Search NASA⌕ Search

SEARCH · Search NASA

Results for “FRAMING CAMERA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A time-resolved, in-chamber x-ray pinhole imager for Z

We have commissioned a new time-resolved, x-ray imaging diagnostic for the Z facility. The primary intended application is for diagnosing the stagnation behavior of Magnetized Liner Inertial Fusion (MagLIF) and similar targets. We have a variety of imaging systems at Z, both time-integrated and time-resolved, that provide valuable x-ray imaging information, but no system at Z up to this time provides a combined high-resolution imaging with multi-frame time resolution; this new diagnostic, called TRICXI for Time Resolved In-Chamber X-ray Imager, is meant to provide time-resolved spatial imaging with high resolution. The multi-frame camera consists of a microchannel plate camera. A key component to achieving the design goals is to place the instrument inside the Z vacuum chamber within 2 m of the load, which necessitates a considerable amount of x-ray shielding as well as a specially designed, independent vacuum system. Here, a demonstration of the imaging capability for a series of MagLIF shots is presented. Predictions are given for resolution and relative image irradiance to guide experimenters in choosing the desired configuration for their experiments.

47 OTHER INSTRUMENTATION↗

Experiments on plasma arcs at a water–air interface

An exploding water plasma experiment at UCLA investigated the expansion and morphology of a fireball with and without an external magnetic field. Diagnostics include photographs and movies (which may be downloaded) acquired with a framing camera, magnetic probes, and visible light spectra. The expansion and internal magnetic fields are very different from the unmagnetized case when a magnetic field of order 300G is applied along the expansion axis. Visible light spectra are brighter and additional lines are seen in the presence of the magnetic field. The experiment can serve as a platform for studies of interfacial mixing and possibly shed light on very different processes such as laser target physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray imaging of Rayleigh–Taylor instabilities using Fresnel zone plate at the National Ignition Facility

Being able to provide high-resolution x-ray radiography is crucial in order to study hydrodynamic instabilities in the high-energy density regime at the National Ignition Facility (NIF). Current capabilities limit us to about 20 μm resolution using pinholes, but recent studies have demonstrated the high-resolution capability of the Fresnel zone plate optics at the NIF, measuring 2.3 μm resolution. Using a zinc Heα line at 9 keV as a backlighter, we obtained a radiograph of Rayleigh–Taylor instabilities with a measured resolution of under 3 μm. Two images were taken with a time integrated detector and were time gated by a laser pulse duration of 600 ps, and a third image was taken with a framing camera with a 100 ps time gate on the same shot and on the same line of sight. The limiting factors on image quality for these two cases are the motion blur and the signal to noise ratio, respectively. We also suggest solutions to increase the image quality.

Do, A. (ORCID:0000000174372147)↗

Diagnosing low-mode (ℓ < 6) and mid-mode (6 ≤ ℓ ≤ 60) asymmetries in the post-stagnation phase of laser-direct-drive deuterium–tritium cryogenic implosions on OMEGA

Low- and mid-mode perturbations are possible candidates for performance limitations in cryogenic direct-drive implosions on the OMEGA laser at the Laboratory of Laser Energetics. Simulations with a 3D hydrocode demonstrated that hotspot imagers do not show evidence of the shell breakup in the dense fuel. However, these same simulations revealed that the low- and mid-mode perturbations in the dense fuel could be diagnosed more easily in the post-stagnation phase of the implosion by analyzing the peak in the x-ray emission limb at the coronal–fuel interface than before or at the stagnation phase. In experiments, the asymmetries are inferred from gated images of the x-ray emission of the implosion by using a 16-pinhole array imager filtered to record x-ray energies >800 eV and an x-ray framing camera with 40-ps time integration and 20-μm spatial resolution. Furthermore, a modal analysis is applied to the spatial distribution of the x-ray emission from deuterium and tritium cryogenic implosions on OMEGA recorded after the bang time to diagnose the low- and mid-mode asymmetries, and to study the effect that the beam-to-target ratio (Rb/Rt) has on the shell integrity.

