Search NASA⌕ Search

SEARCH · Search NASA

Results for “FIELD FAILURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Study program for design improvements of the X-3060 and X-3075. Phase 1: Study definition

The existing designs of the X-3060 and X-3075 klystrons were critically examined to determine whether or not realistic redesign goals could be established. Additionally, failure analyses and field failure reports were examined to identify any design weaknesses. Results of this critical analysis indicate that substantial improvements can be made to the overall design of both the X-3060 and X-3075 klystrons. Pertinent and detailed data concerning these improvements are reported herein.

Goldfinger, A.↗

Assessing the Causes of Encapsulant Delamination in PV Modules

Delamination of the encapsulant is one of the most prevalent PV module field failures. This paper will present examples of various types of delaminations that have been observed in the field. It will then discuss the development of accelerated stress tests designed to duplicate those field failures and thus provide tools for avoiding them in the future.

14 SOLAR ENERGY↗

Towards Validation of Advanced Accelerated Stress Testing Protocols through Failure Analysis and Materials Characterization

As the lifetime of photovoltaic modules increases toward the goal of 50 years, accelerated stress testing is critical to assessing the viability of newer, improved, and often cheaper materials in the field. However, the validation of accelerated testing to reproduce field failure has remained elusive. The recent developments of more advanced stress testing protocols utilizing sequential and combined stressors have provided another opportunity for validation. Using a suite of mechanical, chemical, and structural characterization methods we report the development of our approach using a known bad backsheet “AAA.” We then apply this approach to PVDF-based backsheets to further confirm the generalizability of this approach. The outcome of this work is two-fold: (1) validation of advanced accelerated testing protocols which will enable the prediction of field failures in new materials, and (2) deeper insights into the degradation mechanisms observed through the extensive characterization allowing for improved materials engineering and development.

accelerated aging↗

Development of Testing Methods to Predict Cracking in Photovoltaic Backsheets

In recent years there have been some significant failures of photovoltaic backsheets resulting from inadequacies of design that are not detected in current versions of the qualification standards. In some cases, this has resulted in catastrophic failure in less than 5 y of deployment. In this work, we develop a test sample construction and evaluate accelerated exposure conditions necessary to duplicate the cracking field failure of backsheets using a small and manageable coupon. This sample uses a piece of solder wire to put some controlled topology and stress into the backsheet. Through exposure to different environmental stressors it was found that the application of thermal cycling stresses, after ultraviolet radiation exposure, is of primary importance to duplicate field failures.

14 SOLAR ENERGY↗

Electrostatic Discharge (ESD) Failures in Thin Film Resistors

Field failures of nichrome thin film resistors have been investigated recently for several pieces of space flight hardware. These failures have involved resistance shifts ranging from a few percent to complete open circuits. Failure analysis and duplication of these failures have revealed that the failures were caused by electrostatic discharge. The failure characteristics and the circuit conditions necessary for failure have been studied for several types of thin film resistors including nichrome and tantalum nitride resistive elements. The effects of latent damage and resistive pattern design will also be discussed.

Hull, Scott M.↗

Generalized Spatio-Temporal Model of Backsheet Degradation From Field Surveys of Photovoltaic Modules

Photovoltaic (PV) module backsheets degrade at different rates because of the specific polymeric materials and the local exposure environments of the installations. Studies of real-world backsheet degradation provide valuable information to understand backsheet degradation and failure. Field surveys of PV module backsheets were conducted on 1310 modules in four commercial PV power plant sites with different exposure times. The backsheet's local exposure environment is determined by its location along the rack length and depth, the modules' elevation above the ground, and the ground cover albedo. Backsheets that are installed at the ends of the module rack length exhibit larger degradation rates (with yellowness index difference of 1.14 $\pm$ 0.45 and 7.80 $\pm$ 1.3 for backsheets of poly (ethylene terephthalate) and poly (ethylene naphthalate) as the air-side layer, respectively) than backsheets in the center section of the rack. A generalized spatio-temporal model was developed to predict the large-scale backsheet degradation of different backsheet polymers across time/age and location in the PV power plant rack. The model utilizes a cubic-spline relationship between backsheet degradation and rack length, and a quadratic relationship between backsheet discoloration and rack depth. This generalized spatio-temporal model predicts the outdoor backsheet degradation with an adjusted- $R^2$ range between 0.31 to 0.89. The similarity between this model and the spatial variation of the rear-side irradiance, indicates that the irradiance plays a significant role in outdoor backsheet degradation. The generalized spatio-temporal model can be used to evaluate large scale PV backsheet performance, as well as a guidance for PV site designers and operations and maintenance crews.

