Search NASA⌕ Search

SEARCH · Search NASA

Results for “FFR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

24 records · Page 2

Advancing sustainable aviation fuel with high-energy-density bicycloalkanes production from corn stover mixed sugars

Bicycloalkanes stand out as a replacement for aromatics from conventional jet fuel (CJF) because of their high energy density and lower freezing point. Most reports to date have focused on synthesizing bicycloalkanes using model compounds or single sugar components of lignocellulose. Here, we utilize all lignocellulosic sugars of corn stover (CS) to produce bicycloalkanes. First, furfural (FFR) and 5-hydroxymethyl furfural (5-HMF) are produced via acid-catalyzed dehydration, achieving combined FFRs molar yields ranging from 65% to 73%, respectively. The resulting FFRs are converted to cyclopentanones with molar yields within the range of 57%–63% via hydrogenation and Piancatelli rearrangement. Further aldol condensation of cyclopentanones yields C 10 -C 12 oxygenates with 80 mol %. Lastly, these oxygenates are directly hydrodeoxygenated to bicycloalkanes in a yield of 83.8 mol %. The resulting bicycloalkanes exhibit tier α fuel properties consistent with Jet A fuel (CJF) specifications and blend compatibility with CJF at a 37% volumetric ratio.

09 BIOMASS FUELS↗

Integrated assessment model diagnostics: key indicators and model evolution

Integrated assessment models (IAMs) form a prime tool in informing climate mitigation strategies. Diagnostic indicators that allow to compare these models can help to describe and explain differences in model projections. This also increases transparency and comparability. Earlier, the IAM community has developed an approach to diagnose models (Kriegler et al., 2015). Here we build on this, by proposing a selected set of well-defined indicators as a community standard, similar to metrics used for other modeling communities such as climate models. These indicators are the relative abatement index (RAI), emission reduction type index (ERT), inertia timescale (IT), fossil fuel reduction (FFR), transformation index (TI) and cost per abatement value (CAV). We apply the approach to 17 IAMs, including both older version as well as their latest versions, as applied in the IPCC 6th Assessment Report (AR6). The study shows that the approach can be easily applied and allows for comparison of model versions in time. The indicators and their trends can often be explained in terms of model characteristics and changes. We show that together, the set of six indicators can provide an useful indication of the main traits of the model and can roughly indicate the general model behavior. The results also show that there is often a considerable spread across the models. Interestingly, the diagnostic values often change for different model versions, but there does not seem to be a distinct trend across the different models.

54 ENVIRONMENTAL SCIENCES↗

Inactivation of Human Coronavirus by FATHHOME’s Dry Sanitizer Device: Rapid and Eco-Friendly Ozone-Based Disinfection of SARS-CoV-2

The pandemic of SARS-CoV-2/COVID-19 was reported in December 2019 in Wuhan, China. Pertaining to its high transmissibility and wide host adaptability, this unique human coronavirus spread across the planet inflicting 115 million people and causing 2.5 million deaths (as of March 3rd, 2021). Limited or negligible pre-existing immunity to multiple SARS-CoV-2 variants has resulted in severe morbidity and mortality worldwide, as well as a record-breaking surge in the use of medical-surgical supplies and personal protective equipment. In response to the global need for effective sterilization techniques, this study evaluated the virucidal efficacy of FATHHOME’s self-contained, ozone-based dry-sanitizing device, by dose and time response assessment. We tested inactivation of human coronavirus, HCoV-OC43, a close genetic model of SARS-CoV-2, on porous (N95 filtering facepiece respirator/FFR) and nonporous (glass) surfaces. We started our assays with 20 ppm-10 min ozone exposure, and effectively reduced 99.8% and 99.9% of virus from glass and N95 FFR surfaces, respectively. Importantly, the virus was completely inactivated, below the detection limit (over 6-log10 reduction) with 25 ppm-15 min ozone exposure on both tested surfaces. As expected, a higher ozone exposure (50 ppm-10 min) resulted in faster inactivation of HCoV-OC43 with 100% inactivation from both the surfaces, with no residual ozone present after completion of the 5-min post exposure recapture cycle and no measurable increase in ambient ozone levels. These results confirmed that FATHHOME’s device is suitable for rapid decontamination of SARS-CoV-2- from worn items, frequently touched items, and PPE including N95 FFRs, face shields, and other personal items. View Full-Text

59 BASIC BIOLOGICAL SCIENCES↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response: Preprint

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believes that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost benefit↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables: Preprint

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds after disturbance. To address this challenge, this paper proposes a frequency stability unit commitment constraint considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Thus, this paper first analyzes a frequency nadir differential equation that considers SG governor model and three kinds of FFR provided by IBRs. A system frequency nadir estimation framework is developed with consideration of various conventional SG and IBR models. The accuracy of this frequency estimation framework is validated by largest N-1 contingency simulation result of a real island system. Then, the adaptive inertia frequency stability unit commitment constraint is derived from sensitivity analysis method. Finally, we demonstrate the effectiveness of our developed constraints with one year day-ahead unit commitment results of the real island system.

fast frequency response↗