Search NASA⌕ Search

SEARCH · Search NASA

Results for “FUEL TANK PRESSURIZATION SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Developing Science-based fueling protocols for 250-bar hydrogen tanks onboard hydrogen ferries: Experiments and modeling

Combined modeling and experimental studies are reported of the fueling of a large (28 kg capacity) 250-bar Type IV hydrogen tank of the type being deployed on early hydrogen ferries, such as the MV Sea Change. The primary goal was to determine how such tanks can be successfully fueled with hydrogen (state of charge greater than 97%) within 45 minutes without exceeding the 82 °C temperature limit for such tanks. The modeling studies show that a gas injector is needed to avoid thermal stratification during hydrogen fueling which can result in potential hot spots. Empirically, precooling of the hydrogen to 0 °C was found to be needed in some of the cases examined, as ambient conditions greatly affected the need for a precooling to achieve the 45-minute fill time desired by end users. The experimental results afforded a calibration of the engineering model SOFIL for these large 250-bar tanks, which now enables using SOFIL to predict volume-averaged hydrogen fueling temperatures to an accuracy of ±2.7°C for these tanks. The model can therefore be used to evaluate potential scenarios for development of a standardized fueling methodology for ferries utilizing large Type-IV tanks.

08 HYDROGEN↗

Temperature Rise on Liner Surfaces of Fuel Cell Electric Vehicle Tanks during Fueling Process

Herein, the temperature of the inner tank walls, or plastic liners, of composite pressure tanks in fuel cell electric vehicles during fueling using three‐dimensional computational fluid dynamics (CFD) models is evaluated. The liner materials are limited to 85.0 °C to prevent thermal stress causing material failure that would result in a hydrogen leak. Therefore, the temperature of hydrogen gas must be limited to below 85.0 °C during the fueling process as dictated by the current fueling protocol. However, there are limited experimental or simulation data confirming that the temperature changes do not exceed the threshold. Herein, the liner temperatures with CFD tank models for two sizes of type IV tanks representative of the upper and lower system bounds that are close to the SAE J2601 fueling protocol (36.0 and 244.0 L) are evaluated. First, each model's reliability is validated with experimental data and then analyzed, and the data are used to evaluate the maximum hydrogen and liner temperatures under real‐world fueling conditions. The evaluation shows that the maximum liner surface temperature of each tank model is at least 7 °C lower than that of the hydrogen. Additionally, there is at least 12 °C difference found between the upper limit and actual liner temperatures.

33 ADVANCED PROPULSION SYSTEMS↗

Autonomous Hydrogen Fueling Station

This project “Autonomous Hydrogen Fueling Station” covered the autonomous refueling with both gaseous hydrogen and liquid hydrogen. The part on gaseous hydrogen focused on the development of an autonomous robotic fueling arm that would couple to a fuel cell engine for hydrogen refueling without guidance from the forklift operator and budget period. Research was also covered for the robotic fueling with a commercial vehicle. The second phase of the project created the baseline for an autonomous liquid hydrogen transfer system that would minimize boil off losses by operating at thermodynamically efficient state points. For the development of the robotic fueling arm, testing was conducted to establish a baseline measurement of the accuracy and repeatability of a human operator positioning a lift truck in front of a dispenser. The goal was to establish the range of motion required for an autonomous fueling mechanism to mate a hydrogen nozzle with a receptacle on a fuel cell system installed in a forklift. The final design comprised a selective compliance articulated robot arm (SCARA)-type mechanism with two arms for horizontal motion and a ball screw for vertical movement and color and LIDAR cameras were used for marker identification and proximity awareness to guide the robotic arm to its target receptacle. Initial tests resulted in 199 out of 200 successful attempts at autonomous coupling of the dispensing coupler and a fuel cell engine, without hydrogen. The dispenser prototype was modified to include tubing for both hydrogen fuel and air purge lines, but subsequent tests were confounded by the shoulder motor over current errors which limited the robot from getting to the fully inserted position to achieve a positive latch. Robotic hydrogen refueling was successfully demonstrated over 1.5 hours of testing, Plug completed 29 successful latches with an average number of 4 sequential latches before failure. However, a robot capable of placing the nozzle with more force is required for higher reliability. For budget period two, a small scale (10 kg / transfer) automated control system was designed that would operate valves to control pressure and flow of liquid nitrogen between a source and receiving tank with an aim to minimize boil off losses by operating at the most thermodynamically efficient state points. Control system logic flow and a P&ID were developed prior to system safety characterization via HAZOP. A control narrative and system state points were defined. Delays in approval for a change of project objective and procurement issues precluded the construction and test of the final prototype system.

