Analysis of silica fouling on nonwetting surfaces

Ground water sources used as coolant fluids in a variety of thermal systems such as heat exchangers and power plant condensers contain silica particles that accrete on heat transfer surfaces over time leading to reduction in thermal performance, a problem that is particularly exacerbated with temperature. Nonwetting superhydrophobic, lubricant-infused, and a new class of solid-infused surfaces introduced in this work are candidates for fouling mitigation, by virtue of their water repellency, but little is known about fouling of silica on the surfaces, especially under dynamic flow conditions and as a function of temperature. This article presents, for the first time, a systematic study of dynamic flow fouling of silica on nonwetting surfaces vis-à-vis conventional copper surface over a temperature range 20–50°C. The mechanism of silica aggregate formation and its adherence to the different surfaces is elucidated by scanning electron microscope (SEM) imaging. Sigmoidal growth model is used to describe the time evolution of fouling thermal resistance and an Arrhenius model is presented for the temperature-dependent increase in the asymptotic fouling resistance on nonwetting and conventional surfaces alike. Lubricant-infused and solid-infused surfaces are shown to reduce fouling thermal resistance by up to 25% and 13%, respectively, compared to a conventional surface, whereas superhydrophobic surfaces lose their non-wettability under flow conditions, leading to an adverse increase in the fouling resistance by up to 13%. Considering the possible lubricant depletion in lubricant-infused surfaces over prolonged exposure to a flowing fluid, solid-infused surfaces present a robust alternative.

42 ENGINEERING↗

Mitigating municipal solid waste fouling in biofuel conversion via screw surface modifications

Here, municipal solid waste (MSW)'s 40–60 % carbon content makes it a feedstock for biofuel production via pyrolysis. One challenge in the conversion process is MSW fouling due to thermal decomposition. The accumulated deposit on the injection screw often leads to plugging and constriction. This study examined the morphology and composition of the MSW fouling deposit and conducted a thermal simulation to understand the temperature gradience of the injection screw. Surface modifications including smoothening and anti-adhesion coating were proposed for the injection screw to address the deposit problem. For evaluating the candidate mitigations, a bench-scale fouling test was developed with the gas environment, temperature, and sliding speed relevant to the contact interface between the MSW particles and the screw. Results suggested that a smoother screw surface could reduce the grip and a non-metallic coating with a lower surface energy could decrease adhesion, consequently leading to less fouling. Specifically, reducing the roughness from 2 to 0.6 and then to 0.2 μm proportionally decreased the amount of deposit, and the diamond-like-carbon, CrN, and NiCr–CrC composite coatings effectively hindered the fouling process. This study provides fundamental insights into the MSW fouling and proof-of-concept of potential mitigations through the screw surface modification.

09 BIOMASS FUELS↗

Comparative analysis of various pretreatments to mitigate fouling and scaling in membrane distillation

Membrane distillation (MD) has shown strong promise for treating hypersaline produced water (PW) streams. Scaling and fouling on the membrane surface, however, have been identified as major challenges for commercialization and widespread application. The focus of this study was to first identify the nature of foulants and scalants on the membrane surface and then investigate the pretreatment strategies that mitigate the extent of fouling and scaling on the membrane surface. Vacuum MD (VMD) was selected for this study because of its higher flux at more moderate feed temperatures that eventually leads better assessment of fouling and scaling on the membrane surface. VMD flux tests were carried out with three different real PW samples at total dissolved solids concentrations in the range of 120-160 g/L. It was found that an efficient pretreatment prior to MD is required to mitigate the fouling potential of the organic matter, mostly suspended constituents, in PW samples. Suspended organics fouled and quickly wetted the MD membrane. Major conventional treatments, including filtration, oxidation, coagulation, air floatation, and aeration were investigated to pretreat the PW before VMD tests. A comprehensive comparative analysis is presented showing that the ultrafiltration and coagulation pretreatments displayed the best performance in mitigating the fouling and scaling, while oxidative pretreatment was found to be effective in reducing the iron concentration to less than 5 ppm. The surface of scaled membranes was carefully characterized to further evaluate the performance of each pretreatment. The components that had the highest tendency to precipitate on the membrane surface were identified as strontium sulfate, calcium carbonate, sodium chloride, iron oxide, and silica. In closing, these findings are supported by thermodynamic estimation of the saturation index.

