Gf-values of ultraviolet Fe I, Cr I, and Cr II lines from shock-tube measurements.
UV Fe I, Cr I and II lines gf values obtained by flash absorption spectroscopy on pressure driven shock tube
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
UV Fe I, Cr I and II lines gf values obtained by flash absorption spectroscopy on pressure driven shock tube
The Bureau of Reclamation is presently involved in a unique Geothermal Resource Development Program in Imperial Valley, California. The main purpose of the investigations is to determine the feasibility of providing a source of fresh water through desalting geothermal fluids stored in the aquifers underlying the valley. Significant progress in this research and development stage to date includes extensive geophysical investigations and the drilling of five geothermal wells on the Mesa anomaly. Four of the wells are for production and monitoring the anomaly, and one will be used for reinjection of waste brines from the desalting units. Two desalting units, a multistage flash unit and a vertical tube evaporator unit, have been erected at the East Mesa test site. The units have been operated on shakedown and continuous runs and have produced substantial quantities of high-quality water.
An efficient micro-resistojet has been developed with thrust in the millinewton level, with a specific impulse of approximately 250 seconds and power input of 20 watts or less that is useful for applications of up to 1,000 hours of operation or more. The essential feature of this invention is a gas-carrying tube surrounding a central heating element. The propellant is flashed into vapor and then passes through a narrow annulus between the tube and the heater where it is cracked (in the case of methanol, into CO and H2) before being discharged through a de Laval nozzle to produce thrust. A multi-layer radiation shield around the gas tube minimizes heat loss. Also, if methanol is used as the propellant, the simultaneous heating and cracking does not need an additional device. This unit would be especially useful for small satellites, with mass up to 100 kg, and for delta v up to 500 m/sec, and is suited for use with green methanol as the propellant where a specific impulse of 220 seconds is expected. Noble metal alloys are the optimal materials of construction. While the microresistojet is especially suited to methanol, many other propellants may be used such as water or, in the case of de-orbiting, many other residual liquids onboard the vehicle.
Brazing process attaches thermocouples to slot in type-347 stainless steel tube flush around its circumference. Electrolytic flashing with gold enhances brazing process. This installation procedure does not significantly change calibration of thermocouples used and does not cause major wear spots in the thin-walled devices.
Thermal diffusivity measurements on Zirconium-based cladding materials have historically been a challenge due to the difficulty to measure on specimens with curved geometries, including nuclear grade Zircaloy cladding materials. In this work, we first used Laser Flash Analysis methods to measure the thermal diffusivity of Zircaloy tubes, which show good agreement with Zircaloy plates in this work, as well as previously published data. The consistent results proved the applicability of the Laser Flash Analysis setup for investigating thermal diffusivity of Zircaloy tubes. We further investigate the hydrogen effect on thermal diffusivity of Zircaloy tubes. Hydrogen plays significant roles in temperature dependent thermal diffusivity trends of Zircaloy tube. For low hydrogen concentration, where hydride dissolved into single phase α-Zr at higher temperature, thermal diffusivity is relatively unchanged at low temperature at two phase regions (α-Zr and δ-hydride), and it increases as a function of temperature at single phase α-Zr region. For high hydrogen concentration, where phase transformation (α-Zr + δ-hydride → α-Zr + β-Zr) occurs at 567 °C, thermal diffusivity decreases as a function of temperature below 567 °C before the transformation (α-Zr and δ-hydride), while increase at higher temperature after the transformation (α-Zr and β-Zr).
A more congested space environment due to increasing space activities introduces new threats to spacecraft operators. Among these threats include hypervelocity impacts from microparticles (< 1 µg) in the form of meteoroids and space debris. These microparticles travel at speeds between 11.2 and 72.8 km/s with respect to the Earth and can impact spacecraft forming a small (~1 µm) and dense (~ 10 26 m -3 ) plasma. This plasma can generate a strong optical emission (impact flash) and a radio frequency (RF) emission. These emissions can lead to spacecraft electrical anomalies when the impacted spacecraft surface (target) carries high electrical potential due to various space weather effects. To understand the microparticle hypervelocity impact plasma and its associated threat to spacecraft electronics, we studied the hypervelocity impact flash expansion geometry under various spacecraft surface electrical conditions. Three high-speed broadband photomultiplier tubes (PMT) are used to capture the temporal evolution of the impact flash and the temporal evolution of the angular distribution of the impact flash expansion geometry in a 3 MV electrostatic dust accelerator during a ground-based experiment. Overall, results indicate that the impact surface electrical condition has a statistically significant influence on the impact flash geometry, and a strong similarity between the impact plasma and flash expansion geometry. Thus, this paper provides new experimental support for the impact flash origin from and connection with the impact plasma, and serves as the first impact flash expansion geometry characterization under various impact surface electrical conditions in a collisionless environment (< 10 -5 Torr).