08 HYDROGEN↗

Techno-Economic Analysis of Green Hydrogen Energy Storage in a Cryogenic Flux Capacitor

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. Hydrogen storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 36% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at improved densities, but testing is ongoing. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce green GH2. The TEA compares pure hydrogen produced at a small scale for a 25 MW power system and at a large scale in a 500 MW power system. The system allowed for hydrogen imports and exports at a set price with a tank sized for 10 hours of power production. The two power producing technologies are a combined cycle gas turbine (CCGT) and hydrogen fuel cells. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity (LCOE), levelized cost of hydrogen (LCOH), and levelized cost of storage (LCOS) are developed based on the capital cost and operating cost of the systems. The results are shown for current costs using a 2021 benchmark and DOE projections for cost improvements by 2030. The TEA showed that onsite hydrogen generation from SMR has an LCOH of about 1.4 to 2 USD per kg over the life of the plant and the PV hydrogen production LCOH is about 5.2 to 5.5 USD per kg. The LCOS of conventional GH2 systems is estimated to be $210/MWh and cost of storage for LH2 systems is $205/MWh for fuel cell systems and $249/MWh for CCGT systems. CFC improved the LCOS of all these systems to $198/MWh, $191/MWh and $233/MWh respectively. The LCOE also improved with conventional systems between $171/MWh and $228/MWh improved by CFC to between $167/MWh and $212/MWh. Using projections for improvement in costs following DOE’s goals by 2030, green hydrogen improved to as low as $78/MWh LCOS and LCOE for conventional cases. CFC improved over conventional storage with the lowest LCOS being $62/MWh and the lowest LCOE being $73/MWh. These results correspond to an LCOH of $2/kg. Finally, the TEA shows how LCOE is improved for hydrogen conditioning and storage over conventional systems and caverns in the 10 to 50 hour range.

08 HYDROGEN↗

Recent Cryogenic Carbon Capture™ Field Test Results

Sustainable Energy Solutions (SES) has been developing Cryogenic Carbon Capture™ (CCC) since 2008. In that time, two processes have been developed, the External Cooling Loop and Compressed Flue Gas CCC processes (CCC-ECL and CCC-CFG, respectively). The CCC-ECL process cools the flue gas with an external refrigerant loop. This process currently captures up to 1 tonne of CO2 per day (TPD). SES has tested CCC-ECL on real flue gas slip streams from subbituminous coal, bituminous coal, biomass, natural gas, shredded tires, and municipal waste fuels at field sites that include utility power stations, heating plants, cement kilns, and pilot-scale research reactors. The CO2 concentrations from these tests ranged from 5 to 22% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at a modest rate. The CCC-CFG process has been scaled up to a 0.25 ton per day system. This system has been tested on real flue gas streams including subbituminous coal, bituminous coal, and natural gas at field sites that include utility power stations, heating plants, and pilot-scale research reactors. CO2 concentrations for these tests ranged from 5 to 15% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2, and PMxx at 95+%. NO was also captured at 90+%. Hg capture was also verified and the resulting effluent from CCC-CFG was below a 1ppt concentration. This paper will focus on discussion of the capabilities of CCC generally, the results of CCC-ECL field testing, and future steps surrounding the development of this technology. Test results that will be presented have been collected during 9 months of testing at a commercial power plant under funding from the US Department of Energy (DOE) and the host utility. Testing of one of the systems at a commercial cement plant in the United States will also be discussed. During this testing, the system captured CO2 from the cement plant and stored the CO2 in pressurized tanks. These tanks were provided to a partner company that later used the CO2 in a CO2 utilization demonstration. The CO2 was utilized to cure concrete manufactured using cement from the same plant where the CO2 was captured. This integrated capture and utilization demonstration was the first time that the cement industry has shown in the field that it can sequester its CO2 emissions in its main product stream. This represents a potential game changing solution for industrial CO2 emissions. Operational data and host-site feedback indicate that the CCC process is ideally suited for deployment into a variety of commercial environments. A few areas of de-risking remain to make sure the technology can meet very strict industrial reliability standards. These areas of de-risking are identified and discussed. The product CO2 is shown to meet specification for many uses including industrial and merchant applications. The technology is nearing readiness for deployment at commercial scale and several initial target markets have been identified.

