium bis(fluorosulfonyl)imide (LiFSI), lithium hexafluorophosphate (LiPF 6 ) and carbonates is proposed and tested in pilot-scale, 2-Ah pouch cells. Moreover, the origin of improved electrochemical performance is comprehensively studied via various characterizations, suggesting that the proposed HPE exhibits high ionic conductivity and excellent electrochemical stability at high charging rate of 6-C. Furthermore, the HPE-based pouch cells deliver improved discharge specific capacity and excellent long-term cyclability up to 1500 cycles under XFC conditions, which is superior to the conventional state-of-the-art baseline electrolyte.

25 ENERGY STORAGE↗

Model-Instructed Design of Novel Charging Protocols for the Extreme Fast Charging of Lithium-Ion Batteries Without Lithium Plating

Relatively long recharge time of high-energy density lithium-ion batteries (LIBs) is one of the major obstacles to the widespread deployment of electric vehicles (EVs). Excessive fast charge of LIBs can cause severe safety issues, the most significant of which is lithium plating. In addition to the consumption of cyclable lithium, dendrite-like lithium plating can cause short-circuiting within the cell, which could lead to catastrophic failure. In addition to the developments of advanced electrolytes, active materials and electrodes, the fast charging capability of LIBs can be improved by using optimized charging protocol. In this paper, the Pseudo2D battery model is first used to screen some conventional charging protocols proposed for fast charging, including the constant-current constant-voltage charging (CCCV), constant-power constant-voltage charging (CPCV), multi-stage constant-current charging, and pulse current charging. A semi-optimal charging protocol is then developed by automatically modifying the charge current such that the cell is charged at close-to-maximum current without lithium plating. Based on the features of the semi-optimal protocol, two practical novel fast charging protocols are proposed which allow charging the cell at a higher rate without lithium plating. Through simulation, we show that the no-plating capacity after 10 min charge can be improved by up to ~10.7% compared to CCCV charging for a 2.5 mAh cm -2 cell and ~18.8% for a 4 mAh cm -2 cell, when the proposed charging protocols are used.

25 ENERGY STORAGE↗

Cybersecurity Framework Profile for Electric Vehicle Extreme Fast Charging Infrastructure

This document is the Cybersecurity Framework Profile (Profile) developed for the Electric Vehicle Extreme Fast Charging (EV/XFC) ecosystem, including the four domains that relies on the ecosystem (i) Electric Vehicles (EV); (ii) Extreme Fast Charging (XFC); (iii) XFC Cloud or Third-Party Operations; and (iv) Utility and Building Networks. This Profile utilizes the NIST Cybersecurity Framework Version 1.1 and provides voluntary guidance to help relevant parties develop Profiles specific to their organization to understand, assess, and communicate their cybersecurity posture as a part of their risk management process. The Profile is intended to supplement, not replace, an existing risk management program or cybersecurity standards, regulations, and industry guidelines that are in current use by the EV/XFC industry.

33 ADVANCED PROPULSION SYSTEMS↗

Quantification of heterogeneous, irreversible lithium plating in extreme fast charging of lithium-ion batteries

Realization of extreme fast charging (XFC, ≤15 minutes) of lithium-ion batteries is imperative for the widespread adoption of electric vehicles. However, dramatic capacity fading is associated with XFC, limiting its implementation. To quantitatively elucidate the effects of irreversible lithium plating and other degradation mechanisms on the cell capacity, it is important to understand the links between lithium plating and cell degradation at both the local and global (over the full cell) scales. Here, we study the nature of local lithium plating after hundreds of XFC cycles (charging C-rates ranging from 4C to 9C) in industrially-relevant pouch cells using spatially resolved X-ray diffraction. Our results reveal a spatial correlation at the mm scale between irreversible lithium plating on the anode, inactive lithiated graphite phases, and local state-of-charge of the cathode. In regions of plated lithium, additional lithium is locally and irreversibly trapped as lithiated graphite, contributing to the loss of lithium inventory (LLI) and to a local loss of active anode material. The total LLI in the cell from irreversibly plated lithium is linearly correlated to the capacity loss in the batteries after XFC cycling, with a non-zero offset originating from other parasitic side reactions. Finally, at the global (cell) scale, LLI drives the capacity fade, rather than electrode degradation. We anticipate that the understanding of lithium plating and other degradation mechanisms during XFC gained in this work will help lead to new approaches towards designing high-rate batteries in which irreversible lithium plating is minimized.

