Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fiber Lens”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A LIBS method for simultaneous monitoring of the impurities and the hydrogenic composition present in the wall of the TJ-II stellarator

The study of plasma-wall interactions and impurity transport in the plasma fusion devices is critical for the development of future fusion reactors. An experiment to perform laser induced breakdown spectroscopy, using minor modifications of our existing laser blow-off impurity injection system, has been set up thus making both experiments compatible. The radiation produced by the laser pulse focused at the TJ-II wall evaporates a surface layer of deposited impurities and the subsequent radiation produced by the laser-produced plasma is collected by two separate lens and fiber combinations into two spectrometers. The first spectrometer, with low spectral resolution, records a spectrum from 200 to 900 nm to give a survey of impurities present in the wall. The second one, with high resolution, is tuned to the wavelengths of the Hα and Dα lines in order to resolve them and quantify the hydrogen isotopic ratio present on the surface of the wall. The alignment, calibration, and spectral analysis method will be described in detail. First experimental results obtained with this setup will be shown and its relevance for the TJ-II experimental program discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A spatially resolved pyrometer for measuring the blackbody temperature of a warm dense plasma

A pyrometer has been developed to spatially resolve the blackbody temperature of a radiatively cooling warm dense plasma. The pyrometer is composed of a lens coupled fiber array, Czerny-Turner visible spectrometer, and an intensified gated CCD for the detector. The radiatively cooling warm dense plasma is generated by a ~100-ns-long intense relativistic electron bunch with an energy of 19.1 MeV and a current of 0.2 kA interacting with 100-μm-thick low-Z foils. The continuum spectrum is measured over 250 nm with a low groove density grating. These plasmas emit visible light or blackbody radiation on relatively long time scales (~0.1 to 100 μs). Finally, we presented the diagnostic layout, calibration, and proof-of-principle measurement of a radiatively cooling aluminum plasma, which includes a spatially resolved temperature gradient and the ability to temporally resolve it also.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robotic Vision for Welding

Vision system for robotic welder looks at weld along axis of welding electrode. Gives robot view of most of weld area, including yet-unwelded joint, weld pool, and completed weld bead. Protected within welding-torch body, lens and fiber bundle give robot closeup view of weld in progress. Relayed to video camera on robot manipulator frame, weld image provides data for automatic control of robot motion and welding parameters.

Richardson, R. W.↗

Luminescence based fiber optic probe for the detection of rare earth elements

The disclosure relates to an apparatus, method and process for detecting rare earth elements. The system includes an LED powered by a first power source and a focusing lens in optical communication with the LED. A shortpass filter is in optical communication with the focusing lens; and a fiber bifurcated cable in optical communication with the shortpass filter. The system includes a probe tip in optical communication with the fiber bifurcated cable and a sample; a first aspheric lens in optical communication with the fiber bifurcated cable. A longpass filter is in optical communication with the first aspheric lens and a second aspheric lens in optical communication with the longpass filter. The system includes a spectrometer connected to a power source, where the spectrometer is in optical communication with the second aspheric lens.

Ahern, John C.↗

Design and fabrication of a coherent array of single-mode optical fibers for the nulling coronagraph

We present the development of a single-mode spatial filter array for the nulling coronagraph application. The development consists of two generations of fiber array designs and a Zygo-interferometer based lens array to fiber array alignment methodology. We discuss the use of large mode field diameter (MFD) fibers to relax fiber placement tolerance of the fiber array. The pros and cons of using the Photonic Crystal Fiber (PCF) for building the array are discussed. The future plan for implementing a 1000-channel class, single-mode spatial filter array is described.

Shao, Mike↗

Dynamic light scattering homodyne probe

An optical probe for analyzing a sample illuminated by a laser includes an input optical fiber operably connectable to the laser where the input optical fiber has an entrance end and an exit end. The probe also includes a first beam splitter where the first beam splitter is adapted to transmit an alignment portion of a light beam from the input fiber exit end and to reflect a homodyning portion of the light beam from the input fiber. The probe also includes a lens between the input fiber exit end and the first beam splitter and a first and a second output optical fiber, each having an entrance end and an exit end, each exit end being operably connectable to respective optical detectors. The probe also includes a second beam splitter which is adapted to reflect at least a portion of the reflected homodyning portion into the output fiber entrance ends and to transmit light from the laser scattered by the sample into the entrance ends.

