Search NASA⌕ Search

SEARCH · Search NASA

Results for “FT VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Split Isobaric Analog State in Ni 55 : Case of Strong Isospin Mixing

Study of βþ decay of the exotic T z = -3=2 nucleus 55 Cu, via delayed γ rays, has revealed a strongly isospin mixed doublet (4599–4579 keV) in 55 Ni, which represents the fragmented and previously unknown isobaric analog of the ground state of 55 Cu. The observed small log $ft$ values to both states in the doublet confirm the superallowed Fermi β decay. The near degeneracy of a pair of 3/2 - levels in 55Ni results in the strong isospin mixing. The isospin mixing matrix element between the T = 3/2 and T = 1/2 levels is inferred from the experiment to be 9(1) keV, which agrees well with the matrix element of the charge symmetry breaking shell model Hamiltonian of Ormand and Brown. A precise value of the half-life of 55 Cu at 57(3) ms was also obtained.

74 ATOMIC AND MOLECULAR PHYSICS↗

β Decay of 61 V and its Role in Cooling Accreted Neutron Star Crusts

The interpretation of observations of cooling neutron star crusts in quasipersistent x-ray transients is affected by predictions of the strength of neutrino cooling via crust Urca processes. The strength of crust Urca neutrino cooling depends sensitively on the electron-capture and β -decay ground-state-to-ground-state transition strengths of neutron-rich rare isotopes. Nuclei with a mass number of A = 61 are predicted to be among the most abundant in accreted crusts, and the last remaining experimentally undetermined ground-state-to-ground-state transition strength was the β decay of 61 V. This Letter reports the first experimental determination of this transition strength, a ground-state branching of $8.1^{+4.0}_{- 3.1}%$, corresponding to a log ft value of $5.5^{+0.2}_{-0.2}$. This result was achieved through the measurement of the β -delayed γ rays using the total absorption spectrometer SuN and the measurement of the β -delayed neutron branch using the neutron long counter system NERO at the National Superconducting Cyclotron Laboratory at Michigan State University. This method helps to mitigate the impact of the pandemonium effect in extremely neutron-rich nuclei on experimental results. The result implies that A = 61 nuclei do not provide the strongest cooling in accreted neutron star crusts as expected by some predictions, but that their cooling is still larger compared to most other mass numbers. Finally, only nuclei with mass numbers 31, 33, and 55 are predicted to be cooling more strongly. However, the theoretical predictions for the transition strengths of these nuclei are not consistently accurate enough to draw conclusions on crust cooling. With the experimental approach developed in this work, all relevant transitions are within reach to be studied in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision Tests of the Electroweak Interaction using Trapped Atoms and Ions

The objective of the proposed research is to study fundamental aspects of the electroweak interaction via precision measurements in beta decay to test our current understanding of fundamental particles and forces as contained in the so-called "Standard Model" of particle physics. By comparing elegant experiments to rigorous theoretical predictions, we will either confirm the Standard Model to a higher degree and rule out models which seek to extend it, or find evidence of new physics and help guide theorists in developing the New Standard Model. The use of ion and neutral atom traps at radioactive ion beam facilities has opened up a new vista in precision low-energy nuclear physics experiments. Traps provide an ideal source of decaying atoms: they can be extremely cold (~1 mK); they are compact (~1 mm^3); and perhaps most importantly, the daughter particles escape with negligible distortions to their momenta in a scattering-free, open environment. The project is taking advantage of these technologies and applying them to precision beta-decay studies at radioactive beam facilities. The program consists of two complementary efforts: 1) Ion traps are an extremely versatile tool for purifying, cooling and bunching low-energy beams of short-lived nuclei. A large-bore (210~mm) superconducting 7-Tesla solenoid is at the heart of a Penning trap system for which there is a dedicated beamline at T-REX, the upgraded radioactive beam facility at the Cyclotron Institute, Texas A&M University. In addition to providing a general-purpose decay station, the flagship program for this system is measuring the ft-values and beta-neutrino correlation parameters from isospin T=2 superallowed beta-delayed proton decays, complimenting and expanding the already strong program in fundamental interactions at the Institute. 2) A magneto-optical trap is being used at the TRIUMF Neutral Atom Trap facility to observe the (un)polarized angular distribution parameters of isotopes of potassium. We are able to highly polarize laser-cooled atoms and observe their decay with unprecedented precision. The correlation of the daughter beta particle with the initial nuclear spin as well as other correlations are sensitive to physics beyond the Standard Model. Both of these cutting-edge and exciting research efforts will test our understanding of the fundamental symmetries underlying our current theory of electroweak interactions. Complementary to high-energy collider experiments, these low-energy nuclear physics "table-top" experiments will search for new particles and interactions which are not already described by the Standard Model of particle physics. The value of this research is recognized to be cross-disciplinary, exciting and potentially revolutionary in our understanding of nature's fundamental interactions. Accordingly, it has been endorsed by the recent (2007) Nuclear Science Advisory Committee's Long Range Plan as part of their recommendation for a "New Standard Model Initiative." In addition to the near-term benefits of scholarly publications and visibility through description of this work at international conferences, an important benefit of this research program is the training of new, young and enthusiastic nuclear physicists. Participants in this demanding and rewarding field develop a very strong background in physics with experience in a range of its subfields since we use atomic techniques and apply them to a nuclear physics experiment which in the end tests the theories of high-energy physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of Free-Flight Laminar, Transitional, and Turbulent Heat-Transfer Results at Free-Stream Mach Numbers Near 20 (Reentry F)

