Search NASA⌕ Search

SEARCH · Search NASA

Results for “Femtosecond lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Applications of ultrashort laser pulses in science and technology; Proceedings of the Meeting, The Hague, Netherlands, Mar. 12, 13, 1990

Topics discussed are on the generation of high-intensity femtosecond lasers, the high-repetition and infrared femtosecond pulses, and physics of semiconductors and applications. Papers are presented on the femtosecond pulse generation at 193 nm; the generation of intense subpicosecond and femtosecond pulses; intense tunable subpicosecond and femtosecond pulses in the visible and infrared, generated by optical parametric oscillators; a high-efficiency high-energy optical amplifier for femtosecond pulses; and the generation of solitons, periodic pulsing, and nonlinearities in GaAs. Other papers are on ultrafast relaxation dynamics of photoexcited carriers in GaAs, high-order optical nonlinear susceptibilities of transparent glasses, subnanosecond risetime high-power pulse generation using photoconductive bulk GaAs devices, femtosecond studies of plasma formation in crystalline and amorphous silicon, and subpicosecond dynamics of hot carrier relaxation in InP and GaAs.

Antonetti, Andre↗

Testing the Efficacy of Laser Sterilization as A Spacecraft Bioburden Reduction Alternative

As NASA continues to put forth efforts in seeking out life in the solar system with missions like Europa Clipper, Mars Sample Return, and Dragonfly, reducing the bioburden (number of living microbes) on spacecraft is required by NASA policy for the protection of potentially habitable worlds. In this project, we are testing the efficacy of a novel method for laser sterilization on stress tolerant bacterial spores (Bacillus subtilis) using a high energy femtosecond laser. To test the laser, we inoculate metal coupons with Bacillus subtilis spores. After laser treatment, we do a PVA (polyvinyl acetate) peel to recover the spores then we calculate to find the number of spores that survived the treatment. Our results show that within a certain pulse count range, increasing fluence increases sterilization effectiveness. We have demonstrated the ability to reduce viable microbial counts by at least 10-4. By studying laser sterilization, we could change the way spacecraft are sterilized by making the process more efficient and cost-effective.

Planetary protection↗

Laser Processed Condensing Heat Exchanger Technology Development

The reliance on non-permanent coatings in Condensing Heat Exchanger (CHX) designs is a significant technical issue to be solved before long-duration spaceflight can occur. Therefore, high reliability CHXs have been identified by the Evolvable Mars Campaign (EMC) as critical technologies needed to move beyond low earth orbit. The Laser Processed Condensing Heat Exchanger project aims to solve these problems through the use of femtosecond laser processed surfaces, which have unique wetting properties and potentially exhibit anti-microbial growth properties. These surfaces were investigated to identify if they would be suitable candidates for a replacement CHX surface. Among the areas researched in this project include microbial growth testing, siloxane flow testing in which laser processed surfaces were exposed to siloxanes in an air stream, and manufacturability.

Hansen, Scott↗

Implementation of a Pulsed-Laser Measurement System in the National Transonic Facility

A remotely-adjustable laser transmission and imaging system has been developed for use in a high-pressure, cryogenic wind tunnel. Implementation in the National Transonic Facility has proven the system suitable for velocity and signal lifetime measurements over a range of operating conditions. The measurement system allows for the delivery of high-powered laser pulses through the outer pressure shell and into the test section interior from a mezzanine where the laser is free from environmental disturbances (such as vibrations and excessive condensation) associated with operation of the wind tunnel. Femtosecond laser electronic excitation tagging (FLEET) was utilized to provide freestream velocity measurements, and first results show typical data that may be obtained using the system herein described.