47 OTHER INSTRUMENTATION↗

Dynamics of implosion, bounce, and re-implosion of a shell directly driven by a time-shaped laser pulse

Gas-filled plastic spherical shells have been imploded using the 60-beam OMEGA laser. The same laser pulse was used as in a previous experiment, which demonstrated the dynamic formation of a shell by irradiating a homogeneous plastic foam sphere. In the present experiment, the shell initially implodes, bounces, and expands; a new shell then forms and undergoes a second implosion. Analysis of x-ray self-emission-streaked images and sequences of 2D x-ray self-emission framing camera images show shell evolution that is in reasonable agreement with 1D simulations. Shell integrity and symmetry are well maintained until the formation of the new shell. The final implosion, instead, is affected by substantial asymmetries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle balance of deuterium during deuterium shattered pellet injection shutdown in DIII-D

A particle balance analysis was conducted during a deuterium (D 2 ) shattered pellet injection-induced plasma shutdown on the DIII-D tokamak to determine why less than 20% of the pellet material is assimilated into the core plasma by the mid-current quench (CQ). Initially, most of the D 2 is injected as frozen shards and ionized upon entering the vessel. During the thermal quench, ionized particles move to the divertors and subsequently to the center post (CP) walls, where they rapidly recycle and partially accumulate as neutrals without assimilating into the core plasma. In contrast, the particle flux to the outer midplane walls is negligible, despite being accompanied by hot plasma with electron temperatures exceeding 100 eV. During mid-CQ, volume recombination effects, although not large enough to impact overall particle balance, were significant enough to require accounting for accurate interpretation of fast-framing camera D-alpha signals and the estimation of the CP wall particle flux. In addition, toroidal asymmetries, observed in measurements of toroidal electron density perturbations and the phase of magnetohydrodynamic modes, are present throughout the shutdown and can account for a discrepancy in the assimilation rate for up to 50% of the observed D 2 particle inventory. These sources and sinks of particles and fluxes were identified using absolutely calibrated D-alpha brightness and Langmuir probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiframe X-ray diffraction on the OMEGA EP laser

A method of measuring multiple temporally resolved powder x-ray diffraction measurements during a single dynamic compression laser experiment has been demonstrated on the OMEGA EP laser. Up to four time-gated snapshots of the x-ray diffraction pattern are collected on an ultrafast x-ray framing camera with a 2θ scattering angle coverage of 48°–65° and 400-ps temporal resolution with the potential for 10°–160° and 200-ps resolution. X-ray diffraction snapshots capture the transformation to a high-pressure β phase in ramp-compressed Zr, constraining the atomic structure and pressure–density equation-of-state in a single shot. Here, this platform will be used to constrain transition pressures, understand the role of kinetics, and verify the existence of hysteresis and metastability on phase transformations at the lattice level under single-shot dynamic compression.

47 OTHER INSTRUMENTATION↗

Study of the electrothermal and MHD instabilities in exploding cylindrical foil liner

Abstract An experimental and numerical study of the plasma instabilities in an electrical exploding cylindrical Al liner is reported. The Al liner 3 mm in diameter and 10 μ m in thickness is exploded at the Qin-1 facility (450 ns, 400 kA). Various diagnostics, such as multi-frame laser shadowgraphy, an x-ray framing camera, and an x-ray backlighting system are developed. The different imaging systems are sensitive to plasma of different areal densities based on the comparison between the experiments and simulation, which reveal the dynamics of the exploding liner in more detail. The laser shadow images show the low-density plasma (∼1–2 × 10 −4 g cm −2 ) at the edge of the liner, and both the amplitude and wavelength of the plasma instabilities increase over time, which are considered to be magnetohydrodynamic (MHD) instabilities rather than electrothermal instabilities. During the ablation of the liner, quasi-periodic azimuthally correlated striations are directly observed in extreme ultraviolet (EUV) self-emission images. Meanwhile, the vertical filaments, which are electrothermal instabilities for plasma under the condition of ∂ η /∂ T < 0, are also observed in EUV self-emission images. The x-ray backlighting images of the exploding liner are obtained by placing an X -pinch load on the current-return path to serve as an x-ray point source (∼1 ns, ∼10 μ m). The x-ray backlighting results show the behavior of the high-density plasma (∼1.89 × 10 −3 g cm −2 ), which includes the transition from electrothermal to MHD instabilities. Finally, we realized a 2D MHD simulation of the exploding liner under experimental conditions, which shows good agreement with the results of the experimental perturbation.