In a nuclear reactor, prolonged exposure to high neutron flux levels can change material properties of reactor components. Due to the danger posed to personnel by highly radioactive components such as spent fuel, noncontact methods must be used to determine these properties. The objective of the current research is to test the viability of using a flash-heating method to determine the thermal diffusivity of a silicon carbide (SiC) tube, which could be used as cladding for a nuclear fuel rod. The flash-heating experiment was conducted at Oak Ridge National Laboratory and temperature results were analyzed as a two-Dimensional cross section which assumed axial symmetry. The model was fitted iteratively to the temperature measurements using nonlinear regression which required values for thermal diffusivity, Biot number and a term to determine the magnitude of the heat absorbed by the flash. The method could be expanded in the future to estimate the thermal diffusivity of spent nuclear fuel rods in an effort to increase the certainty of new reactor designs using precise thermal properties throughout the core life. A statistical analysis of the results of this work is provided as part of the analysis.
Cladding thermal conductivity is an important physical property in assessing the performance of silicon carbide (SiC)-cladded fuels for nuclear reactors. However, there is a significant lack of reliable data, particularly for irradiated materials, because the geometry complicates the measurement. This study investigates the thermal diffusivity of coupons with a curvature, machined from SiC fiber–reinforced SiC matrix composite tubes, with and without neutron irradiation under light water reactor–relevant temperature and dose conditions. The tested materials included full composite and duplex SiC composite tubes. The measurements were conducted using a modern flash diffusivity apparatus. The analyzed area on the specimen during diffusivity testing was reduced for improved measurement accuracy due to sample curvature. Post-irradiation measurements showed that the effects of neutron irradiation on thermal conductivity (e.g. thermal defect resistivity) are different between SiC composite plates versus tubes. The difference was explained by higher matrix density of the tube than the plate. This study provides reliable thermal properties of prototypic SiC composite tubes useful for fuel performance modeling of SiC-based cladding.
Parameters of gas pressure, type of gas, tube voltage, and electrode gap are tested on the intensity and shape of a radiation pulse from a hydrogen-filled lamp.
Choking and shock in flashing single component two phase flow in tube, including vibrational effects, predicting minimum stagnation pressure loss
Lean premixed, prevaporized (LPP) high temperature combustor designs as explored for the Advanced Subsonic Transport (AST) and High Speed Civil Transport (HSCT) combustors can achieve low NO(x), emission levels. An enabling device is needed to arrest flashback and inhibit preignition at high power conditions and during transients (surge and rapid spool down). A novel flashback arrestor design has demonstrated the ability to arrest flashback and inhibit preignition in a 4.6 cm diameter tubular reactor at full power inlet temperatures (725 C) using Jet-A fuel at 0.4 less than or equal To phi less than or equal to 3.5. Several low pressure loss (0.2 to 0.4% at 30 m/s) flashback arrestor designs were developed which arrested flashback at all of the test conditions. Flame holding was also inhibited off the flash arrestor face or within the downstream tube even velocities (less than or equal to 3 to 6 m/s), thus protecting the flashback arrestor and combustor components. Upstream flow conditions influence the specific configuration based on using either a 45% or 76% upstream geometric blockage. Stationary, lean premixed dry low NO(x) gas turbine combustors would also benefit from this low pressure drop flashback arrestor design which can be easily integrated into new and existing designs.
Here, the Richtmyer–Meshkov instability causes perturbations to grow after a shock traverses a fluid density interface. This increases the mixing rate between fluid from either side of the interface. We use the Flash Eulerian hydrodynamic code to investigate alterations when a thin third layer of intermediate density is placed along the interface, effectively creating two adjacent unstable interfaces. This is a common occurrence in engineering applications where a thin barrier initially separates two materials. We find that the width of the mixing layer is similar or slightly reduced; however, the total mass of mixed material can actually increase. The mixing layer becomes more compact and efficient. However, the normalized mixed mass decreases, meaning that finger entrainment becomes more important than in the simple two-layer case. The effect of adding the central layer appears to decrease when the Atwood number is decreased. The Flash results are also benchmarked against two-layer experimental data from a shock tube at the University of Arizona.
