Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hydraulic characterization of a fault zone from fracture distribution

A quantitative assessment of how faults control the migration of geofluids is critical in many areas of geosciences. Here we integrated geological fieldwork, quantitative analysis of the fractures distribution and numerical modeling to build a geometrical representation of a fault zone and to characterize its hydraulic properties. Our target is a fault located in the Majella Mountain (Italy). We collected 21 scan lines across the fault profile in order to characterize its architecture. The numerical modeling of the fracture network of the damage zones and their hydraulic parameters was performed using both commercial (Move ® ) and open source software (dfnWorks and PFLOTRAN). Move ® was used to build a representative model of the fault zone using fracture spacing as a proxy, and to model the hydraulic parameters of the different fault domains. dfnWorks and PFLOTRAN were employed to infer the hydraulic parameters of the damage zones of the fault and then upscale these properties to an equivalent continuum domain, suitable for fluid flow simulations through the whole fault zone. Our findings show how even in a relatively small area it is possible to describe changes in terms of hydraulic properties of a fault zone and to build models capable to represent these variations.

58 GEOSCIENCES↗

Hydromechanical Modeling of Fault Rupture in Geologic CO 2 Sequestration: A Comparison of Two Failure Criteria

Abstract The large‐scale implementation of geological carbon sequestration has raised concerns about potential fault activation and induced seismicity, which could compromise storage integrity and pose seismic risks. We theoretically compared two failure criteria, Mohr‐Coulomb (MC) and Modified Cam‐Clay criteria (MCC), to assess fault rupture during CO 2 storage. Both criteria characterize fault behavior in a specific stress regime but differ in reducing the complexity of fault rupture to a few key mechanisms. Using a coupled hydromechanical model, we demonstrate that the choice of a failure criterion and the physics of fault weakening associated with these criteria strongly condition fault response to a given fluid injection. MC mainly relates rupture to friction, while MCC relates rupture to fault poro‐plasticity. Our findings highlight that the selection of a failure criterion, being inherently subjective, can significantly alter the predicted fault behavior during CO 2 storage, thereby impacting the reliability of geomechanical risk assessments.

Cao, M. [Energy Geosciences Division Lawrence Berk↗

Transmission-Line Fault Analysis Using Synchronized Sampling

An automated analysis approach, which can automatically characterize fault and subsequent relay operation, is the focus of this paper. It utilizes synchronized samples captured during transients from both ends of the transmission line to detect, classify, and locate transmission-line faults and can verify that the tripped line has indeed experienced a fault. The proposed method is tested for several faults simulated on an IEEE 118-bus test system and it has been concluded that it can detect and classify a fault using prefault and postfault recorded samples within 7 ms of fault inception and can accurately locate a fault with 3% accuracy. This time response performance is highly desirable since with the increasing use of modern circuit breakers, which can open the faulty line in less than two cycles, the time window of the captured waveforms is significantly reduced due to the unavailability of measurement signals after breakers open.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spread Spectrum Time Domain Reflectometry (SSTDR) Digital Twin Simulation of Photovoltaic Systems for Fault Detection and Location

Utilizing spread spectrum time domain reflectometry (SSTDR) to detect, locate, and characterize faults in photovoltaic (PV) systems is examined in this paper. We present a method to obtain the model parameters that are needed to produce digital twin SSTDR responses for PV systems. The digital twin SSTDR responses could be used to predict faults within the PV systems. Here, the model parameters are the reflection and transmission coefficients at each impedance discontinuity in the PV system along with the propagation coefficients across each PV cable segment. We obtain model parameter by applying inverse modeling techniques to experimental SSTDR data associated with PV systems. Our model parameters can be used in any digital twin simulation method for modeling reflectometry in frequency-dependent and complex loads. For validation, we used the model parameters in a graph network simulation engine and adapted it to be used for SSTDR digital twin simulations in PV systems. We produced simulations for 0 to 10 PV modules connected in series. We also simulated SSTDR responses for open circuit disconnections in a PV setup containing 10 PV modules in series. Results show that all but one simulated disconnect locations match experimental disconnection locations of the same setup with an error of less than 5%.

