Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUORESCEIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Use of an ocular wound chamber for the prevention of exposure keratopathy in a guinea pig model

Abstract Current therapies available to treat and heal ocular surface injuries and periocular burns are frequently inadequate, costly, and labor intensive. To address these limitations, we have employed a flexible, semitransparent ocular wound chamber (OWC) to provide protection as well as a watertight seal to allow for the constant delivery of therapeutics to the ocular surface and surrounding periocular tissue. This study demonstrates the safety and utilization of the OWC on uninjured eyes and in our exposure keratopathy model. For initial safety studies ( N = 3 per group), the eyelids remained intact and the eye uninjured. A blepharotomy ( N = 6 per group) was performed to remove the upper and lower eyelids surrounding the left (OS) eye to create our exposure keratopathy model. Right (OD) eyes served as uninjured controls in all studies. Following OWC placement, 0.5 mL HPMC gel or balanced saline solution (BSS) was injected into the chamber. Animals were monitored daily and fully assessed via white light, fluorescein, and OCT imaging at least through 72 hours post OWC placement. In studies that included a blepharotomy, skin samples were analyzed by multiplex cytokine analysis. Results of safety experiments revealed no significant differences between treatment groups in corneal thickness, fluorescein staining, OCT imaging, or histological eye or skin sections when compared to control eyes. In our exposure keratopathy model, OWC treated eyes showed significantly less fluorescein uptake and also were found to have significantly lower levels of cytokines IL‐13 and IL‐5 in skin samples. These results demonstrate for the first time that treatment using the OWC device is not only safe, but significantly protects against blepharotomy‐induced exposure keratopathy. As a whole, this study advances our overall efforts to develop a feasible solution to treat ocular surface injuries, infections, and periocular burns.

Holt, Andrew W.↗

Retinal Image Quality Assessment for Spaceflight-Induced Vision Impairment Study

Long-term exposure to space microgravity poses significant risks for visual impairment. Evidence suggests such vision changes are linked to cephalad fluid shifts, prompting a need to directly quantify microgravity-induced retinal vascular changes. The quality of retinal images used for such vascular remodeling analysis, however, is dependent on imaging methodology. For our exploratory study, we hypothesized that retinal images captured using fluorescein imaging methodologies would be of higher quality in comparison to images captured without fluorescein. A semi-automated image quality assessment was developed using Vessel Generation Analysis (VESGEN) software and MATLAB® image analysis toolboxes. An analysis of ten images found that the fluorescein imaging modality provided a 36% increase in overall image quality (two-tailed p=0.089) in comparison to nonfluorescein imaging techniques.

retina↗

Magnetic mesoporous materials for removal of environmental wastes

We have synthesized two different magnetic mesoporous materials that can be easily separated from aqueous solutions by applying a magnetic field. Synthesized magnetic mesoporous materials, Mag-SBA-15 (magnetic ordered mesoporous silica) and Mag-OMC (magnetic ordered mesoporous carbon), have a high loading capacity of contaminants due to high surface area of the supports and high magnetic activity due to the embedded iron oxide particles. Application of surface-modified Mag-SBA-15 was investigated for the collection of mercury from water. The mercury adsorption using Mag-SBA-15 was rapid during the initial contact time and reached a steady-state condition, with an uptake of approximately 97% after 7 hours. Application of Mag-OMC for collection of organics from water, using fluorescein as an easily trackable model analyte, was explored. The fluorescein was absorbed into Mag-OMC within minutes and the fluorescent intensity of solution was completely disappeared after an hour. In another application, Mag-SBA-15 was used as a host of tyrosinase, and employed as recyclable catalytic scaffolds for tyrosinase-catalyzed biodegradation of catechol. Tyrosinase aggregates in Mag-SBA-15, prepared in a two step process of tyrosinase adsorption and crosslinking, could be used repeatedly for catechol degradation with no serious loss of enzyme activity. Considering these results of cleaning up water from toxic inorganic, organic and biochemical contaminants, magnetic mesoporous materials have a great potential to be employed for the removal of environmental contaminants and potentially for the application in large-scale wastewater treatment plants.

