Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY CONVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Angular phase-matching bandwidths in biaxial nonlinear crystals for frequency converters

It is shown that the angular phase-matching bandwidths in biaxial nonlinear crystals in the general case must be calculated in the coordinate system in which the angular deviations of the crystal and the laser beam divergence are determined consistently. The angular phase-matching bandwidths in this coordinate system may considerably differ from the conventionally determined values. The optimum orientation of the coordinate system for determining the angular phase-matching bandwidths is found. It is established that, in the general case in biaxial crystals, as in uniaxial ones, phase matching is always angle-critical along one coordinate and noncritical along the other and that it is possible to realise angle-noncritical phase matching of the fourth order. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling and analyzing parasitic parameters in high frequency converters

This research focuses on electromagnetic interference (EMI) / electromagnetic compatibility (EMC) design and analysis in power electronics systems. To limit the EMI under the standards, different methods and strategies are investigated. Parasitic parameters of high frequency (HF) transformer are analyzed using a novel analytical method, finite element method (FEM), and experimental measurements for different structures and windings arrangements. Also, the magnetic field, electric field, electric displacement, and electric potential distribution are simulated and analyzed. Moreover, a high voltage system is considered and analyzed to improve the EMC. The EMI propagation paths are analyzed. The EMI noise level of the system is obtained and compared to the IEC61800-3 standard. To improve the EMC, the parasitic parameters of the transformer, as the main path of EMI circulation, are analyzed and optimized to block the propagation. Furthermore, the geometry structure of the HF transformer is optimized to lower the parasitics in the system. Three pareto-optimal techniques are investigated for the optimization. The models and results are verified by 3D-FEM and experimental results for several given scenarios. Furthermore, the EMC modeling and conducted EMI analysis are developed for a system including an AC-DC-DC power supply (rectifier and dual active bridge (DAB) converter). Moreover, the common mode (CM) EMI noise propagation through the system is discussed and the noise sources and effect of components on the noise are analyzed. Additionally, the CM impedance of different parts of the system and the noise levels are discussed. Finally, EMI attenuation techniques were applied to the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic characteristics of an orthogonal turbine and output-control systems for TPP with high-voltage frequency converter

A mathematical description of a closed control system with allowance for pressure fluctuations in the head system, which makes it possible to analyze the regime stability of orthogonal generating sets at tidal electric power plants when operating in the complete range of heads, outputs, and rotational speeds, and to select parameters of the control system, is obtained for an orthogonal hydroturbine and a generator with a load regulator.

16 TIDAL AND WAVE POWER↗

Total Ionizing Dose Test of Analog Devices’ AD654 Voltage to Frequency Converter

Analog Devices’ AD654 was tested for total ionizing dose (TID) response beginning on February 13, 2017. This device has the Radiation Effects and Analysis Group Identification (REAG ID) number 16-036. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

B. Freeman↗

Frequency to Analog Converter

Frequency to analog converters with unipolar field effect transistor for determining potential charge by pulse duration of input signal

Hagihara, F. S.↗

Semiconductor millimeter and centimeter wave radiometer for the study of the radiation of an underlying surface

A theoretical and experimental investigation of a superheterodyne radiometer system with input frequency converter and intermediate frequency modulation is presented. Conditions are found, at which the temperature sensitivity of the device does not deteriorate. A sensitivity function to external parameters (temperature, heterodyne power) of a radiometer system with intermediate frequency modulation and a Schottky diode frequency converter is presented and calculated. Use of a frequency converter at the second harmonic of the heterodyne permitted simplication of the radiometer design and the use of a semiconductor heterodyne. A 3 cm range intermediate frequency amplifier permitted the use of centimeter wave radiometer signals. Fluctuation sensitivity of radiometers with a 1 sec time constant is 0.3 K at 3.4 mm and 0.06 K at 3 cm.

Bordonskiy, G. S.↗

Fast-response frequency-to-analog converter

Frequency-to-analog converter has a fast response time and a low ripple. The circuit uses a frequency-to-pulse converter which provides two pulse trains, both at the same frequency as that of the input signal, but with a 10 microsecond difference between the trains.

Hagihara, F. S.↗

Electrical performance characteristics of high power converters for space power applications

The first goal of this project was to investigate various converters that would be suitable for processing electric power derived from a nuclear reactor. The implementation is indicated of a 20 kHz system that includes a source converter, a ballast converter, and a fixed frequency converter for generating the 20 kHz output. This system can be converted to dc simply by removing the fixed frequency converter. This present study emphasized the design and testing of the source and ballast converters. A push-pull current-fed (PPCF) design was selected for the source converter, and a 2.7 kW version of this was implemented using three 900 watt modules in parallel. The characteristic equation for two converters in parallel was derived, but this analysis did not yield any experimental methods for measuring relative stability. The three source modules were first tested individually and then in parallel as a 2.7 kW system. All tests proved to be satisfactory; the system was stable; efficiency and regulation were acceptable; and the system was fault tolerant. The design of a ballast-load converter, which was operated as a shunt regulator, was investigated. The proposed power circuit is suitable for use with BJTs because proportional base drive is easily implemented. A control circuit which minimizes switching frequency ripple and automatically bypasses a faulty shunt section was developed. A nonlinear state-space-averaged model of the shunt regulator was developed and shown to produce an accurate incremental (small-signal) dynamic model, even though the usual state-space-averaging assumptions were not met. The nonlinear model was also shown to be useful for large-signal dynamic simulation using PSpice.