14 SOLAR ENERGY↗

Characterizing Impacts of Storage Faults on HPC Applications: A methodology and insights

In recent years, the increasing complexity in scientific simulations and emerging demands for training heavy artificial intelligence models require massive and fast data accesses, which urges high-performance computing (HPC) platforms to equip with more advanced storage infrastructures such as solid-state disks (SSDs). While SSDs offer high-performance I/O, it remains unclear about the reliability challenges faced by the HPC applications under the SSD-related failures, in particular, failures resulting in data corruptions. The goal of this paper is to understand the impact of SSD-related data corruptions on the behaviors of complex HPC applications. To this end, we propose FFIS, a FUSE-based fault injection framework that systematically introduces storage faults into the application layer to model the errors originated from SSDs. FFIS is able to plant different I/O related faults into the data returned from underlying file systems, which also enables the investigation on the error resilience characteristics of the scientific file format for the first time. We demonstrate the use of FFIS with three representative real HPC applications, show how each application reacts to the data corruptions, and provide insights on the error resilience of the widely-adopted HDF5 file format for the HPC applications.

Fang, Bo↗

Simulations of Brady's-Type Fault Undergoing CO2 Push-Pull: Pressure-Transient and Sensitivity Analysis

Input and output files used for fault characterization through numerical simulation using iTOUGH2. The synthetic data for the push period are generated by running a forward simulation (input parameters are provided in iTOUGH2 Brady GF6 Input Parameters.txt [InvExt6i.txt]). In general, the permeability of the fault gouge, damage zone, and matrix are assumed to be unknown. The input and output files are for the inversion scenario where only pressure transients are available at the monitoring well located 200 m above the injection well and only the fault gouge permeability is estimated. The input files are named InvExt6i, INPUT.tpl, FOFT.ins, CO2TAB, and the output files are InvExt6i.out, pest.fof, and pest.sav (names below are display names). The table graphic in the data files below summarizes the inversion results, and indicates the fault gouge permeability can be estimated even if imperfect guesses are used for matrix and damage zone permeabilities, and permeability anisotropy is not taken into account.

15 GEOTHERMAL ENERGY↗

Characteristics of Fault Zones in Volcanic Rocks Near Yucca Flat, Nevada Test Site, Nevada

During 2005 and 2006, the USGS conducted geological studies of fault zones at surface outcrops at the Nevada Test Site. The objectives of these studies were to characterize fault geometry, identify the presence of fault splays, and understand the width and internal architecture of fault zones. Geologic investigations were conducted at surface exposures in upland areas adjacent to Yucca Flat, a basin in the northeastern part of the Nevada Test Site; these data serve as control points for the interpretation of the subsurface data collected at Yucca Flat by other USGS scientists. Fault zones in volcanic rocks near Yucca Flat differ in character and width as a result of differences in the degree of welding and alteration of the protolith, and amount of fault offset. Fault-related damage zones tend to scale with fault offset; damage zones associated with large-offset faults (>100 m) are many tens of meters wide, whereas damage zones associated with smaller-offset faults are generally a only a meter or two wide. Zeolitically-altered tuff develops moderate-sized damage zones whereas vitric nonwelded, bedded and airfall tuff have very minor damage zones, often consisting of the fault zone itself as a deformation band, with minor fault effect to the surrounding rock mass. These differences in fault geometry and fault zone architecture in surface analog sites can serve as a guide toward interpretation of high-resolution subsurface geophysical results from Yucca Flat.

58 GEOSCIENCES↗

Development of a Hydrologic Characterization Technology for Fault Zones Final Report

This is the final report for the five-year program of the NUMO-LBNL collaborative project (hereafter called the Project): Development of Hydrologic Characterization Technology for Fault Zones, under a NUMO-DOE/LBNL collaboration agreement. Detailed results from the past four years of study can be found in the each year’s year-end report (Karasaki et al., 2008, 2009, 2010, and 2011; Kiho et al., 2008, 2009, 2010, and 2011). In this report, we discuss the results of the studies conducted in FY2011. We also give a summary of the overall results and findings, as well as the lessons learned during the course of the Project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Hydrologic Characterization Technology of Fault Zones