36 MATERIALS SCIENCE↗

Mechanism-Based Tumor-Targeting Drug Delivery System. Validation of Efficient Vitamin Receptor-Mediated Endocytosis and Drug Release

An efficient mechanism-based tumor-targeting drug delivery system, based on tumor-specific vitamin-receptor mediated endocytosis, has been developed. The tumor-targeting drug delivery system is a conjugate of a tumor-targeting molecule (biotin: vitamin H or vitamin B-7), a mechanism-based self-immolative linker and a second-generation taxoid (SB-T-1214) as the cytotoxic agent. This conjugate (1) is designed to be (i) specific to the vitamin receptors overexpressed on tumor cell surface and (ii) internalized efficiently through receptor-mediated endocytosis, followed by smooth drug release via glutathione-triggered self-immolation of the linker. In order to monitor and validate the sequence of events hypothesized, i.e., receptor-mediated endocytosis of the conjugate, drug release, and drug-binding to the target protein (microtubules), three fluorescent/fluorogenic molecular probes (2, 3, and 4) were designed and synthesized. The actual occurrence of these processes was unambiguously confirmed by means of confocal fluorescence microscopy (CFM) and flow cytometry using L1210FR leukemia cells, overexpressing biotin receptors. The molecular probe 4, bearing the taxoid linked to fluorescein, was also used to examine the cell specificity (i.e., efficacy of receptor-based cell targeting) for three cell lines, L1210FR (biotin receptors overexpressed), L1210 (biotin receptors not overexpressed), and WI38 (normal human lung fibroblast, biotin receptor negative). As anticipated, the molecular probe 4 exhibited high specificity only to L1210FR. To confirm the direct correlation between the cell-specific drug delivery and anticancer activity of the probe 4, its cytotoxicity against these three cell lines was also examined. The results clearly showed a good correlation between the two methods. In the same manner, excellent cell-specific cytotoxicity of the conjugate 1 (without fluorescein attachment to the taxoid) against the same three cell lines was confirmed. This mechanism-based tumor-targeting drug delivery system will find a range of applications.

59 BASIC BIOLOGICAL SCIENCES↗

Luminescence imaging of water during proton-beam irradiation for range estimation

Purpose: Proton therapy has the ability to selectively deliver a dose to the target tumor, so the dose distribution should be accurately measured by a precise and efficient method. The authors found that luminescence was emitted from water during proton irradiation and conjectured that this phenomenon could be used for estimating the dose distribution. Methods: To achieve more accurate dose distribution, the authors set water phantoms on a table with a spot scanning proton therapy system and measured the luminescence images of these phantoms with a high-sensitivity, cooled charge coupled device camera during proton-beam irradiation. The authors imaged the phantoms of pure water, fluorescein solution, and an acrylic block. Results: The luminescence images of water phantoms taken during proton-beam irradiation showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. Furthermore, the image of the pure-water phantom showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of the fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had a 14.5% shorter proton range than that of water; the proton range in the acrylic phantom generally matched the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 s. Conclusions: Luminescence imaging during proton-beam irradiation is promising as an effective method for range estimation in proton therapy.