Meyer, William V.↗

Multipoint photonic doppler velocimetry using optical lens elements

A probe including a fisheye lens is disclosed to measure the velocity distribution of a moving surface along many lines of sight. Laser light, directed to the surface and then reflected back from the surface, is Doppler shifted by the moving surface, collected into fisheye lens, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to an index-matching lens and eventually to a fisheye lens. The fiber array flat polished and coupled to the index-matching lens using index-matching gel. Numerous fibers in a fiber array project numerous rays through the fisheye lens which in turn project many measurement points at numerous different locations to establish surface coverage over a hemispherical shape with very little crosstalk.

47 OTHER INSTRUMENTATION↗

Numerical aperture limits on efficient ball lens coupling of laser diodes to single-mode fibers with defocus to balance spherical aberration

The potential capabilities and limitations of single ball lenses for coupling laser diode radiation to single-mode optical fibers have been analyzed; parameters important to optical communications were specifically considered. These parameters included coupling efficiency, effective numerical apertures, lens radius, lens refractive index, wavelength, magnification in imaging the laser diode on the fiber, and defocus to counterbalance spherical aberration of the lens. Limiting numerical apertures in object and image space were determined under the constraint that the lens perform to the Rayleigh criterion of 0.25-wavelength (Strehl ratio = 0.80). The spherical aberration-defocus balance to provide an optical path difference of 0.25 wavelength units was shown to define a constant coupling efficiency (i.e., 0.56). The relative numerical aperture capabilities of the ball lens were determined for a set of wavelengths and associated fiber-core diameters of particular interest for single-mode fiber-optic communication. The results support general continuing efforts in the optical fiber communications industry to improve coupling links within such systems with emphasis on manufacturing simplicity, system packaging flexibility, relaxation of assembly alignment tolerances, cost reduction of opto-electronic components and long term reliability and stability.

Wilson, R. Gale↗

Compact Packaging of Photonic Millimeter-Wave Receiver

A carrier structure made from a single silicon substrate is the basis of a compact, lightweight, relatively inexpensive package that holds the main optical/electronic coupling components of a photonic millimeter-wave receiver based on a lithium niobate resonator disk. The design of the package is simple and provides for precise relative placement of optical components, eliminating the need for complex, bulky positioning mechanisms like those commonly used to align optical components to optimize focus and coupling. Although a prototype of the package was fabricated as a discrete unit, the design is amenable to integration of the package into a larger photonic and/or electronic receiver system. The components (see figure) include a lithium niobate optical resonator disk of 5-mm diameter and .200- m thickness, positioned adjacent to a millimeter- wave resonator electrode. Other components include input and output coupling prisms and input and output optical fibers tipped with ball lenses for focusing and collimation, respectively. Laser light is introduced via the input optical fiber and focused into the input coupling prism. The input coupling prism is positioned near (but not in contact with) the resonator disk so that by means of evanescent-wave coupling, the input laser light in the prism gives rise to laser light propagating circumferentially in guided modes in the resonator disk. Similarly, a portion of the circumferentially propagating optical power is extracted from the disk by evanescent-wave coupling from the disk to the output coupling prism, from whence the light passes through the collimating ball lens into the output optical fiber. The lens-tipped optical fibers must be positioned at a specified focal distance from the prisms. The optical fibers and the prisms must be correctly positioned relative to the resonator disk and must be oriented to obtain the angle of incidence (55 in the prototype) required for evanescent-wave coupling of light into and out of the desired guided modes in the resonator disk. To satisfy all these requirements, precise alignment features are formed in the silicon substrate by use of a conventional wet-etching process. These features include a 5-mm-diameter, 50- m-deep cavity that holds the disk; two trapezoidal-cross-section recesses for the prisms; and two grooves that hold the optical fibers at the correct positions and angles relative to the prisms and disk. The fiber grooves contain abrupt tapers, near the prisms, that serve as hard stops for positioning the lenses at the focal distance from the prisms. There are also two grooves for prismadjusting rods. The design provides a little slack in the prism recesses for adjusting the positions of the prisms by means of these rods to optimize the optical coupling.

