Search NASA⌕ Search

SEARCH · Search NASA

Results for “Faraday cups”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Numerical studies on saturated kink and sawtooth induced fast ion transport in JET ITER-like plasmas

Here, this presentation examines the energetic particle transport induced by saturated kink modes and sawtooth crashes in JET deuterium plasmas. It is known that kink mode-resonant transport and phase-space redistribution from sawtooth crashes can drive strong fast ion transport with dependencies on particle pitch and energy. Measurements with JET's Faraday cup fast ion loss detector array have shown that the internal kink growth phase preceding sawtooth crashes produces substantial fast ion losses. This report will numerically investigate the dominant energetic particle transport mechanism with a detailed examination of the fast ion phase-space dependencies, resonances, orbit topology changes, induced losses, and redistribution associated with the long-lived, resonant, kink mode and non-resonant sawtooth crash. The ORBIT-kick model forms the basis of the transport studies with realistic fast ion distributions produced from TRANSP. A recently created reduced model for sawtooth induced transport is used while the saturated kink modes are modeled with ideal MHD codes. The simulations were further validated against experiment with a newly developed synthetic Faraday cup fast ion loss detector in addition to scintillator probe and neutron measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shaped Beams from Diamond Field-Emitter Array Cathodes

Diamond field-emitter arrays (DFEAs) are arrays of diamond pyramids with exquisitely sharp tips and micrometer-scale bases that produce high current densities. These arrays can be fabricated in arbitrary shapes, ranging from single tips to many millions of tips, so that they produce an inherently shaped electron beam. Each tip emits a modest current, but the large dense array can produce many Amps. We are investigating these cathodes for use in dielectric wakefield accelerators; however, they may also be applicable to vacuum microwave tubes. Recently, shaped beam production and transport have been demonstrated in the 1.3-GHz RF gun at the Argonne Cathode Test Stand at the Argonne National Laboratory. The charge was measured on a Faraday cup and the beam imaged on a YAG screen with peak electric field gradients on the cathode ranging from 12 to 35 MV/m. Three cathode geometries were tested: one 1-mm equilateral triangle with 7-mu m base pyramids and 10-mu m pitch, one 1-mm equilateral triangle with 10-mu m base and 25-mu m pitch, and one sparse 5 x 5 square array with 20-mu m base and 400-mu m pitch. The two triangular arrays emitted 35 nC in an RF macropulse at 35 MV/m and 13-nC charge at 27 MV/m, respectively, while the sparse array emitted 0.060-nC charge at 15 MV/m. This article presents the results of the triangular array experiments, including damage due to breakdown in the RF gun and initial models of tip-to-tip shielding.

Cathodes↗

Design of target irradiation and diagnostic chamber to study ps-laser generated plasma as a source of singly charged ions for external injection into an electron beam ion source

High repetition-rate (~10 kHz) ps-lasers are becoming available on the market with reasonable cost and may offer several advantages compared to ns-lasers by generating nearly continuous beams of singly charged ions appropriate for the “slow” injection mode into the Electron Beam Ion Source (EBIS). To evaluate these advantages, we will perform studies of a ps-laser generated plasma using a laser with a pulse duration of 8 ps and energy up to 5 mJ per pulse. A vacuum chamber equipped with a 3D target positioner, a focusing lens, and a Faraday Cup has been designed and built for this study. Lens-to-target distance variations have been measured using a laser tracker over the whole range of horizontal and vertical translation for all five targets we will use. The variations were found to be within ±150 µm. This level of “target flatness” should be acceptable for our experimental conditions. Ion currents and ion pulse durations of various elements (from Al to Ta) will be measured for different target irradiation conditions (focal spot size and laser pulse energy). The results obtained will allow us to specify all parameters and geometry of a laser ion source based on a ps-laser to provide external ion injection into the relativistic heavy ion collider EBIS

43 PARTICLE ACCELERATORS↗

Charge breeders: Development of diagnostic tools to probe the underlying physics

Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron-ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.