20 FOSSIL-FUELED POWER PLANTS↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling of HTTF test PG-26 using RELAP5-3D and SAM

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors (HTGR) with prismatic fuel and reflector blocks [1]. Several tests have been completed at the HTTF including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This summary reports on the analysis of test PG-26 using the INL system code REALP5-3D [2] as well as the ANL system code SAM [3]. Test PG-26 is a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC [4]. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heater banks. The DCC transient was initiated during the 50th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test.

97 MATHEMATICS AND COMPUTING↗

Estimation of Respirable Aerosol Release Fractions through Stress Corrosion Crack-Like Geometries

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the significant backfill pressurization of the canister, up to approximately 800 kPa. This pressure differential offers a relatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the carrier gas flow rates and aerosol transmission properties were evaluated for an engineered microchannel with characteristic dimensions similar to those of an SCC. The microchannel was formed by mating two gage blocks with a slot orifice measuring 28.9 μm (0.0011 in.) tall by 12.7 mm (0.500 in.) wide by 8.86 mm (0.349 in.) long (flow length). Surrogate aerosols of cerium oxide, Ce0 2 , were seeded and mixed inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to demonstrate a new capability to characterize SCCs under well-controlled boundary conditions. Separate modeling efforts are also underway that will be validated using these data. The test apparatus and procedures developed in this study can be easily modified for the evaluation of more complex SCC-like geometries including laboratory-grown SCC samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Diversion Path Analysis: A Proposed Methodology to Develop an MC&A Approach for Liquid-Fueled Molten Salt Reactors

Nuclear material control and accounting (MC&A) is a critical element of both the US Nuclear Regulatory Commission (NRC) and US Department of Energy (DOE)’s domestic safeguards and security requirements. NRC licensees are required, under Title 10 of the Code of Federal Regulations (10 CFR) Part 74 to establish and maintain an MC&A program that captures and records the quantities and locations of special nuclear material (SNM) at the facility. Along with physical protection, MC&A is a key element of domestic nuclear material safeguards that enables the NRC to ensure that SNM is controlled and accounted for. SNM, per 10 CFR Part 74, refers to plutonium, 233 U, and uranium enriched in the isotope 233 U or 235 U, but does not include source material. Periodic physical inventories, coupled with material balance evaluations, are effective and demonstrated tools to account for and detect theft or diversion of SNM in facilities containing SNM in bulk material form (i.e., not in discrete, countable items). Historically in the United States, these types of facilities have included fuel fabrication, conversion, and enrichment facilities. In comparison, reactors have relied on item counting of assemblies and control of SNM while in containment (e.g., a sealed reactor pressure vessel) because, to date, reactor fuel has been in item form. In liquid-fueled molten salt reactors (MSRs), unlike traditional light water reactors (LWRs) or bulk facilities, bulk SNM quantities can change significantly during operation as a result of depletion and transmutation. This introduces challenges to the use of traditional periodic physical inventories and material balance evaluations to detect theft or diversion of SNM in reactors that use SNM in bulk material form. Liquid-fueled (i.e., salt-fueled) MSR facilities are MSRs that use SNM within a salt eutectic as the fuel. The SNM is in a bulk material form any time it is outside of fresh or spent fuel storage containers. Some examples of when SNM will be in bulk form in the facility are during addition of fuel to the reactor system, while fuel is circulating in operation, and while fuel is in a drain tank. Periodic physical inventories and material balance evaluations can likely be effectively applied to many portions of an MSR facility, including all areas where depletion and transmutation are not significantly changing the quantities of SNM within the control area. Within an MSR facility, this would include fresh fuel receipt and loading, waste streams that may contain SNM, irradiated fuel storage outside of the reactor core, and any irradiated fuel processing that may happen after SNM has been removed from the reactor. All of these process steps could rely on measurements of SNM quantities compared with documented inventories. Any discrepancies from predicted (i.e., book) inventories and measured inventories could be quantified as inventory differences, consistent with traditional MC&A guidance from the NRC (e.g., in NUREG-1065 Revision 2, NUREG-2159 Revision 1, and RG 5.29 Revision 2). Within the reactor system, additions and removals to the book inventory include depletion of the SNM (e.g., fission of 235 U), which complicates the use of physical inventories. SNM control, however, can also likely be effectively applied to detect theft of SNM throughout a liquid-fueled MSR facility. To complement these approaches, prior technical reports have identified that a diversion path analysis may be a useful, risk-informed, and performance-based tool to determine suitable elements of an MC&A approach for the reactor system within a liquid-fueled MSR facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling and Simulation of Fuel Dispersal During the Loss-of-Coolant Accident