42 ENGINEERING↗

Analysis of fouling mechanism in ultrafiltration of produced water

Flux decline measurements provided insight into the fouling behavior of ultrafiltration (UF) membranes for produced water (PW) treatment. Three UF membranes were compared in terms of the rate and the intensity of fouling. The flux decline analysis showed the fouling transition from blocking mechanisms (i.e., complete and intermediate blocking as well as standard blocking) to cake formation occurs earlier for more permeable membranes. Lower trans-membrane pressure (TMP) of 0.1 bar led to particle accumulation on the membrane surface leading to cake formation as the predominant fouling mechanism. In higher TMP experiments, standard and intermediate blocking followed by cake formation were found to be apparent fouling mechanisms. Overall, for the membranes with higher permeabilities and for the filtrations with pre-filtered feed, faster transition to cake formation was observed primarily due to crowd out effect. By understanding membrane fouling and behavior, it is possible to mitigate performance losses in membrane-based technologies that could be used for the treatment of PW. Furthermore, this study provides information to identify blocking rate and intensity in various conditions for UF membranes when treating PW.

42 ENGINEERING↗

Performance Restoration of Iron Electrodes by Polarity Reversal after Long-Term Surface Fouling in Wastewater Electrocoagulation

Iron electrocoagulation (Fe-EC) performance often declines with time, producing lower contaminant removal efficiencies and higher energy requirements due to formation of a fouling layer on the electrodes. Here, we investigate the formation of the fouling layer and the effectiveness of polarity reversal to restore the Fe-EC performance. A thin, porous iron oxide layer initially forms on the anode, thickening into a dense, over 150-μm thick crystalline layer after extended operation. This fouling layer restricts dissolution and diffusion of Fe ions into the bulk solution, thus increasing the anode potential required to maintain a desired electrical current and decreasing Faradaic efficiency. Polarity reversal applied when performance decline is observed effectively removes the fouling layer, thereby restoring Faradaic and contaminant removal efficiencies and decreasing energy consumption. Our findings suggest that gas generation at the cathode surface after polarity reversal causes removal of the fouling layer. This study enhances the current understanding of fouling-layer formation in Fe-EC and offers a practical approach, involving polarity reversal, to maintain electrode reactivity and optimal Fe-EC performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fouling resistance prediction using artificial neural network nonlinear auto-regressive with exogenous input model based on operating conditions and fluid properties correlations

Fouling in a heat exchanger in Crude Preheat Train (CPT) refinery is an unsolved problem that reduces the plant efficiency, increases fuel consumption and CO{sub 2} emission. The fouling resistance behavior is very complex. It is difficult to develop a model using first principle equation to predict the fouling resistance due to different operating conditions and different crude blends. In this paper, Artificial Neural Networks (ANN) MultiLayer Perceptron (MLP) with input structure using Nonlinear Auto-Regressive with eXogenous (NARX) is utilized to build the fouling resistance model in shell and tube heat exchanger (STHX). The input data of the model are flow rates and temperatures of the streams of the heat exchanger, physical properties of product and crude blend data. This model serves as a predicting tool to optimize operating conditions and preventive maintenance of STHX. The results show that the model can capture the complexity of fouling characteristics in heat exchanger due to thermodynamic conditions and variations in crude oil properties (blends). It was found that the Root Mean Square Error (RMSE) are suitable to capture the nonlinearity and complexity of the STHX fouling resistance during phases of training and validation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temperature-dependent dynamic fouling on superhydrophobic and slippery nonwetting copper surfaces

Bioinspired, superhydrophobic and slippery liquid infused surfaces that offer nonwetting characteristics have been explored in recent years for fouling mitigation. However, most of the studies are in the context of biofouling or under static immersion at ambient temperature conditions that are not reflective of the dynamic flow environment in practice. This article presents, for the first time, a systematic study of dynamic fouling of superhydrophobic (SHS) and slippery lubricant-infused surfaces (LIS) over a range of flow and temperature conditions. In this work, copper metallic surfaces were textured via electrodeposition or etching and further functionalized to achieve SHS and, additionally, infiltrated with a lubricant to fabricate LIS. The nonwetting surfaces were studied for their fouling behavior in a rotating Couette flow of a supersaturated calcium sulfate solution at different rotational speed and temperature. Fouling mineral mass accumulation on the different surfaces was measured as a function of time over a period of days using inductively coupled plasma mass spectroscopy and the fouled surfaces were investigated using scanning electron microscopy. Both SHS and LIS showed superior anti-scaling performance at all ranges of variables. An analytical Hill-Langmuir model is presented, for the first time, to describe the time evolution of scaling within 20% accuracy over the range of parameters studied. The study is the first to juxtapose two surface texturing methods, electrodeposition and etching, and two nonwetting surface types, SHS and LIS, subject to a common suite of experiments to elucidate fundamental understanding of mineral fouling on nonwetting surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fouling modeling and prediction approach for heat exchangers using deep learning