25 ENERGY STORAGE↗

Extreme Fast Charging: Effect of Positive Electrode Material on Crosstalk

Extreme fast charging (XFC) is a key requirement for the adoption of battery-based electric vehicles by the transportation sector. However, XFC has been shown to accelerate degradation, causing the capacity, life, and safety of batteries to deteriorate. We tested cells containing five positive electrode chemistries, LFP (olivine structure), LMO (spinel), LCO (layered), NMC811 (layered) and NCA (layered), using fast-charging protocols. After testing, the negative electrodes from cells containing positive electrodes crystallizing with a layered structure were found to have more lithium deposited on their surfaces. Further, those crystallizing with a layered structure also tended to have a larger increase in impedance than those crystallizing with a spinel or olivine structure. Characterization of the negative electrodes by X-ray photoelectron spectroscopy showed that using the concentrations of LiF and Li x PO y F z as metrics, the concentration of LiF in the SEI from the cell with different positive electrodes is LFP > LMO > LCO ~ NMC811 > NCA; and for Li x PO y F z , the order is LMO > LFP > NCA > NMC811 > LCO. Clearly, the positive-electrode material was influencing the amounts of these materials formed.

25 ENERGY STORAGE↗

Multilayer Electrodes with Metalized Polymer Current Collector for High-Energy Lithium-Ion Batteries with Extreme-Fast-Charging Capability

The pursuit of batteries capable of extreme fast charging (XFC), that also satisfy high energy and safety criteria, poses a significant challenge to current lithium-ion battery technologies. Additionally, the increasing demand for aluminum (Al) and copper (Cu) in electrification, and vehicle lightweighting is driving these metals towards near-critical status in the medium term. This study introduced metalized polymer films by depositing an Al or Cu thin layer onto two sides of a polyethylene terephthalate (PET) film – named mPET/Al and mPET/Cu, as lightweight, cost-effective alternatives to traditional metal current collectors in LIBs.

25 ENERGY STORAGE↗

Electromagnetic Transient (EMT) Simulation Algorithms for Evaluation of Large-Scale Extreme Fast Charging Systems (T&D Models)

Simulation of high-fidelity models of extreme fast charging (XFC) systems and large-area power grids with many XFCs can be time consuming in traditional simulators. Traditional simulators use a single method of discretization for all the components that results in imposing a large computational burden of inverting a large matrix as well as increased computations related to single method of discretization (that is typically a trapezoidal method). To overcome the problem of simulating large-area power grids with many XFCs, in this paper, advanced numerical simulation algorithms are applied for the first time together to reduce the dimension of matrix inversion. Here, the algorithms include numerical stiffness-based segregation, time constant-based segregation, clustering and aggregation on differential algebraic equations (DAEs), and multi-order integration approaches. These algorithms apply multiple discretization algorithms rather than a single discretization algorithm that further reduces the computational burden. The approaches mentioned here have resulted in speed-up of up to 18x in the simulation of a single distribution system with 15 XFCs and of up to 271x in the simulation of a transmission-distribution system with 300 XFCs in multiple distribution feeders with respect to conventional simulators (like power systems computer aided design [PSCAD]).

42 ENGINEERING↗

Design, Control, and Protection of a 13.2 kV, 1 MVA Solid State Transformer for Electric Vehicle Extreme Fast Charging Station

In this article, a medium-voltage (MV) ac-dc solid state transformer (SST) for electric vehicle (EV) extreme fast charging (XFC) station is proposed. The SST adopts a cascaded H-bridge (CHB)-based structure where the active front end (AFE) power stages are connected in input-series followed by dual active bridge (DAB) converters connected in an output-parallel configuration providing galvanic isolation through a high-frequency transformer (HFT). The SST is rated for 1 MVA and connects directly to a three-phase 13.2 kV MV ac grid through ac switchgear and outputs 750-V dc. At the dc bus, several dc/dc converters are connected, each of which can charge an EV based on its battery capacity. A novel decentralized control architecture of the SST is adopted in this work which simplifies the MV dc link voltage and module-level power balancing. In addition, the local and central protection designs of the SST are presented which identify and respond to the internal fault of the system. Finally, the experimental validations of the SST hardware prototype are presented up to the rated voltage. Furthermore, this article details the design and implementation of the MV SST addressing the challenges of an isolated MV class power converter for connecting directly to the MV ac grid with unique controller architecture, distributed protection framework, and SST constructional features.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extreme fast charge aging: Correlation between electrode scale and heterogeneous degradation in Ni-rich layered cathodes