Laminar, transitional, and turbulent heat-transfer data were measured during a reentry flight at a Mach number of 20 on a 5 deg half-angle cone 3.962 m (13 ft) long with an initial nose tip radius of 0.254 cm (0.1 in.). The free-stream Reynolds number increased during the prime data period from 7.0 x 10(exp 6) to 51.5 x 10(exp 6) per meter (2.1 x 10(exp 6) to 15.7 x 10(exp 6) per foot) and the ratio of wall to total temperature varied from 0.053 to 0.12. The angle of attack was less than 1deg for the prime data period. The experimental laminar and turbulent heating rates are compared with results from existing flat-plate prediction methods. At conditions of minimal tip blunting and angle of attack (above 26.8 km (88 000 ft)), values from a flat-plate laminar method agreed within 20 percent with the laminar data. The Schultz-Grunow skin-friction equation with reference enthalpy; conditions, with the Reynolds number based on distance from the transition location, and with the Colburn Reynolds analogy agreed within 10 percent with the experimental turbuleiit heating data. The Van Driest n skin-friction equation with Reynolds number greater than 10(exp 7) based on distance from the peak heating point and the Colburn Reynolds analogy was also within approximately 10 percent of the experimental turbulent heating data. A data correlation jbf the extent of transition and a simple empirical transition-zone heating correlation were also presented.

Zoby, Ernest V.↗

NTF model concept for the X-29A. Part 1: Requirements, guidelines, and design loads

A few Charpy samples containing a transverse EB weld at the V-notch location were produced. Three tensile specimens containing a transverse weld were also produced. These samples were tested at cryogenic temperatures. The welded Charpy samples resulted in average impact values of 20 ft-lb. This average value is as good as the NASA test samples with the base metal. The tensile specimens broke at slightly higher loads than had been calculated. The Charpy specimens did not come up to the prescribed level of 25 ft-lb. The results of the specimen tests are presented.

Daforno, G.↗

Vandenberg Air Force Base Upper Level Wind Launch Weather Constraints

The 30th Operational Support Squadron Weather Flight (30 OSSWF) provides comprehensive weather services to the space program at Vandenberg Air Force Base (VAFB) in California. One of their responsibilities is to monitor upper-level winds to ensure safe launch operations of the Minuteman III ballistic missile. The 30 OSSWF tasked the Applied Meteorology Unit (AMU) to analyze VAFB sounding data with the goal of determining the probability of violating (PoV) their upper-level thresholds for wind speed and shear constraints specific to this launch vehicle, and to develop a tool that will calculate the PoV of each constraint on the day of launch. In order to calculate the probability of exceeding each constraint, the AMU collected and analyzed historical data from VAFB. The historical sounding data were retrieved from the National Oceanic and Atmospheric Administration Earth System Research Laboratory archive for the years 1994-2011 and then stratified into four sub-seasons: January-March, April-June, July-September, and October-December. The maximum wind speed and 1000-ft shear values for each sounding in each subseason were determined. To accurately calculate the PoV, the AMU determined the theoretical distributions that best fit the maximum wind speed and maximum shear datasets. Ultimately it was discovered that the maximum wind speeds follow a Gaussian distribution while the maximum shear values follow a lognormal distribution. These results were applied when calculating the averages and standard deviations needed for the historical and real-time PoV calculations. In addition to the requirements outlined in the original task plan, the AMU also included forecast sounding data from the Rapid Refresh model. This information provides further insight for the launch weather officers (LWOs) when determining if a wind constraint violation will occur over the next few hours on day of launch. The interactive graphical user interface (GUI) for this project was developed in Microsoft Excel using Visual Basic for Applications. The GUI displays the critical sounding data easily and quickly for the LWOs on day of launch. This tool will replace the existing one used by the 30 OSSWF, assist the LWOs in determining the probability of exceeding specific wind threshold values, and help to improve the overall upper winds forecast for the launch customer.