This document is the compilation of the milestone portion to a larger end of project NEUP report. The executive summary of the modeling portion is provided below: In the event of cladding rupture during a postulated LOCA in a pressurized water reactor, fuel particles, along with fission gases, can be expelled into the reactor core from the fractured fuel rod, a phenomenon referred to as fuel dispersal. The initial stage of fuel dispersal is strongly influenced by the high-pressure ejection of fuel fragments, the size and geometry of the ruptured cladding, and the depressurization history of the fuel rod during the postulated LOCA transient. Depending on the location of the burst orifice relative to the quench front, the dispersal event represents an intricate three-phase flow and heat transfer phenomenon, where high-temperature fuel particles carried by the fission gases interact with the coolant within the narrow subchannels of the fuel assemblies, inducing localized phase change. Given the unique multiphysics nature of this phenomena, the current study develops a dedicated computational framework to predict the mass distribution and cooling of dispersing fuel particles, facilitating post-accident assessment and management of the fuel assemblies. Considering the scale of nuclear reactor applications, a continuum three-fluid model is proposed for simulating the transport of solids within the reactor core. With high-temperature fuel fragments within the liquid media, nucleation sites inducing phase changes are dispersed within the flow domain. Coupled with the fact that the transient dispersal event occurs on different time scales than other three-phase flow applications, this study derives a time-averaged three-fluid flow model without losing generality. The assumptions regarding the continuum treatment of the solid phase and the modeling of fuel dispersal behavior are incorporated to simplify the governing equations and derive applicable closure relations. The computational validation of the model was conducted using adiabatic experimental results obtained from ongoing research at Oregon State University, focusing on characterizing fuel dispersal behavior during simulated LOCA conditions. Settlement characteristics of the solids, quantified by the probability distribution of equivalent particles, closely matched the probability density functions reported in experimental studies. The transport of fuel particles within a scaled 5 × 5 lattice of a pressurized-water reactor rod bundle geometry was modeled through a two-fluid Eulerian framework. The required boundary conditions were evaluated from the fuel performance code BISON in a postulated large-break LOCA scenario. The modeling framework considered solid fuel particles as granular matter, interacting with the gaseous dry steam phase and fission gases through the governing interfacial momentum exchange between the participating fluids. The simulation results provided the volume fraction of the solids obtained at the bottom surface of the enclosing tank geometry. Postulated LOCA leading to fuel dispersal phenomena involves the strong coupling between fuel thermomechanics, cladding deformation, thermal-hydraulics, and fuel particle transport. Incorporation of such a strong coupling in numerical simulation is performed by coupling the multiphysics solvers. In the case of fuel dispersal, a strong coupled simulation can be performed by coupling the BISON code for fuel performance, the TRACE code for system-level thermal hydraulics, and fuel particle transport in Multiphysics Object-Oriented Simulation Environment (MOOSE). For such intricate infrastructure, the MOOSE Framework eases the data transfer between codes. The recent version of MOOSE has incorporated the Navier-Stokes module for the fluid flow. An exploratory exercise was done to gain familiarity with finite volume capabilities in the MOOSE framework to incorporate the Spalart-Allmaras (SA) turbulence model. New finite-volume and auxiliary kernels were introduced to assemble the SA transport equation, compute turbulent viscosity, and evaluate wall distance and diagnostic turbulence terms, fully integrated with existing Navier-Stokes modules. A turbulent lid-driven cavity at a Reynolds number of approximately 10,000 is used for verification. MOOSE shows the robust solver convergence and produces the turbulent features. But it underpredicts the velocity profile and turbulent quantities, emphasizing the need to develop improved SA near-wall treatments (e.g., low-Re corrections or wall functions) as a key direction for future work.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using Additives to Control the Decomposition Temperature of Sodium Borohydride