Reese, Daniel T.↗

Iodine Tagging Velocimetry in a Mach 10 Wake

A variation on molecular tagging velocimetry (MTV) [1] designated iodine tagging velocimetry (ITV) is demonstrated. Molecular iodine is tagged by two-photon absorption using an Argon Fluoride (ArF) excimer laser. A single camera measures fluid displacement using atomic iodine emission at 206 nm. Two examples ofMTVfor cold-flowmeasurements areN2OMTV [2] and Femtosecond Laser Electronic Excitation Tagging [3]. These, like most MTV methods, are designed for atmospheric pressure applications. Neither can be implemented at the low pressures (0.1- 1 Torr) in typical hypersonic wakes. Of all the single-laser/singlecamera MTV approaches, only Nitric-Oxide Planar Laser Induced Fluorescence-based MTV [4] has been successfully demonstrated in a Mach 10 wake. Oxygen quenching limits transit times to 500 ns and accuracy to typically 30%. The present note describes the photophysics of the ITV method. Off-body velocimetry along a line is demonstrated in the aerothermodynamically important and experimentally challenging region of a hypersonic low-pressure near-wake in a Mach 10 air wind tunnel. Transit times up to 10 μs are demonstrated with conservative errors of 10%.

Balla, Robert Jeffrey↗

Multi-Scale Analysis of an Ilmenite Microcrater in Lunar Sample 71055

Micrometeorite impacts are a key space weathering process on the lunar surface, generating a variety of physical and chemical changes in the lunar regolith. Several experiments using nanosecond pulsed lasers to simulate micrometeorite impact have been published in the past two decades, providing a wealth of knowledge, including how minerals vary in their response to laser irradiation. Although these experiments have produced many features analogous to those observed in natural samples, none could be attributed to the passage of a shock wave, resulting instead from hot ablation. Recent femtosecond laser irradiation of olivine and enstatite have more accurately reproduced the shock textures observed in lunar samples, improving our ability to coordinate experimental and lunar sample data. Both pulsed laser experiments and studies of lunar impact craters have focused on silicates, as they comprise the bulk of the regolith. Ilmenite (FeTiO 3 ) is the most abundant opaque mineral in lunar rocks and an important sink of solar wind implanted helium. Ilmenite is known to vary in its response to radiation processing relative to the silicates, but its response to micrometeorite impact has not yet been studied in natural samples nor in the laboratory. In this investigation, we characterize an ilmenite microcrater using scanning electron microscopy (SEM) and transmission electron microscopy (TEM) to learn how ilmenite responds to impact and if there are implications for helium cycling in the regolith.

B A Cymes↗

Nonresonant interaction of ultrashort electromagnetic pulses with multilevel quantum systems

Some features of the excitation of multilevel quantum systems under the action of electromagnetic pulses which are shorter than the inverse frequency of interlevel transitions are considered. It is shown that the interaction is characterized by a specific type of selectivity which is not connected with the resonant absorption of radiation. The simplest three-level model displays the inverse population of upper levels. The effect of an ultrashort laser pulse on a multilevel molecule was regarded as an instant reception of the oscillation velocity by the oscillator and this approach showed an effective excitation and dissociation of the molecule. The estimations testify to the fact that these effects can be observed using modern femtosecond lasers.

Belenov, E.↗

Laser Ablation Increases PEM/Catalyst Interfacial Area

An investigational method of improving the performance of a fuel cell that contains a polymer-electrolyte membrane (PEM) is based on the concept of roughening the surface of the PEM, prior to deposition of a thin layer of catalyst, in order to increase the PEM/catalyst interfacial area and thereby increase the degree of utilization of the catalyst. The roughening is done by means of laser ablation under carefully controlled conditions. Next, the roughened membrane surface is coated with the thin layer of catalyst (which is typically platinum), then sandwiched between two electrode/catalyst structures to form a membrane/ele c t - rode assembly. The feasibility of the roughening technique was demonstrated in experiments in which proton-conducting membranes made of a perfluorosulfonic acid-based hydrophilic, protonconducting polymer were ablated by use of femtosecond laser pulses. It was found that when proper combinations of the pulse intensity, pulse-repetition rate, and number of repetitions was chosen, the initially flat, smooth membrane surfaces became roughened to such an extent as to be converted to networks of nodules interconnected by filaments (see Figure 1). In further experiments, electrochemical impedance spectroscopy (EIS) was performed on a pristine (smooth) membrane and on two laser-roughened membranes after the membranes were coated with platinum on both sides. Some preliminary EIS data were interpreted as showing that notwithstanding the potential for laser-induced damage, the bulk conductivities of the membranes were not diminished in the roughening process. Other preliminary EIS data (see Figure 2) were interpreted as signifying that the surface areas of the laser-roughened membranes were significantly greater than those of the smooth membrane. Moreover, elemental analyses showed that the sulfur-containing molecular groups necessary for proton conduction remained intact, even near the laser-roughened surfaces. These preliminary results can be taken as indications that laser-roughened PEMs should function well in fuel cells and, in particular, should exhibit current and power densities greater than those attainable by use of smooth membranes.