47 OTHER INSTRUMENTATION↗

Measurement of charge state distributions using a scintillation screen

Absolute cross sections measured using electromagnetic devices to separate and detect heavy recoiling ions need to be corrected for charge state fractions. Accurate prediction of charge state distributions using theoretical models is not always a possibility, especially in energy and mass regions where data is sparse. As such, it is often necessary to measure charge state fractions directly. In this paper we present a novel method of using a scintillation screen along with a CMOS camera to image the charge dispersed beam after a set of magnetic dipoles. A measurement of the charge state distribution for 88 Sr passing through a natural carbon foil is performed. Using a Bayesian model to extract statistically meaningful uncertainties from these images, we find agreement between the new method and a more traditional method using Faraday cups. Additional future work is need to better understand systematic uncertainties. Our technique offers a viable method to measure charge state distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isotopic analysis of Nd nanoparticles using single particle MC-ICP-MS: A comparative study with single particle-ICP-TOF-MS

Single particle - inductively coupled plasma - mass spectrometry (SP-ICP-MS) is a powerful technique for characterization of the elemental and isotopic composition of individual particles. In this work, the capabilities of the newest generation of MC-ICP-MS with acquisition rates down to 50 ms were evaluated for single particle analysis, with a focus on isotopic precision achievable on a single-particle level. Nd (NdVO 4 ) nanoparticles (~120 nm in diameter) were used as case study and were first characterized in terms of mass (respective size) and particle number concentration by SP-ICP-TOF-MS and then by SP-MC-ICP-MS for isotopic precision. For the isotopic ratio measurements, the MC-ICP-MS performance was compared to the ICP-TOF-MS and it was found that the isotope ratio precision was increased (R 2 between 0.98 and 0.99) compared to ICP-TOF-MS (R 2 between 0.88 and 0.97). The accuracy attained on a single particle level, was compared to bulk digestion followed by MC-ICP-MS analysis, and the SP-MC-ICP-MS technique was able to determine the particle population average to be <4 %, percent relative differences for the 142 Nd/ 144 Nd, 143 Nd/ 144 Nd, 145 Nd/ 144 Nd, 146 Nd/ 144 Nd, and 148 Nd/ 144 Nd ratios The detection limit for the SP-MC-ICP-MS approach was also assessed. Here, when utilizing an all Faraday-cup based detection scheme the determined LOD for the measurements was 0.2fg for Nd, per particle. Based on these results, the newest generation of MC-ICP-MS has demonstrated its utility for performing SP measurement, particularly when high precision isotopic determination is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of ATONA Amplifiers to the Measurement of Uranium Isotopic Ratios by Thermal Ionization Mass Spectrometry

Uranium isotopic composition can provide valuable information about the history and provenance of a nuclear material; therefore, uranium isotopic analyses are frequently made in the nuclear forensics, safeguards, and environmental monitoring communities. These measurements have always presented challenges due to the extreme variability in the relative abundance between the major ( 235 U, 238 U) and minor ( 233 U, 234 U, 236 U) isotopes of uranium. Here, the recently developed ATONA (Atto- to Nano-Amp) amplification system paired with Faraday cup detectors has a large dynamic range and low noise floor making it ideal for measuring uranium isotopic ratios in materials of both natural and anthropogenic origin. A wide variety of certified reference materials were analyzed to investigate the utility of the ATONA amplification system for determining uranium isotopic composition in samples ranging from depleted to highly enriched. The ATONA amplifiers provide nearly an order of magnitude improvement in external reproducibility over 10 11 Ω amplifiers when measuring the minor 234 U/ 238 U ratio in isotopically natural and depleted samples and when paired with a secondary electron multiplier can measure very low relative abundance uranium isotopes (i.e., 236 U).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Author Correction: Proton irradiation-decelerated intergranular corrosion of Ni-Cr alloys in molten salt

