Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOWSHEETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis of the Sludge Batch 9 (Macrobatch 11) DWPF Pour Stream Glass Sample Collected During the Nitric-Glycolic Acid Flowsheet Transition

A pour stream (PS) sample taken near the end of processing of Sludge Batch 9 (SB9, Macrobatch 11) during the transition to the nitric-glycolic acid (NGA) flowsheet was analyzed by the Savannah River National Laboratory (SRNL). The SB9 NGA PS sample was taken on 12/18/2022 during Melter Feed Batch 823 associated with glass canister S04773 and was transferred to SRNL in Primary Container PC0139 in February 2023.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass Property-Composition Models Update for use in Direct Feed High-Level Waste Flowsheet Development

A set of preliminary glass property models and constraints were developed and augmented by models from literature for use in design of direct-feed high-level waste (DFHLW) glasses for flowsheet evaluation, testing, and design of the Tank Waste Treatment and Immobilization Plant (WTP) high-level waste (HLW) Facility. These models and constraints are meant to be used as a place-holder while glass property-composition data gaps are filled and final plant operating models are developed. This report describes the motivation and intended use of the models, the compilation of data, model fitting and selection, methods to apply the models and constraints in glass design and offers example calculations demonstrating their intended use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass Property-Composition Models Update for use in Direct Feed High-Level Waste Flowsheet Development: EWG3.0

A set of preliminary glass property models and constraints were developed and augmented by models from literature for use in design of Direct Feed High-Level Waste glasses for flowsheet evaluation, testing, and design of the High-Level Waste Facility at the Hanford Waste Treatment and Immobilization Plant. These models and constraints are meant to be used as a placeholder while glass property-composition data gaps are filled and final plant operating models are developed. This report describes the motivation and intended use of the models, the compilation of data, model fitting and selection, and methods to apply the models and constraints in glass design, and offers example calculations demonstrating their intended use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass Property-Composition Models Update for use in Direct Feed High-Level Waste Flowsheet Development: EWG2.6

A set of preliminary glass property models and constraints were developed and augmented by models from literature for use in design of direct-feed high-level waste (DFHLW) glasses for flowsheet evaluation, testing, and design of the Waste Treatment and Immobilization Plant (WTP) high-level waste (HLW) Facility. These models and constraints are meant to be used as a place-holder while glass property-composition data gaps are filled and final plant operating models are developed. This report describes the motivation and intended use of the models, the compilation of data, model fitting and selection, methods to apply the models and constraints in glass design and offers example calculations demonstrating their intended use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Evaluation of the Impact of Glycolate and Glycolate Mitigation on the Defense Waste Processing Facility Recycle Diversion Project Flowsheet

The Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) processes radioactive High Level Waste (HLW) sludge solids from the Concentration, Storage, and Transfer Facilities (CSTF); which includes the SRS Tank Farm and Evaporator facilities, and a concentrated Cs-137 laden stream and a Monosodium Titanate (MST) and sludge solids stream from the SRS Salt Waste Processing Facility (SWPF). The waste is chemically adjusted with acids and reductant (currently with 50 wt.% nitric acid and ~90 wt.% formic acid, but eventually formic acid will be substituted with ~70 wt.% glycolic acid), and frit is added so that a durable, borosilicate glass waste form can be produced when the material is vitrified in the melter. As a result of the evaporation of water during both the melter feed preparation and the melter feed vitrification steps in DWPF, a recycle waste stream is generated, neutralized, and sent back to the CSTF. The recycle waste is a dilute aqueous stream originating from the collection of condensate liquids containing some minor sludge, MST, and frit solids and other waste components resulting from melter feed entrainment during foamover events and transfer of volatile species into the condensate. The recycle stream volume is significant and is expected to approach 3 million gallons per year once SWPF reaches full operation, requiring the use of multiple large CSTF tanks for storage. The recycle waste is currently collected in the SRS Tank Farm and periodically evaporated in the 242-16H (2H) Evaporator to conserve storage space.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sludge Batch 10 Flowsheet Testing with Non-radioactive Simulants