Nguyen, Hung↗

Aquaporin 0 plays a pivotal role in refractive index gradient development in mammalian eye lens to prevent spherical aberration

Highlights: • Intact AQP0 functions as fiber cell-to-fiber cell adhesion protein. • AQP0 facilitates reduction in extracellular space and lens water content. • AQP0 adhesion function aids in lens refractive index gradient (RING) formation. • AQP0 prevents lens spherical aberration by establishing RING. • AQP0 is critical for lens transparency and homeostasis. - Abstract: Aquaporin 0 (AQP0) is a transmembrane channel that constitutes ∼45% of the total membrane protein of the fiber cells in mammalian lens. It is critical for lens transparency and homeostasis as mutations and knockout cause autosomal dominant lens cataract. AQP0 functions as a water channel and as a cell-to-cell adhesion (CTCA) molecule in the lens. Our recent in vitro studies showed that the CTCA function of AQP0 could be crucial to establish lens refractive index gradient (RING). However, there is a lack of in vivo data to corroborate the role of AQP0 as a fiber CTCA molecule which is critical for creating lens RING. The present investigation is undertaken to gather in vivo evidence for the involvement of AQP0 in developing lens RING. Lenses of wild type (WT) mouse, AQP0 knockout (heterozygous, AQP0{sup +/−}) and AQP0 knockout lens transgenically expressing AQP1 (heterozygous AQP0{sup +/−}/AQP1{sup +/−}) mouse models were used for the study. Data on AQP0 protein profile of intact and N- and/or C-terminal cleaved AQP0 in the lens by MALDI-TOF mass spectrometry and SDS–PAGE revealed that outer cortex fiber cells have only intact AQP0 of ∼28 kDa, inner cortical and outer nuclear fiber cells have both intact and cleaved forms, and inner nuclear fiber cells have only cleaved forms (∼26–24 kDa). Knocking out of 50% of AQP0 protein caused light scattering, spherical aberration (SA) and cataract. Restoring the lost fiber cell membrane water permeability (P{sub f}) by transgene AQP1 did not reinstate complete lens transparency and the mouse lenses showed light scattering and SA. Transmission and scanning electron micrographs of lenses of both mouse models showed increased extracellular space between fiber cells. Water content determination study showed increase in water in the lenses of these mouse models. In summary, lens transparency, CTCA and compact packing of fiber cells were affected due to the loss of 50% AQP0 leading to larger extracellular space, more water content and SA, possibly due to alteration in RING. To our knowledge, this is the first report identifying the role of AQP0 in RING development to ward off lens SA during focusing.

60 APPLIED LIFE SCIENCES↗

Development of Parallel Image Detection System Using Annular Pupils for Scanning Transmission Electron Microscope

A parallel image detection system using an annular pupil for electron optics were developed to realize an increase in the depth of focus, aberration-free imaging and separation of amplitude and phase images under scanning transmission electron microscopy (STEM). Apertures for annular pupils able to suppress high-energy electron scattering were developed using a focused ion beam (FIB) technique. The annular apertures were designed with outer diameter of oe 40 {mu}m and inner diameter of oe32 {mu}m. A taper angle varying from 20 deg. to 1 deg. was applied to the slits of the annular apertures to suppress the influence of high-energy electron scattering. Each azimuth angle image on scintillator was detected by a multi-anode photomultiplier tube assembly through 40 optical fibers bundled in a ring shape. To focus the image appearing on the scintillator on optical fibers, an optical lens relay system attached with CCD camera was developed. The system enables the taking of 40 images simultaneously from different scattered directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modulation of lens cell adhesion molecules by particle beams

Cell adhesion molecules (CAMs) are proteins which anchor cells to each other and to the extracellular matrix (ECM), but whose functions also include signal transduction, differentiation, and apoptosis. We are testing a hypothesis that particle radiations modulate CAM expression and this contributes to radiation-induced lens opacification. We observed dose-dependent changes in the expression of beta 1-integrin and ICAM-1 in exponentially-growing and confluent cells of a differentiating human lens epithelial cell model after exposure to particle beams. Human lens epithelial (HLE) cells, less than 10 passages after their initial culture from fetal tissue, were grown on bovine corneal endothelial cell-derived ECM in medium containing 15% fetal bovine serum and supplemented with 5 ng/ml basic fibroblast growth factor (FGF-2). Multiple cell populations at three different stages of differentiation were prepared for experiment: cells in exponential growth, and cells at 5 and 10 days post-confluence. The differentiation status of cells was characterized morphologically by digital image analysis, and biochemically by Western blotting using lens epithelial and fiber cell-specific markers. Cultures were irradiated with single doses (4, 8 or 12 Gy) of 55 MeV protons and, along with unirradiated control samples, were fixed using -20 degrees C methanol at 6 hours after exposure. Replicate experiments and similar experiments with helium ions are in progress. The intracellular localization of beta 1-integrin and ICAM-1 was detected by immunofluorescence using monoclonal antibodies specific for each CAM. Cells known to express each CAM were also processed as positive controls. Both exponentially-growing and confluent, differentiating cells demonstrated a dramatic proton-dose-dependent modulation (upregulation for exponential cells, downregulation for confluent cells) and a change in the intracellular distribution of the beta 1-integrin, compared to unirradiated controls. In contrast, there was a dose-dependent increase in ICAM-1 immunofluorescence in confluent, but not exponentially-growing cells. These results suggest that proton irradiation downregulates beta 1-integrin and upregulates ICAM-1, potentially contributing to cell death or to aberrant differentiation via modulation of anchorage and/or signal transduction functions. Quantification of the expression levels of the CAMs by Western analysis is in progress.