Shafer, Jaclyn A.↗

H-Canyon Jumper Gasket Sealing Evaluation

H-Canyon Documented Safety Analysis approved December 2019 credits the leak integrity of HCanyon (HCA) process tanks, piping, and jumpers in preventing the release of radioactive material in a post seismic environment. Demonstration of leak tightness capability for this equipment was achieved through substantial analytical effort. However, one potential weak point that affects leak integrity exists at the gasketed joint between Hanford Connectors (HC) and nozzles. Review of the HCA Crane Log over a three-year period indicates the HCs periodically leak. Savannah River National Laboratory (SRNL) was requested to perform gasket compression tests that evaluate gasket relaxation characteristics, i.e., creep, and provide improvements to the HC installation process that can reduce or eliminate the frequency of leaks at HCs. A HC torque value of 312 ft-lbf is the target value used because it is the minimum torque value, with 95% confidence, when an unlubricated HC is impacted for standard sealing period of 9 seconds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

H-Canyon Jumper Gasket Sealing Evaluation

H-Canyon Documented Safety Analysis approved December 2019 credits the leak integrity of H-Canyon (HCA) process tanks, piping, and jumpers in preventing the release of radioactive material in a post seismic environment. Demonstration of leak tightness capability for this equipment was achieved through substantial analytical effort. However, one potential weak point that affects leak integrity exists at the gasketed joint between Hanford Connectors (HC) and nozzles. Review of the HCA Crane Log over a three-year period indicates the HCs periodically leak. Savannah River National Laboratory (SRNL) was requested to perform gasket compression tests that evaluate gasket relaxation characteristics, i.e., creep, and provide improvements to the HC installation process that can reduce or eliminate the frequency of leaks at HCs. A HC torque value of 312 ft-lbf is the target value used because it is the minimum torque value, with 95% confidence, when an unlubricated HC is impacted for standard sealing period of 9 seconds. In the HCA pipe-jumper connections are installed remotely by using HCs. HCs inherently add to the uncertainty of a gasketed joint because a calibrated torque value cannot be applied. The gasket material is a special material made of asbestos-fiber impregnated with Teflon. This material has been used for decades and generally performs well but does leak intermittently as gaskets creep and preloaded torque is lost. Gasket types are either snap-ring (SR) or lampshade (LS). Both gasket types cover the same seating area. The SR gasket is designed to remain with the jumper when the jumper is removed leaving the nozzle faces clean of any debris. SR gaskets are initially installed when the jumper is fabricated. Changing gaskets is time consuming and the radioactive environment presents risks to personnel. When jumpers are removed LS gaskets could be used to better seal the connection to reduce down time and ALARA concerns. That is, an LS gasket would be remotely positioned over the nozzle and the HC reinstalled. Testing also included two situations not typical of plant operation. One situation was the use of the non-standard double-layered gaskets (DG), and the other situation was the use of a LS without removal of the installed SR gasket. The DG was used when the supply of LS gaskets ended, so that testing could continue. It was of interest to demonstrate this gasket’s creep response because the DG, which was two gaskets glued together, was thicker than the LS gasket and the thicker material was expected to elicit a greater creep characteristics. The second situation of using two gaskets together by installing an LS gasket without removing the installed gasket is not allowed by the ASME Codes. However, by demonstrating the creep history of such a gasket arrangement it could be considered as an option that could possibly seal a connection while significantly reducing operational down time and personnel risk. Forty tests were conducted, and the overall results demonstrate the initial applied force and how the gasket changes with time. The change in sealing force, in terms of torque, was then measured to obtain a force history as the gaskets creep. This report documents the results of those tests as well as the method used to perform the tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Statistical analyses of reservoir and fracturing parameters for a multifractured shale oil reservoir in Mississippi