In the original version of this article, numbers for the beam current densities were incorrectly given as 1.5, 2.0, and 2.5 mA cm -2 in various locations, instead of the correct values 0.3, 0.4, and 0.5 mA cm -2 . This was owing to a measurement error coming from the indirect correspondence between the Faraday cup and the beam profile monitor (BPM) on the accelerator as the proton beam traveling along the beamline resulted in mismatching between calculated values and real beam currents, which were obtained by ex-situ calibration. The following changes have been made in the correct version. The eighth sentence of the Results, and the figure legend of Fig. 2j state '0.3, 0.4, 0.5 mA cm -2 ' in place of '1.5, 2.0, 2.5 mA cm -2 '. The figure legend of Fig. 1j–l states '0.5, 0.4, 0.3 mA cm -2 ' in place of '2.5, 2.0, 1.5 mA cm -2 '. Figure 1e states '0.5 mA cm -2 ' in place of '2.5 mA cm -2 ', Fig. 1h states '0.4 mA cm -2 ' in place of '2.0 mA cm -2 ', and Fig. 1k states ‘0.3 mA cm -2 ' in place of ‘1.5 mA cm -2 '. Figure 2c states '0.5 mA cm -2 ' in place of '2.5 mA cm -2 ', Fig. 2d states '0.4 mA cm -2 ' in place of '2.0 mA cm -2 ', and Fig. 2e states '0.3 mA cm -2 ' in place of '1.5 mA cm -2 '. Figure 2j and k states ‘0.3 mA cm -2 ', '0.4 mA cm -2 ', '0.5 mA cm -2 ' in place of '1.5 mA cm -2 ', '2.0 mA cm -2 ', and '2.5 mA cm -2 ', respectively. The figure legend of Fig. 3b states '0.4 mA cm -2 ' in place of '2.0 mA cm -2 '. The figure legend of Supplementary Fig. 1 states '0.5 mA cm -2 ' in place of '2.5 mA cm -2 '. This has been corrected in the PDF and HTML versions of the Article.

36 MATERIALS SCIENCE↗

Optimization of laser-target parameters for the production of stable lithium beam

A laser ion source coupled with a radio frequency quadrupole linac accelerator is being proposed as a suitable system for the production of a low energy, high-current stable lithium beam. In order to maximize the lithium yield, plasmas generated by laser ablation of different materials based on lithium (Li, LiOH, and LiNbO3) have been characterized by using a Faraday cup and an electrostatic ion analyzer in the time of flight configuration. A wide range of laser power density has been investigated (109–1012 W/cm2) using two Nd:YAG lasers operating at different wavelengths (1064 nm and 532 nm), pulse durations (6 ns and 17 ns), and maximum energies (1400 mJ and 210 mJ). This paper outlines the pros and cons of the investigated materials by studying how the ion energy, yields, and charge state distributions are modified when the laser power density is changed. Considerable attention has been paid to the higher charge states of oxygen, which may occur with the same mass-to-charge ratio of Li3+. The analysis has evidenced that LiNbO3 represents a valid target since it allows minimizing the O6+/7Li3+ ratio down to 2.5% by using a laser power density of 1.8 × 1010 W/cm2. For such a condition, a Li3+ current of 1.4 mA/cm2 has been measured.

Cannavò, A. (ORCID:0000000309759630)↗

Plasma temperature measurement with a silicon photomultiplier (SiPM)

The temperature of a nonneutral plasma confined in a Penning–Malmberg trap can be determined by slowly lowering one side of the trap’s electrostatic axial confinement barrier; the temperature is inferred from the rate at which particles escape the trap as a function of the barrier height. In many experiments, the escaping particles are directed toward a microchannel plate, and the resulting amplified charge is collected on a phosphor screen. The screen is used for imaging the plasma but can also be used as a Faraday cup (FC) for a temperature measurement. The sensitivity limit is then set by microphonic noise enhanced by the screen’s high-voltage bias. Alternately, a silicon photomultiplier (SiPM) can be employed to measure the charge via the light emitted from the phosphor screen. This decouples the signal from the microphonic noise and allows the temperature of colder and smaller plasmas to be measured than could be measured previously; this paper focuses on the advantages of a SiPM over a FC.