60 APPLIED LIFE SCIENCES↗

EGS Collab Testbed 1: Second Set Tracer Test Results

The EGS Collab project is developing ~10-20 m-scale field sites where fracture stimulation and flow models can be validated against controlled, small-scale, in-situ experiments. The first multi-well experimental site was established at the 4850 level in the Homestake Mine in Lead, South Dakota, where hydraulic fractures were created at an injection well drilled sub-horizontal from the drift. This file contains the second set of tracer data (also include the data uploaded previously, https://gdr.openei.org/submissions/1128) for the EGS Collab testbed. The tracer tests were conducted during October 2018 - November 2019. Injected tracers include DNA, C-dots (fluorescein nano particles), fluorescein, rhodamine-b, sodium chloride, lithium bromide and cesium iodine. The tracers have been detected in three flowing wells located about 7.5 to 9 meters away from the injection interval. The tracer breakthrough curves from these locations have been adjusted to account for the residence time in the injection and production tubing. The details about the tracer test can be found in Background and Methods of Tracer Tests (Mattson et al. (2019,a,b)) (also included in this package). References Mattson, E.D., Neupane, G., Plummer, M.A., Hawkins, A., Zhang, Y. and the EGS Collab Team 2019a. Preliminary Collab fracture characterization results from flow and tracer testing efforts. In Proceedings 44th Workshop on Geothermal Reservoir Engineering, edited, Stanford University, Stanford, California. Mattson, E.D., Neupane, G., Hawkins, A., Burghardt, J., Ingraham, M., Plummer, M., and the EGS Collab Team, 2019b. Fracture tracer injection response to pressure perturbations at an injection well. GRC Transactions, Vol. 43, 2019. Neupane, Ghanashyam, Earl Mattson, Adam Hawkins, Mitchell Plummer, and Yuran Zhang. EGS Collab Testbed 1: Tracer data sets. No. 1128. DOE Geothermal Data Repository; Idaho National Laboratory, 2019.

15 GEOTHERMAL ENERGY↗

Coupling of Independent Electrochemical Reactions and Fluorescence at Closed Bipolar Interdigitated Electrode Arrays

Electrochemical reactions occurring at the opposite ends of bipolar electrodes (BPEs) are necessarily coupled, enabling electron transfer events at one end to be read out optically, for example, by coupling to fluorogenic reactions at the other end. In order to explore the potential of this technique for studying multiple redox events, arrays of parallel BPE interdigitated electrode arrays (IDEAs) were fabricated and integrated with separate analytical and reporter microfluidic channels, respectively, in a closed BPE configuration. The apparatus was initially evaluated employing Fe(CN) 6 3/4- in the analytical channel coupled to weakly emissive resazurin and strongly emissive resorufin as the fluorogenic redox reporter pair. We then used the device to investigate a proton-coupled electron transfer reaction, hydroquinone (QH 2 ) oxidation, in structures with an integrated pH modulation electrode (PME). A pH-sensitive dye, fluorescein, was co-introduced into the analytical channel to monitor PME modulation of solution pH, and its coupling to QH 2 oxidation, thereby permitting changes in solution pH, and consequently QH 2 oxidation rate, to be monitored directly in the analytical channel and compared to the fluorescence in the reporter channel. Additionally, diffusion of OH - generated at the PME produced a spatial pH profile that was visualized via fluorescein emission, and, because the oxidation of QH 2 at each BPE is strongly dependent on the local pH, via the coupled fluorogenic reaction at the opposite pole of the corresponding BPE digit in the reporter channel. Thus, BPE IDEAs support the coupling of independent redox reactions and the use of fluorescence imaging to explore a diverse set of spatially varying electrochemical phenomena realized in a variety of electrochemical geometries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On-demand in situ generation of oxygen in a nanofluidic embedded planar microband electrochemical reactor

In situ generation of reagents and their subsequent use downstream presents new opportunities to amplify the utility of nanofluidic devices by exploiting the confined geometry to address mass transport limitations on reaction kinetics and efficiency. Oxygen, an inherently valuable reactant, can be produced from electrolysis of water, a process that can be conveniently integrated within a nanofluidic system. Here, we construct and characterize a nanofluidic device consisting of a planar microband electrode embedded within a nanochannel for in situ electrochemical generation and optical monitoring of O 2 . Fluorescein, a dye with a pH-sensitive emission intensity, was used to monitor the spatiotemporal characteristics of the oxidation of H 2 O, using the co-produced H + . Application of anodic potentials at the nanochannel-embedded electrode results in a decrease in fluorescence intensity, which reflects the decreasing solution pH. A combination of fluorescence intensity and chronoamperometric response was used to quantitatively determine proton generation, and the H + /O 2 stoichiometry was then used to determine the concentration of the O 2 in the channel. Comparison of the experimental results to finite element simulations validates the use of fluorescein emission intensity to spectroscopically determine the local oxygen concentration in the nanochannel. By varying the applied potential, spatially averaged O 2 concentrations ranging from 0.13 to 0.41 mM were generated. In conclusion, the results demonstrate a convenient route to in situ modulation of the dissolved O 2 level in a nanofluidic device and the use of an optical probe to monitor its spatial and temporal distribution under flow conditions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Water-soluble drug partitioning and adsorption in HEMA/MAA hydrogels

