Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fiber-optic measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Noncontacting device to indicate deflection of turbopump internal rotating parts

Phase 2 (development) which was concluded for the ultrasonic Doppler device and the light-pipe-reflectance device is reported. An ultrasonic Doppler breadboard system was assembled which accurately measured runout in the J-2 LOX pump impeller during operation. The transducer was mounted on the outside of the pump volute using a C-clamp. Vibration was measured by conducting the ultrasonic wave through the volute housing and through the fluid in the volute to the impeller surface. The impeller vibration was also measured accurately using the light-pipe probe mounted in an elastomeric-gland fitting in the pump case. A special epoxy resin developed for cryogenic applications was forced into the end of the fiber-optic probe to retain the fibers. Subsequently, the probe suffered no damage after simultaneous exposure to 2150 psi and 77 F. Preliminary flash X-radiographs were taken of the turbine wheel and the shaft-bearing-seal assembly, using a 2-megavolt X-ray unit. Reasonable resolution and contrast was obtained. A fast-neutron detector was fabricated and sensitivity was measured. The results demonstrated that the technique is feasible for integrated-time measurements requiring, perhaps, 240 revolutions to obtain sufficient exposure at 35,000 rpm. The experimental verification plans are included.

Hamilton, D. B.↗

Bit error rate measurement for evaluation of a fiber optic link

Digital fiber-optic data-link terminal modules are being developed in a number of laboratories, and often the modules take the form of black boxes without convenient access to internal signals. This paper discusses types of measurements which can be made using only the digital terminals of the link. Bit-error-rate (BER) vs signal-power data can, of course, provide a means for proving overall link performance, but it can also be used to determine certain internal parameters of the receiver. The theoretical dependence of the BER-vs-light-signal-power curve shape on receiver input-noise equivalent power and comparator slicing level is discussed. BER-vs-light-signal-power measurements obtained with an experimental link are presented and interpreted with the aid of the theoretical curves. The effects of other problems, such as hum or oscillation, on the BER data are mentioned. Sensitivity of the system BER to bit rate is also discussed, with application to determining system operating limits. Since BER measurements are simple to make and can easily be automated, they may prove to be a useful means for either laboratory evaluation or production-line acceptance testing of sealed terminal modules.

Bergman, L. A.↗

Planar Rowland spectrometer for fiber-optic wavelength demultiplexing

A planar Rowland spectrometer was fabricated and characterized as a wavelength demultiplexer for multimode fiber-optic applications. The spectrometer consisted of a planar multimode glass waveguide with two curved end faces and a cylindrical concave attached to one of the end faces. Semiconductor lasers with wavelengths between 0.825 and 0.845 micron were used for the measurements. Cross-talk isolation between two adjacent fibers with center-to-center separation of 175 microns (100 A in wavelength difference) was measured to be 18 dB. The device's performance was limited by grating diffraction efficiency, optical aberration, waveguide dispersion, and waveguide losses.

Yen, H. W.↗

Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor

Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment 2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV) neutron fluence of about 3 × 10 21 n/cm 2 . The temperature was intentionally cycled multiple times to compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and investigate possible causes of the sensor behavior observed during irradiation. The postirradiation examination successfully recovered and preserved key WIRE-21 components. After the housing was removed using a milling machine, the internal experiment sections were examined. All eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also removed and stored. The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance measurements of the transceiver coils were also performed. The measurements with irradiated inductor cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements made with unirradiated cores, but the difference was not sufficient to explain the more significant reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An electro-optic, high-voltage, transient probe

A newly developed electro-optic voltage transducer is described. It is capable of measuring 30 ns rise time, floating or single-ended, 0 to 20 kV transients in a high noise environment such as a fast discharge laser or energetic switch system. The voltage transient is detected by a specially developed resistor in series with a light emitting diode. The light output (proportional to voltage) is transmitted remotely via a fiber-optic cable to a detector and recorder. Typical signals and comparison with commercial probe system signals are described.

Posta, S. J.↗

Dynamic Heat Flow and Current Distribution Analysis in the Bottom Anode of an Electric Arc Furnace Using Fiber-Optic Sensors

A reliable method for monitoring bottom anode wear during DC Electric Arc Furnace (DC-EAF) operation is of critical importance for safe and efficient steel production. Underestimation of bottom wear poses a serious safety risk that must be avoided, while overestimation of bottom wear also poses challenges, as premature anode replacement is expensive and affects EAF productivity. Previously, we demonstrated that fiber-optic sensors can be successfully deployed to create a spatially distributed temperature map to monitor the health of the anode. The present work explores the heat flow and current density distribution in bottom anode pins to predict bottom wear, steel penetration events, and monitor refractory erosion. Small dynamic variations in pin temperature induced by joule heating during arcing also provide a means to observe local current flows in each pin. When mapped, these measurements provide a real-time view of the non-uniform and dynamic current flow in the bottom anode during EAF operation that can affect bottom wear.