Hydrogen (H 2 ) shows great promise as zero-carbon emission fuel, but there are several challenges to overcome in regards to storage and transportation to make it a more universal energy solution. Gaseous hydrogen requires high pressures and large volume tanks while storage of liquid hydrogen requires cryogenic temperatures; neither option is ideal due to cost and the hazards involved. Storage in the solid state presents an attractive alternative, and can meet the U.S. Department of Energy (DOE) constraints to find materials containing > 7 % H 2 (gravimetric weight) with a maximum H 2 release under 125 °C. While there are many candidate hydrogen storage materials, the vast majority are metal hydrides. Of the hydrides, this review focuses solely on sodium borohydride (NaBH 4 ), which is often not covered in other hydride reviews. However, as it contains 10.6% (by weight) H 2 that can release at 133 ± 3 JK -1 mol -1 , this inexpensive material has received renewed attention. NaBH 4 should decompose to H 2 (g), Na(s), and B(s), and could be recycled into its original form. Unfortunately, metal to ligand charge transfer in NaBH 4 induces high thermodynamic stability, creating a high decomposition temperature of 530 °C. In an effort make H 2 more accessible at lower temperatures, researchers have incorporated additives to destabilize the structure. This review highlights metal additives that have successfully reduced the decomposition temperature of NaBH 4 , with temperatures ranging from 522 °C (titanium (IV) fluoride) to 379 °C (niobium (V) fluoride). We describe synthetic methods employed, chemical pathways taken, and the challenges of boron derivative formation on H 2 cycling. Though no trends can be found across all additives, it is our hope that compiling the data here will enable researchers to gain a better understanding of the additives’ influence and to determine how a new system might be designed to make NaBH 4 a more viable H 2 fuel source.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Bidirectional Hydrogen Storage