Two-photon confocal microscopy and back extraction with UV/Vis-absorption spectrophotometry quantify equilibrium partition coefficients, k, for six prototypical drugs in five soft-contact-lens-material hydrogels over a range of water contents from 40 to 92%. Partition coefficients were obtained for acetazolamide, caffeine, hydrocortisone, Oregon Green 488, sodium fluorescein, and theophylline in 2-hydroxyethyl methacrylate/methacrylic acid (HEMA/MAA, pK a ≈ 5.2) copolymer hydrogels as functions of composition, aqueous pH (2 and 7.4), and salinity. At pH 2, the hydrogels are nonionic, whereas at pH 7.4, hydrogels are anionic due to MAA ionization. Solute adsorption on and nonspecific electrostatic interaction with the polymer matrix are pronounced. To express deviation from ideal partitioning, we define an enhancement or exclusion factor, E≡k/φ 1 , where φ 1 is hydrogel water volume fraction. All solutes exhibit E>1 in 100wt % HEMA hydrogels owing to strong specific adsorption to HEMA strands. For all solutes, E significantly decreases upon incorporation of anionic MAA into the hydrogel due to lack of adsorption onto charged MAA moieties. For dianionic sodium fluorescein and Oregon Green 488, and partially ionized monoanionic acetazolamide at pH 7.4, however, the decrease in E is more severe than that for similar-sized nonionic solutes. Conversely, at pH 2, E generally increases with addition of the nonionic MAA copolymer due to strong preferential adsorption to the uncharged carboxylic-acid group of MAA. For all cases, we quantitatively predict enhancement factors for the six drugs using only independently obtained parameters. In dilute solution for solute i , E i is conveniently expressed as a product of individual enhancement factors for size exclusion (E$_i^{ex}$), electrostatic interaction (E$_i^{el}$), and specific adsorption (E$_i^{ad}$):E$_i$≡E$_i^{ex}$E$_i^{el}$E$_i^{ad}$. Finally, to obtain the individual enhancement factors, we employ an extended Ogston mesh-size distribution for Eiex; Donnan equilibrium for E$_i^{el}$; and Henry's law characterizing specific adsorption to the polymer chains for E$_i^{ad}$. Predicted enhancement factors are in excellent agreement with experiment.

back extraction↗

Electron Mobility and Trapping in Ferrihydrite Nanoparticles

Iron is the most abundant transition metal in the Earth's crust, and naturally occurring iron oxide minerals play a commanding role in environmental redox reactions. Although iron oxide redox reactions are well studied, their precise mechanisms are not fully understood. Recent work has shown that these involve electron transfer pathways within the solid, suggesting that overall reaction rates could be dependent on electron mobility. Initial ultrafast spectroscopy studies of iron oxide nanoparticles sensitized by fluorescein derivatives supported a model for electron mobility based on polaronic hopping of electron charge carriers between iron sites, but the constitutive relationships between hopping mobilities and interfacial charge transfer processes has remained obscured. We developed a coarse-grained lattice Monte Carlo model to simulate the collective mobilities and lifetimes of these photoinjected electrons with respect to recombination with adsorbed dye molecules for the essential nanophase ferrihydrite, and tested predictions made by the simulations using pump-probe spectroscopy. We acquired optical transient absorption spectra as a function of particle size and under a variety of solution conditions, and used cryogenic transmission electron microscopy to determine the aggregation state of the nanoparticles. We observed biphasic electron recombination kinetics over timescales that spanned picoseconds to microseconds, the slower regime of which was fit with a stretched exponential decay function. The recombination rates were weakly affected by nanoparticle size and aggregation state, suspension pH, and the injection of multiple electrons per nanoparticle. We conclude that electron mobility indeed limits the rate of interfacial electron transfer in these systems with the slowest processes relating to escape from deep traps, the presence of which outweighs the influence of environmental factors such as pH-dependent surface charge.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Plexcitons: The Role of Oscillator Strengths and Spectral Widths in Determining Strong Coupling

