Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Filtration Performance of Layering Masks and Face Coverings and the Reusability of Cotton Masks after Repeated Washing and Drying

In this study, filtration efficiency of different respirators, face masks, and a 2-ply cotton handkerchief bandana was compared for particles in the size range of 60 nm-4 um under a "perfect fit" condition. The filtration efficiency at the most penetrating particle size of 0.3 um on average ranged from 83-99% for N95 and KN95 respirators, 42-88% for surgical masks, 16-23% for cloth masks, and 9% for bandana. We also investigated the effects of using double surgical masks or layering a cloth mask over various surgical masks in terms of their filtration characteristics. In most of these combinations, the filtration efficiency improved by ~25% for particles 0.3-1 um in diameter without any substantial change in the filter quality factor when compared to the highest of the individual mask results. To investigate the reusability of cotton cloth masks, 2-layer cotton fabric sample coupons were machine washed and dried for 52 cycles leading to an increase in inhalation resistance (~20 Pa) without affecting size-resolved filtration efficiency. Scanning electron microscopy revealed that washing and drying led to the gradual deconstruction of cotton fibers at the scale of several micrometers to hundreds of nanometers in the form of delamination of the fiber wall and fibrillation of the nanofiber constituents. Results indicate that cloth masks may be layered over surgical masks for additional benefits, and that cloth masks made out of cotton fabric can be washed and reused numerous times without a significant loss in filtration efficiency.

99 GENERAL AND MISCELLANEOUS↗

Graphene-Based Filtration Media for Spacecraft Potable Water Systems: An Early Investigation

Graphene-based materials have allowed fundamental advances in fields such as energy storage, electronics development, material science, optics, medicine, and water processing due to their unique two-dimensional structure, mechanical robustness, large surface, and high conductivity. However, little to no effort has been devoted to exploiting and studying these materials to develop new water technologies suited for spacecraft applications. One such application is the potential use of graphene-based materials as filtration media for reclaimed water. Therefore, studying the adsorptive performance of these new materials becomes crucial in identifying the opportunity to replace/upgrade state-of-the-art filtration media currently used in space vehicles with water recovery capability; especially if consumable requirements can be lessened as a result of extended filtration capacity. This early Life-Support-Systems investigation pioneers in graphene research by testing a number of graphene-based materials in comparative adsorption and antimicrobial experiments where contaminant removal efficiency, maximum adsorption capacity, and bacterial reduction are probed. This preliminary investigation informs on the practicality of using graphene-based materials as filtration media and provides a discussion on the scaling-up and optimization of this prospective filtration technology for spacecraft potable water systems.

graphene↗

Household Materials Selection for Homemade Cloth Face Coverings and Their Filtration Efficiency Enhancement with Triboelectric Charging

The COVID-19 pandemic is currently causing a severe disruption and shortage in the global supply chain of necessary personal protective equipment (e.g., N95 respirators). The U.S. CDC has recommended use of household cloth by the general public to make cloth face coverings as a method of source control. We evaluated the filtration properties of natural and synthetic materials using a modified procedure for N95 respirator approval. Common fabrics of cotton, polyester, nylon, and silk had filtration efficiency of 5–25%, polypropylene spunbond had filtration efficiency 6–10%, and paper-based products had filtration efficiency of 10–20%. An advantage of polypropylene spunbond is that it can be simply triboelectrically charged to enhance the filtration efficiency (from 6 to >10%) without any increase in pressure (stable overnight and in humid environments). Using the filtration quality factor, fabric microstructure, and charging ability, we are able to provide an assessment of suggested fabric materials for homemade facial coverings.

36 MATERIALS SCIENCE↗

Aerosol Filtration Efficiency of Common Fabrics Used in Respiratory Cloth Masks

The emergence of a pandemic affecting the respiratory system can result in a significant demand for face masks. This includes the use of cloth masks by large sections of the public, as can be seen during the current global spread of COVID-19. However, there is limited knowledge available on the performance of various commonly available fabrics used in cloth masks. Importantly, there is a need to evaluate filtration efficiencies as a function of aerosol particulate sizes in the 10 nm – 10 µm range, which is particularly relevant for respiratory virus transmission. We have carried out these studies for several common fabrics including cotton, silk, chiffon, flannel, various synthetics, and their combinations. While the filtration efficiencies for various fabrics when a single layer was used ranged from 5-80% and 15-95% for particle sizes <300 nm and >300 nm respectively, the efficiencies improved when multiple layers were used, and when using a specific combination of different fabrics. Filtration efficiencies of the hybrids (such as cotton-silk, cotton-chiffon, cotton-flannel) was >80 % (for particles <300 nm) and >90 % (for particles >300 nm). We speculate that the enhanced performance of the hybrids is likely due to the combined effect of mechanical and electrostatic-based filtration. Cotton, the most widely used material for cloth masks performs better at higher weave densities (i.e., threads per inch) and can make a significant difference in filtration efficiencies. Our studies also imply that gaps (as caused by an improper fit of the mask) can result in over a 60% decrease in the filtration efficiency, implying the need for future cloth mask design studies to take into account issues of “fit” and leakage, while allowing the exhaled air to vent efficiently. Overall, we find that combinations of various commonly available fabrics used in cloth masks can potentially provide significant protection against the transmission of aerosol particles.

