Search NASASearch

SEARCH · Search NASA

Results for “FREQUENCY MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Line-frequency measurements and analysis of N2O between 900 and 4700/cm

The N2O infrared spectrum from 900 to 4700/cm has been studied with a high-resolution Fourier-transform spectrometer. Measurements were made of line frequencies of several N2O isotopes for several ground-state and hot bands. These bands include the 1530-0330, 2330-0330, 0441-0440, 0441-0330, 0531-0330, and 1331-0330 bands of (N-14)2(O-16). Also, perturbation-enhanced transitions in the 0710-0110 and 0730-0110 bands were assigned and measured. The frequencies have been analyzed to obtain a unique set of effective vibration-rotation parameters for each vibrational state. The results obtained from this research are of high accuracy for the ground-state, and the first-excited-state bands of (N-14)2(O-16), in which the computed frequencies derived from the least-squares fits, are known to an absolute uncertainty of only +/-4 x 10 exp -5 for nonperturbed transitions.

Toth, Robert A.

A modular multiple use system for precise time and frequency measurement and distribution

A modular CAMAC based system is described which was developed to meet a variety of precise time and frequency measurement and distribution needs. The system was based on a generalization of the dual mixer concept. By using a 16 channel 100 ns event clock, the system can intercompare the phase of 16 frequency standards with subpicosecond resolution. The system has a noise floor of 26 fs and a long term stability on the order of 1 ps or better. The system also used a digitally controlled crystal oscillator in a control loop to provide an offsettable 5 MHz output with subpicosecond phase tracking capability. A detailed description of the system is given including theory of operation and performance. A method to improve the performance of the dual mixer technique is discussed when phase balancing of the two input ports cannot be accomplished.

Reinhardt, V. S.

Apparatus for using a time interval counter to measure frequency stability

An apparatus for measuring the relative stability of two signals is disclosed comprising a means for mixing the two signals down to a beat note sine wave and for producing a beat note square wave whose upcrossings are the same as the sine wave. A source of reference frequency is supplied to a clock divider and interval counter to synchronize them and to generate a picket fence for providing a time reference grid of period shorter than the beat period. An interval counter is employed to make a preliminary measurement between successive upcrossings of the beat note square wave for providing an approximate time interval therebetween as a reference. The beat note square wave and the picket fence are then provided to the interval counter to provide an output consisting of the time difference between the upcrossing of each beat note square wave cycle and the next picket fence pulse such that the counter is ready for each upcrossing and dead time is avoided. A computer containing an algorithm for calculating the exact times of the beat note upcrossings then computes the upcrossing times.

Greenhall, Charles A.

Time and frequency measuring metrological equipment in the USSR

The complex of the means of providing time and frequency traceability in the USSR includes the system of time and frequency standards of the National Time and Frequency Calibration Service, time and frequency transfer facilities and local time and frequency standards. Control on measurement correctness is performed by the All-Union State Standard calibration service. The hardware of most of the above-mentioned systems is provided by the instruments developed by our institute. A common scientific and technological approach allowed us to create a unified system of time-frequency equipment composed of widely used serial instruments, sets, automated systems and complexes. Primary frequency standards of different classes, time and frequency references and instruments are based on the unified system. CH1-70 hydrogen frequency standard and its CH1-70A, CH1-80 modifications are used in the group time and frequency standards. Measuring time and data processing techniques, and also instrumentation specifications on the results of 10-year operation are given. The existing system provides time-frequency measurements with 2 times 10(exp -13) plus or minus 1 times 10(exp -14) accuracy.

Uljanov, Adolph A.

Pressure broadening of ClO by N2 and O2 near 204 and 649 GHz and new frequency measurements between 632 and 725 GHz

The N2 and O2 pressure broadening of the ClO transitions near 204 and 649 GHz have been measured between 200 and 300 K. Oxygen broadening has been measured for the transitions near 278 GHz. The accuracy of the derived air broadening is comparable to that for the air broadening of stable species and is estimated to be within approximately 3% over the entire temperature range. These transitions are currently being used for satellite, balloon, and ground based monitoring of atmospheric ClO, respectively. Some new frequency measurements are reported in the 632 - 725 GHz range. These are in good agreement with previous measurements and predictions.

Oh, J. J.

Convergence of oscillator spectral estimators for counted-frequency measurements.

A common intermediary connecting frequency-noise calibration or testing of an oscillator to useful applications is the spectral density of the frequency-deviating process. In attempting to turn test data into predicts of performance characteristics, one is naturally led to estimation of statistical values by sample-mean and sample-variance techniques. However, sample means and sample variances themselves are statistical quantities that do not necessarily converge (in the mean-square sense) to actual ensemble-average means and variances, except perhaps for excessively large sample sizes. This is especially true for the flicker noise component of oscillators. This article shows, for the various types of noises found in oscillators, how sample averages converge (or do not converge) to their statistical counterparts. The convergence rate is shown to be the same for all oscillators of a given spectral type.

Tausworthe, R. C.

Absorption of sound in air - High-frequency measurements

The absorption of sound in air at frequencies from 4 to 100 kHz in 1/12 octave intervals, for temperatures from 255.4 K (0 F) to 310.9 K (100 F) in 5.5 K (10 F) intervals, and at 10% relative-humidity increments between 0% and saturation has been measured. The values of free-field absorption have been analyzed to determine the relaxation frequency of oxygen for each of the 92 combinations of temperature and relative humidity studied and the results are compared to an empirical expression. The relaxation frequencies of oxygen have been analyzed to determine the microscopic energy-transfer rates.

Bass, H. E.

Spline function approximation for velocimeter Doppler frequency measurement

A spline function approximation approach for measuring the Doppler spectral peak frequency in a laser Doppler velocimeter system is presented. The processor is designed for signal bursts with mean Doppler shift frequencies up to 100 MHz, input turbulence up to 20 percent, and photon counts as low as 300. The frequency-domain processor uses a bank of digital bandpass filters for the capture of the energy spectrum of each signal burst. The average values of the filter output energies, as a function of normalized frequency, are modeled as deterministic spline functions which are linearly weighted to evaluate the spectral peak location associated with the Doppler shift. The weighting coefficients are chosen to minimize the mean square error. Performance evaluation by simulation yields average errors in estimating mean Doppler frequencies within 0.5 percent for poor signal-to-noise conditions associated with a low photon count of 300 photons/burst.

Savakis, Andreas E.

Measuring Frequency Instability Of A Large Antenna

Frequency instability of antenna under test determined from measurement of phase deviation between outputs of two antennas. Fiber-optic system used to minimize spurious component of frequency instability contributed by propagation of signal from reference antenna to Allan-variance-measuring instrument. Intended primarily to reveal contributions of wind and air-temperature effects on antenna and beam-waveguide structures to overall frequency instabilities of received signals. Technique simpler, less expensive, potentially capable of providing instability data in shorter measuring times, and more precise.

Otoshi, Tom Y.