Whitacre, Jay↗

Quantum Entanglement Molecular Absorption Spectrum Simulator

Quantum Entanglement Molecular Absorption Spectrum Simulator (QE-MASS) is a computer program for simulating two photon molecular-absorption spectroscopy using quantum-entangled photons. More specifically, QE-MASS simulates the molecular absorption of two quantum-entangled photons generated by the spontaneous parametric down-conversion (SPDC) of a fixed-frequency photon from a laser. The two-photon absorption process is modeled via a combination of rovibrational and electronic single-photon transitions, using a wave-function formalism. A two-photon absorption cross section as a function of the entanglement delay time between the two photons is computed, then subjected to a fast Fourier transform to produce an energy spectrum. The program then detects peaks in the Fourier spectrum and displays the energy levels of very short-lived intermediate quantum states (or virtual states) of the molecule. Such virtual states were only previously accessible using ultra-fast (femtosecond) laser systems. However, with the use of a single-frequency continuous wave laser to produce SPDC photons, and QEMASS program, these short-lived molecular states can now be studied using much simpler laser systems. QE-MASS can also show the dependence of the Fourier spectrum on the tuning range of the entanglement time of any externally introduced optical-path delay time. QE-MASS can be extended to any molecule for which an appropriate spectroscopic database is available. It is a means of performing an a priori parametric analysis of entangled photon spectroscopy for development and implementation of emerging quantum-spectroscopic sensing techniques. QE-MASS is currently implemented using the Mathcad software package.

Nguyen, Quang-Viet↗

Velocity Measurements in the Wake of the Swept Wing Flow Test Model at the National Transonic Facility

Femtosecond laser electronic excitation tagging (FLEET) was applied to obtain flowfield velocity data for the Swept Wing Flow Test (SWiFT) at the NASA Langley Research Center National Transonic Facility (NTF). Despite numerous challenges associated with performing flow velocimetry measurements within a large-scale cryogenic wind tunnel facility, the experimental campaign was conducted under various conditions, including dry air at 320 K, cool nitrogen at 240 K, and Mach numbers of 0.2 and 0.8. FLEET velocimetry measurements were performed in the downstream wake of the SWiFT model, providing a quantitative dataset. This dataset includes one-dimensional velocity profiles and two-dimensional velocity maps acquired at different angles of attack and Reynolds numbers. The two-dimensional single component velocity maps indicate relatively uniform flow across the 120-mm wide wake flow survey suggesting that the main flow features can be represented by single-position linear velocity profiles. The measured instantaneous velocity profiles at variable angles of attack are compared to model lift coefficient information obtained at Mach 0.2. At high Reynolds numbers, a sudden velocity decrease was observed in the FLEET measurements at the same time as stall in lift coefficient was observed. At a low Reynolds number, both the velocity profiles and the lift coefficient show a smoother transition, without a sudden stall. Furthermore, the two-dimensional, one component velocity map reveals a velocity deficit region at Mach 0.8 at various angles of attack. Both single shot and mean velocity measurements were acquired allowing assessment of flowfield fluctuations and measurement precisions. The uncertainties are within 4 m/s in mean measurements based on repeatability data and about 5 m/s in instantaneous single-shot measurements. Measurements are reported with ~4.8 mm spatial resolution with 32-pixel averaging used to reduce measurement errors.

femtosecond↗

Velocity Measurements in the Wake of the Swept Wing Flow Test (SWIFT) Model at the National Transonic Facility