Hydrogen is the most common element in the universe, comprising nearly 75% of all normal matter, and it has been used by scientists for centuries, but it was not fully recognized as an element until 1766, when it was isolated by Henry Cavendish. Early work focused on the generation of hydrogen through the oxidation of metals in water, which released hydrogen gas. Hydrogen’s lighter-than-air and flammable properties were immediately used in engines, zeppelins, and as feedstock for a wide variety of chemical reactions. Several approaches were developed for the production of hydrogen with the most common being associated with the production and conversion of hydrocarbon-based fuels. Coal gasification, steam methane reforming, and other reformation processes provide the majority of current hydrogen production due to the relatively low cost of hydrogen produced through these processes. More than 95% of hydrogen production is used for industrial processes rather than energy storage. To facilitate affordable decarbonization of these industrial processes and to advance the use of hydrogen as a fuel in transportation, DOE launched the Hydrogen Shot as part of the Energy Earthshots Initiative. The goal of the Hydrogen Shot is to reduce the cost of clean hydrogen by 80% to $1/kg of clean hydrogen production within one decade (known as the “1 1 1” goal). This is distinct from the Long-Duration Storage Shot, which is the primary focus of this report; however, it is intrinsically linked to bidirectional hydrogen storage. Several important chemical synthesis processes are dependent upon hydrogen, and the production and use of hydrogen is generally driven by its connection to one of these markets. For example, ammonia is one of the most highly produced chemicals in the world and it depends chiefly on hydrogen. Ammonia is primarily used for agricultural fertilizer and is considered to be largely responsible for a doubling of agricultural production per unit of land over the last century. Another one of hydrogen’s primary uses is as a catalyst in petroleum refining during the desulfurization process. Beyond chemical production, hydrogen is used as a reductant in the production of steel and has been demonstrated as a substitute for metallurgical coal in the production of raw iron. It is even used in the hydrogenation reaction for food products to create more shelf-stable semi-solid fats. However, while hydrogen is produced on the order of 100 million metric tons/year globally to feed these industries, more than 95% of hydrogen is produced from hydrocarbons that emit CO2 during the process. Conversely, electrolysis is a process by which electricity is used to separate hydrogen and oxygen in water molecules, usually across a membrane. Hydrogen production via electrolysis lowers the carbon intensity of produced hydrogen when coupled with low-carbon electricity. Currently, global electrolysis capacity is on the order of 1 GW, which equates to about 500 metric tons/day of hydrogen production. To support large-scale industrial decarbonization, capacity will likely need to increase by two to three orders of magnitude. Electrolysis technology is broadly separated into groups that are defined by the electrolyte used, with further subdivision based on the operating characteristics. The majority of commercial electrolyzer systems are based around three main technology groups: liquid alkaline, proton exchange membrane, and solid oxide. Liquid Alkaline (LA) electrolysis is the oldest, most mature, least expensive, and most common commercial technology, with 400 plants in operation by 1902. Its hydrogen output is low relative to the size of the system due to a low current density. LA electrolysis utilizes a liquid potassium hydroxide solution as the electrolyte. Proton exchange membrane (PEM) electrolysis (also known as polymer electrolyte membrane electrolysis), described in 1960, relies on an acid-impregnated polymer membrane as the electrolyte and typically offers three to six times higher hydrogen production per unit cell area than LA electrolysis. Solid oxide electrolysis, or high-temperature electrolysis, utilizes a ceramic cell as the electrolyte and operates on steam rather than liquid water, enabling electrical efficiencies of more than 90%, which is up from 60% with PEM. Two pre-commercial electrolyzer technologies to note are alkaline exchange membrane (AEM) and proton-conducting solid oxide electrolysis cell (SOEC). AEM potentially has the advantages of both LA and PEM technologies in that it is able to use low-cost materials like LA but with the ability to operate at higher output pressures with a smaller footprint like PEM. Proton-conducting SOEC is similar to commercial SOEC, which uses an oxide-conducting ceramic; however, it uses a proton-conducting ceramic that has the potential to operate at lower temperatures and has lower capital costs. Each of these technologies is experiencing a rapid improvement in performance and a reduction in installed cost, and each appears to be well suited to specific applications. Besides differences in the type of electrolyzer used, the main difference in the architecture of bidirectional hydrogen systems is how the hydrogen is stored. Currently, the most cost-effective way to store large amounts of hydrogen gas is underground, such as in large salt caverns that have been hollowed out. These salt caverns are geographically concentrated in small portions of the United States and are not generally near large metropolitan areas; however, other subsurface architectures are being investigated to expand this reach. A more widely deployable option is aboveground pressurized tanks. These systems are about 10 times as expensive because of the materials and safety margins required to hold hydrogen at high pressures. A third option is using materials-based storage, such as liquid organic hydrogen carriers. By reversibly attaching the produced hydrogen to other molecules, it can be stored at near atmospheric pressure and room temperature. This has the potential to reduce the material cost of storage but may result in a reduction in the efficiency of the process because there are both hydrogen uptake and release processes. While materials-based storage has not been used extensively for large-scale hydrogen storage in the past, there is currently significant activity regarding developing materials and processes for use in large-scale hydrogen storage applications. Electrolysis-produced hydrogen offers an unusual opportunity for energy storage applications. Unlike more conventional energy storage approaches, such as batteries, which operate entirely within electrical markets, hydrogen is a valuable product beyond the electric market and can be directed to the most lucrative use. Hydrogen also can be directly converted back to electricity using either a fuel cell or turbine, or it can be sold to other markets, such as chemical synthesis, steel production, or even export. In this way, excess electricity can be upgraded to the most valuable product. Finally, its use can be actively managed between multiple off-takers; for example, local hydrogen storage can provide a specific amount of stored electricity and any excess can be exported to ammonia production. This flexibility is amplified by the fact that hydrogen storage has fully decoupled power and energy components, which allows for affordable scaling options. Together, this allows a substantial amount of creativity to enable the economic utilization of variable power resources while supporting decarbonization of the industry.

08 HYDROGEN↗

Refining a Novel Process Monitoring Method to Safeguard Continuously Cycling Designs Using Isotopic Ratios