14 SOLAR ENERGY↗

Innovative Method for Welding in Generation 3 CSP to Enable Reliable Manufacturing of Solar Receivers to withstand Daily Cycling at Temperatures Above 700°C (Final Technical Report)

Inconel® Alloy 740H® (alloy 740H) was the first age-hardenable nickel-based alloy approved by the ASME Boiler & Pressure Vessel Code for use in pressure-boundary applications. Over the past ~20 years the alloy has been optimized for weldability and high-temperature stability, approved for use in different applications. Development of a supply chain combined with the advantageous properties of the alloy (high-temperature creep strength, oxidation and corrosion resistance, etc.) have resulted in the alloy being applied to new high-temperature power cycle demonstration projects, and of particular interest are applications to concentrating solar power (CSP) to enable higher-efficiency Generation 3 CSP systems and the corresponding supercritical CO 2 (sCO 2 ) power cycle components (heat exchangers, piping, etc.). The high allowable stresses of alloy 740H also make it a desirable material for current Generation 2 CSP solar power receivers to improve cyclic capability and/or reduce receiver height. Recent experiences in demonstration projects utilizing alloy 740H identified cracking issues during welding and fabrication. In this project, a detailed study was done to confirm and clarify the Stress Relaxation Cracking (SRxC) mechanism, also known as stress relief cracking or strain-age cracking (SAC), during post-weld heat-treatment (PWHT). This involved detailed microscopy and advanced characterization to understand the root cause(s) of three failures obtained from industry. Based in-part on these findings, a targeted laboratory based SRxC test method was utilized to evaluate variables such as heat-to-heat variations, strain level, PWHT temperature, and starting material condition on three heats of alloy 740H. Industrial shop welding of cold-worked plates was also conducted. The research showed the following: SRxC was confirmed as the cracking mechanism for all field failures; Stress state (from residual stresses, constraint, deformation, and local stress concentrations) was playing a significant role in field failures and laboratory testing confirmed increasing susceptibility for all heats with increasing strain levels. High levels of microstructural strain were identified at crack initiation locations, in some cases leading to local recrystallization; Precipitate free zones (PFZs) at grain boundaries were found at relaxation cracks and crack initiation locations uniquely associated with SRxC in alloy 740H. Laboratory testing reproduced this microstructural feature which had only previously been reported in long-term creep testing of weldments. Advanced nano-scale characterization confirmed the presence of a moving boundary leading to coarsening of precipitates and PFZs where damage accumulated; The research suggested heat-to-heat variations due to local chemistry and processing may influence SRxC susceptibility, but more work is needed to fully clarify these effects. To disseminate the key learnings from this research to the scientific and engineering communities and alloy 740H end users, multiple technical publications and presentations were made, an industrial alloy 740H users meeting was held, and a new industry guideline specification document which can be directly implemented by end-users of alloy 740H was produced.