Strong coupling interactions between plasmon and exciton-based excitations have been proposed to be useful in the design of optoelectronic systems. However, the role of various optical parameters dictating the plasmon-exciton (plexciton) interactions is less understood. Herein, we propose an inequality for achieving strong coupling between plasmons and excitons through appropriate variation of their oscillator strengths and spectral widths. These aspects are found to be consistent with experiments on two sets of free-standing plexcitonic systems obtained by (i) linking fluorescein isothiocyanate on Ag nanoparticles of varying sizes through silane coupling and (ii) electrostatic binding of cyanine dyes on polystyrenesulfonate-coated Au nanorods of varying aspect ratios. Being covalently linked on Ag nanoparticles, fluorescein isothiocyanate remains in monomeric state, and its high oscillator strength and narrow spectral width enable us to approach the strong coupling limit. In contrast, in the presence of polystyrenesulfonate, monomeric forms of cyanine dyes exist in equilibrium with their aggregates: Coupling is not observed for monomers and H-aggregates whose optical parameters are unfavorable. The large aggregation number, narrow spectral width, and extremely high oscillator strength of J-aggregates of cyanines permit effective delocalization of excitons along the linear assembly of chromophores, which in turn leads to efficient coupling with the plasmons. Further, the results obtained from experiments and theoretical models are jointly employed to describe the plexcitonic states, estimate the coupling strengths, and rationalize the dispersion curves. The experimental results and the theoretical analysis presented here portray a way forward to the rational design of plexcitonic systems attaining the strong coupling limits.

Thomas, Reshmi↗

One-electron redox kinetics of aqueous transition metal couples Zn 2+/+ , Co 2+/+ , and Ni 2+/+ using pulse radiolysis

The one-electron redox potentials for aqueous metal couples Co 2+/+ and Ni 2+/+ have been investigated by using pulse radiolysis using their reactions with a series of reference compounds to establish the most positive upper limits of E 0 . Experiments with Zn + were also carried out to confirm the characteristic shape of the expected reduction kinetics. Both formate ions and t-BuOH were employed to scavenge ˙OH radicals and ˙H atoms. Kinetics and fitted first and second order reaction rates have been reported for reactions with methyl viologen, fluorescein, Ru(NH 3 ) 6 3+ , Co(en) 3 2+ , Co(sepulcrate) 3+ , Ru(bpy) 3 2+ , Cr(bpy)33+, and Ni(Me 6 [14]4,11-dieneN4) 2+ . Previous work demonstrated that both Co 2+ and Ni 2+ can be reduced by CO 2 ˙- radicals, giving a negative E 0 limit of -1.9 V vs. SHE. A definite reaction of Ni + with fluorescein di-anions provides a new upper limit of the Ni 2+/+ couple as -0.906 V vs. SHE. The reaction of Co + with Ru(bpy) 3 2+ has been confirmed, giving E 0 = -1.3 V vs. SHE as a rigorous upper limit of the Co 2+/+ couple. In the case of Co 2+/+ , kinetics were complicated by a self-catalyzed metal clustering phenomenon. Initiation rate constants of this process have also been reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects on the Ocular Surface from Reading on Different Smartphone Screens: A Prospective Randomized Controlled Study