In this article, we develop a generalized and scalable statistical model for accurate prediction of fouling resistance using commonly measured parameters of industrial heat exchangers. This prediction model is based on deep learning where a scalable algorithmic architecture learns non-linear functional relationships between a set of target and predictor variables from large number of training samples. Here, the efficacy of this modeling approach is demonstrated for predicting fouling in an analytically modeled cross-flow heat exchanger, designed for waste heat recovery from flue-gas using room temperature water. The performance results of the trained models demonstrate that the mean absolute prediction errors are under 10 –4 KW –1 for flue-gas side, water side and overall fouling resistances. The coefficients of determination (R 2 ), which characterize the goodness of fit between the predictions and observed data, are over 99%. Even under varying levels of measurement noise in the inputs, we demonstrate that predictions over an ensemble of multiple neural networks achieves better accuracy and robustness to noise. We find that the proposed deep-learning fouling prediction framework learns to follow heat exchanger flow and heat transfer physics, which we confirm using locally interpretable model agnostic explanations around randomly selected operating points. Overall, we provide a robust algorithmic framework for fouling prediction that can be generalized and scaled to various types of industrial heat exchangers.

42 ENGINEERING↗

Fouling mechanism in airblast atomizers and its suppression for water desalination

A detailed experimental study is presented on fouling behavior of the anti-clogging perforated plate atomizer designed for high salinity applications, and compared with a conventional (plain-jet) airblast atomizer. Low-pressure regions around fast moving air in the outer layer of spray (as in conventional atomizers: plain-jet and prefilming) due to Venturi suction were identified as the root cause of atomizer clogging, as they facilitate salt accumulation on the atomizer surface from spray. Accordingly, severe atomizer fouling, and fluctuations in spray cone angle were observed in the conventional airblast atomizer over 2 h at 100°C air and 50°C saline (44° to 76° at 35,000 ppm, and 44° to 91° at 100,000 ppm). In this regard, the perforated plate atomizer provides a novel liquid-film airblast atomization by maintaining a liquid-annulus film (around the air outlet) as the outer layer of spray. Doing so we achieved nearly complete suppression of fouling, and spray cone angle fluctuations (28° ± 1° at 35,000 ppm, and 30° ± 1° at 100,000 ppm). Later, novel liquid-film atomization was adopted in the conventional airblast atomizer. While, the conventional airblast atomization needed atomizer cleaning/maintenance after 35 min for 175°C air and 65°C saline at 100,000 ppm, the liquid-film atomization showed no sign of fouling over 14 h. Hence, current work establishes a benchmark liquid-film airblast atomization mechanism in the anti-clogging perforated plate atomizer for complete suppression of fouling in airblast atomization. Furthermore, this extends the application of airblast atomizers from high evaporation jet engines to ZLD-HDH desalination systems, spraying, powder metallurgy, pharmaceuticals and hospitals, and spray drying and cooling.

42 ENGINEERING↗

Fouling characterization and treatment of water reuse concentrate with membrane distillation: Do organics really matter

Membrane distillation (MD) for the treatment of concentrated brines has been limited in part by membrane fouling, resulting in subsequent flux decline and membrane wetting. This study provides new insight into the identification of fouling and scaling mechanisms and pretreatment strategies for mitigating flux decline with MD treatment of water reuse reverse osmosis concentrate (ROC). Bench-scale direct contact MD experiments were performed with untreated and pretreated ROC. Biological activated carbon (BAC), chemical water softening, or fluidized bed crystallization reactor coupled with ion exchange (FBCR-IX) were selected as pretreatment strategies to isolate the effects of organic fouling and calcium scaling. Organic and inorganic compounds were analyzed by high-performance liquid chromatography (HPLC) and inductively coupled plasma mass spectrometry (ICP-MS). Calcium ions were found to be the major contributor to flux decline despite the high organic content in the ROC. Minimal organic fouling is likely because the organic matter in the ROC is hydrophilic, limiting hydrophobic-hydrophobic interactions between the organics and the membrane. Furthermore, the water flux declined by 63 % after removing organic compounds by BAC pretreatment, with 60 % of the calcium mass precipitating from the solution. Whereas, the water flux remained constant after removing multivalent ions with fluidized bed crystallization. Cleaning the membrane by acid washing and temperature reversal recovered 73 % and 12 % of the water flux, respectively. The analyses outlined in this study can assist in selecting appropriate fouling and scaling mitigation strategies for water reuse ROC and a wide range of feed solutions used in MD applications.