Hunter, E. D. (ORCID:0000000236242840)↗

Fusion product measurements by nuclear diagnostics in the Joint European Torus deuterium–tritium 2 campaign (invited)

We report a new deuterium–tritium experimental, DTE2, campaign has been conducted at the Joint European Torus (JET) between August 2021 and late December 2021. Motivated by significant enhancements in the past decade at JET, such as the ITER-like wall and enhanced auxiliary heating power, the campaign achieved a new fusion energy world record and performed a broad range of fundamental experiments to inform ITER physics scenarios and operations. New capabilities in the area of fusion product measurements by nuclear diagnostics were available as a result of a decade long enhancement program. These have been tested for the first time in DTE2 and a concise overview is provided here. Confined alpha particle measurements by gamma-ray spectroscopy were successfully demonstrated, albeit with limitations at neutron rates higher than some 10 17 n/s. High resolution neutron spectroscopy measurements with the magnetic proton recoil instrument were complemented by novel data from a set of synthetic diamond detectors, which enabled studies of the supra-thermal contributions to the neutron emission. In the area of escaping fast ion diagnostics, a lost fast ion detector and a set of Faraday cups made it possible to determine information on the velocity space and poloidal distribution of the lost alpha particles for the first time. This extensive set of data provides unique information for fundamental physics studies and validation of the numerical models, which are key to inform the physics and scenarios of ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparing the kinetics of ionized and neutral atoms from single and multi-element laser-produced plasmas

In this work, kinetics of ion and neutral atom emission features were compared for nanosecond laser-produced plasmas generated from several metal targets (i.e., Al, Ti, Zr, Nb, Ta) and an alloy containing all of these as principal alloying elements. Plasmas were produced by focusing 6 ns, 1064 nm pulses from an Nd:YAG laser on the targets of interest in a vacuum. A Faraday cup was used for collecting ion temporal features while spatially and temporally resolved emission spectroscopy was used for measuring the optical time of flight of various neutral atomic transitions. Our results highlight that most probable ion and atom velocities decay with increasing atomic mass. Trends for ions from the alloy target represent a weighted average where all ions contribute. For both ions and atoms, velocities decrease with increasing heat of vaporization and melting temperature, consistent with the thermal mechanisms that contribute to nanosecond laser ablation. Kinetic energies for neutral atoms from pure metal targets have some variability with atomic mass, whereas kinetic energies for atoms from the alloy target are more similar. These more similar kinetic energies observed for neutral atoms in the multi-element plasma may be attributed to collisions between species from all elements in the Knudsen layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FLASH-therapy suitable single-pulse proton generation using TiH 2 under nanosecond laser irradiation

We investigated proton emission from titanium hydride (TiH 2 ) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 10 9 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH 2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH 2 -based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

43 PARTICLE ACCELERATORS↗

Astigmatic electron beam propagation

An astigmatic electron beam with an ellipticity ratio of approximately 2:1 was examined using the Enhanced Modified Faraday Cup (EMFC) diagnostic to measure its properties and show how the power density distribution varies near the beam waist. Results show that the beam has two power density peaks, one on either side of the beam crossover point, resulting from different focal distances of the major and minor axes of the elliptical beam shape. Quantification of the beam properties was used to establish a depth-of-field where the beam diameter and peak power densities are relatively constant. For the 1 kW beam studied here, the depth-of-field measured approximately ±5 mm from the beam crossover point, illustrating how electron beam diagnostics can be used to identify process control limits for repeatable and reliable welds under non-ideal electron beam power density distribution conditions.

36 MATERIALS SCIENCE↗

Simulating energetic particle losses in JET plasmas with a reverse integration biasing scheme

We report that an integrated energetic particle transport model has been constructed in JET plasmas constrained by experimental fast ion loss measurements. The model incorporates a synthetic fast ion loss detector identical to JET’s thin-foil Faraday cup fast ion loss detector array. The loss model combines analyses from the TRANSP and ORBIT-kick codes with enhanced features for producing the synthetic diagnostic. Extensions to the ORBIT code framework allow a full-orbit representation within the vacuum region that can map particles directly to an installed detector geometry. Since synthetic fast ion loss detectors are plagued by weak loss statistics, a novel reverse integration biasing scheme has been implemented to boost computational efficiency. The model is validated against experimental loss measurements induced by long-lived kink modes and is found to be in good agreement. This confirms the development of a fully integrated transport/loss model which can be quantitatively verified against experiment allowing for future validation and predictive studies. The model is particularly useful for more complicated plasma scenarios that involve multiple fast ion species such as JET’s 2021 DT-campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of a synthetic fast ion loss detector model for Wendelstein 7-X