Femtosecond laser electronic excitation tagging (FLEET) was applied to obtain flowfield velocity data for the Swept Wing Flow Test (SWiFT) at the NASA Langley Research Center National Transonic Facility (NTF). Despite numerous challenges associated with performing flow velocimetry measurements within a large-scale cryogenic wind tunnel facility, the experimental campaign was conducted under various conditions, including dry air at 320 K, cool nitrogen at 240 K, and Mach numbers of 0.2 and 0.8. FLEET velocimetry measurements were performed in the downstream wake of the SWiFT model, providing a quantitative dataset. This dataset includes one-dimensional velocity profiles and two-dimensional velocity maps acquired at different angles of attack and Reynolds numbers. The two-dimensional single component velocity maps indicate relatively uniform flow across the 120-mm wide wake flow survey suggesting that the main flow features can be represented by single-position linear velocity profiles. The measured instantaneous velocity profiles at variable angles of attack are compared to model lift coefficient information obtained at Mach 0.2. At high Reynolds numbers, a sudden velocity decrease was observed in the FLEET measurements at the same time as stall in lift coefficient was observed. At a low Reynolds number, both the velocity profiles and the lift coefficient show a smoother transition, without a sudden stall. Furthermore, the two-dimensional, one component velocity map reveals a velocity deficit region at Mach 0.8 at various angles of attack. Both single shot and mean velocity measurements were acquired allowing assessment of flowfield fluctuations and measurement precisions. The uncertainties are within 4 m/s in mean measurements based on repeatability data and about 5 m/s in instantaneous single-shot measurements. Measurements are reported with ~4.8 mm spatial resolution with 32-pixel averaging used to reduce measurement errors.

Transonic↗

Theoretical determination of chemical rate constants using novel time-dependent methods

The work completed within the grant period 10/1/91 through 12/31/93 falls primarily in the area of reaction dynamics using both quantum and classical mechanical methodologies. Essentially four projects have been completed and have been or are in preparation of being published. The majority of time was spent in the determination of reaction rate coefficients in the area of hydrocarbon fuel combustion reactions which are relevant to NASA's High Speed Research Program (HSRP). These reaction coefficients are important in the design of novel jet engines with low NOx emissions, which through a series of catalytic reactions contribute to the deterioration of the earth's ozone layer. A second area of research studied concerned the control of chemical reactivity using ultrashort (femtosecond) laser pulses. Recent advances in pulsed-laser technologies have opened up a vast new field to be investigated both experimentally and theoretically. The photodissociation of molecules adsorbed on surfaces using novel time-independent quantum mechanical methods was a third project. And finally, using state-of-the-art, high level ab initio electronic structure methods in conjunction with accurate quantum dynamical methods, the rovibrational energy levels of a triatomic molecule with two nonhydrogen atoms (HCN) were calculated to unprecedented levels of agreement between theory and experiment.

Dateo, Christopher E.↗

Application of Hilbert-Huang Transform for Improved Defect Detection in Terahertz NDE of Shuttle Tiles

Terahertz NDE is being examined as a method to inspect the adhesive bond-line of Space Shuttle tiles for defects. Terahertz signals are generated and detected, using optical excitation of biased semiconductors with femtosecond laser pulses. Shuttle tile samples were manufactured with defects that included repair regions unbond regions, and other conditions that occur in Shuttle structures. These samples were inspected with a commercial terahertz NDE system that scanned a tile and generated a data set of RF signals. The signals were post processed to generate C-scan type images that are typically seen in ultrasonic NDE. To improve defect visualization the Hilbert-Huang Transform, a transform that decomposes a signal into oscillating components called intrinsic mode functions, was applied to test signals identified as being in and out of the defect regions and then on a complete data set. As expected with this transform, the results showed that the decomposed low-order modes correspond to signal noise while the high-order modes correspond to low frequency oscillations in the signal and mid-order modes correspond to local signal oscillations. The local oscillations compare well with various reflection interfaces and the defect locations in the original signal.

Anastasi, Robert F.↗

Terahertz NDE for Metallic Surface Roughness Evaluation

Metallic surface roughness in a nominally smooth surface is a potential indication of material degradation or damage. When the surface is coated or covered with an opaque dielectric material, such as paint or insulation, then inspecting for surface changes becomes almost impossible. Terahertz NDE is a method capable of penetrating the coating and inspecting the metallic surface. The terahertz frequency regime is between 100 GHz and 10 THz and has a free space wavelength of 300 micrometers at 1 THz. Pulsed terahertz radiation, can be generated and detected using optical excitation of biased semiconductors with femtosecond laser pulses. The resulting time domain signal is 320 picoseconds in duration. In this application, samples are inspected with a commercial terahertz NDE system that scans the sample and generates a set of time-domain signals that are a function of the backscatter from the metallic surface. Post processing is then performed in the time and frequency domains to generate C-scan type images that show scattering effects due to surface non-uniformity.