42 ENGINEERING↗

Drawing on Membrane Photocatalysis for Fouling Mitigation

Photocatalysis is an effective and environmentally friendly approach for degrading organic pollutants, particularly in scenarios where sunlight can be utilized as the energy source. Opportunities are emerging to apply materials and methods from photocatalytic pollutant degradation to address the challenge of fouling. Membrane fouling, attributed to organic foulants, is a prevalent problem for all membrane-based technologies and represents a major deleterious impact on membrane performance. Integration of tactics developed in photocatalysis more broadly to membranes reveals new strategies for membrane fouling control-an approach taken by an increasing number of researchers. Furthermore, this review summarizes key developments in photocatalytic materials and methods in water treatment and presents recent progress in the development of processes for photocatalytic alleviation of membrane fouling, including photocatalyst design and modification strategies aimed at enhancing photocatalytic efficiency, as well as different configurations of photocatalysis-membrane systems (PMS). Perspectives on future research and development opportunities for photocatalytic membrane fouling control are also provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exhaust Gas Recirculation Cooler Fouling in Diesel Applications: Fundamental Studies Deposit Properties and Microstructure

This paper reports on the results of experimental efforts aimed at improving the understanding of the mechanisms and conditions at play in the fouling of EGR coolers. An experimental apparatus was constructed to utilize simplified surrogate heat exchanger tubes in lieu of full-size heat exchangers. The use of these surrogate tubes allowed removal of the tubes after exposure to engine exhaust for study of the deposit layer and its properties. The exhaust used for fouling the surrogate tubes was produced using a modern medium-duty diesel engine fueled with both ultra-low sulfur diesel and biodiesel blends. At long exposure times, no significant difference in the fouling rate was observed between fuel types and HC levels. Surface coatings for the tubes were also evaluated to determine their impact on deposit growth. No surface treatment or coating produced a reduction in the fouling rate or any evidence of deposit removal. In addition, microstructural analysis of the fouling layers was performed using optical and electron microscopy in order to better understand the deposition mechanism. The experimental results are consistent with thermophoretic deposition for deposit formation, and van der Waals attraction between the deposit surface and exhaust-borne particulate.

EGR↗

Flux Recovery of a Forward Osmosis Membrane After a Fouling Process

Wastewater treatment through Forward Osmosis (FO) membranes is a process that has been evaluated in the past years as an innovative technology for the Next Generation Life Support Systems. FO technologies are cost effective, and require very low energy consumption, but are subject to membrane fouling. Membrane fouling occurs when unwanted materials accumulate on the active side of the membrane during the wastewater treatment process, which leads to a decrease in membrane flow rates. Membrane fouling can be reversed with the use of antifoulant solutions. The aim of this study is to identify the materials that cause flow rate reduction due to membrane fouling, as well as to evaluate the flux recovery after membrane treatment using commercially available antifoulants. 3D Laser Scanning Microscope images were taken to observe the surface of the membrane. Fourier Transform Infrared (FTIR) spectrometry results identified possible compounds that cause membrane fouling and FO testing results demonstrated flow rate recovery after membrane treatment using antifoulants.

Forward osmosis↗

Experimental Investigation of Polymer-Induced Fouling of Heater Tubes in the First-Ever Polymer Flood on Alaska North Slope Part II

A polymer flood pilot has been ongoing in the Schrader Bluff viscous oil reservoir at Milne Point on the Alaska North Slope. The results from the pilot are encouraging. However, a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This work applies a multiexperimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids to determine safe operating conditions. Dynamic scale loop (DSL) tests were conducted to study fouling due to polymer at different skin temperatures (165–350°F) in a dynamic state of fluid flow where the fluids’ flow mimics the residence time of fluids in the heat exchanger of the field pilot. Static deposit tests were also conducted at similar skin temperatures of 165–250°F using a novel experimental apparatus designed and built in-house. It was found that at higher skin temperatures of 250–350°F, tube blocking was observed in the DSL tests, whereas the tests at 165–200°F did not show any tube blocking, even in a more extended test period. The deposit test showed that the deposit rate generally increases with skin temperature, and the presence of polymer aggravates the fouling. The copper tube performs best when the skin temperatures are 165–200°F, while the stainless steel tube performs best at a skin temperature of 250°F. These experiments also manifested the influence of the cloudpoint of the solution as the deposit rate increased significantly when the skin temperature was higher than the solution cloudpoint. The study provides a source of practical guidance to the field operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2-Aminoimidazole reduces fouling and improves membrane performance