Abstract We present the first validated synthetic diagnostic for fast ion loss detectors (FILDs) in the Wendelstein 7-X (W7-X) stellarator. This model has been developed on, and validated against experimental data from, a FILD provided by the National Institute for Fusion Science (NIFS-FILD), with potential future applicability to the existing Faraday Cup FILD (FC-FILD) on W7-X as well as the scintillating FILD (S-FILD) currently under development. A workflow combining Monte Carlo codes BEAMS3D and ASCOT5 is used to track fast ions produced by neutral beam injection from the moment of ionization until they are thermalized or lost from the last closed flux surface, and from there to a virtual plane which serves as a projection of the entrance aperture to the FILD. Simulations in ASCOT5 are analyzed via a geometric method to determine the probability of transmission through the FILD aperture and onto the detector as a function of normalized momentum, pitch angle, gyrophase, and position at the virtual plane. This probability is then applied to the simulated ions arriving from the plasma, producing a simulated signal from a computationally tractable number of simulated fast ions. Simulated signals are presented for two W7-X experiments with neutral beam injection and quantitatively compared with experimental measurements from the NIFS-FILD diagnostic. An estimate of the frequency of charge-exchange with neutral particles in the edge is performed, and it is found that this process may have a significant impact on the measured signals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated modeling of alpha particle losses in JET DT plasmas

Alpha particle confinement is crucial for sustaining burning plasmas and designing future reactor concepts. Along with classical/prompt losses, various magnetohydrodynamic instabilities can lead to wave-particle interactions which can transport alpha particles outward from the plasma. This can result in a reduction in plasma heating/performance, and, at worst, damage in-vessel components. Joint European Torus’s recent deuterium–tritium campaigns in 2021–2023 have produced numerous alpha particle loss measurements with its scintillator probe and Faraday cup array fast ion loss detectors as discussed in Bonofiglo et al (2024 Nucl. Fusion 64 096038). This paper will report on integrated energetic particle transport modeling in support of those measurements. The modeling is accomplished with the TRANSP and ORBIT-kick codes with the use of recently developed reduced models which calculate mode structure, amplitude, and the evolving dynamics. When possible, constraints and comparisons to experiment are conducted. Case studies are performed on a variety of magnetohydrodynamic activity, including: fishbones, tearing modes (TMs), and sawtooth crashes. Additionally, a special case of an alpha-driven toroidal Alfvén eigenmode is briefly discussed, where modeling showed marginally weak alpha losses and was unable to support experimental observations. Coupled effects between a TM and toroidal field ripple are presented and were unable to replicate the observations in lost particle pitch but did duplicate the localized flattening of the measured neutron profile. Additional modeling results compare the magnitude of losses and energy/velocity-space sensitivities against experimental observations/measurements for each scenario. This work corroborates numeric alpha transport modeling while also identifying model deficiencies. While this report details alpha transport, it also presents open issues for discussion in assessing the validity of our numerical models towards burning plasmas.

Bonofiglo, Phillip J. [Princeton Plasma Physics La↗

Electron-induced chemical transformation of vapor-phase synthesized hybrid resist materials for EUV and beyond EUV lithography

Here, in this study, we utilize an in situ Fourier transform infrared (FTIR) spectroscopy chamber equipped with an electron flood gun to comprehensively investigate the electron-induced chemical transformations in advanced inorganic–organic hybrid resist thin films. The characteristics of the electron gun were assessed, showing a detectable current decrease with increasing Faraday cup bias voltage, confirming that the electron energies impacting the sample were within the expected range. This unique FTIR system was applied to study two hybrid resist thin-film systems, Al–HQ and Zn–HQ, both exhibiting saturation growth characteristics at 150 °C. Results revealed that Al–HQ demonstrated superior electron sensitivity compared to Zn–HQ at energies ≤ 100 eV. Chemical changes observed were consistent with previous findings, underscoring the potential of this methodology to elucidate exposure mechanisms. This research contributes to the fundamental understanding necessary for the development of advanced resist materials for the next-generation nanolithography applications.

36 MATERIALS SCIENCE↗