Observations on the maximum average stress of flat plates buckled in edge compression
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Laminar film boiling from an inclined flat plate has been investigated analytically. Using the singular perturbation scheme, the complete set of Navier-Stokes equations is solved. The zeroth-order perturbation coinciding with the boundary-layer equations for vertical flat plates governs the problem. The higher-order perturbations become important near the leading edge and for large values of the inclination angle from the vertical. The assumption of zero interfacial velocity shows that, except for fluids having large (rho x mu) ratios, the results can be predicted using the vertical flat plate results by defining a modified Grashof parameter containing a cos phi term. When the interfacial shear is considered, the solutions indicate that for fluids having large (rho x mu) ratios, the heat transfer rates will be larger (approximately 15% maximum) than those predicted by the simplified model using zero interfacial velocity. In general, the inclination decreases the rate of heat transfer as well as the rate of evaporation.
Power input to small flat plate from diffusely radiating sphere with application to earth satellites - spinning plate
The solar 2 air flat plate collectors are described. The development and fabrication of a prototype air flat plate collector subsystem containing 320 square feet of collector area are described. Three instrumented panels were completely assembled with glazing and insulation. Manufacture of the last seven prototype collectors was completed in October 1977.
A flat-plate wind tunnel model of an advanced fighter configuration was tested in the NASA LaRC Subsonic Basic Research Tunnel and the 16- by 24-inch Water Tunnel. The test objectives were to obtain and evaluate the low-speed longitudinal aerodynamic characteristics of a candidate configuration for the integration of several new innovative wing designs. The flat plate test allowed for the initial evaluation of the candidate planform and was designated as the baseline planform for the innovative wing design study. Low-speed longitudinal aerodynamic data were obtained over a range of freestream dynamic pressures from 7.5 psf to 30 psf (M = 0.07 to M = 0.14) and angles-of-attack from 0 to 40 deg. The aerodynamic data are presented in coefficient form for the lift, induced drag, and pitching moment. Flow-visualization results obtained were photographs of the flow pattern over the flat plate model in the water tunnel for angles-of-attack from 10 to 40 deg. The force and moment coefficients and the flow-visualization photographs showed the linear and nonlinear aerodynamic characteristics due to attached flow and vortical flow over the flat plate model. Comparison between experiment and linear theory showed good agreement for the lift and induced drag; however, the agreement was poor for the pitching moment.
The lift on a bent, flat plate is calculated exactly by the use of conformal mapping. Results are presented in terms permitting direct determination of the angle of zero lift, the lift coefficient, and the lift-curve slope for any flap-chord ratio, flap-deflection angle, and angle of attack.
The paper describes the Transverse Flat Plate Heat Pipe Experiment. A transverse flat plate heat pipe is a thermal control device that serves the dual function of temperature control and mounting base for electronic equipment. In its ultimate application, the pipe would be a lightweight structure member that could be configured in a platform or enclosure and provide temperature control for large space structures, flight experiments, equipment, etc. The objective of the LDEF flight experiment is to evaluate the zero-g performance of a number of transverse flat plate heat pipe modules. Performance will include: (1) the pipes transport capability, (2) temperature drop, and (3) ability to maintain temperature over varying duty cycles and environments. Performance degradation, if any, will be monitored over the length of the LDEF mission. This information is necessary if heat pipes are to be considered for system designs where they offer benefits not available with other thermal control techniques, such as minimum weight penalty, long-life heat pipe/structural members.
External heat-transfer rates were measured on a flat plate in the junction region of a circular cylinder mounted normal to the plate at a location 90 deg from the stagnation point. This configuration simulates the junction of the shroud with gas-turbine vanes. Heat-transfer results are presented for laminar, transition, and turbulent boundary layers for a Mach number of 0.14 with gas temperatures of approximately 750 deg R over a flat plate at room temperature. The measurements were made in air for a unit Reynolds number, Re/cm, range of 11,000 to 58,000. Heat-transfer measurements were conducted in the 70-ft long, 4-in. diameter shock tube. A shock-wave reflection technique was used to produce a flow Mach number of 0.14. Thin-film platinum heat gages were mounted on the flat plate and along the line of the stagnation point of the cylinder to measure the local heat flux in the junction region. The experimental heat-transfer data were correlated with the laminar and turbulent boundary-layer theories for the flat plate. With the cylinder the heat fluxes on the flat plate were greatly increased in the junction region compared to the heat flux for the plate alone.
Friction factors for honeycomb surfaces were measured with a flat plate tester. The flat plate test apparatus was described and a method was discussed for determining the friction factor experimentally. The friction factor model was developed for the flat plate test based on the Fanno Line Flow. The comparisons of the friction factor were plotted for smooth surfaces and six-honeycomb surfaces with three-clearances, 6.9 bar to 17.9 bar range of inlet pressures, and 5,000 to 100,000 range of the Reynolds number. The optimum geometries for the maximum friction factor were found as a function of cell width to cell depth and cell width to clearance ratios.
