Frequency-Selectable Laser Source (FLS) Calibrator for CMB Bandpass Characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from our detector bandpass calibration. Uncertainties in bandpass can severely limit our measurements by limiting foreground removal and spectral fitting, which is particularly important for high-$\ell$ observations like cluster science using the Sunyaev-Zeldovich (SZ) effect. Currently, CMB experiments typically use a Fourier Transform Spectrometer (FTS) to measure the detector bandpasses. However, the resolution of the FTS is dependent on the length of the interferometer arms, leading to a need for increasingly large FTS instruments as CMB experiments require tighter constraints on detector bandpasses. Additionally, systematic effects like shifts in bandpass shape from uneven illumination from the FTS further limit the calibration uncertainties. As a complement to the FTS, we have developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency housed in a calibrator that allows for varying degrees of laser power attenuation. We present several tests used to characterize the first prototype design of the FLS calibrator, as well as the improvements to the calibrator design currently underway.

Saunders, Lauren [Fermilab]↗

Frequency-Selectable Laser Source (FLS) for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M.↗

A high-resolution Fourier Transform Spectrometer for planetary spectroscopy

The employment of a high-resolution Fourier Transform Spectrometer (FTS) is described for planetary and other astronomical spectroscopy in conjunction with the 88-inch telescope at Mauna Kea Observatory. The FTS system is designed for a broad range of uses, including double-beam laboratory spectroscopy, infrared gas chromatography, and nuclear magnetic resonance spectroscopy. The data system is well-suited to astronomical applications because of its great speed in acquiring and transforming data, and because of the enormous storage capability of the magnetic tape unit supplied with the system. The basic instrument is outlined 2nd some of the initial results from the first attempted use on the Mauna Kea 88-inch telescope are reported.

Cruikshank, D. P.↗

Twilight Intensity Variation of the Infrared Hydroxyl Airglow

The vibration rotation bands of the hydroxyl radical are the strongest features in the night airglow and are exceeded in intensity in the dayglow only by the infrared atmospheric bands of oxygen. The variation of intensity during evening twilight is discussed. Using a ground-based Fourier Transform Spectrometer (FTS), hydroxyl intensity measurements as early as 3 deg solar depression were made. Models of the twilight behavior show that this should be sufficient to provide measurement of the main portion of the twilight intensity change. The instrument was equipped with a liquid nitrogen-cooled germanium detector whose high sensitivity combined with the efficiency of the FTS technique permits spectra of the region 1.1 to 1.6 microns at high signal-to-noise to be obtained in two minutes. The use of a polarizer at the entrance aperture of the instrument reduces the intensity of scattered sunlight by a factor of at least ten for zenith observations.

Lowe, R. P.↗

Planetary infrared astronomy using a cryogenic postdisperser on Fourier transform spectrometers

High resolution infrared spectra of planets from ground-based observatories were analyzed and instrumentation to improve sensitivity was developed. A cryogenic postdisperser (a narrow bandpass spectral filter) for use with Fourier transform spectrometers (FTS's) at facility observatories was constructed. This instrument has improved the sensitivity of FTS observations at 8 to 20 microns by about an order of magnitude. Spectra of Jupiter, Saturn and Comet Halley were obtained using the postdisperser with FTS facilities at the Kitt Peak 4-meter and McMath telescopes. Spectral resolution as high as 0.01/cm was achieved.

Jennings, D. E.↗

Monodeuterated methane in the outer Solar System. Part 3: Its abundance on Titan

The 3 nu 2 band of CH3D has been detected in spectra of Titan recorded at 1.6 microns with the Fourier Transform Spectrometer (FTS) at the 4 m telescope of the Kitt Peak National Observatory (NOAO). We have obtained a value of the CH3D/CH4 mixing ratio of 6.6 (+6.6 or -3.3) x 10 to the -4 from a comparison between the observed Titan spectra and synthetic spectra. This value is approx. 2 times higher than the value measured on Uranus (de Bergh et al. 1986) and approx. 6 times higher than on Jupiter and on Saturn (Courtin et al. 1984; de Bergh et al. 1986). It corresponds to D/H of 1.65 (+1.65 or -0.8) x 10 the -4, nominally 8 times higher than the most commonly accepted value for the protosolar D/H = 2 x 10 to the -5 (Geiss and Reeves 1981). The value we find on Titan for D/H in methane is comparable to the D/H ratio measured in terrestrial H2O.

Debergh, C.↗

High resolution infrared spectroscopy of planetary molecules using diode lasers and Fourier transform spectrometers

Modern observations of infrared molecular lines in planets are performed at spectral resolutions which are as high as those available in the laboratory. Analysis of such data requires laboratory measurements at the highest possible resolution, which also yield accurate line positions and intensities. For planetary purposes the spectrometer must be coupled to sample cells which can be reduced in temperature and varied in pressure. An approach which produces the full range of required molecular line parameters uses a combination of tunable diode lasers and Fourier transform spectrometers (FTS). The FTS provides board spectral coverage and good calibration accuracy, while the diode laser can be used to study those regions which are not resolved by the FTS.