36 MATERIALS SCIENCE↗

Glomerular filtrate proteins in acute cardiorenal syndrome

Acute cardiorenal syndrome (CRS-1) is a morbid complication of acute cardiovascular disease. Heart-to-kidney signals transmitted by “cardiorenal connectors” have been postulated, but investigation into CRS-1 has been limited by technical limitations and a paucity of models. To address these limitations, we developed a translational model of CRS-1, cardiac arrest and cardiopulmonary resuscitation (CA/CPR), and now report findings from nanoscale mass spectrometry proteomic exploration of glomerular filtrate 2 hours after CA/CPR or sham procedure. Filtrate acquisition was confirmed by imaging, molecular weight and charge distribution, and exclusion of protein specific to surrounding cells. Filtration of proteins specific to the heart was detected following CA/CPR and confirmed with mass spectrometry performed using urine collections from mice with deficient tubular endocytosis. Cardiac LIM protein was a CA/CPR-specific filtrate component. Cardiac arrest induced plasma release of cardiac LIM protein in mice and critically ill human cardiac arrest survivors, and administration of recombinant cardiac LIM protein to mice altered renal function. These findings demonstrate that glomerular filtrate is accessible to nanoscale proteomics and elucidate the population of proteins filtered 2 hours after CA/CPR. The identification of cardiac-specific proteins in renal filtrate suggests a novel signaling mechanism in CRS-1. We expect these findings to advance understanding of CRS-1.

Wakasaki, Rumie (ORCID:0000000202291919)↗

Fiscal Year 2019 Filtration of Hanford Tank AP-107 Supernatant

Bench-scale filtration testing of 9 liters of 241-AP-107 supernatant was conducted using two different filters in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. The following filters were tested: (1) Mott inline filter Model 6480 (media grade 5) (also known as the backpulsed dead-end filter, BDEF) (2) Mott 70-mm disc filter (media grade 5) (also known as the dead-end filter, DEF) The BDEF was used to filter approximately 7 liters of AP-107 at a targeted flux of 0.065 gpm/ft 2 and exhibited no measurable pressure increase during filtration. The BDEF was backpulsed after 17.5 hours of filtration and no solids were observed in the backpulse concentrate. The DEF was used to filter 2 liters of AP-107 feed and no increase in filter resistance was measured and no solids were observed on the filter at the conclusion of filtration. Results are in contrast to similar filtration testing of 241-AP-107 supernatant received in fiscal year 2018, where solids were observed and collected and caused a measurable increase in filtration resistance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY 23 Filtration of Hanford Tank 241-SY-101 Supernatant at 16 °C

Approximately 9 liters of supernatant from Hanford waste tank 241-SY-101 was delivered by Washington River Protection Solutions to the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory. The thirty-six SY-101 sample bottles were comprised of six sets of six samples, with each set pulled from a unique tank sampling level. Prior to testing, samples from each level were composited to provide nominally level-independent feed for dead end filtration and ion exchange testing. The composited 241-SY-101 supernatant was chilled to 16 °C for 1 week prior to testing. Filtration testing was then conducted using a backpulse dead-end filter (BDEF) system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the RPL. This was done to provide waste processing benchmarks for 200 West Area wastes in the West Area Risk Management project. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 . During filtration of the differential pressure required to effect filtration at 0.065 gpm/ft 2 increased little over the filtration campaign and never reached 2 psid (the Tank Side Cesium Removal system action limit). This indicates that the Media Grade 5 filter should perform well when processing SY-101 supernatant. After completing filtration of the SY-101 feed, the filter was cleaned. Solids concentrated from the backpulse solutions displayed calcium phosphate, aluminum oxides, aluminum-chromium nanoparticle agglomerates. Electron diffraction was used to determine the types of phases that were present in the solids. Most of the phases found were only weakly crystalline, possibly owing to their rapid precipitation during the process water treatment. The identifications of the phases therefore are tentative.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Filtration Combustion in Smoldering and SHS