Physics↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

System Calibration Including Time Delay Estimation for GNSS/INS-Assisted Pushbroom Scanners Onboard UAV Platforms

Unmanned aerial vehicles (UAVs ) equipped with imaging sensors and integrated global navigation satellite system/inertial navigation system (GNSS/INS ) units are used for numerous applications. Deriving reliable 3D coordinates from such UAVs is contingent on accurate geometric calibration, which encompasses the estimation of mounting parameters and synchronization errors. Through a rigorous impact analysis of such systematic errors, this article proposes a direct approach for spatial and temporal calibration (estimating system parameters through a bundle adjustment procedure) of a GNSS/INS -assisted pushbroom scanner onboard a UAV platform. The calibration results show that the horizontal and vertical accuracies are within the ground sampling distance of the sensor. Unlike for frame camera systems, this article also shows that the indirect approach is not a feasible solution for pushbroom scanners due to their limited ability for decoupling system parameters. This finding provides further support that the direct approach is recommended for spatial and temporal calibration of UAV pushbroom scanner systems.

47 OTHER INSTRUMENTATION↗

Detectors and diagnostics for multiprobe radiography using high-energy short-pulse lasers

Multiprobe radiography requires the following diagnostic capabilities at minimum: radiographic source diagnostics, spectroscopy, imaging, and tomography diagnostics. Depending on the repetition rate of the radiation sources, the diagnostics may be a single-shot diagnostic, such as photographic (radiochromic and X-ray films for high energy photons) films, or a multiple-shot diagnostic for repetitive source operations, such as a high-speed framing camera. Due to the drastically different detector physics of electrons, photons at different energies (keV to 10s of MeV in the radiography context), heavy ions such as protons, alphas, and neutrons, see, for example, Ref. [1, 2] for an overview, different types or configurations of detectors and constructions may be required for multiprobe radiography applications. Some of the common detector metricsinclude, independent of the particle/photon species, sensitivities or efficiency, energy resolution, spatial or temporal resolutions and others. Some unique detection scenarios arise in a multiprobe radiography setting, for example, crosstalk mitigation and particle identification (ID) when X-ray and higher energy photons, relativistic electrons, neutrons, other hadrons, and heavy particles coexist at the detector location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mapping of Benthic Habitats at Marine Renewable Energy Sites Using Multibeam Echosounder and Sediment Profile Imaging Technologies

Objectives/Scope: The goal of this work was to develop a consistent and semi-automated seafloor survey method for generating high-resolution, benthic habitat maps for environmental assessments and monitoring of marine renewable energy sites. Sediment profile and plan view imaging (SPI/PV) technology was combined with multibeam bathymetry and acoustic backscatter methods to demonstrate a rapid, cost-effective benthic mapping protocol. A key technical innovation of this project was the development of an image processing platform that automatically measures key features from the images. Methods: Multibeam echosounder (MBES) acoustic and SPI/PV surveys were conducted at three coastal areas off the U.S. west coast, including the PacWave South energy test site off of Newport, Oregon. Point data on physical and biological sediment conditions obtained from the SPI/PV imagery were used to efficiently ground-truth the high-resolution MBES bathymetry and backscatter mosaics. The SPI camera is an optical corer that obtains an undisturbed 21 by 15 cm, high-resolution, cross-sectional image of the sediment–water interface and upper sediment column. The plan view camera attached to the SPI camera frame captures a downward looking view of the seabed immediately before the SPI image is obtained. As part of this project, we developed a computer vision image processing platform (iSPI) that uses deep convolutional neural networks and other approaches to automatically identify and measure key features in the images, such as grain size and surface relief. Results: Detailed benthic habitat maps were generated using this mapping approach for three different marine settings. The sites mapped included a silt-dominated embayment; a sloping, nearshore, transitional very fine to coarse sand bottom; and a medium, sand-dominated continental shelf marine energy test site. In each case, acoustic and imaging surveys were completed in less than week, and detailed benthic habitat maps were generated within 60 days. The results were placed within the Coastal and Marine Ecological Classification Standard (CMECS) habitat mapping framework, and various combinations of the bathymetry, backscatter, and SPI and PV data were used to generate CMECS component maps. Novel Information: This project developed and demonstrated a repeatable and cost-effective approach for efficiently mapping benthic habitat conditions over broad areas of the seafloor by combining state-of-the-art acoustic and imaging techniques. The primary survey tools used in this project have been used previously in both the offshore renewable (wind) and oil and gas sectors to map and monitor benthic environments. This project’s innovations include 1) the focused use of high-resolution SPI/PV imagery to ground-truth acoustic mosaics, and 2) the development of a computer automated image analysis processing tool that both streamlines and standardizes the generation of data from the imagery and makes the data extraction process more cost-effective and repeatable.