In advanced reactor (AR) designs, a common feature is continuous chemical processing and circulation of the nuclear material. This work bridges a significant measurement gap in safeguarding reactors with circulating fuel or continuous refueling by leveraging and building on the isotope ratio method first developed by our team under an FY21 Advanced Reactors International Safeguards Engagement (ARISE) project (Uribe et al. 2021). In circulating fuel designs, the radioisotope inventory changes from traditional effects (e.g., radioactive decay, fission) but also includes material transport due to pressure and temperature gradients. Such designs may also require regular or continuous additions or removals during operation, which significantly increases the rate of inventory change compared to traditional pressurized water reactor (PWR)s. Thus, directly tracking the nuclear inventory is ineffective since the isotopes are continuously added and removed. The isotope ratio method instead focuses on detecting changes to the input and output flows of radioisotopes. Previous work showed that for well-chosen pairs of isotopes, the isotopic ratio provides a sensitive and lasting indicator of deviation from normal conditions (e.g., startup, shutdown, diversion). The isotope ratio method is a process monitoring method with potential for application in for forward-looking approaches to International Atomic Energy Agency (IAEA) safeguards. The original process monitoring method was developed for a specific case—the decay tank of a thorium-fueled molten salt breeder reactor. In this expanded work, we explored other types of reactors and processes with nonstationary (e.g., flowing) nuclear material, which are difficult to safeguard with traditional methods because of the transient nature of the systems. The goal of the present work is to generalize the isotope ratio method for use in processes with continuously flowing nuclear material. All continuous processes have an average time for isotopes to be replaced in the system. The isotope ratio method works by choosing radioisotopes with half-lives both above and below the processing time. The present work seeks to explore which isotopes are suitable for the method by simulating the nuclear inventory, radioisotope emissions, and detector responses for several classes of advanced reactors. While the method can in principle be applied to other processes (e.g., enrichment or reprocessing facilities), the present work limits scope to ARs with continuously flowing fuel. Section 2 details the mathematics supporting the isotope ratio method, and Section 3 introduces the representative ARs selected for this work. Section 4 discusses how each reactor was analyzed, and Section 5 showcases the results for each representative reactor. Finally, Section 6 provides concluding remarks and suggests pathways for further analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Heavy-Duty Hydrogen Station Equipment Performance Device (HD HyStEP) Specifications and Design Considerations

The original Hydrogen Station Equipment Performance (HyStEP) device was commissioned in 2015 and was critical for the rapid validation of light-duty (LD) hydrogen fueling stations. As applications for hydrogen as a heavy-duty (HD) transportation fuel continue to grow, new heavy-duty stations are being developed to fuel these vehicles that require larger onboard storage tank systems to meet HD transportation demands and drive cycles. The differences in size and geometry from LD vehicles have driven the creation of new hydrogen fueling protocols that will enable safe and economical fueling of HD vehicles. With the new requirements that are set out in HD fueling protocols like SAE J601-5, a new HyStEP-like device is needed to evaluate the capabilities of high-flow hydrogen stations to fuel HD vehicles to the new protocol standard. To create a heavy-duty HyStEP (HD HyStEP) device, an effort has been undertaken to evaluate the requirements that would form the basis for the design of a successful HD HyStEP device. The primary design goal of this HD HyStEP device is its capability of following a test methodology similar to what is outlined in CSA HGV 4.3, which guides the validation of LD fueling dispensers but with adjustments to verify adherence to the HD fueling protocols (SAE J2601-5) for 70 MPa and 35 MPa pressure class vehicles rather than the LD fueling protocols (SAE J2601). The design presented here aims to provide information that enables the creation of an HD HyStEP device that achieves the primary design goal while being informed by the years of experience from the current HyStEP operators.

08 HYDROGEN↗

Quantification of Aerosol Transmission through Stress Corrosion Crack-Like Geometries

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the commercial practice of using more significant backfill pressures in the canister, up to approximately 800 kPa. This pressure differential offers a relatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the rates of gas flow and aerosol transmission of a spent fuel surrogate through an engineered microchannel with dimensions representative of an SCC were evaluated experimentally using coupled mass flow and aerosol analyzers. The microchannel was formed by mating two gage blocks with a linearly tapering slot orifice nominally 13 μm (0.005 in.) tall on the upstream side and 25 μm (0.0010 in.) tall on the downstream side. The orifice is 12.7 mm (0.500 in.) wide by 8.86 mm (0.349 in.) long (flow length). Surrogate aerosols of cerium oxide, CeO 2 , were seeded and mixed with either helium or air inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to add to previous testing that characterized SCCs under well-controlled boundary conditions through the inclusion of testing improvements that establish initial conditions in a more consistent way. These ongoing testing efforts are focused on understanding the evolution in both size and quantity of a hypothetical release of aerosolized spent fuel particles from failed fuel to the canister interior and ultimately through an SCC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Testing of Microchannels and Lab-Grown Stress Corrosion Cracks for Quantification of Aerosol Transmission