The use of multifractured horizontal wells has improved the efficiency of hydrocarbon extraction from shale gas and oil plays. It is highly desirable to estimate the characteristics of the reservoir and well fracturing through production data analysis. Production rate transient data from 16 wells in the Mississippi sections were analyzed to estimate local reservoir permeability and hydraulic fracture parameters. Key factors affecting well productivity have been identified for optimizing future well completion. Based on the theory of distance of investigation during transient linear flow, the reservoir matrix permeability of TMS was estimated to be between 53 nd and 210 nd, averaging at 116 nd. The matrix permeability follows the lognormal distribution and is considered homogeneous according to the coefficient of variation. The fracture half-length was estimated using the matrix permeability data from the rate transient analysis. The fracture half-length was found to have a mean value of 234 ft with a standard deviation of 66 ft in a normal distribution. The fracture conductivity was back-calculated by matching pseudosteady production rate data to Guo et al's (SPE Reserve Eval Eng.12, 2009, 879) productivity model for boundary-dominated flow. The fracture conductivity was estimated to range from 0.4 md-ft to 3.2 md-ft, averaging at 1.4 md-ft. Based on Guo et al's (SPE Reserve Eval Eng.12, 2009, 879) well productivity model applied to TMS condition, well productivity can be improved significantly by increasing fracture length and conductivity. Future TMS wells should be completed with conductivity values of greater than 10 md-ft.

04 OIL SHALES AND TAR SANDS↗

Aircraft measurements of NO(x) over the eastern Pacific and continental United States and implications for ozone production

Results are reported from airborne measurements of NO, NO2, O3, and CO obtained in the free troposphere (FT) and boundary layer (BL) over the western U.S. and eastern Pacific during the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 (CITE 2) in summer 1986. The aircraft instrumentation and the CITE 2 flight protocols are described, and the results are presented in extensive tables and graphs. Over the ocean the median mixing ratios for NO and NO2 were found to be 4.0 and 10.4 parts per trillion by volume (pptv), respectively, in the BL and 12.4 and 18.0 pptv in the FT; the corresponding values over land were 34.5 and 75.0 pptv in the BL and 13.0 and 36.0 pptv in the FT. in continental air masses. NO(x) is shown to be positively correlated with O3 and CO and negatively correlated with dewpoint over the ocean, whereas over land NO(x) was positively correlated with O3, CO, and dewpoint.

Carroll, M. A.↗

Southern Sector Humate Injection Well Performance Testing

Three short duration injection tests were conducted on wells at the humate test site. For each injection event, potable water was gravity drained into the well casing. Pressure response was monitored in the injection well and these data were used to estimate the injection capacity of each well. Injection capacity was calculated by dividing the average injection flow rate by the head increase observed in the injection well. Nearby injection wells were used as observation wells and data from these wells were used to estimate the local hydraulic conductivity. The results of this analysis show that it is hydraulically feasible to gravity inject water into the test wells. The estimated water injection capacity of each well as determined by injecting potable water is shown. It is important to note that these short duration tests utilized water and not the humate solution that will ultimately be injected into the aquifer. The results of these tests do not account for physical or chemical processes that may occur over longer time scales. Injection well performance typically declines over time due to water-chemistry issues, air entrainment, and aquifer clogging. Therefore, these results should be viewed as optimistic estimates of injection capacity. Data from the injection tests were analyzed to estimate local aquifer properties. Transmissivity values for all tests ranged from 0.62 to 1.07 ft 2 /min with an average value of 0.805 ft 2 /min. Hydraulic conductivity was calculated by dividing transmissivity by the aquifer thickness (53 ft). Hydraulic conductivity ranged from 16.7 to 29.2 ft/day with an average value of 21.9 ft/day. Storativity values ranged from 0.0001 to 0.001 with an average value of 0.0006.

54 ENVIRONMENTAL SCIENCES↗

Kinetic study of polymerization/curing of filament-wound composite epoxy resin systems with aromatic diamines

The kinetics of polymerization/curing of a filament-wound composite epoxy resin consisting of an 80/20 DGEBA/DGEBD blend and an MDA/m-PDA blend (Tonox 60/40) was studied at various temperatures and at amine epoxy ratios between 1.1 and 4.4 by means of Fourier-transform (FT) IR and bulk viscosity measurements. The activation energy for the polymerization/curing reaction using an amine/epoxy ratio of 1.1 was 11.9 kcal/mole, in agreement with a previous value. The FT-IR conversion-time plots were fitted to a kinetic expression containing two rate constants with activation energies of 13.7 and 10.0 kcal/mole. The bulk viscosity followed the Williams et al. (1955) equation, with a Di Benedetto (1965) expression for the glass transition temperature.