The purpose of this study was to investigate the influence of smartphone reading on the ocular surface and to compare the various effects of different screens and light conditions on the ocular surface. One hundred nineteen volunteers were randomly divided into: light + organic light‐emitting diode (OLED), light + electronic ink (eINK), dark + OLED, and dark + eINK. Ocular surface examinations, including noninvasive break‐up time (NIBUT), noninvasive keratograph tear meniscus height (NIKTMH), ocular redness, fluorescein break‐up time (FBUT), corneal fluorescein staining, meibomian gland assessment, Schirmer I Test, and blinking frequency, were performed before and after a reading task. Symptoms were evaluated using the Ocular Surface Disease Index (OSDI) and Computer Vision Syndrome Questionnaire (CVS‐Q). NIBUT and FBUT were decreased statistically significantly after participants read on an OLED screen for 2 hours compared with the baseline in light and dark environments, whereas no statistically significant decrease was observed on an eINK screen. NIKTMH was statistically significantly decreased after reading on an OLED screen in light and dark settings, and the eINK screen had a lesser effect on NIKTMH. An obvious increase in the ocular redness, OSDI and CVS‐Q scores was observed after reading on an OLED screen, whereas the eINK screen had a lesser effect on these indicators. Blink rate increased gradually in OLED subgroups during the reading task, whereas no statistically significant difference was observed in the eINK subgroups. Our research suggested that reading on an OLED screen can cause ocular surface disorder and obvious subjective discomfort, whereas reading on an eINK screen can minimize ocular surface disorder in both dark and light environments.

Yuan, Kelan↗

Fabrication of nanoporous membranes for tuning microbial interactions and biochemical reactions

Here we describe how new strategies for combining conventional photo- and soft- lithographic techniques with high-resolution patterning and etching strategies are needed in order to produce multi-scale fluidic platforms that address the full range of functional scales seen in complex biological and chemical systems. The smallest resolution required for an application often dictates the fabrication method used. Micromachining and micro-powder blasting yield higher throughput, but lack the resolution needed to fully address biological and chemical systems at the cellular and molecular scales. In contrast, techniques such as electron beam lithography or nanoimprinting allow nanoscale resolution, but are traditionally considered costly and slow. Other techniques such as photolithography or soft lithography have characteristics between these extremes. Combining these techniques to fabricate multi-scale or hybrid fluidics allows fundamental biological and chemical questions can be answered. In this study, a combination of photolithography and electron beam lithography are used to produce two multi-scale fluidic devices that incorporate porous membranes into complex fluidic networks to control the flow of energy, information, and materials in chemical form. In the first device, materials and energy were used to support chemical reactions. A nanoporous membrane fabricated with e-beam lithography separates two parallel, serpentine channels. Photolithography was used to write microfluidic channels around the membrane. The pores were written at 150nm and reduced in size with silicon dioxide deposition from plasma enhanced chemical vapor deposition (PECVD) and atomic layer deposition (ALD). Using this method, the molecular weight cutoff (MWCO) of the membrane can be adapted to the system of interest. In the second approach, photolithography was used to fabricate 200nm thin pores. The pores confined microbes and allowed energy replenishment from a media perfusion channel. The same device can be used for study of intercellular communication via the secretion and uptake of signal molecules. Pore size was tested with 750nm fluorescent polystyrene beads and fluorescein dye. The 200nm PDMS pores were shown to be robust enough to hold 750nm beads while under pressure, but allow fluorescein to diffuse across the barrier. Further testing showed that extended culture of bacteria within the chambers was possible. Finally, these two examples show how lithographically defined porous membranes can be adapted to two unique situations and used to tune the flow of chemical energy, materials, and information within a microfluidic network.