Jennings, Donald E.↗

Laboratory studies, analysis, and interpretation of the spectra of hydrocarbons present in planetary atmospheres including cyanoacetylene, acetylene, propane, and ethane

Combining broadband Fourier transform spectrometers (FTS) from the McMath facility at NSO and from NRC in Ottawa and narrow band TDL data from the laboratories with computational physics techniques has produced a broad range of results for the study of planetary atmospheres. Motivation for the effort flows from the Voyager/IRIS observations and the needs of Voyager analysis for laboratory results. In addition, anticipation of the Cassini mission adds incentive to pursue studies of observed and potentially observable constituents of planetary atmospheres. Current studies include cyanoacetylene, acetylene, propane, and ethane. Particular attention is devoted to cyanoacetylen (H3CN) which is observed in the atmosphere of Titan. The results of a high resolution infrared laboratory study of the line positions of the 663, 449, and 22.5/cm fundamental bands are presented. Line position, reproducible to better than 5 MHz for the first two bands, are available for infrared astrophysical searches. Intensity and broadening studies are in progress. Acetylene is a nearly ubiquitous atmospheric constituent of the outer planets and Titan due to the nature of methane photochemistry. Results of ambient temperature absolute intensity measurements are presented for the fundamental and two two-quantum hotband in the 730/cm region. Low temperature hotband intensity and linewidth measurements are planned.

Blass, William E.↗

Description of SAFIRE for ISES

The SAFIRE (Spectroscopy of the Atmosphere using Far Infrared Emission) is a limb emission experiment using a far-IR Fourier transform spectrometer (FTS) and a mid-IR broadband multispectral radiometer covering the range 80 to 1600/cm. The purpose of this experiment is to obtain vertical distributions of temperature and key constituents of O(y), HO(y), NO(y), ClO(y), and BrO(y) families in the stratosphere, mesosphere, and thermosphere. The spectral channels and gases within each channel are summarized. The instrument includes a 48 element (6 x 8) Ge:GA detector array operating at 4 K in the far-IR and a 105 element (7 x 15) HgCdTe array operating at 80 K in the mid-IR. The SAFIRE uses four different scan modes for vertical coverage and resolution to address various scientific requirements. The SAFIRE data reduction will start with the retrieval of temperature profile as a function of pressure using two CO2 channel data. Constituent distributions then are obtained from other channel data using the retrieved temperature profile. The SAFIRE measurements are limited to the region above the tropopause because of radiance saturation by H2O and clouds. The computational capability necessary to process at the instrument data rate is estimated to be 19 MFLOPS for FTS data and 0.02 MFLOPS for radiometer data. It seems, therefore, that the real-time applications of SAFIRE data using an onboard processing device is not feasible. Although a temperature anomaly may be detected from the two CO2 radiometer channels using an onboard processor for the stratosphere, it is not possible to distinguish between CO2 outflux and temperature anomaly. Temperature anomaly does not, therefore, offer tropospheric information useful for real-time application.

Park, Jae H.↗

Tracking atmospheric trace gases by spectroscopy from Kitt Peak

Researchers analyzed solar spectra obtained with the 1-m Fourier Transfer Spectrometer (FTS) for absorption by CO2, CH4, N2, CO, HF, and HCl. During the period 1979 to 1985, they found that the CO2 total column amount was increasing 0.4 percent/year, CH4 was up 1.1 percent/year, while N2O shows no detectable trend. CO undergoes a large seasonal variation that masks any long-term trend within the observational time span. Stratospheric HF doubles in strength, displaying a conspicuous single-point increase that coincided with the mystery volcanic event of that era. Researchers are now attempting to resume the observations as resources permit.

Wallace, Lloyd↗

Infrared spectroscopic remote sensing from the Cassini orbiter

An infrared spectroscopy instrument for infrared remote sensing from the Cassini orbiter is being breadboarded in the laboratory. The Composite Infrared Spectrometer (CIRS) consists of a pair of Fourier Transform Spectrometers (FTS) which together cover the range from 10 - 1400/cm with a spectral resolution up to 0.5/cm. The far-infrared FTS is a polarizing interferometer covering the 10 - 300/cm range. The mid-infrared FTS is a conventional Michelson FTS covering 200 - 1400/cm in three spectral channels. CIRS will retrieve information on the atmospheres of Titan and Saturn with good vertical resolution, from deep in their tropospheres to high in their stratospheres, and into the upper few centimeters of the regoliths of icy objects. The science objectives and design of CIRS are discussed.