NASA Discipline Radiation Health↗

Near-infrared spectroscopy for divertor plasma diagnosis and control in DIII-D tokamak

New near infrared (NIR) spectroscopic measurements performed in the DIII-D tokamak divertor plasma suggest new viable diagnostic applications: divertor recycling and low-Z impurity flux measurements, a spectral survey for divertor Thomson scattering (DTS) diagnostic, and T{sub e} monitoring for divertor detachment control. A commercial 0.3 m spectrometer coupled to an imaging lens via optical fiber and a InGaAs 1024 pixel array detector enabled deuterium and impurity emission measurements in the range 800–2300 nm. The first full NIR survey identified D, He, B, Li, C, N, O, Ne lines and provided plasma T{sub e}, n{sub e} estimates from deuterium Paschen and Brackett series intensity and Stark line broadening analysis. The range 1.000–1.060 mm was surveyed in high-density and neon seeded divertor plasmas for spectral background emission studies for λ = 1.064 μm laser-based DTS development. The ratio of adjacent deuterium Paschen-α and Brackett Br9 lines in recombining divertor plasmas is studied for divertor T{sub e} monitoring aimed at divertor detachment real-time feedback control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-20: A Novel Hybrid CBCT, Bioluminescence and Fluorescence Tomography System for Preclinical Radiation Research

Purpose: A novel standalone bioluminescence and fluorescence tomography (BLT and FT) system equipped with high resolution CBCT has been built in our group. In this work, we present the system calibration method and validate our system in both phantom and in vivo environment. Methods: The CBCT is acquired by rotating the animal stage while keeping the x-ray source and detector panel static. The optical signal is reflected by the 3-mirror system to a multispectral filter set and then delivered to the CCD camera with f/1.4 lens mounted. Nine fibers passing through the stage and in contact with the mouse skin serve as the light sources for diffuse optical tomography (DOT) and FT. The anatomical information and optical properties acquired from the CBCT and DOT, respectively, are used as the priori information to improve the BLT/FT reconstruction accuracy. Flat field correction for the optical system was acquired at multiple wavelengths. A home-built phantom is used to register the optical and CBCT coordinates. An absolute calibration relating the CCD photon counts rate to the light fluence rate emitted at animal surface was developed to quantify the bioluminescence power or fluorophore concentration. Results: An optical inhomogeneous phantom with 2 light sources (3mm separation) imbedded is used to test the system. The optical signal is mapped onto the mesh generated from CBCT for optical reconstruction. Our preliminary results show that the center of mass can be reconstructed within 2.8mm accuracy. A live mouse with the light source imbedded is also used to validate our system. Liver or lung metastatic luminescence tumor model will be used for further testing. Conclusion: This hybrid system transforms preclinical research to a level that even sub-palpable volume of cells can be imaged rapidly and non-invasively, which largely extends the scope of radiobiological research. The research is supported by the NCI grant R01CA158100-01.

60 APPLIED LIFE SCIENCES↗

OECD MCCI project enhancing instrumentation for reactor materials experiments, Rev. 0 September 3, 2002.