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the commercial practice of using higher backfill pressures in the canister, up to approximately 800 kPa, compared to their horizontal counterparts. This pressure differential offers a relatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the rates of gas flow and aerosol transmission of a spent fuel surrogate through an engineered microchannel with dimensions representative of an SCC were evaluated experimentally using coupled mass flow and aerosol analyzers. The microchannel was formed by mating two gage blocks with a linearly tapering slot orifice nominally 13 μm (0.005 in.) tall on the upstream side and 25 μm (0.0010 in.) tall on the downstream side. The orifice is 12.7 mm (0.500 in.) wide by 8.86 mm (0.349 in.) long (flow length). Surrogate aerosols of cerium oxide, CeO 2 , were seeded and mixed with either helium or air inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to add to previous testing that characterized SCCs under well-controlled boundary conditions through the inclusion of testing improvements that establish initial conditions in a more consistent way. While the engineered microchannel has dimensions similar to actual SCCs, it does not reproduce the tortuous path the aerosol laden flow would have to traverse for eventual transmission. SCCs can be rapidly grown in a laboratory setting given the right conditions, and initial characterization and clean-flow testing has begun on lab grown crack samples provided to Sandia National Laboratories (SNL). Many such samples are required to produce statistically relevant transmission results, and SNL is developing a procedure to produce samples in welded steel plates. These ongoing testing efforts are focused on understanding the evolution in both size and quantity of a hypothetical release of aerosolized spent fuel particles from failed fuel to the canister interior and ultimately through an SCC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Continued Investigations of Respirable Release Fractions for Stress Corrosion Crack-Like Geometries

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the commercial practice of using relatively high backfill pressures (up to approximately 800 kPa) in the canister to enhance internal natural convection. This pressure differential offers a comparatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the rates of gas flow and aerosol transmission of a spent fuel surrogate through an engineered microchannel with dimensions representative of an SCC were evaluated experimentally using coupled mass flow and aerosol analyzers. The microchannel was formed by mating two gage blocks with a linearly tapering slot orifice nominally 13 μm (0.005 in.) tall on the upstream side and 25 μm (0.0010 in.) tall on the downstream side. The orifice is 12.7 mm (0.500 in.) wide by 8.89 mm (0.350 in.) long (flow length). Surrogate aerosols of cerium oxide, CeO 2 , were seeded and mixed with either helium or air inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to demonstrate a new capability to characterize SCCs under well-controlled boundary conditions. Modeling efforts were also initiated that evaluate the depletion of aerosols in a commercial dry storage canister. These preliminary modeling and ongoing testing efforts are focused on understanding the evolution in both size and quantity of a hypothetical release of aerosolized spent fuel particles from failed fuel to the canister interior and ultimately through an SCC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technology Feasibility of High-Temperature Heat Pumps for Industrial Drying Process in the US

High-temperature heat pumps are a prospective technology for electrifying and decarbonizing industrial drying processes. This study investigates the technological potential of HTHPs in replacing fossil-fuel burners or steam boilers in industrial spray dryers. The performance of HTHPs with three configurations was investigated, including high high-temperature heat pump boosted with an electric air heater, a steam-generating high-temperature heat pump with multi-stage mechanical vapor compressions, and transcritical high-temperature heat pumps. R1336mzz(Z) is used as the refrigerant in both subcritical and transcritical high-temperature heat pumps, and R717 is used as the working fluid in the mechanical vapor recompression and the heat transfer fluids. Thermodynamic models are built to evaluate the energy efficiency of HTHPs. A case study was carried out on an industrial spray dryer integrated with a waste heat recuperator, where the HTHPs are used to recover precooled air with a dew point of 40℃ and supply heat for drying air at 200℃. For a high-temperature heat pump boosted with an electric air heater, a higher system-level COP is achieved with a high supply temperature from high-temperature heat pump. For a high-temperature heat pump with mechanical vapor recompressions, larger temperature drops in the flashing tank provide higher heat capacities but almost constant values of the coefficient of performance. For a transcritical high-temperature heat pump, an optimum discharge pressure exists for the temperature profiles within the gas cooler and the coefficient of performance. The transcritical high-temperature heat pump provides the best energy efficiency among the three configurations. The theoretical results prove the technical feasibility of high-temperature heat pumps in industrial air-drying applications. .

Wang, Pengtao↗