Fourteen Chemical Processing Cell (CPC) simulations were performed with nonradioactive sludge simulants at the Aiken County Technology Laboratory in Aiken, SC. Four of these experiments were performed with Tank 51 sludge simulant. The remaining ten were performed with Tank 40 sludge simulant. The purpose of these experiments was to elucidate the chemistry and characteristics of Sludge Batch (SB) 10 as anticipated in the Defense Waste Processing Facility (DWPF). Experiments were performed at acid stoichiometries between 76% and 138% of the Koopman Minimum Acid requirement (85% - 144% of the Hsu acid requirement) and at REDuction/OXidation (REDOX) targets between 0.1 and 0.3. Testing examined the impact of coupled operations and sludge-only operations during Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) processing at both design basis and nominal boilup rates. This report shares conclusions made as a result of this testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Increased Fissile Loading Flowsheet Review

A request was made by H-Canyon Process Engineering to assess the impact of blending dissolved, neutralized Spent Nuclear Fuel (SNF) with future sludge batches and their impact on downstream processing facilities including the Concentration, Storage and Transfer Facilities (CSTF), the Salt Waste Processing Facility (SWPF), the Defense Waste Processing Facility (DWPF), Saltstone, and the Effluent Treatment Facility (ETF). The purpose of this change is to accelerate the deinventory of SNF which is currently stored in the L-Area Disassembly Basin. The addition of SNF increases the mass of fissiles in each future sludge batch, due to their high enrichment. This high enrichment has the potential to complicate the programs to eliminate criticality events in the downstream processing facilities and will increase the number of canisters produced by DWPF because of the SNF mass increase. A separate report addressed the impacts to glass. The review and subsequent calculations were based on average predicted compositions of Accelerated Basin Deinventory (ABD) slurry, average compositions for predicted future sludge batches, average past salt batches and average past recycle batches to predict the feeds that will be processed in SWPF, DWPF, Saltstone, the 2H evaporator and ETF. Each of the processes was evaluated for potential issues.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Increased Fissile Loading Flowsheet Review

A request was made by H-Canyon Process Engineering to assess the impact of blending dissolved, neutralized Spent Nuclear Fuel (SNF) with future sludge batches and their impact on downstream processing facilities. The purpose of this change is to accelerate the deinventory of SNF which is currently stored in the L-Area Disassembly Basin.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flowsheet for the Neutralization of Accelerated Basin De-inventory (ABD) Material

Under the Accelerated Basin De-inventory (ABD) program H-Canyon will be dissolving aluminum spent nuclear fuel (ASNF) and then neutralizing that solution without performing head-end strike or uranium recovery operations. After dissolution in H-Canyon the material will be neutralized to a free hydroxide concentration of either 0.6 M or 1.2 M to meet the waste acceptance criteria for transfer to the SRS Concentration, Storage and Transfer Facility (CSTF). In order to ensure the material could be successfully neutralized and transferred, SRNL completed experiments with simulated H-Canyon dissolver solutions. Two bounding simulants were developed based on the expected compositions of ASNF to be dissolved, one containing only Gd as the neutron poison and one containing Fe as an additional poison.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

H-Canyon Flowsheet for the Neutralization of Dissolved Fast Critical Assembly (FCA) Fuel

The H-Canyon facility will be dissolving unirradiated stainless-steel clad Fast Critical Assembly (FCA) fuel in HNO3 and neutralizing the resulting solution with 50 wt% NaOH with no recovery operations prior to transfer to the Concentration, Storage, and Transfer Facility (CSTF). There are two types of FCA fuel, including a Pu-Al metal alloy and a mixed U and Pu oxide. H-Canyon anticipates dissolving 16 batches of the metal fuel and two batches of the oxide fuel. Potassium fluoride will be added to the dissolver solution at 0.05 M to promote dissolution. Gadolinium will be added after the dissolution as a thermal neutron poison for criticality control. H-Canyon requested that SRNL evaluate Gd:239Pu equivalent (239PuEq) ratios of 1:1 and 10:1. The neutralization process precipitates metals including actinides, Gd, and cladding components resulting in a slurry. Caustic neutralization is a routine H-Canyon operation, but the FCA dissolver solution will be unique relative to solutions that are typically processed due to the stainless-steel components, high HNO3 concentration of ~8.5 M, and an initial Pu concentration of up to 4 g/L. Previous neutralization studies have been performed for Pu containing solutions but at less than half the initial Pu concentration and much lower initial HNO3 concentrations. Experimental neutralizations targeted a final free hydroxide (OH-) concentration of 0.6 M as this was anticipated to be the final endpoint, but H-Canyon now expects the endpoint to be 1.2 M OH-. The purpose of this study was to characterize the distribution of the actinide, Gd, and cladding components between the precipitate and supernate, determine if the slurry will back up in the header during the transfer to the CSTF, and determine if solids will settle in the pipeline during the transfer.