13 HYDRO ENERGY↗

High speed two-dimensional imaging with an analog interface

A quantitative pulse count (event detection) algorithm with linearity to high count rates is accomplished by combining a high-speed, high frame rate camera with simple logic code run on a massively parallel processor such as a GPU. The parallel processor elements examine frames from the camera pixel by pixel to find and tag events or count pulses. The tagged events are combined to form a combined quantitative event image.

Waugh, Justin↗

High speed two-dimensional event detection and imaging using an analog interface and a massively parallel processor

A quantitative pulse count (event detection) algorithm with linearity to high count rates is accomplished by combining a high-speed, high frame rate camera with simple logic code run on a massively parallel processor such as a GPU or a FPGA. The parallel processor elements examine frames from the camera pixel by pixel to find and tag events or count pulses. The tagged events are combined to form a combined quantitative event image.

Waugh, Justin↗

Continuous-wave planar laser induced fluorescence with a fast camera

We present planar, laser induced fluorescence (PLIF) measurements of the velocity-resolved distribution function of ions in a plasma using a modulated, narrow linewidth, continuous-wave laser. Plasma emission is acquired with a high frame rate camera, and the laser light is spread into a thin sheet so that an entire plane of the plasma is imaged at each interrogation wavelength. Fourier analysis is conducted on each pixel of the images to separate the modulated fluorescent emission from the background light. Argon ion temperatures and bulk flow maps are reported in a helicon plasma source, and standard single-point LIF measurements provide validation of the PLIF measurement.

47 OTHER INSTRUMENTATION↗

Integrated photonic encoder for low power and high-speed image processing

Abstract Modern lens designs are capable of resolving greater than 10 gigapixels, while advances in camera frame-rate and hyperspectral imaging have made data acquisition rates of Terapixel/second a real possibility. The main bottlenecks preventing such high data-rate systems are power consumption and data storage. In this work, we show that analog photonic encoders could address this challenge, enabling high-speed image compression using orders-of-magnitude lower power than digital electronics. Our approach relies on a silicon-photonics front-end to compress raw image data, foregoing energy-intensive image conditioning and reducing data storage requirements. The compression scheme uses a passive disordered photonic structure to perform kernel-type random projections of the raw image data with minimal power consumption and low latency. A back-end neural network can then reconstruct the original images with structural similarity exceeding 90%. This scheme has the potential to process data streams exceeding Terapixel/second using less than 100 fJ/pixel, providing a path to ultra-high-resolution data and image acquisition systems.

47 OTHER INSTRUMENTATION↗

Classification of computed thermal tomography images with deep learning convolutional neural network

Thermal tomography (TT) is a computational method for the reconstruction of depth profile of the internal material defects from Pulsed Infrared Thermography (PIT) nondestructive evaluation. Here, the PIT method consists of recording material surface temperature transients with a fast frame infrared camera, following thermal pulse deposition on the material surface with a flashlamp and heat diffusion into material bulk. TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of the subsurface internal defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to the heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify the size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. The performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shapes imported from scanning electron microscopy images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on the TT images of elliptical defects is capable of classifying the shape and orientation of irregular defects.

42 ENGINEERING↗