Bottom Anode↗

Inflight lightning characteristics measurement system

A research data-gathering system being developed for inflight measurement of direct and nearby lightning strike characteristics is described. Wideband analog recorders used to record the lightning scenario are supplemented with high-sample-rate digital transient recorders with augmented memory capacity for increased time resolution of specific times of interest. The endless-loop data storage technique employed by the transient recorders circumvents problems associated with oscilloscopic techniques and allows unattended operation. System integrity and immunity from induced effects is accomplished by fiber-optics signal-transmission links, shielded system enclosures, and the use of a dynamotor for power system isolation.

Pitts, F. L.↗

Near-Real-Time Material Tracking: Combining Vis–NIR Spectroscopy with Flow Sensing for Accurate Nd(III) Quantification

A fiber-optic visible–near-infrared (vis–NIR) absorption spectroscopy and flow sensor system has been developed for near-real-time tracking of Nd mass in the effluent stream from a column in a fume hood. The approach leverages two unique data streams and a partial least-squares regression (PLSR) model trained on vis–NIR absorption spectra of Nd(III) (0–1.5 M) in 1 M HNO 3 . In-line volumetric flow rate and vis–NIR spectra are measured in sequence after a chromatography column. The time stamps from each data stream are then synchronized, which allows integrated volumes to be combined with Nd(III) molarities predicted by a PLSR model to accurately calculate the Nd mass flowing through the column. This integrated measurement provides instantaneous mass flow and accumulates these data over time to obtain the total mass processed. The methodology developed in this study contributes critical technical infrastructure to improve monitoring capabilities to support chemical separations and the production of strategic materials and isotopes.

Irvine, Sawyer B. [Oak Ridge National Laboratory (↗

AC Magnetometry Using Nano-ferrofluid Cladded Multimode Interferometric Fiber Optic Sensors for Power Grid Monitoring Applications

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored. Instead, the incorporation of nano-ferrofluid as sensing materials has been only limited to DC magnetic field sensing, often citing their long response time as a limiting factor to AC field sensing. This work reports the finding of high frequency (up to 15 kHz) AC magnetic field sensing capability of nanomagnetic fluid as the cladding material of a fiber-optic multimode interferometry (MMI) structure optimized for the fourth self-imaging spectral response. The key parameter enabling high frequency response is the short response time (<1 ms) achieved by optimizing both the sensing structure and nano-ferrofluid solution. Focus has been imparted on 60 Hz line-frequency profiles of various current/magnetic fields to test the efficacy of these sensors in metering and monitoring current and current-induced magnetic fields in the electrical power grid systems. The magnetic field sensitivity of 240 mV/Gauss per dBm of transmitted power was achieved for 60 Hz field applied via Helmholtz coil, whereas the 60 Hz AC current sensitivity of 2.83 mV/A was measured due to magnetic field induced by current in a straight conducting wire.

42 ENGINEERING↗

Glassy carbon formation from pyrolysis of polymeric coatings on fiber-optic sensors

Deploying fiber-optic sensors in nuclear reactors requires a detailed understanding of radiation effects on the fiber materials and the transmitted signals. Previous work has shown large wavelength shifts in the reflected spectra obtained from polymer-coated fiber-optic temperature sensors exposed to high neutron fluences. The sensor drift resulting from these wavelength shifts cannot be explained by radiation effects on fused silica glass. These shifts are hypothesized to be caused by the conversion of the polymeric fiber coating to a glassy carbon via radiolysis and/or pyrolysis and subsequent radiation-induced compaction. Here, thermal degradation of these polymeric coatings was studied to provide insight into the potential origins of the sensor drift phenomenon. Acrylate- and polyimide-coated fibers were heated under various temperatures (250–1300 °C) and environments (oxidative and inert), and the resulting coating products were characterized via mass-loss data, scanning electron microscope imaging, and Raman spectroscopy. Results suggest that the polymer decomposition product of both coating types, at least under inert conditions, is indeed a glassy carbon. Analytical models that account for radiation-induced glassy carbon coating compaction show significant compressive fiber strains and predicted wavelength shifts that agree well with experimental measurements, providing additional evidence that supports the hypothesized origins of the sensor drift.

36 MATERIALS SCIENCE↗

Dual-mode fiber-optic refractive-index gas thermometry with primary anchoring and continuous temperature tracking

Extending fiber-optic refractive-index gas thermometry beyond primary-only operation, we report a dual-mode argon-filled Fabry-Perot thermometer in which the same cavity first establishes a primary temperature anchor and then performs continuous secondary-mode tracking. The primary anchor is obtained from two-pressure fringe shifts using a virial-coefficient refractivity model. During secondary operation, pressure cycling is stopped, and temperature is recovered from the monitored fringe wavelength and gas pressure using a model that includes argon refractivity, pressure-induced cavity strain, and fused-silica thermal expansion. From 310 to 1013 K, secondary-mode temperatures agreed with a reference thermocouple with 0.21 K RMSE and 0.47 K maximum error; 45-min natural furnace cooldowns were also tracked from nearby anchors with close agreement. The dual-mode method retains the empirical-calibration-free primary measurement as an in-situ reference while enabling simpler continuous tracking between anchors, addressing a practical limitation of primary-only fiberoptic refractive-index gas thermometry for hightemperature applications.