Mills, Matthew S.↗

All-LiCl Flowsheet Development

Annual report on the LiCl Pyro project. The objectives of this project are to begin work to determine the feasibility of transitioning to LiCl-only electrorefining for reprocessing nuclear fuel.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Antifoam Development for Eliminating Flammability Hazards and Decreasing Cycle Time in the Defense Waste Processing Facility

The Savannah River National Laboratory (SRNL) was requested to develop a new antifoam control method for the Defense Waste Processing Facility’s (DWPF) Chemical Process Cell (CPC). SRNL completed testing of both chemical and nonchemical foam controls. The nonchemical foam controls were either ineffective (or worse, created more foam) or impractical (a water spray can control foam, but excessive water is needed). As a result, the focus of this study was on finding a superwetter or commercial antifoam for controlling foam. Thirty potential antifoams were tested as part of this study. A series of tests were developed to help screen out ineffective alternatives including: 1. Spreading testing of superspreaders, 2. Foam column testing with physical simulants, 3. Boiling testing with physical and chemical simulants, 4. Days-only Sludge Receipt and Adjustment Tank (SRAT) process simulations with sludge (containing noble metals and mercury), Precipitate Reactor Feed Tank (PRFT), and Slurry Mix Evaporator Feed Tank (SEFT) simulants in the RC1 Reaction Calorimeter (purchased for antifoam testing), and 5. Around-the-clock SRAT and Slurry Mix Evaporator (SME) process simulations with sludge(containing noble metals and mercury), PRFT, and SEFT simulants in the RC1 Reaction Calorimeter. Evonik Surfynol® MD20, a commercially available defoamer, was relatively effective in controlling foam, while remaining chemically stable in SRAT and SME processing across the pH range of 4 to 13. No degradation products were detected in the offgas, in the condensate or in the SRAT and SME products. In nitric-glycolic acid flowsheet testing, 250 mg/kg Evonik Surfynol® MD20 was needed for foam control compared to 1,625 mg/kg for Antifoam 747, DWPF’s current antifoam. In nitric-formic acid flowsheet testing, 1,125 mg/kg of Evonik Surfynol® MD20 was needed to control foam throughout the SRAT and SME cycles. The commercially available superspreader Momentive™ Y-17112 was even more effective than Evonik Surfynol® MD20 as both a defoamer and an antifoam. Not only was the foam destroyed upon addition but also was less persistent between additions. It was the most effective antifoam in testing using both the nitric-glycolic acid flowsheet and the nitric-formic acid flowsheet. In nitric-glycolic acid flowsheet testing, only 100 mg/kg Momentive™ Y-17112 was needed to control foam throughout the SRAT and SME cycles. In nitric-formic acid flowsheet testing, 300 mg/kg Momentive™ Y-17112 was needed to control foam throughout the SRAT and SME cycles. Momentive™ Y-17112 is also resistant to hydrolysis as demonstrated by its chemical stability in SRAT and SME processing across the pH range of 4 to 13 and lack of degradation products in offgas or condensate. Both candidates were effective as potential replacements for Antifoam 747, with Y-17112 demonstrating superior foam control. During nitric-glycolic flowsheet testing 50% less antifoam was needed when using Momentive™ Y-17112 compared to MD20. During nitric-formic flowsheet testing 75% less antifoam was needed when using Momentive™ Y-17112 compared to MD20. Foam remediated with Momentive™ Y-17112 was less persistent throughout testing. In addition, no degradation products were detected in the offgas, in the condensate or in the SRAT and SME products. Based on this testing, Momentive™ Y-17112 is clearly superior to Evonik Surfynol® MD20 and Antifoam 747, especially for the nitric-formic acid flowsheet processing; it is recommended that Momentive™ Y-17112 replace Antifoam 747 in DWPF. An antifoam addition strategy is recommended for both the nitric-glycolic acid flowsheet and the nitric-formic acid flowsheet. Implementation of Momentive™ Y-17112 is expected to decrease SRAT and SME boiling times by up to 50%, eliminate the issues resulting from Antifoam 747 degradation products, and minimize foamovers. To validate the effectiveness of these defoaming agents, SRNL recommends irradiation of a SRAT or SME product simulant containing fresh antifoam. The goal of this testing is to determine whether the irradiation causes decomposition of the antifoam that would make it less effective or produce new species in the offgas or slurry. This testing began in April 2020. An evaluation should be completed to determine the thermolytic hydrogen and methane generation rate in downstream equipment, including the High-Level Waste evaporators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CoDCon Project (Final Report)