Madaras, Eric I.↗

New Methods of Sample Preparation for Atom Probe Specimens

Magnetite is a common conductive mineral found on Earth and Mars. Disk-shaped precipitates approximately 40 nm in diameter have been shown to have manganese and aluminum concentrations. Atom-probe field-ion microscopy (APFIM) is the only technique that can potentially quantify the composition of these precipitates. APFIM will be used to characterize geological and planetary materials, analyze samples of interest for geomicrobiology; and, for the metrology of nanoscale instrumentation. Prior to APFIM sample preparation was conducted by electropolishing, the method of sharp shards (MSS), or Bosch process (deep reactive ion etching) with focused ion beam (FIB) milling as a final step. However, new methods are required for difficult samples. Many materials are not easily fabricated using electropolishing, MSS, or the Bosch process, FIB milling is slow and expensive, and wet chemistry and the reactive ion etching are typically limited to Si and other semiconductors. APFIM sample preparation using the dicing saw is commonly used to section semiconductor wafers into individual devices following manufacture. The dicing saw is a time-effective method for preparing high aspect ratio posts of poorly conducting materials. Femtosecond laser micromachining is also suitable for preparation of posts. FIB time required is reduced by about a factor of 10 and multi-tip specimens can easily be fabricated using the dicing saw.

rock varnish↗

Slopes To Prevent Trapping of Bubbles in Microfluidic Channels

The idea of designing a microfluidic channel to slope upward along the direction of flow of the liquid in the channel has been conceived to help prevent trapping of gas bubbles in the channel. In the original application that gave rise to this idea, the microfluidic channels are parts of micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. It is necessary to prevent trapping of gas bubbles in these devices because uninterrupted liquid pathways are essential for sustaining the electrical conduction and flows that are essential for CE. The idea is also applicable to microfluidic devices that may be developed for similar terrestrial microCE biotechnological applications or other terrestrial applications in which trapping of bubbles in microfluidic channels cannot be tolerated. A typical microCE device in the original application includes, among other things, multiple layers of borosilicate float glass wafers. Microfluidic channels are formed in the wafers, typically by use of wet chemical etching. The figure presents a simplified cross section of part of such a device in which the CE channel is formed in the lowermost wafer (denoted the channel wafer) and, according to the present innovation, slopes upward into a via hole in another wafer (denoted the manifold wafer) lying immediately above the channel wafer. Another feature of the present innovation is that the via hole in the manifold wafer is made to taper to a wider opening at the top to further reduce the tendency to trap bubbles. At the time of reporting the information for this article, an effort to identify an optimum technique for forming the slope and the taper was in progress. Of the techniques considered thus far, the one considered to be most promising is precision milling by use of femtosecond laser pulses. Other similar techniques that may work equally well are precision milling using a focused ion beam, or a small diamond-tipped drill bit.

Greer, Harold E.↗

Precision of FLEET Velocimetry Using High-Speed CMOS Camera Systems

Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 microseconds, precisions of 0.5 meters per second in air and 0.2 meters per second in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision HighSpeed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

Peters, Christopher J.↗

Application of FLEET Velocimetry in the NASA Langley 0.3-meter Transonic Cryogenic Tunnel

Femtosecond laser electronic excitation and tagging (FLEET) velocimetry is demonstrated in a large-scale transonic cryogenic wind tunnel. Test conditions include total pressures, total temperatures, and Mach numbers ranging from 15 to 58 psia, 200 to 295 K, and 0.2 to 0.75, respectively. Freestream velocity measurements exhibit accuracies within 1 percent and precisions better than 1 m/s. The measured velocities adhere closely to isentropic flow theory over the domain of temperatures and pressures that were tested. Additional velocity measurements are made within the tunnel boundary layer; virtual trajectories traced out by the FLEET signal are indicative of the characteristic turbulent behavior in this region of the flow, where the unsteadiness increases demonstrably as the wall is approached. Mean velocities taken within the boundary layer are in agreement with theoretical velocity profiles, though the fluctuating velocities exhibit a greater deviation from theoretical predictions.

Burns, Ross A.↗