14 SOLAR ENERGY↗

Investigation of Spiral Bevel Gear Condition Indicator Validation via AC-29-2C Combining Test Rig Damage Progression Data with Fielded Rotorcraft Data

This is the final of three reports published on the results of this project. In the first report, results were presented on nineteen tests performed in the NASA Glenn Spiral Bevel Gear Fatigue Test Rig on spiral bevel gear sets designed to simulate helicopter fielded failures. In the second report, fielded helicopter HUMS data from forty helicopters were processed with the same techniques that were applied to spiral bevel rig test data. Twenty of the forty helicopters experienced damage to the spiral bevel gears, while the other twenty helicopters had no known anomalies within the time frame of the datasets. In this report, results from the rig and helicopter data analysis will be compared for differences and similarities in condition indicator (CI) response. Observations and findings using sub-scale rig failure progression tests to validate helicopter gear condition indicators will be presented. In the helicopter, gear health monitoring data was measured when damage occurred and after the gear sets were replaced at two helicopter regimes. For the helicopters or tails, data was taken in the flat pitch ground 101 rotor speed (FPG101) regime. For nine tails, data was also taken at 120 knots true airspeed (120KTA) regime. In the test rig, gear sets were tested until damage initiated and progressed while gear health monitoring data and operational parameters were measured and tooth damage progression documented. For the rig tests, the gear speed was maintained at 3500RPM, a one hour run-in was performed at 4000 in-lb gear torque, than the torque was increased to 8000 in-lbs. The HUMS gear condition indicator data evaluated included Figure of Merit 4 (FM4), Root Mean Square (RMS) or Diagnostic Algorithm 1(DA1), + 3 Sideband Index (SI3) and + 1 Sideband Index (SI1). These were selected based on their sensitivity in detecting contact fatigue damage modes from analytical, experimental and historical helicopter data. For this report, the helicopter dataset was reduced to fourteen tails and the test rig data set was reduced to eight tested gear sets. The damage modes compared were separated into three cases. For case one, both the gear and pinion showed signs of contact fatigue or scuffing damage. For case two, only the pinion showed signs of contact fatigue damage or scuffing. Case three was limited to the gear tests when scuffing occurred immediately after the gear run-in. Results of this investigation highlighted the importance of understanding the complete monitored systems, for both the helicopter and test rig, before interpreting health monitoring data. Further work is required to better define these two systems that include better state awareness of the fielded systems, new sensing technologies, new experimental methods or models that quantify the effect of system design on CI response and new methods for setting thresholds that take into consideration the variance of each system.

spiral bevel gears↗

Microstructure changes during failure of PVDF-based photovoltaic backsheets

The backsheet layer of a solar module provides a safety and environmental barrier to the high voltages running through the photovoltaic (PV) cells and electrical contacts within the core of the module. However, in the past decade, backsheet cracking has become one of the most observed failure modes in PV module field surveys. In this work, the degradation of polyvinylidene fluoride (PVDF)-based backsheets is explored. Backsheet samples are either exposed to accelerated laboratory aging (UV light, heat, and moisture) or collected from the field. Fourier transform infrared and Raman spectroscopy, fragmentation testing, atomic force and scanning electron microscopy, and small-angle neutron scattering are combined to develop an understanding of how chemistry and microstructure evolve during aging. Chemical degradation, surface pitting, polymer phase changes, and anisotropic polymer domains are all observed in aged backsheet samples. The results provide insight into the degradation mechanisms that lead to cracking and field failure of PVDF-based backsheets. The comparison of aged PVDF-based backsheets helps to lay the groundwork for limiting polymer-based failure modes in PV modules.

PVDF↗

Failure propagation in multi-cell lithium ion batteries

Traditionally, safety and impact of failure concerns of lithium ion batteries have dealt with the field failure of single cells. However, large and complex battery systems require the consideration of how a single cell failure will impact the system as a whole. Initial failure that leads to the thermal runaway of other cells within the system creates a much more serious condition than the failure of a single cell. This work examines the behavior of small modules of cylindrical and stacked pouch cells after thermal runaway is induced in a single cell through nail penetration trigger [1] within the module. Cylindrical cells are observed to be less prone to propagate, if failure propagates at all, owing to the limited contact between neighboring cells. However, the electrical connectivity is found to be impactful as the 10S1P cylindrical cell module did not show failure propagation through the module, while the 1S10P module had an energetic thermal runaway consuming the module minutes after the initiation failure trigger. Modules built using pouch cells conversely showed the impact of strong heat transfer between cells. In this case, a large surface area of the cells was in direct contact with its neighbors, allowing failure to propagate through the entire battery within 60-80 seconds for all configurations (parallel or series) tested. This work demonstrates the increased severity possible when a point failure impacts the surrounding battery system.