The co-decontamination (CoDCon) project was established in FY 2016 with the objectives of (a) evaluating the uncertainty in the uranium (U)/plutonium (Pu) ratio in a mixed U/Pu product from a tributyl phosphate (TBP)–based solvent extraction flowsheet, and (b) developing and demonstrating on-line optical spectroscopy for real-time monitoring of key components (e.g., Pu, U, and HNO 3 concentrations) in the process solutions. We were interested in assessing the accuracy and precision to which a specific uranium-to-plutonium (U/Pu) ratio can be achieved, which for the purposes of this project was set at a U/Pu mass ratio of 7/3. The uncertainty associated with achieving this specific target U/Pu ratio was investigated during five flowsheet tests using laboratory-scale solvent extraction equipment. In addition, optical spectroscopic techniques were incorporated into the CoDCon solvent extraction testing system, allowing real time monitoring of all input and output process streams. Two CoDCon flowsheet tests were performed in FY 2018 using a simple dissolved fuel simulant containing only U (~1 M) and Pu (~15 mM) in nitric acid (HNO 3 ; ~3 M). In FY 2019, two additional flowsheet tests were performed. For the first of these (CoDCon Run 3), the dissolved fuel simulant was similar to that used in the first two tests, with the inclusion of 1 mM neptunium (Np). The second test conducted in FY 2019 (CoDCon Run 4) used a more representative dissolved fuel simulant, including addition of non-radioactive fission product elements. A fifth CoDCon flowsheet test (CoDCon Run 5) was conducted in FY 2020, with the following additional objectives: (1) routing of the technetium (Tc) in the simulated dissolved fuel solution to the solvent extraction raffinate, and (2) routing of the Np in the simulated dissolved fuel solution to the U/Pu product. All tests used a bank of sixteen 2 cm centrifugal contactors. The tests involved first loading the solvent (30 vol% TBP dissolved in n-dodecane) with U and Pu (and Np, for Run 5), then the Pu (and Np) was stripped from the loaded solvent with a U(IV) solution (~50 mM) and the flowsheet conditions were adjusted such that some U partitioned into the Pu-containing product stream. The amount of U accompanying the Pu was monitored in real time using optical spectroscopic techniques coupled with chemometric modeling. Based on the real-time spectroscopic measurement of the U/Pu ratio, adjustments were made to the flowrate of the fresh TBP solvent phase used to scrub U from the aqueous Pu-containing product. This proved to be a very effective way to control the U/Pu mass ratio in the product. This report presents the results of the CoDCon Run 5 test. The flowsheet tested in Run 5 was substantially different than that run in the prior tests, especially the solvent loading section of the flowsheet. Two key changes were made. First, based on the objective to extract all the Np and route it with the U/Pu product, pentavalent vanadium [V(V)] was added to the feed and scrub solutions. The purpose of the V(V) was to convert all the Np to the +6 oxidation state, which is extractable by TBP. Second, a high acid (8 M HNO 3 ) scrub was added to the flowsheet to scrub the Tc from the solvent. This was followed by a low acid scrub (0.05 M HNO 3 ) to reduce the residual HNO 3 concentration in the solvent prior to the Pu stripping step. The output from the low acid scrub was collected separately, rather than routing towards the raffinate. The modifications to the solvent loading part of the flowsheet were only partially successful. The treatment with V(V) was effective at converting the Np to Np(VI). Only 1.3% of the Np remained in the raffinate solution. However, ~40% of the Np stripped out of the solvent in the low acid scrub step; nearly 20% of the Pu also was stripped from the solvent during the low acid scrub. For further development, either modifications to the flowsheet, or concentration and recycle of the low acid stream into the