Golub, M. A.↗

The Birth of a Data Center

Since 2005, Research and Education Campus serves as the gateway to INL University Boulevard Consolidates scientific studies, increased interaction and educational opportunities Teams with local commercial developers, the State of Idaho, and Idaho universities Developed University Boulevard 7 major R&D Leased facilities (388,000 sq. ft.) $122M capital value of leased property Some facilities are at and others forecasted to exceed capacity within 2-3 years as mission growth continues DOE awarded the INL contract to BEA, Feb. 2005. Purpose; transform two uniquely different National Laboratories into the newly formed Idaho National Laboratory Become the pre-eminent, internationally recognized nuclear energy research, development and demonstration laboratory within 10 years. Aggressively streamline, upgrade and plan for new infrastructure INL Infrastructure Transformation Plan, Sept 2005, an overall roadmap for transforming INL to meet the new vision. Key goal; procure 400,000 sq ft of new facility space DOE-NE approved Mission Need document for consolidating the INL Research and Education Campus (REC), Dec. 2005; add or replace 200,000 to 500,000 sq ft of professional scientific space, existing facilities were fair to poor condition. Master Campus Plan requirements document and Environmental Assessment approved January and March 2007 respectively. Defined campus location and REC boundaries. INL and DOE-ID decided, in 2007, to suspend quest for third-party financing, because unlikely to succeed. The strategy was; Keep original target of 200,000 to 500,000 sq ft new space Consolidate existing scattered leases Pursue developer-financed facilities in smaller incremental sizes All leased general purpose buildings;No DOE capital investments (except for utility corridor), developed by others (local developers, State, University, private funding), no government land involved INL-funded tenant improvements

99 GENERAL AND MISCELLANEOUS↗

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cruise noise of an advanced single-rotation propeller measured from an adjacent aircraft

Results are reported from flight measurements of the noise from a full-scale SR-7L advanced single-rotation turbofan model mounted on the wing of the NASA Lewis Propfan Test Assessment (PTA) aircraft (a modified Gulfstream II). Data obtained on the PTA with an outboard microphone boom and by the NASA Lewis acoustically instrumented Learjet flying along several sidelines relative to the PTA are presented in tables and graphs and briefly discussed. It is found that the PTA-boom and Learjet sound levels are in good agreement at Mach 0.69 and altitude 20,000 ft, but the Learjet values are significantly lower than the boom levels at Mach 0.79 and altitude 36,000 ft.

Woodward, Richard P.↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Factors influencing dry season ozone distributions over the tropical South Atlantic

Airborne measurements of trace gas and aerosol species were obtained in the lower troposphere (less than 5 km) over the western Atlantic Ocean between 13 deg S and 40 deg N during the August/September 1990 NASA Chemical Instrument Test and Evaluation (CITE 3) experiment. The largest background O3 mixing ratios, averaging 35 and 70 ppbv within the mixed layer (ML) and free troposphere (FT; altitudes greater than 2.4 km), respectively, were found over the tropical South Atlantic. Several competing processes were observed to regulate O3 budgets in this region. Within the ML, rapid photochemical destruction produced a diurnal O3 variation of 8 ppbv and an O3/altitude gradient between the surface and 5 km of almost 10 ppbv (O3)/km. ML O3 concentrations were replenished by atmospheric downwelling which occurred at rates of up to and exceeding 1 cm/s. Ozone values within the subsiding FT air were enriched both by long-range transport of O3 produced photochemically within biomass combustion plumes and the downward propagation of dry, upper tropospheric air masses. Overall, the tropospheric O3 column below 3.3 km averaged 13.5 Dobson units (DU) over the South Atlantic region, which is 8-9 DU higher than observed during CITE 3 ferry flights over the northern tropical Atlantic Ocean or measured by ozonesondes over coastal Brazil during the wet season. An examination of simultaneous dew point and combustion tracer (e.g., CO) measurements suggests that the dry subsiding layers and biomass burning layers make approximately equal contributions to the observed O3 enhancement.

Anderson, B. E.↗

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