Extreme fast charging (XFC) is a key requirement for the adoption of battery-based electric vehicles by the transportation sector. However, XFC has been shown to accelerate degradation, causing the capacity, life, and safety of batteries to deteriorate. There are no systematic studies in the open literature regarding aging modes in Ni-rich Li y Ni 0.a Mn 0.b Co 0.c O 2 (NMCabc) cathodes caused by fast charging. Herein, we report the effects of cathode composition and electrode loading in pouch cells containing NMC532, 622 and 811 paired with graphite and cycled under XFC conditions. The relative anisotropic volume change in the unit cell increases with Ni content in low-loading cells, while it levels up for all three NMC cathodes in high-loading cells because of substantial Li plating. The amounts of lithium plating and heterogeneity on the anode, determined by crystallographic phase quantification, were found to be correlated with electrode loading and cathode heterogeneity. The concentrations of the transition metals deposited on the anodes depend on NMCabc composition in a complex way. More particle cracking and surface degradation was found in NMC811. Here, the findings in this work provide a new understanding of the failure mechanisms and their practical implications for compositional tuning of future high-Ni NMCabc cathode materials during fast charging.

25 ENERGY STORAGE↗

Extreme fast charge aging: Effect of electrode loading and NMC composition on inhomogeneous degradation in graphite bulk and electrode/electrolyte interface

Empowering extreme fast charging (XFC) requires a comprehensive understanding of its application with advanced anode and cathode materials in lithium-ion batteries. No report exists for the full extent of limitations for the anode with crosstalk effect from paired cathode as well as Li plating due to electrode loading under XFC. In this study, a combination of cell testing and multiple length characterization is used to investigate XFC aging mechanism in cells with a low loading of 1.5 mAh cm -2 and high loading of 2.5 mAh cm -2 for graphite (Gr)/Ni-rich LiNi x Mn y Co 1-x-y O 2 (NMCs). Operando XRD mappings show 1.5 mAh cm -2 loadings result in higher strain in graphite for all three cathode types. Among the three NMC cathodes, the graphite from NMC532 and NMC811 cells show comparable strain. Scanning electron microscopy (SEM) images show distinct differences between 6-C-charged anodes in two loadings. Significantly increased electrode thickness can be seen due to more damage in the graphite bulk and accumulation of the electrolyte decomposition products in electrode pores. X-ray photoelectron spectroscopy (XPS) reveals both cathode chemistry and Li plating influence the non-uniform SEI composition on graphite surface. We report higher Ni content in NMC811 promotes the higher levels of salt decomposition on the SEI and formation of higher mass of electrolyte aging products.

25 ENERGY STORAGE↗

Highly Ordered Hierarchical Anodes for Extreme Fast Charging Batteries (Final Report)

The goal of this project is to enable extreme fast charging (XFC) of Li-ion batteries, which was accomplished through a combination of 1) rational design and manufacturing of hierarchically structured anode architectures; 2) blending graphite/hard carbon into a bulk hybrid anode; 3) engineering artificial solid-electrolyte interphase (SEI) coatings with reduced interphase impedance; 4) computational modeling of coupled transport, kinetic, and electrochemical phenomena; and 5) improved fundamental understanding of lithium plating through operando analysis. This work integrated structural, compositional, and surface modification of graphite anodes, multi-physics modeling of ion transport, electrochemical activity, and heat transfer, advanced strategies to detect Li plating, and semi-automated roll-to-roll cell assembly. The unique facilities at the University of Michigan (UM) and Sandia National Laboratories (SNL) were leveraged to manufacture, prototype, and characterize commercially relevant >2Ah and >180 Wh/kg cells with a target of <20% capacity fade over 500 XFC cycles.

25 ENERGY STORAGE↗

Enabling Extreme Fast Charging with Energy Storage Final Report

The objective of this project was to develop and demonstrate an extreme fast charging (XFC) station with three 350 kW charging ports that operate at a combined power exceeding 1 MW and mitigate the grid impact by employing smart charging algorithms, using an energy storage system, and connecting directly to a medium-voltage (15 kV-class three-phase) distribution feeder. This final report describes the team's achievements in all aspects of the technology development.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding extreme fast charge limitations in carbonate mixtures

Charging large format lithium ion batteries within ten to fifteen minutes requires changes to the electrolyte composition in addition to modification of electrode and cell architectures. Several approaches to address this need have been proposed; but there is not a lot of clarity on understanding which factors limit the performance of existing electrolytes. Furthermore, this work takes a closer look at the solvated components of a mixture of LiPF 6 in ethylene carbonate (EC) and ethyl methyl carbonate (EMC) in the context of extreme fast charging and relates these findings to cell-level requirements. Molecular dynamics studies of the Gen-2 electrolyte compositions with increasing salt concentrations, have been performed to estimate transport properties like diffusivity, transference number and conductivity. Molecular-level differences in the structure of solvation shells under extreme LiPF 6 concentrations are probed here and some key aspects on solvent structure that help overcome barriers to Li + transport under extreme fast charge are discussed.