Stuart, Thomas A.↗

High-frequency matrix converter with square wave input

A device for producing an alternating current output voltage from a high-frequency, square-wave input voltage comprising, high-frequency, square-wave input a matrix converter and a control system. The matrix converter comprises a plurality of electrical switches. The high-frequency input and the matrix converter are electrically connected to each other. The control system is connected to each switch of the matrix converter. The control system is electrically connected to the input of the matrix converter. The control system is configured to operate each electrical switch of the matrix converter converting a high-frequency, square-wave input voltage across the first input port of the matrix converter and the second input port of the matrix converter to an alternating current output voltage at the output of the matrix converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ferroresonant flux coupled battery charger

A battery charger for incorporation into an electric-powered vehicle is disclosed. The charger includes a ferroresonant voltage-regulating circuit for providing an output voltage proportional to the frequency of an input AC voltage. A high frequency converter converts a DC voltage supplied, for example, from a rectifier connected to a standard AC outlet, to a controlled frequency AC voltage which is supplied to the input of the ferroresonant circuit. The ferroresonant circuit includes an output, a saturable core transformer connected across the output, and a first linear inductor and a capacitor connected in series across the saturable core transformer and tuned to resonate at the third harmonic of the AC voltage from the high frequency converter. The ferroresonant circuit further includes a second linear inductor connected between the input of the ferroresonant circuit and the saturable core transformer. The output voltage from the ferroresonant circuit is rectified and applied across a pair of output terminals adapted to be connected to the battery to be charged. A feedback circuit compares the voltage across the output terminals with a reference voltage and controls the frequency of the AC voltage produced by the high frequency converter to maintain the voltage across the output terminals at a predetermined value. The second linear inductor provides a highly reactive load in the event of a fault across the output terminals to render the charger short-circuit proof.

McLyman, Colonel W. T.↗

Physical Approaches to Designing a Two-Cascade Terahertz Laser Generating Difference-Frequency Radiation in a Nonlinear Optical ZnGeP{sub 2} Crystal

An optical layout of a two-cascade frequency converter of the mid-IR laser radiation into the terahertz (THz) radiation is proposed. In the first stage it is assumed to convert the Tm:YLF-laser frequency in a Cr{sup +2}:ZnSe polycrystal into the radiation with the wavelength ~2–3 μm. The second cascade can be presented as a parametric conversion of the frequencies of two laser sources operating in the ~2–3 μm range into the THz radiation via the difference-frequency mixing in a nonlinear optical ZnGeP{sub 2} crystal. The estimates of the terahertz output signal are reported.

47 OTHER INSTRUMENTATION↗

MEMS terahertz-to-infrared band converter using frequency selective planar metamaterial

A MEMS terahertz-to-infrared converter has been developed based on the unique properties of metamaterials that allow for selective control of the absorptivity and emissivity of the sensors. The converter consists of a sensing element structurally made of planar metamaterial membranes, connected to a substrate frame by four symmetrically-located thermal insulators. Upon THz absorption, the temperature of the sensing element increases and the outward infrared flux from the backside of the element is read by a commercial long-wave infrared camera. Two configurations were designed and fabricated with metamaterial absorptivity optimized for 3.8THz and 4.75THz quantum cascade lasers. The first sensor, fabricated with an oxidized aluminum backside, exhibits higher responsivity, but lower conversion efficiency than the second sensor, fabricated with a metamaterial backside. The spectral characteristics of the metamaterial on the two sides can be optimized to improve both responsivity and sensitivity, while keeping the sensors’ thermal time constant sufficiently small for real time imaging. No dedicated electronics or optics are required for readout making metamaterial-based MEMS THz-to-IR converters very attractive for THz imaging as means of a simple attachment to commercial IR cameras.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wireless Infrared Data Link

Infrared transmitter and receiver designed for wireless transmission of information on measured physical quantity (for example, temperature) from transducer device to remote-acquisition system. In transmitter, output of transducer amplified and shifted with respect to bias or reference level, then fed to voltage-to-frequency converter to control frequency of repetition of current pulses applied to infrared-light-emitting diode. In receiver, frequency of repetition of pulses converted back into voltage indicative of temperature or other measured quantity. Potential applications include logging data while drilling for oil, transmitting measurements from rotors in machines without using slip rings, remote monitoring of temperatures and pressures in hazardous locations, and remote continuous monitoring of temperatures and blood pressures in medical patients, who thus remain mobile.

Roth, Timothy E.↗

Parametric interaction of optical waves in metamaterials under low-frequency pumping

The influence of phase effects under three-wave parametric interaction and low-frequency pumping in metamaterials is studied in the case of a negative refractive index at a signal-wave frequency. It is found that the efficiency of the backward signal-wave amplification is the higher, the greater the ratio of the intensities of the idler and signal waves at the input to the metamaterial. An increase in the idler wave intensity at the input by five times, as compared to the signal-wave intensity, leads to a nonlinear increase in the signal-wave amplification by almost 20 times. According to the analytic expressions obtained in the constant-intensity approximation, the choice of the optimal parameters for the pump intensity, total length of the metamaterial and phase detuning will facilitate the implementation of regimes of effective amplification and generation of the signal wave. A comparison is made with the results obtained in the constant-field approximation, and a numerical estimate of the expected efficiency of the frequency conversion is presented. Control of frequency and pump power is shown to make possible the smooth tuning of the parametric converter frequency. The developed method can be used to design frequency converters based on nonlinear metamaterials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