Reactor safety experiments for studying the reactions of a molten core (corium) with water and/or concrete involve materials at extremely high temperature. Such high temperature severely restricts the types of sensors that can be employed to measure characteristics of the corium itself. Yet there is great interest in improving instrumentation so that the state of the melt can be established with more precision. In particular, it would be beneficial to increase both the upper range limit and accuracy of temperature measurements. The poor durability of thermocouples at high temperature is also an important issue. For experiments involving a water-quenched melt, direct measurements of the growth rate of the crust separating the melt and water would be of great interest. This is a key element in determining the nature of heat transfer between the melt and coolant. Despite its importance, no one has been able to directly measure the crust thickness during such tests. This paper considers three specialized sensors that could be introduced to enhance melt characterization: (1) A commercially fabricated, single point infrared temperature measurement with the footprint of a thermowell. A lens assembly and fiber optic cable linked to a receiver and amplifier measures the temperature at the base of a tungsten thermowell. The upper range limit is 3000 C and accuracy is {+-}0.25% of the reading. (2) In-house development of an ultrasonic temperature sensor that would provide multipoint measurements at temperatures up to {approx}3000 C. The sensors are constructed from tungsten rods and have a high temperature durability that is superior to that of thermocouples. (3) In-house development of an ultrasonic probe to measure the growth rate of the corium crust. This ultrasonic sensor would include a tungsten waveguide that transmits ultrasonic pulses up through the corium melt towards the crust and detects reflections from the melt/crust interface. A measurement of the echo time delay would provide the location of the interface. These three sensors would provide a considerable upgrade of the instrumentation used in our reactor materials tests. The infracouple is a commercial product that could provide an immediate improvement in temperature measurements. The sensor could also serve to corroborate thermocouple data by providing a measurement based upon a different physical principle. The ultrasonic temperature sensor would involve a greater investment and longer time frame than the infracouple, but offers all the advantages of the infracouple along with miniaturization and the ability to measure at multiple locations. In addition, the UTS is the platform from which we would begin development of the crust detector. Of the three sensors, the crust detector requires the most effort and entails the greatest uncertainty. However, a real-time crust thickness measurement has never before been made and such data would be unique and of great benefit to reactor materials experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optical Welding Torch

Gas/tungsten-arc welding torch supports electrode at center while enabling viewing of weld area along torch axis. Gas torch accommodates lens and optical fibers, all part of vision system for welding robot. Welding torch includes spoked structure in central bore of optical body. Structure supports welding electrode, carries electric current to it, and takes heat away from it. Spokes formed by drilling six holes 60 degrees apart around center line of torch.

Richardson, R. W.↗

Pulse Response of the Short-Wave Infrared Detection System of the Ocean Color Instrument for the NASA PACE Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission is a hyperspectral Earth imager with a spatial resolution of 1 km x 1 km and a spectral resolution of 5 nm in 2.5 nm steps over 342-887 nm. In addition, OCI provides 7 discrete bands in the 940-2260 nm Short-Wave InfraRed (SWIR) range. The front-end optical imager is a rotating mirror-based system that images the ground scene onto a slit with an instantaneous field of view of 16 km x 1 km. For the SWIR bands, the slit-image is re-imaged onto a 16x1 micro-lens array that effectively acts as the focal plane since each lens element is fiber coupled to wavelength filtered InGaAs and HgCdTe Photo Diodes (PDs). The pulse response of the detection system is critical to OCI SWIR performance. We find that PDs introduce an inherent slow tail in the pulse response due to slow diffusion moving carriers in their n and p regions. We show that this introduces response errors ranging from 1 down to 0.01 % for up to tens of science pixels after the pulse depending on the PD design and materials. It is shown that the response is distinctly different for the InGaAs and HgCdTe PDs. We explain how the front-end design can further increase this error. Finally, we detail the cause of the slow pulse response tail, how to model it, its impact on OCI performance and how it is characterized and corrected to meet OCI requirements.

ocean color↗

Pulse Response of the Short-Wave Infrared Detection System of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission is a hyperspectral Earth imager with a spatial resolution of 1 km x 1 km and a spectral resolution of 5 nm in 2.5 nm steps over 342-887 nm. In addition, OCI provides 7 discrete bands in the 940-2260 nm Short-Wave InfraRed (SWIR) range. The front-end optical imager is a rotating mirror-based system that images the ground scene onto a slit with an instantaneous field of view of 16 km x 1 km. For the SWIR bands, the slit-image is re-imaged onto a 16x1 micro-lens array that effectively acts as the focal plane since each lens element is fiber coupled to wavelength filtered InGaAs and HgCdTe Photo Diodes (PDs). The pulse response of the detection system is critical to OCI SWIR performance. We find that PDs introduce an inherent slow tail in the pulse response due to slow diffusion moving carriers in their n and p regions. We show that this introduces response errors ranging from 1 down to 0.01 % for up to tens of science pixels after the pulse depending on the PD design and materials. It is shown that the response is distinctly different for the InGaAs and HgCdTe PDs. We explain how the front-end design can further increase this error. Finally, we detail the cause of the slow pulse response tail, how to model it, its impact on OCI performance and how it is characterized and corrected to meet OCI requirements.

ocean color↗