36 MATERIALS SCIENCE↗

MO-FG-CAMPUS-JeP1-03: Luminescence Imaging of Water During Proton Beam Irradiation for Range Estimation

Purpose: Since proton therapy has the ability to selectively deliver a dose to a target tumor, the dose distribution should be accurately measured. A precise and efficient method to evaluate the dose distribution is desired. We found that luminescence was emitted from water during proton irradiation and thought this phenomenon could be used for estimating the dose distribution. Methods: For this purpose, we placed water phantoms set on a table with a spot-scanning proton-therapy system, and luminescence images of these phantoms were measured with a high-sensitivity cooled charge coupled device (CCD) camera during proton-beam irradiation. We also conducted the imaging of phantoms of pure-water, fluorescein solution and acrylic block. We made three dimensional images from the projection data. Results: The luminescence images of water phantoms during the proton-beam irradiations showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. The image of the pure-water phantom also showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had 14.5% shorter proton range than that of water; the proton range in the acrylic phantom was relatively matched with the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 sec. Three dimensional images were successfully obtained which have more quantitative information. Conclusion: Luminescence imaging during proton-beam irradiation has the potential to be a new method for range estimations in proton therapy.

60 APPLIED LIFE SCIENCES↗

Fish scale-loss caused by simulated hydraulic shear stress

Riverine fishes found within streams impacted by hydropower also often pass through hydropower turbines during annual downstream migrations. During turbine passage events, fish may experience a suite of stressors including rapid pressure changes, impacts from turbine blades, and exposure to hydraulic shear. Scale-loss is often observed in fish collected below dams and hydraulic shear is the most likely cause of this trauma. While exposure to shear may cause other injuries, scale-loss appears to be the most common non-lethal injury observed to date. We sought to quantify how hydraulic shear may cause scale-loss in rainbow trout, gizzard shad, and hybrid striped bass by precisely controlling the exposure level (velocity) and duration (seconds) of a water jet. We targeted the same area for all three species found between the operculum and dorsal fin on the left, lateral surface. Exposure velocities ranged from 0 (controls) to 11.0 meters/second but fish were only exposed to the water jet for 1.5 seconds. A 0.2 milligram/milliliter solution of fluorescein was used to stain the areas of scale-loss by submerging each fish in this solution for at least 6 minutes. Fluorescein was used because it interacts with epithelial tissue that has been damaged and it fluoresces under ultraviolet lighting. Fish were photographed under short- and longwave ultraviolet lighting in a dark chamber to capture fluorescence. Fish photographs were analyzed using ImageJ and the proportion of descaled area was estimated for each fish within a 35 by 35-millimeter square. In general, these data highlight how exposure to hydraulic shear may lead to significant levels of descaling in riverine fishes.

13 HYDRO ENERGY↗

Late ophthalmological complications after total body irradiation in non-human primates

PURPOSE: To investigate the long-term effects of total body irradiation (TBI) on the incidence and time course of ocular complications. MATERIALS AND METHODS: Rhesus monkeys treated with TBI photon doses up to 8.5 Gy and proton doses up to 7.5 Gy were studied at intervals up to 25 years post-irradiation. They were compared with control groups with a similar age distribution. Cataract formation and ocular fundus lesions were scored according to a standardized protocol. Fluorescein angiography and histopathology was performed in selected animals. RESULTS: Cataract formation occurred after a latent period of 3-5 years. Significant cataract induction was observed for photon-doses of 8 and 8.5 Gy and beyond 20 years after proton irradiation. The severity of the lesions represents significant impairment of vision and would require cataract surgery if similar results occurred in human bone marrow transplant patients. Fluorescein angiography demonstrated a normal pattern of retinal vessels in 13 out of 14 animals (93%) from the irradiated group and in eight out of nine animals (89%) from the control group. No additional lesions apart from age-related degenerative changes could be demonstrated. Histological evaluation revealed no radiation-associated vasculopathy. CONCLUSIONS: Radiation alone for doses up to 8.5 Gy of photons does not carry a potential risk for fundus pathology, whereas clinically important cataract induction should be anticipated within 5 years after photon doses of 8.0 and 8.5 Gy and proton doses in excess of 2.5 Gy.

NASA Discipline Radiation Health↗

Sensitive detection of Escherichia coli O157:H7 in food and water by immunomagnetic separation and solid-phase laser cytometry

Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown E. coli O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and r2 = 0. 95 (n = 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and r2 = 0.98 (n = 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of E. coli O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.

Non-NASA Center↗