Kunde, V.↗

On the apparent velocity of integrated sunlight. 2: 1983-1992 and comparisons with magnetograms

We report additional results in our program to monitor the wavelength stability of lines in the 2.3 micrometer spectrum of integrated sunlight. We use the McMath Fourier transform spectrometer (FTS) of the National Solar Observatory to monitor 16 delta V = 2 lines of (12)C(16)O, as well as five atomic lines. Wavenumber calibration is achieved using a low-pressure N2O absorption cell and checked against terrestrial atmospheric lines. Imperfect optical integration of the solar disk remains the principal source of error, but this error has been reduced by improved FTS/telescope collimation and observing procedures. The present results include data from an additional 13 quarterly observing runs since 1985. We continue to find that the apparent velocity of integrated sunlight is variable, in the sense of having a greater reshift at solar maximum. This is supported by the temporal dependence of the integrated light velocity, and by the presence of a correlation between velocity and the disk-averaged magnetic flux derived from Kitt Peak magnetograms. The indicated peak-to-peak apparent velocity amplitude over a solar cycle is approximately the same as the velocity amplitude of the Sun's motion about the solar system barycenter. This represents about half the amplitude which we inferred in Paper I (Deming et al. 1987), but the present result has a much greater statistical significance. Our results have implications for those investigations which search for the Doppler signatures of planetary-mass companions to solar-type stars. We contrast our results to the recent finding by McMillan et al. 1993 that solar absorption lines in the violet spectral region are wavelength-stable over the solar cycle.

Deming, Drake↗

Temperature dependence of Lorentz air-broadening and pressure-shift coefficients of (12)CH4 lines in the 2.3-micron spectral region

High-resolution (0.01/cm) absorption spectra of lean mixtures of CH4 in dry air were recorded with the McMath-Pierce Fourier transform spectrometer (FTS) of the National Solar Observatory on Kitt Peak at various temperatures between 24 and -61 C. The spectra have been analyzed to determine the values at room temperature of pressure-broadened widths and pressure-induced shifts of more than 740 transitions. The temperature dependence of air-broadened widths and pressure-induced shifts was deduced for approx. 370 transitions in the nu(sub 1) + nu(sub 4), nu(sub 3) + nu(sub 4), and nu(sub 2) + nu(sub 3) bands of (12)CH4 located between 4118 and 4615/cm. These results were obtained by analyzing a total of 29 spectra simultaneously using a multi-spectral non-linear least-squares fitting technique. This new technique allowed the determination of correlated spectral line parameters (e.g. intensity and broadening coefficient) better than the procedure of averaging values obtained by fitting the spectra individually. This method also provided a direct determination of the uncertainties in the retrieved parameters due to random errors. For each band analysed in this study the dependence of the various spectral line parameters upon the tetrahedral symmetry species and the rotational quantum numbers of the transitions is also presented.

Devi, V. Malathy↗

A Novel Application of Fourier Transform Spectroscopy with HEMT Amplifiers at Microwave Frequencies

The goal was to develop cryogenic high-electron-mobility transistor (HEMT) based radiometers and use them to measure the anisotropy in the cosmic microwave background (CMB). In particular, a novel Fourier transform spectrometer (FTS) built entirely of waveguide components would be developed. A dual-polarization Ka-band HEMT radiometer and a similar Q-band radiometer were built. In a series of measurements spanning three years made from a ground-based site in Saskatoon, SK, the amplitude, frequency spectrum, and spatial frequency spectrum of the anisotropy were measured. A prototype Ka-band FTS was built and tested, and a simplified version is proposed for the MAP satellite mission. The 1/f characteristics of HEMT amplifiers were quantified using correlation techniques.

Wilkinson, David T.↗

Spectroscopic data for thermal infrared remote sensing

There has been extensive world-wide use of chloro-fluoro-carbons (CFC's), especially CFC-11 (CFCl3) and CFC-12 (CF2Cl2), hydro-chloro-fluoro-carbons (HCFC's), HCFC-22 (CHFCl2) in particular, and sulphur hexaflouride (SF6) in numerous many industrial applications. These chemicals possess either a strong ozone-depletion potential or a global-warming potential, or both, and pose a threat to the inhabitability of our planet. Recognition of this fact has led to significant curtailment, if not total banishment, of their use globally. However, as recent satellite observations have shown, decline in their atmospheric concentrations may not be immediate. The marked depletion of ozone which has been observed in recent years at high latitudes has made infrared remote sensing of the atmosphere an activity of high priority. The success of any infrared remote sensing experiment conducted in the atmosphere depends upon the availability of accurate, high-resolution, spectroscopic data that are applicable to that experiment. This paper presents a preliminary phase of a multi-faceted work using a Fourier-transform spectrometer (FTS) which is in progress in our laboratory. The concept of how laboratory-borne measurements can be geared toward obtaining a database that is directly applicable to satellite-borne remote sensing missions is the main thrust of this paper which addresses itself to ongoing or planned international space missions. Spectroscopic data on the unresolvable bands of the above mentioned as well as several other man-made gases and on the individual spectral lines of such naturally present trace gases as CO2, N2O, NH3, and CH4 are presented. There is often significant overlap between the isolated lines of better known bands of the more abundant species and the weaker absorption features identifiable as bands of the currently less abundant CFC's, HCFC's, and SF6.