25 ENERGY STORAGE↗

Electrode scale and electrolyte transport effects on extreme fast charging of lithium-ion cells

A combination of cell testing and electrochemical modeling is used to investigate extreme fast charging (XFC) performance for cells with a low loading of 1.5 mAh.cm -2 and moderate loading of 2.5 mAh.cm -2 . Cells with a low loading of 1.5 mAh.cm -2 withstand XFC performance remarkably well even up to 9C CC charging with high charge acceptance and very little lithium plating. For a moderate loading of 2.5 mAh.cm -2 , the 6C CC charge capacity is poor with significant amounts of lithium plating. Insufficient electrolyte transport properties are shown to be a major limitation for XFC performance of moderate and high loading cells. Charging at elevated temperature is shown to be an effective strategy for moderate loading cells enabling good 10-minute charge acceptance and mitigating lithium plating. Finally, the electrochemical model is used to investigate strategies for enabling 4-6C CC charging for cells with a loading of 3-4 mAh.cm -2 . A combination of elevated temperature, reduced tortuosity, and electrolytes with improved transport are likely needed to enable XFC for high energy density cells.

25 ENERGY STORAGE↗

Cybersecurity Platform and Certification Framework Development for Extreme Fast Charging (XFC)-Integrated Charging Ecosystem (Final Project Report)

This report summarizes a pioneering effort in Electric Vehicle charging infrastructure ecosystem cybersecurity requirements, assessment methodologies, functional verification, as well as embodiment of the key technologies in the form of hardware and software tools being made available to the public. EPRI led a team of experts, as well as a stakeholder coalition encompassing all key actors in the EV charging infrastructure ecosystem that includes eXtreme Fast Charging (XFC) equipment (defined as 200kW or above). EV charging infrastructure in the United States is a patchwork of networks that have continued to grow organically and have been designed to serve the charging needs of the EV owners, who are their customers. In doing so, each network provider, as well as their connected entities such as the cloud Electric Vehicle Service Providers or EVSPs, utility back office, utility AMI networks, payment networks, as well as Original Equipment Manufacturer (EV manufacturer) telematics networks, have designed systems that may work well individually, but no single entity is responsible for the entire ecosystem to be secure in terms of data exchange. Furthermore, there is no uniformity in how each actor has implemented the cybersecurity requirements since no system-wide cybersecurity requirements existed prior to this project. The final project report describes the technical approach guided by the EV charging infrastructure cybersecurity working group, convened specifically for this project. The technical approach included definition of requirements at the ecosystem level, treated as a ‘system of systems’, and then passed down to individual systems (EVSE, EV, cloud EVSP, utility, and the payment networks), followed by developing the cybersecurity risk and vulnerability assessment methods, that were later applied to real-world cyber-physical systems at EPRI, ANL, and NREL laboratories, to validate both the process and the results. Finally, in a spotlight over the most vulnerable equipment, which is the EV charge station (AC or DC), the team developed a multi-layer cybersecurity implementation in the embedded domain embodied by the open-source Secure Network Interface Card (SNIC) demonstrating the various ways in which the infrastructure can be secured protecting against the identified attack surfaces. Finally, the entire process of EV infrastructure cybersecurity assessment was encapsulated in the Electric Vehicle Charging Cybersecurity Management (EVC2M) online GUI-based tool, that is expected to be released to the public. The report presents the objectives, the technical approach, the key results, and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

Grid-Enhanced, Mobility-Integrated Network Infrastructures for Extreme Fast Charging (GEMINI-XFC)

Review of the FY20 and FY21 progress for the Grid-Enhanced, Mobility-Integrated Network Infrastructures for Extreme Fast Charging (GEMINI-XFC) project. GEMINI-XFC will use first-of-a-kind integrated high-fidelity grid and transport modeling to identify effective pathways for widespread electrification, to design and evaluate integrated vehicle-grid control schemes, and to optimize electric vehicle integration at a full regional scale with individual customer resolution.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