The invention is a laser head for simultaneous pumping several dye lasers with a single flash lamp. The laser head includes primarily a multi-elliptical cylinder cavity with a single flash lamp placed along the common focal axis of the cavity and with capillary tube dye cells placed along each of the other focal axes of the cavity. The inside surface of the cavity is polished. Hence, the single flash lamp supplies the energy to the several dye cells.
Thermal diffusivity measurements on Zirconium-based cladding materials have historically been a challenge due to the difficulty to measure on specimens with curved geometries, including nuclear grade Zircaloy cladding materials. Here, in this work, we first used laser flash analysis method and four-probe configuration method to measure the thermal diffusivity and electrical resistivity of Zircaloy tubes respectively, which show good agreement with Zircaloy plates in this work, as well as previously published data. The consistent results proved the applicability of the laser flash analysis setup and four-probe configuration method for investigating thermal diffusivity and electrical resistivity of Zircaloy tubes. We further investigated the hydrogen effect on thermal diffusivity and electrical resistivity of Zircaloy. Hydrogen plays significant roles in the thermal diffusivity of Zircaloy, which depends on the hydrogen concentration. For higher hydrogen contents (1130 and 1820 wppm in this work), where phase transformation (α-Zr + δ-hydride → α-Zr + β-Zr) occurs at 567 °C, thermal diffusivity decreases as a function of temperature at the α-Zr + δ-hydride phase regime, while increase at higher temperature at the α-Zr + β-Zr phase regime. For low hydrogen concentration, where hydride dissolved into α-Zr matrix phase at higher temperature, the thermal diffusivity is lower than non-hydrided Zircaloy-4 with similar temperature-dependent trends. Such observation demonstrates the hydrogen effects on reducing thermal diffusivity of α-Zr phase. Hydrogen increases the electrical resistivity of Zircaloy. Similar to thermal diffusivity results, the phase transformation causes a reversal of temperature-dependent trends in electrical resistivity results in Zircaloy-4 with higher hydrogen contents.
Leak checking and evaluation of pressure vessels by observing the slight temperature changes resulting from structural anomalies has been made possible through developments in high resolution infrared cameras and advanced image processing. These developments have made thermal nondestructive analysis a very practical and efficient method to determine material consistency and structural quality as well as monitor processes. The Space Shuttle Main Engine Nozzle has regions which can not be inspected with standard leak check methods. The Thermographic methods being developed to nondestructively test the Nozzle for leaks in inaccessible regions are reported. Also, a flash heating Thermographic investigation of the braze line bonding the cooling tubes to the outer structural jacket of the nozzle is reported.
A simple laboratory method for determining flash fire propensity of materials is described. The apparatus consists of a tube furnace and a combustion tube. The ignition source can be a wooded match but the hot pyrolysis tube itself may be the most suitable ignition source. Test results are presented for various materials including polyethylene, polystyrene, polycarbonate, and polyurethane and polychloroprene flexible foams.
The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate γ-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with flash analog-to-digital converters. Here, we present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.
Each flashlamp is supported coaxially within a pyrex water-jacket tube by two identical connector assemblies, one at each end. These connector assemblies not only support the flashlamp mechanically, but also provide source and return pathways for flashlamp DI cooling water and for electrical current. At each end of the flashlamp, the (presumably) tungsten feed-through rod that supports the electrode is attached to a connector assembly through a Multilam fitting. O rings seated on the outside of each connector assembly form a water-tight seal between the connector assembly and the inside of the pyrex water-jacket tube. During operation, DI cooling water enters the tube located at the end of one of the connectors, flows over that connector’s Multilam fitting, flows through a ring of holes in the connector assembly and then flows into the 1-mm gap between the flashlamp and the pyrex water-jacket tube. After passing over the length of the flashlamp, the water flows through the connector assembly at the opposite end of the flashlamp and exits through that connector assembly’s end tube. Electrical pulses are delivered to the flashlamp through the tubes coming out of the connector assemblies.