Syed, Musaddeque [Michigan State University, East ↗

Origins of radiation-induced optical attenuation in neutron-irradiated single-crystal sapphire at elevated temperatures

Sapphire (α-Al 2 O 3 ) is a candidate fiber-optic sensor material for extreme temperature environments, potentially including those of nuclear reactors. However, its optical transmission under high-dose neutron irradiation is not well understood compared with that of conventional fused silica. This study examined dimensional changes, optical transmission, and irradiation-induced defects in neutron-irradiated α-Al 2 O 3 at temperatures of 298 °C to 688 °C and doses of 3.2 to 12 dpa. Although previous studies attributed radiation-induced attenuation (RIA) at the highest irradiation temperatures to increased optical scattering from radiation-induced voids, our findings indicate that scattering from neither voids nor dislocation loops can explain the measured attenuation. Instead, absorption due to aluminum vacancy centers appears more likely based on a comparison of the spectral features of the measured optical attenuation with previous literature. Significant c-axis swelling (5.51 % ± 0.83 %) was observed in the 12 dpa, 592 °C irradiated sample, much higher than earlier measurements, suggesting temperature sensor drift of 543 °C to 1,140 °C. Void patterning was predominantly observed along the a-axis, differing from previous studies on polycrystalline samples, which showed c-axis patterning. Dislocation loops evolved into network dislocations with increasing temperature and dose; voids formed within these structures, showing no size or density changes, indicating an atypical growth mechanism.

Neutron irradiation↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

Birefringence axis rotation and nonlinear response of a side-hole fiber pressure sensor

The pressure-induced birefringence of side-hole fibers has been widely explored for hydrostatic pressure measurement. Here, this paper studies the effects of the initial birefringence of a side-hole fiber on the pressure response of polarimetric sensors based on side-hole fibers. A mathematical model, where the stress field induced by the pressure is assumed to be uniform in the core region of the fiber, was established to calculate the birefringence and optical axis rotation as a function of the differences between the two principal stress components of the stress field in the core region. Simulation results show that when there is misalignment between the initial birefringence axes and the principal axes of the stress field, pressure changes cause rotations of the birefringence axis, leading to complicated and nonlinear changes of birefringence as a function of pressure. Experiments were conducted using fiber-Bragg-grating-based resonators on side-hole fibers with different initial birefringence, and the results agree well with the simulation. The results underscore the importance of the control of magnitude and direction of the initial birefringence of the side-hole fiber and provide guidelines for the design and fabrication of side-hole fiber pressure sensors.

42 ENGINEERING↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

Exploring the Feasibility of Modern Fiber Optics in Offshore Mooring Condition Monitoring

This project explored the feasibility of using fiber-optic sensing technologies for condition monitoring of offshore synthetic mooring lines used in marine renewable energy systems. The work focused on evaluating optical fiber materials, interrogation methods, and rope-embedment approaches capable of enabling distributed strain or elongation measurements along mooring lines.

16 TIDAL AND WAVE POWER↗

Design and fabrication of engineering model fiber-optics detector

The design and fabrication of an annular ring detector consisting of optical fibers terminated with photodetectors is described. The maximum width of each concentric ring has to be small enough to permit the resolution of a Ronchi ruling transform with a dot spacing of 150 microns. A minimum of 100 concentric rings covering a circular area of 2.54 cm diameter also is necessary. A fiber-optic array consisting of approximately 89,000 fibers of 76 microns diameter was fabricated to meet the above requirements. The fibers within a circular area of 2.5 cm diameter were sorted into 168 adjacent rings concentric with the center fiber. The response characteristics of several photodetectors were measured, and the data used to compare their linearity of response and dynamic range. Also, coupling loss measurements were made for three different methods of terminating the optical fibers with a photodetector.

Mcsweeney, A.↗

Space optics; Proceedings of the Seminar, Huntsville, Ala., May 22-24, 1979

The seminar focused on infrared systems, the space telescope, new design for space astronomy, future earth resources systems, and planetary systems. Papers were presented on infrared astronomy satellite, infrared telescope on Spacelab 2, design alternatives for the Shuttle Infrared Telescope Facility, Spacelab 2 infrared telescope cryogenic system, geometrical theory of diffraction and telescope stray-light analysis, Space Telescope scientific instruments, faint-object spectrograph for the Space Telescope, light scattering from multilayer optics, bidirectional reflectance distribution function measurements of stray light suppression coatings for the Space Telescope, optical fabrication of a 60-in. mirror, interferogram analysis for space optics, nuclear-pumped lasers for space application, geophysical fluid flow experiment, coherent rays for optical astronomy in space, optical system with fiber-optical elements, and Pioneer-Venus solar flux radiometer.

Wyman, C. L.↗