Varanasi, P.↗

The Prospect for Remote Sensing of Cirrus Clouds with a Submillimeter-Wave Spectrometer

Given the substantial radiative effects of cirrus clouds and the need to validate cirrus cloud mass in climate models, it is important to measure the global distribution of cirrus properties with satellite remote sensing. Existing cirrus remote sensing techniques, such as solar reflectance methods, measure cirrus ice water path (IWP) rather indirectly and with limited accuracy. Submillimeter/wave radiometry is an independent method of cirrus remote sensing based on ice particles scattering the upwelling radiance emitted by the lower atmosphere. A new aircraft instrument, the Far Infrared Sensor for Cirrus (FIRSC), is described. The FIRSC employs a Fourier Transform Spectrometer (FTS). which measures the upwelling radiance across the whole submillimeter region (0.1 1.0-mm wavelength). This wide spectral coverage gives high sensitivity to most cirrus particle sizes and allows accurate determination of the characteristic particle size. Radiative transfer modeling is performed to analyze the capabilities of the submillimeter FTS technique. A linear inversion analysis is done to show that cirrus IWP, particle size, and upper-tropospheric temperature and water vapor may be accurately measured, A nonlinear statistical algorithm is developed using a database of 20000 spectra simulated by randomly varying most relevant cirrus and atmospheric parameters. An empirical orthogonal function analysis reduces the 500-point spectrum (20 - 70/cm) to 15 "pseudo-channels" that are then input to a neural network to retrieve cirrus IWP and median particle diameter. A Monte Carlo accuracy study is performed with simulated spectra having realistic noise. The retrieval errors are low for IWP (rms less than a factor of 1.5) and for particle sizes (rins less than 30%) for IWP greater than 5 g/sq m and a wide range of median particle sizes. This detailed modeling indicates that there is good potential to accurately measure cirrus properties with a submillimeter FTS.

Evans, K. Franklin↗

The Fundamental Quadrupole Band of (14)N2: Line Positions from High-Resolution Stratospheric Solar Absorption Spectra

The purpose of this note is to report accurate measurements of the positions of O- and S-branch lines of the (1-0) vibration-rotation quadrupole band of molecular nitrogen ((14)N2) and improved Dunham coefficients derived from a simultaneous least-squares analysis of these measurements and selected infrared and far infrared data taken from the literature. The new measurements have been derived from stratospheric solar occultation spectra recorded with Fourier transform spectrometer (FTS) instruments operated at unapodized spectral resolutions of 0.002 and 0.01 /cm. The motivation for the present investigation is the need for improved N2 line parameters for use in IR atmospheric remote sensing investigations. The S branch of the N2 (1-0) quadrupole band is ideal for calibrating the line-of-sight airmasses of atmospheric spectra since the strongest lines are well placed in an atmospheric window, their absorption is relatively insensitive to temperature and is moderately strong (typical line center depths of 10 to 50% in high-resolution ground-based solar spectra and in lower stratospheric solar occultation spectra), and the volume mixing ratio of nitrogen is constant in the atmosphere and well known. However, a recent investigation has'shown the need to improve the accuracies of the N2 fine positions, intensities, air-broadened half-widths, and their temperature dependences to fully exploit this calibration capability (1). The present investigation addresses the problem of improving the accuracy of the N2 line positions.

Rinsland, C. P.↗

A Dual Polarized Quasi-Optical SIS Mixer at 550-GHz

We describe the design, fabrication, and the performance of a low-noise dual-polarized quasi-optical superconductor insulator superconductor (SIS) mixer at 550 GHz. The mixer utilizes a novel cross-slot antenna on a hyperhemispherical substrate lens, two junction tuning circuits, niobium trilayer junctions, and an IF circuit containing a lumped element 180 deg hybrid. The antenna consists of an orthogonal pair of twin-slot antennas, and has four feed points, two for each polarization. Each feed point is coupled to a two-junction SIS mixer. The 180 deg IF hybrid is implemented using a lumped element/microstrip circuit located inside the mixer block. Fourier transform spectrometer (FTS) measurements of the mixer frequency response show good agreement with computer simulations. The measured co-polarized and cross-polarized patterns for both polarizations also agree with the theoretical predictions. The noise performance of the dual-polarized mixer is excellent, giving uncorrected receiver noise temperature of better than 115 K (DSB) at 528 GHz for both the polarizations.

Chattopadhyay, Goutam↗