Through an extensive literature survey we find that there is very limited amount of work on fault zone hydrology, particularly in the field using borehole testing. The common elements of a fault include a core, and damage zones. The core usually acts as a barrier to the flow across it, whereas the damage zone controls the flow either parallel to the strike or dip of a fault. In most of cases the damage zone isthe one that is controlling the flow in the fault zone and the surroundings. The permeability of damage zone is in the range of two to three orders of magnitude higher than the protolith. The fault core can have permeability up to seven orders of magnitude lower than the damage zone. The fault types (normal, reverse, and strike-slip) by themselves do not appear to be a clear classifier of the hydrology of fault zones. However, there still remains a possibility that other additional geologic attributes and scaling relationships can be used to predict or bracket the range of hydrologic behavior of fault zones. AMT (Audio frequency Magneto Telluric) and seismic reflection techniques are often used to locate faults. Geochemical signatures and temperature distributions are often used to identify flow domains and/or directions. ALSM (Airborne Laser Swath Mapping) or LIDAR (Light Detection and Ranging) method may prove to be a powerful tool for identifying lineaments in place of the traditional photogrammetry. Nonetheless not much work has been done to characterize the hydrologic properties of faults by directly testing them using pump tests. There are some uncertainties involved in analyzing pressure transients of pump tests: both low permeability and high permeability faults exhibit similar pressure responses. A physically based conceptual and numerical model is presented for simulating fluid and heat flow and solute transport through fractured fault zones using a multiple-continuum medium approach. Data from the Horonobe URL site are analyzed to demonstrate the proposed approach and to examine the flow direction and magnitude on both sides of a suspected fault. We describe a strategy for effective characterization of fault zone hydrology. We recommend conducting a long term pump test followed by a long term buildup test. We do not recommend isolating the borehole into too many intervals. We do recommend ensuring durability and redundancy for long term monitoring.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Characterization Technology for Fault Zone Hydrology

Several deep trenches were cut, and a number of geophysical surveys were conducted across the Wildcat Fault in the hills east of Berkeley, California. The Wildcat Fault is believed to be a strike-slip fault and a member of the Hayward Fault System, with over 10 km of displacement. So far, three boreholes of ~;; 150m deep have been core-drilled and borehole geophysical logs were conducted. The rocks are extensively sheared and fractured; gouges were observed at several depths and a thick cataclasitic zone was also observed. While confirming some earlier, published conclusions from shallow observations about Wildcat, some unexpected findings were encountered. Preliminary analysis indicates that Wildcat near the field site consists of multiple faults. The hydraulic test data suggest the dual properties of the hydrologic structure of the fault zone. A fourth borehole is planned to penetrate the main fault believed to lie in-between the holes. The main philosophy behind our approach for the hydrologic characterization of such a complex fractured system is to let the system take its own average and monitor a long term behavior instead of collecting a multitude of data at small length and time scales, or at a discrete fracture scale and to ?up-scale,? which is extremely tenuous.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Hydrologic Characterization Technology of Fault Zones -- Phase I, 2nd Report