25 ENERGY STORAGE↗

Effect of electrical field on TSA failure of cement-based materials

The impact of electrical field on the sulfate attack of cement-based materials at low temperatures was studied to rapidly detect Thaumasite Sulfate Attack (TSA) in the laboratory and in future engineering. Sulfate attack of cement paste with 30 wt% replacement of CaCO{sub 3} powder soaked in Na{sub 2}SO{sub 4} solution, MgSO{sub 4} solution, or CaSO{sub 4} solution was measured under the condition of 5 ± 2 °C when an electrical field was applied. Appearance changes and compressive strength of the samples were tested to evaluate the corrosion degree. Scanning Electron Microscopy (SEM), X-ray Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR) and Raman Spectroscopic measurements were applied to study the microstructure of the corrosion product. The test results indicate that sample damage was obvious, compression strength declined rapidly, and ettringite and/or thaumasite were found in the corrosion product after applying the electrical field for 90 days. A muddy product with TSA characteristics was formed, and thaumasite composition was found in the corrosion product after applying the electrical field for 120 days when MgSO{sub 4} solution was used as the corrosion medium. It is confirmed that an electrical field can accelerate TSA failure in cement-based materials.

36 MATERIALS SCIENCE↗

Towards validation of combined-accelerated stress testing through failure analysis of polyamide-based photovoltaic backsheets

Abstract Novel methods for advancing reliability testing of photovoltaic (PV) modules and materials have recently been developed. Combined-accelerated stress testing (C-AST) is one such method which has demonstrated reliable reproduction of some field-failures which were not reproducible by standard certification tests. To increase confidence and assist in the development of C-AST, and other new testing protocols, it is important to validate that the failure modes observed and mechanisms induced are representative of those observed in the field, and not the product of unrealistic stress conditions. Here we outline a method using appropriate materials characterization and modelling to validate the failure mechanisms induced in C-AST such that we can increase confidence in the test protocol. The method is demonstrated by applying it to a known cracking failure of a specific polyamide (PA)-based backsheet material. We found that the failure of the PA-based backsheet was a result of a combination of stress factors. Photo-oxidation from ultra-violet (UV) radiation exposure caused a reduction in fracture toughness, which ultimately lead to the cracking failure. We show that the chemical and structural changes observed in the backsheet following C-AST aging were also observed in field-aged samples. These results increase confidence that the conditions applied in C-AST are representative of the field and demonstrates our approach to validating the failure mechanisms induced.

14 SOLAR ENERGY↗

Combustion Safety Simplified Test Protocol Field Study

"9Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Combustion Safety Simplified Test Protocol, Chicago Illinois, and Minneapolis, Minnesota

"9Combustion safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Survey of Mechanical Durability of PV Backsheets

The ability to maintain mechanical properties after applied environmental stress is a good indicator for long term durability of a backsheet. This work surveys a set of 56 backsheet films, some of which are known to fail in the field and evaluates them utilizing the proposed photovoltaic weathering standard IEC 62788-7-2. While the complete study examined optical reflectance characterization, tensile testing, dielectric testing, and a mandrel bend test, this paper focuses on the mandrel bend test results. All seven of the transparent specimens failed. A polyamide based backsheet known to fail in the field did not fail the bend test. It is believed that the field failure is due to an interaction with the encapsulant and/or the cyclic mechanical exposure experienced in the field. When cracks occur, they happen predominantly in the polyethylene terephthalate for transparent backshees or the 'E' layer for opaque films, never in a fluoropolymer layer.

