Search NASA⌕ Search

SEARCH · Search NASA

Results for “FDIA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 records · Page 2

Attack-Resilient Weighted $\ell_{1}$ Observer with Prior Pruning

Security related questions for Cyber Physical Systems (CPS) have attracted much research attention in searching for novel methods for attack-resilient control and/or estimation. Specifically, false data injection attacks (FDIAs) have been shown to be capable of bypassing bad data detection (BDD), while arbitrarily compromising the integrity of state estimators and robust controller even with very sparse measurements corruption. Moreover, based on the inherent sparsity of pragmatic attack signals, ℓ1 -minimization scheme has been used extensively to improve the design of attack-resilient estimators. For this, the theoretical maximum for the percentage of compromised nodes that can be accommodated has been shown to be 50%. In order to guarantee correct state recoveries for larger percentage of attacked nodes, researchers have begun to incorporate prior information into the underlying resilient observer design framework. For the most pragmatic cases, this prior information is often obtained through some data-driven machine learning process. Existing results have shown strong positive correlation between the tolerated attack percentages and the precision of the prior information. In this paper, we present a pruning method to improve the precision of the prior information, given corresponding stochastic uncertainty characteristics of the underlying machine learning model. Then a weighted ℓ1 -minimization is proposed based on the pruned prior. The theoretical and simulation results show that the pruning method significantly improves the observer performance for much larger attack percentages, even when moderately accurate machine learning model used.

Resilient observer, Cyber-physical systems, prunin↗

Trust-Based Detection and Mitigation of Cyber Attacks in Distributed Cooperative Control of Islanded AC Microgrids

In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.

Computer Science↗

Resilient Observer Design for Cyber-Physical Systems with Data-Driven Measurement Pruning

Resilient observer design for Cyber-Physical Systems (CPS) in the presence of adversarial false data injection attacks (FDIA) is an active area of research. The existing state-of-the-art algorithms tend to break down as more and more knowledge of the system is built into the attack model; also as the percentage of attacked nodes increases. From the view of optimization theory, the problem is often cast as a classical error correction problem for which a theoretical limit of has been established as the maximum percentage attacked nodes for which state recovery is guaranteed. Beyond this limit, the performance of -minimization based schemes, for instance, deteriorates rapidly. Similar performance degradation occurs for other types of resilient observers beyond certain percentages of attacked nodes. In order to increase the corresponding percentage of attacked nodes for which state recoveries can be guaranteed, researchers have begun to incorporate prior information into the underlying resilient observer design framework. For the most pragmatic cases, this prior information is often obtained through a data-driven machine learning process. Existing results have shown a strong positive correlation between the maximum attacked percentages that can be tolerated and the accuracy of the data-driven model. Motivated by these results, this chapter examines the case for pruning algorithms designed to improve the Positive Prediction Value (PPV) of the resulting prior information, given stochastic uncertainty characteristics of the underlying machine learning model. Theoretical quantification of the achievable improvement is given. Simulation results show that the pruning algorithm significantly increases the maximum correctable percentage of attacked nodes, even for machine learning model whose prediction power is comparable to the random flip of a coin.

Resilient Observer, Cyber-physical Systems, Data-D↗

OT Operational Anomaly Detection (OAD) T&D + DER

The growth of utility-scale renewable energy resources, distributed energy resources (DER), and transportation electrification has increased uncertainty and cybersecurity risks in power grids. The Purdue Enterprise Reference Architecture model which is widely adopted by the utility industry is now insufficient to protect the power grid against cyber-attacks. There is a need to identify what cybersecurity model is effective on Energy Management System (EMS), Advanced Distribution Management System (ADMS), and DER Management System (DERMS) to address the fundamental cybersecurity challenges in the age of increasing renewable energy and DER share as well as consumer participation in the electric energy industry. The next generation of cybersecurity model for OT network should be able to detect inside attackers, mitigate the cybersecurity risks arising from the new grid participants including DER aggregators, electric vehicle owners, and behind-the-meter consumers outside the utility company, and develop the strategy to trust consumer measurement data. This panel will discuss the challenges and pathways for the development of an ensemble cybersecurity model based on predictive state estimation to detect cybersecurity anomalies in OT network including EMS, ADMS, and DERMS.

cybersecurity↗