This is the year-end report of the 2nd year of the NUMO-LBNL collaborative project: Development of Hydrologic Characterization Technology of Fault Zones under NUMO-DOE/LBNL collaboration agreement, the task description of which can be found in the Appendix 3. Literature survey of published information on the relationship between geologic and hydrologic characteristics of faults was conducted. The survey concluded that it may be possible to classify faults by indicators based on various geometric and geologic attributes that may indirectly relate to the hydrologic property of faults. Analysis of existing information on the Wildcat Fault and its surrounding geology was performed. The Wildcat Fault is thought to be a strike-slip fault with a thrust component that runs along the eastern boundary of the Lawrence Berkeley National Laboratory. It is believed to be part of the Hayward Fault system but is considered inactive. Three trenches were excavated at carefully selected locations mainly based on the information from the past investigative work inside the LBNL property. At least one fault was encountered in all three trenches. Detailed trench mapping was conducted by CRIEPI (Central Research Institute for Electric Power Industries) and LBNL scientists. Some intriguing and puzzling discoveries were made that may contradict with the published work in the past. Predictions are made regarding the hydrologic property of the Wildcat Fault based on the analysis of fault structure. Preliminary conceptual models of the Wildcat Fault were proposed. The Wildcat Fault appears to have multiple splays and some low angled faults may be part of the flower structure. In parallel, surface geophysical investigations were conducted using electrical resistivity survey and seismic reflection profiling along three lines on the north and south of the LBNL site. Because of the steep terrain, it was difficult to find optimum locations for survey lines as it is desirable for them to be as straight as possible. One interpretation suggests that the Wildcat Fault is westerly dipping. This could imply that the Wildcat Fault may merge with the Hayward Fault at depth. However, due to the complex geology of the Berkeley Hills, multiple interpretations of the geophysical surveys are possible. iv An effort to construct a 3D GIS model is under way. The model will be used not so much for visualization of the existing data because only surface data are available thus far, but to conduct investigation of possible abutment relations of the buried formations offset by the fault. A 3D model would be useful to conduct 'what if' scenario testing to aid the selection of borehole drilling locations and configurations. Based on the information available thus far, a preliminary plan for borehole drilling is outlined. The basic strategy is to first drill boreholes on both sides of the fault without penetrating it. Borehole tests will be conducted in these boreholes to estimate the property of the fault. Possibly a slanted borehole will be drilled later to intersect the fault to confirm the findings from the boreholes that do not intersect the fault. Finally, the lessons learned from conducting the trenching and geophysical surveys are listed. It is believed that these lessons will be invaluable information for NUMO when it conducts preliminary investigations at yet-to-be selected candidate sites in Japan.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Unsupervised Clustering of Microseismic Events and Focal Mechanism Analysis at the CO 2 Injection Site in Decatur, Illinois

Characterization of induced microseismicity at a carbon dioxide (CO 2 ) storage site is critical for preserving reservoir integrity and mitigating seismic hazards. We apply a multilevel machine learning (ML) approach that combines the nonnegative matrix factorization and hidden Markov model to extract spectral representations of microseismic events and cluster them to identify seismic patterns at the Illinois Basin-Decatur Project. Unlike traditional waveform correlation methods, this approach leverages spectral characteristics of first arrivals to improve event classification and detect previously undetected planes of weakness. By integrating ML-based clustering with focal mechanism analysis, we resolve small-scale fault structures that are below the detection limits of conventional seismic imaging. Our findings reveal temporal bursts of microseismicity associated with brittle failure, providing insights into the spatio-temporal evolution of fault reactivation during CO 2 injection. This approach enhances seismic monitoring capabilities at CO 2 injection sites by improving fault characterization beyond the resolution of standard geophysical surveys.

Willis, Rachel Marie [Sandia National Laboratories↗

Analytical Model to Detect Fault Permeability Alteration Induced by Fault Reactivation in Compartmentalized Reservoirs

Underground fluid injection induces changes in in situ stress condition of the target formation and local faults that can potentially lead to fault reactivation, which may result in the leakage of injected and/or native fluids into neighboring formations. In this paper, we introduce an analytical method to detect fault reactivation caused by fluid injection into deep faulted aquifers considering across-fault leakage. The fundamental assumption made in our model is that fault permeability will be altered upon fault slip. Therefore, we model fault reactivation as a sudden change in fault permeability at the onset of fault slip. The fault is modeled as a linear interface between two permeable formations with equal rock and fluid properties. The governing equations are coupled through the fault interface and are solved using the Laplace-Fourier integral transform technique. Based on the analytical solution, we find the characteristic bottomhole pressure and pressure derivative responses that enable detecting fault reactivation using diagnostic plots. We observe that pressure derivative undergoes a rapid change at the onset of fault slip followed by a late-time trend to attain a new equilibrium governed by the altered fault permeability. Furthermore, we discuss the evolution of the across-fault leakage rate upon and after fault slippage. Here, the results from this study are presented in the form diagnostic plots and type curves that may be used for reservoir and fault characterization purposes.