14 SOLAR ENERGY↗

Environmental testing of terrestrial flat plate photovoltaic modules

The Low-Cost Solar Array (LSA) Project at the Jet Propulsion Laboratory has as one objective: the development and implementation of environmental tests for flat plate photovoltaic modules as part of the Department of Energy's terrestrial photovoltaic program. Modules procured under this program have been subjected to a variety of laboratory tests intended to simulate service environments, and the results of these tests have been compared to available data from actual field service. This comparison indicates that certain tests (notably temperature cycling, humidity cycling, and cyclic pressure loading) are effective indicators of some forms of field failures. Other tests have yielded results useful in formulating module design guidelines. Not all effects noted in field service have been successfully reproduced in the laboratory, however, and work is continuing in order to improve the value of the test program as a tool for evaluating module design and workmanship. This paper contains a review of these ongoing efforts and an assessment of significant test results to date.

Hoffman, A.↗

Achieving Improved Reliability with Failure Analysis

Reliability is the ability of a product to properly function, within specified performance limits, for a specified period of time, under the life cycle application conditions. Failure analysis is a vital tool in the effort to ensure reliability of electronic products and systems throughout their product lifecycle. Today, organizations involved in activities within the electronics supply chain are facing new challenges, not just from complex assembly styles, harsher lifecycle environments, and sophisticated supply chains, but also from customers who are demanding a quicker turn-around. Unfortunately, root cause failure analysis is often performed incompletely, leading to a poor understanding of failure mechanisms and causes and, customer dissatisfaction due to recurring failures. The PDC starts with an introduction to reliability concepts, physics of failure and an overview of failure mechanisms that affect PCBs, PCBAs and components. The PDC then dives into root cause hypothesizing techniques (Pareto, FMEA, fishbone, FTA), non-destructive and destructive analysis and, materials characterization will be discussed. Numerous failure analysis case studies will be used to illustrate the techniques and analysis principles to arrive at the root cause(s) of field failures on printed circuit boards, active components, and assemblies. What Will You Learn: Topics include: Overview of Reliability Concepts Failure mechanisms of electronic products Root cause analysis Failure analysis techniques -Non-destructive techniques (optical, CSAM etc.) -Destructive analysis (DPA, Decap, FIB etc.) -Materials characterization (XRF, EDS, TMA/DSC etc.) Who Will Benefit: Reliability engineers, failure analysis engineers, engineering managers, design engineers, component engineers, quality assurance functions and, personnel involved with reliability activities within their company.

non-destructive techniques↗

Printed Circuit Board Inspection and Quality Control - PCB Failure Causes and Cures

This two day workshop will discuss a range of topics, including root cause analysis, physics-of-failure principles and failure mechanisms in printed circuit boards. Printed circuit boards (PCBs) are the baseline for electronics manufacturing upon which electronic components are mounted and formed into electronic systems. PCBs are used in a variety of electronic circuits from simple one-transistor amplifiers to large super computers. A PCB serves three main functions: 1) it provides the necessary mechanical support for the components in the circuit 2) it provides the necessary electrical interconnections, and 3) it bears some form of legend which identifies the components it carries. The failure modes on the PCBs can be categorized in a hierarchical structure, in which the mechanisms and causes are site or location dependant. Specimen preparation techniques, non-destructive and destructive analysis, and materials characterization will also be discussed. The first day of the workshop will present methodologies for identifying potential failure mechanisms in electronics based on the failure history and, systematic approaches to root cause analysis. The second day will cover failure analysis techniques geared towards various failure mechanisms, along with numerous component and PCB assembly failure analysis case studies that illustrate the techniques and analysis. Failure analysis case studies will be used to illustrate the techniques and analysis principles to arrive at the root cause(s) of field failures on printed circuit boards, active components, and assemblies.

Printed circuit boards↗