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impacts of the Addition of Sodium Reactor Experiment (SRE) and DR-3 Fuel from H-Canyon to Tank 40 on Acid Stoichiometry and Hydrogen Production

H-Canyon plans to discard Sodium Reactor Experiment (SRE) material that is currently stored in Tanks 16.3 and 16.4. Savannah River Remediation (SRR) determined that a portion of the SRE material can be added to Sludge Batch 9 (SB9) in Tank 40 and the remainder will be added to Sludge Batch 10 (SB10) that is currently being prepared in Tank 51. A processing flowsheet for both the nitric-formic acid flowsheet and the nitric-glycolic acid flowsheet were previously developed for SB9 sludge-only and coupled operation with the Actinide Removal Process – Modular Caustic Side Solvent Extraction Unit (ARP-MCU) and the Salt Waste Processing Facility (SWPF). Due to the compositional change in Tank 40 after the addition of SRE material, it is necessary to determine the influence on the acid stoichiometry operating window and hydrogen production for SB9 processing. An assessment was completed to address the influence of an addition of SRE and DR-3 Fuel from H-Canyon on the chemistry of Tank 40, the defined acid stoichiometry window (with and without SWPF streams) for the nitric-formic and nitric-glycolic acid flowsheets, and the resulting influence of the hydrogen production. Hydrogen production during the SRAT/SME cycles consists of thermolytic, radiolytic, and catalytic hydrogen. For the nitric-formic acid flowsheet, catalytic hydrogen dominates the hydrogen production during DWPF operation mode for the SRAT and SME vessels. This report was written to summarize that assessment. No SRNL testing is needed prior to adding up to 7,100 additional gallons of SRE and DR-3 Fuel from H-Canyon to Tank 40. Also, the addition of SRE will not exceed the Shielded Cells reported values for catalytic hydrogen for either the nitric-formic acid flowsheet (Technical Safety Requirement (TSR) limit of 0.15 lb/h) or the nitric-glycolic acid flowsheet (TSR limit 0.024 lb/h). The addition of the ARP stream from SWPF and the use of the nitric-glycolic acid flowsheet are both expected to decrease hydrogen generation, leading to a larger safety margin in the CPC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Concepts for Actinide Recovery from TRISO Used Nuclear Fuel

The work described in this report has developed a preliminary conceptual flowsheet based on limited published literature for the head-end of a TRISO oxycarbide UNF reprocessing plant. The essential function of the head-end is to prepare the UNF for subsequent separation of actinides. The main steps of the conceptual TRISO UNF head-end reprocessing flowsheet are: 1. Fragmentation of the graphite moderator to expose the fuel particles. 2. Separation of fuel particles from fragmented graphite moderator by sieving and fluidization. 3. Fragmentation of the fuel particles to expose the fuel kernel. 4. Dissolution of the fuel kernel in nitric acid. Noteworthy at this step is the formation of organic acids (mainly oxalic and mellitic acids) from the carbon associated with the fuel and TRISO coatings. These acids can interfere with actinide separations and solvent extraction hydraulic performance and carbon dioxide gas generation. 5. Clarification of the dissolved fuel solution to separate the coating fragments. 6. Dissolver off-gas treatment with specific emphasis on managing generation of carbon dioxide gas containing carbon-14. The quantity of carbon dioxide is projected to be 100 to 1000 times greater than that arising from dissolving LWR UNF. Pre or post treatment of the exposed fuel kernels could be undertaken to mitigate the formation of organic acids but there still exists a significant off-gas treatment challenge. The literature on reprocessing uranium nitride UNF was reviewed but a flowsheet was not specifically developed since its scope and uncertainties are expected to be encompassed by the oxycarbide flowsheet. Overall, the predominant feature of processing TRISO UNF is carbon management to reduce waste volume and mitigate the formation of carbon dioxide and organic acids. This report recommends broad areas of research that will help to further define the head-end flowsheet.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