Biofouling is difficult to control and hinders the performance of membranes in all applications but is of particular concern when natural waters are purified. Fouling, via multiple mechanisms (organic-only, biofouling-only, cell-deposition-only, and organic + biofouling), of a commercially available membrane (control) and a corresponding membrane coated with an anti-biofouling 2-aminoimidazole (2-AI membrane) was monitored and characterized during the purification of a natural water. Results show that the amount of bacterial cell deposition and organic fouling was not significantly different between control and 2-AI membranes; however, biofilm formation, concurrent or not with other fouling mechanisms, was significantly inhibited (95–98%, p < 0.001) by the 2-AI membrane. The limited biofilm that formed on the 2-AI membrane was weaker (as indicated by the polysaccharide to protein ratio) and thus presumably easier to remove. The conductivity rejection by the 2-AI and control membranes was not significantly different throughout the 75-h experiments, but the rejection of dissolved organic carbon by biofouled (biofouling-only, cell-deposition-only, and organic + biofouling) 2-AI membranes was statistically higher (10–12%, p = 0.003–0.07). When biofouled, the water permeance of the 2-AI membranes decreased significantly less (p < 0.05) over 75 hours than that of the control membranes, whether or not other additional types of fouling occurred concurrently. Despite the initially lower water permeances of 2-AI membranes (11% lower on average than controls), the 2-AI membranes outperformed the controls (10–11% higher average water permeance) after biofilm formation occurred. Overall, 2-AI membranes fouled less than controls without detriment to water productivity and solute rejection.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling and mitigating fouling of microfiltration membranes for microalgae dewatering

Dewatering is energy-intensive for microalgae production, and microfiltration (MF) membranes are attractive because of their high energy efficiency. However, the membranes suffer from fouling by organic matter in the algae solutions, and there needs fundamental understanding of membrane fouling with actual algae solutions. Herein we thoroughly evaluate the dewatering performance of commercial polyethersulfone (PES) MF membranes using an integrated experiment and modeling approach. The effect of algae concentration, testing time, feed flow rate, and chemical cleaning on the dewatering performance and fouling-layer morphology are investigated. The fouling behavior can be successfully described using the Hermia and gel layer models with a gel concentration of 48 g/L for algae solutions. Furthermore, the PES membrane surface was grafted with hydrophilic zwitterions, which mitigated the fouling. For example, when challenged with 10 g/L algae solution in dead-end cells, the pristine and modified membrane exhibit water permeance of 80 and 170 L m – 2 h –1 bar –1 , respectively. Finally, three cycles of dewatering and NaOH cleaning were performed to demonstrate the promise of the MF membranes for practical dewatering application.

42 ENGINEERING↗

Probe Measures Fouling As In Heat Exchangers

Combustion deposits reduce transfer of heat. Instrument measures fouling like that on gas side of heat exchanger in direct-fired boiler or heat-recovery system. Heat-flux probe includes tube with embedded meter in outer shell. Combustion gases flow over probe, and fouling accumulates on it, just as fouling would on heat exchanger. Embedded heat-flow meter is sandwich structure in which thin Chromel layers and middle alloy form thermopile. Users determine when fouling approaches unacceptable levels so they schedule cleaning and avoid decreased transfer of heat and increased drop in pressure fouling causes. Avoids cost of premature, unnecessary maintenance.

Marner, Wilbur J.↗

An Alternating, Current-Induced Electromagnetic Field for Membrane Fouling and Scaling Control during Desalination of Secondary Effluent from Municipal Wastewater

Membrane treatment of secondary effluent for reuse applications is a promising approach to expand water supplies and provide flexibility to water resources management. However, effective control of membrane fouling and scaling is crucial for cost-effective treatment and system resilience. This study compared the performance of antiscalants to an alternating, current-induced electromagnetic field (EMF) as an alternative pretreatment method to reverse osmosis. Compared to the no-EMF control experiments, the EMF device resulted in 13% higher water recovery and 366% lower flux decline at 60% of water recovery, along with 2–8 times lower precipitation of fouling and scaling, as evidenced by scanning electron microscope, energy dispersive X-ray spectroscopy, and chemical extraction analysis. The combination of the EMF with antiscalant was more effective for reducing membrane fouling and scaling, increasing water recoveries up to 89.3%, as compared to the EMF (67.5%) and antiscalant-only (73.6%) configurations. This is the first study to demonstrate synergistic effects of using an EMF in combination with antiscalants and could lead to lower pretreatment costs. Additional research is required to quantify the economics of this approach and to fully understand the fundamental mechanisms governing fouling and scaling control by an EMF.