Friction factors for honeycomb surfaces were measured with a flat plate tester. The flat plate test apparatus was described and a method was discussed for determining the friction factor experimentally. The friction factor model was developed for the flat plate test based on the Fanno Line Flow. The comparisons of the friction factor were plotted for smooth surfaces and six-honeycomb surfaces with three-clearances, 6.9 bar to 17.9 bar range of inlet pressures, and 5,000 to 100,000 range of the Reynolds number. The optimum geometries for the maximum friction factor were found as a function of cell width to cell depth and cell width to clearance ratios.
Flat plate models are often used in wind tunnel testing to make measurements of the boundary layer, but preclude the use of conventional focused laser differential interferometry (FLDI) measurements, particularly for measurements at the surface of the model. By instead focusing light in only one direction using cylindrical optics, as opposed to two directions using only spherical optics, FLDI measurements can be made without truncating the beam at the model edges. Measurements at discrete points along a line can also be acquired, effectively acting as many individual FLDI instruments in a single measurement. Here, a two-line FLDI system has been constructed that allows for the measurement lines to be easily oriented at any azimuthal angle about the optical axis since the optics are housed in rotation mounts. Velocity measurements at points along a line or between two lines are also possible, since the beams are split similar to the two-point FLDI instrument. The system was first characterized in the laboratory using a laser-induced breakdown spark to provide a well-defined density fluctuation, along with high-speed schlieren measurements for comparison. The system was then installed at the NASA Langley 20-Inch Mach 6 Air Tunnel to make measurements through the boundary layer of a flat plate model and in the tunnel freestream.
This evaluation of the flat-plate collector system was designed to determine the number of flat-plate collectors required to generate a given amount of electricity with optimum efficiency. Variable parameters are the temperature of the heat-transport fluid, both to and from the collector field. In the analysis, the efficiency of the flat-plate collectors was coupled to the efficiency of the thermal cycle to calculate optimal overall system efficiencies. Overall system efficiencies for the system are on the order of 3.5 per cent or less. Over two million 4 ft-by-4 ft collectors would be required to produce 100,000 kW(e). Based on the results, it can be shown that the limiting factor in the use of the flat-plate collector system for electric power generation is the efficiency of the collectors. An increase in the overall system efficiency can occur only if the collector efficiency can be increased at higher surface temperatures.
A one-dimensional nonstationary three-element distributed thermal model of a flat-plate collector with allowance for time variation of the temperatures through the “thickness” of the elements and along the length of the solar collector (SC) has been developed and software-implemented. The main data in this model consist of the thermophysical and overall parameters of the collector elements, heat carrier inlet velocity, solar radiation density, and ambient and sky temperature. To decrease the calculation variants, the variation ranges of mass flow of the heat carrier and its flow velocity were estimated for the characteristic parameters of the heat-removal channels of flat-plate SCs. It has been found that the specific mass flows of water in flat-plate SCs are 2.5–10 g/(s m{sup 2}), and the water flow velocity is 0.0005–0.002 m/s. It is shown that the instantaneous efficiency coefficient and temperature of the heat carrier can fall outside stationary values within 1–3 h. However, the daily efficiency coefficients of the SC do not fall outside the stationary values even within a day. The developed flat-plate SC model can be used to estimate the influence of the thermophysical and overall parameters of the elements, as well as the parameters of the environment, on its thermophysical characteristics when developing flat-plate SCs and methods for experimentally determining their characteristics.
The various factors governing buckling of flat plates are critically reviewed and the results are summarized in a comprehensive series of charts and tables. Numerical values are presented for buckling coefficients of flat plates with various boundary conditions and applied loadings. The effects of plasticity are incorporated in non dimensional buckling charts utilizing the three-parameter description of stress-strain curves.
Supersonic jet plume interaction with a flat plate was studied using a model scaled test apparatus designed to simulate plume/aircraft structure interaction for the cruise configuration. The generic configuration consisted of a rectangular supersonic nozzle of aspect ratio 7, and a large flat plate located beneath the nozzle at various nozzle plate distances; the plate was instrumented to measure surface dynamic pressure and mean wall temperature, with provisions for measurements of acceleration and strain on coupon size panels that could be inserted in the plate. Phase-averaged schlieren measurements revealed the presence of high-intensity acoustic emission from the supersonic plume above the plate, directed upstream; this radiation could be associated with the shock noise generation. Narrow band spectra of surface dynamic pressure show spectral peaks with amplitude levels reaching 1 psi, related to the screech tones. Temperature measurements indicated elevated surface temperatures in regions of high turbulence intensity.