54 ENVIRONMENTAL SCIENCES↗

Mechanisms for Microseismicity Occurrence Due to CO 2 Injection at Decatur, Illinois: A Coupled Multiphase Flow and Geomechanics Perspective

Here, we numerically investigate the mechanisms that resulted in induced seismicity occurrence associated with CO 2 injection at the Illinois Basin–Decatur Project (IBDP). We build a geologically consistent model that honors key stratigraphic horizons and 3D fault surfaces interpreted using surface seismic data and microseismicity locations. We populate our model with reservoir and geomechanical properties estimated using well-log and core data. We then performed coupled multiphase flow and geomechanics modeling to investigate the impact of CO 2 injection on fault stability using the Coulomb failure criteria. We calibrate our flow model using measured reservoir pressure during the CO 2 injection phase. Our model results show that pore-pressure diffusion along faults connecting the injection interval to the basement is essential to explain the destabilization of the regions where microseismicity occurred, and that poroelastic stresses alone would result in stabilization of those regions. Slip tendency analysis indicates that, due to their orientations with respect to the maximum horizontal stress direction, the faults where the microseismicity occurred were very close to failure prior to injection. These model results highlight the importance of accurate subsurface fault characterization for CO 2 sequestration operations.

58 GEOSCIENCES↗

Near-surface geophysical characterization of Holocene faults conducive to geothermal flow near Pyramid Lake, Nevada

Colton Dudley, Alison Dorsey, Paul Opdyke, Dustin Naphan, Marlon Ramos, John Louie, Paul Schwering, and Satish Pullammanappallil, 2013, Near-surface geophysical characterization of Holocene faults conducive to geothermal flow near Pyramid Lake, Nevada: presented at Amer. Assoc. Petroleum Geologists, Pacific Section Annual Meeting, Monterey, Calif., April 19-25.

15 GEOTHERMAL ENERGY↗

Electrical Arc Fault Particle Size Characterization

In this investigation a series of small-scale tests were conducted, which were sponsored by the Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research (RES) and performed at Sandia National Laboratories (SNL). These tests were designed to better understand localized particle dispersion phenomena resulting from electrical arcing faults. The purpose of these tests was to better characterize aluminum particle size distribution, rates of production, and morphology (agglomeration) of electrical arc faults. More specifically, this effort characterized ejected particles and high-energy dispersion, where this work characterized HEAF electrical characteristics, particle movement/distributions, and morphology near the arc. The results and measurements techniques from this investigation will be used to inform an energy balance model to predict additional energy from aluminum involvement in the arc fault. The experimental setup was developed based on prior work by KEMA and SNL for phase-to-ground and phase-to-phase electrical circuit faults. The small-scale tests results should not be expected to be scale-able to the hazards associated with full-scale HEAF events. Here, the test voltages will consist of four different levels: 480V, 4160V, 6900V and 10kV, based on those realized in nuclear power plant (NPP) HEAF events.

36 MATERIALS SCIENCE↗

Simulations of CO 2 injection into fractures and faults for improving their geophysical characterization at EGS sites

Here, we propose the use of CO 2 in push-pull well tests to improve geophysical identification and characterization of fractures and faults at enhanced geothermal system (EGS) sites. Using TOUGH2/ECO2N, we carried out numerical experiments of push-pull injection-production cycling of CO 2 into idealized vertical fractures and faults to produce pressure-saturation-temperature conditions that can be analyzed for their geophysical response. Our results show that there is a strong difference between injection and production mainly because of CO 2 buoyancy. While the CO 2 -plume grows laterally and upward during injection, not all CO 2 is recovered during the subsequent production phase. Even under the best conditions for recovery, at least 10% of the volume of the pores still remains filled with CO 2 . To improve EGS characterization, comparisons can be made of active seismic methods carried out before and after (time lapse mode) CO 2 injection into the fracture or fault. Here we find that across the CO 2 saturation range, C11 (the normal stiffness in the horizontal direction perpendicular to the fracture plane) varies between maximum and minimum values by about 15%. It reaches a maximum at around 6% gas saturation, decreasing exponentially to a minimum at higher saturations. Finally, our results suggest that CO 2 injection can be effectively used to infiltrate fault and fracture zones reaching about optimal saturation values in order to enhance seismic imaging at EGS sites.

58 GEOSCIENCES↗