Smolder waves and SHS (self-propagating high-temperature synthesis) waves are both examples of filtration combustion waves propagating in porous media. Smoldering combustion is important for the study of fire safety. Smoldering itself can cause damage, its products are toxic and it can also lead to the more dangerous gas phase combustion which corresponds to faster propagation at higher temperatures. In SHS, a porous solid sample, consisting of a finely ground powder mixture of reactants, is ignited at one end. A high temperature thermal wave, having a frontal structure, then propagates through the sample converting reactants to products. The SHS technology appears to enjoy a number of advantages over the conventional technology, in which the sample is placed in a furnace and "baked" until it is "well done". The advantages include shorter synthesis times, greater economy, in that the internal energy of the reactions is employed rather than the costly external energy of the furnace, purer products, simpler equipment and no intrinsic limitation on the size of the sample to be synthesized, as exists in the conventional technology. When delivery of reactants through the pores to the reaction site is an important aspect of the combustion process, it is referred to as filtration combustion. The two types of filtration combustion have a similar mathematical formulation, describing the ignition, propagation and extinction of combustion waves in porous media. The goal in each case, however, is different. In smoldering the desired goal is to prevent propagation, whereas in SHS the goal is to insure propagation of the combustion wave, leading to the synthesis of desired products. In addition, the scales in the two areas of application differ. Smoldering generally occurs at lower temperatures and propagation velocities than in SHS. Nevertheless, the two applications have much in common, so that what is learned in one application can be used to advantage in the other. We have considered a number of problems involving filtration combustion. Here we describe two such studies: (A) fingering instabilities in filtration combustion, (B) rapid filtration combustion waves driven by convection.

Matkowsky, Bernard↗

Separation of Refined Silicon from Al-Si Alloys by Air Pressure Filtration

The separation of refined silicon from Al-Si alloys through a solvent refining process was studied. Purified silicon particles were separated by air pressure filtration using stainless steel sieves as the filtration media. After the efficient removal of impurities in the refining process, the effects of the mesh number (N), separation temperature (T), silicon content in the alloy (ω{sub (a)}), and pressure differential (p) on the separation efficiency were evaluated. At N = 80, T = 873 K (600 °C), ω{sub (a)} = 45 wt pct and p = 0.25 MPa, the recovery rate of refined silicon was 98.2 pct, and the residual aluminum in the separated silicon was less than 8 wt pct. The separation process was efficient when N = 60 to 150. It was advisable for the separation temperature to approach the eutectic temperature. Efficient filtration could be achieved when ω{sub (a)} = 35 to 55 wt pct. The filtration efficiency was improved with a higher pressure differential, and the separation was efficient at p ≥ 0.10 MPa. The results show that air pressure filtration is a promising method to separate refined silicon.

36 MATERIALS SCIENCE↗

Numerical investigations to identify environmental factors for field-scale reactive transport of pathogens at riverbank filtration sites

While induced bank filtration is a proven method for facilitating sustainable drinking water production, it is at risk from surface water contaminations (e.g., pathogens). Induced bank filtration and pathogen transport in groundwater have been studied extensively. However, long-term studies that consider real-world conditions are missing. These conditions include seasonal changes to environmental conditions and waterworks operations. Therefore, to analyze the effect of seasonal changes on the transport of human pathogenic viruses and their indicators in induced bank filtration, concentrations of adenoviruses and pathogen indicators were monitored over 16 months at an active bank filtration plant at the Rhine River, in Düsseldorf (Germany). Based on this data, a 2D groundwater model was created in PFLOTRAN that simulated flow, heat transport, conservative transport of chloride and the resulting electrical conductivity, reactive transport of oxygen and nitrate, and colloid-based transport of coliforms, somatic coliphages, and adenoviruses. The results show that reduced travel time was the key factor determining periods with a low removal of coliforms and somatic coliphages in the aquifer. Travel time was controlled by river level variations during rainy seasons, and the waterworks extraction rates during dry seasons. Further, for adenovirus transport, travel distance in the subsurface appeared to be the key factor, while travel time had no significant impact. Coliform removal increased when the colmation layer permeability decreased, while coliphage and adenovirus removal was unaffected by the colmation layer permeability. Seasonal changes in temperature and oxygen content did not significantly impact the removal of coliphages and adenoviruses in groundwater. Denitrifying conditions correlated with a lowered coliform removal, but the modelling could not establish a connection between denitrifying conditions and coliform removal. Our study showed that removal of pathogens and pathogen indicators at induced bank filtration plants varies greatly in time and space (e.g., for coliforms from 1 to 4 log-levels at 20m travel distance), and that adenovirus transport differs considerably from transport of coliforms and somatic coliphages.

59 BASIC BIOLOGICAL SCIENCES↗

Selective capture and recovery of uranium oxide colloids from aqueous soil suspensions using high gradient magnetic filtration

High Gradient Magnetic Filtration (HGMF) is a promising method for the selective capture and recovery of uranium oxide from surface soils. To date, however, magnetic filtration of uranium oxide has only been demonstrated at a proof-of-principle scale using relatively small filters (<5 cm 3 ) at low flowrates (<60 mL/min). Here, to explore the efficacy of magnetic filtration of uranium oxide at a larger scale, a newly designed HGMF apparatus that is more than an order of magnitude larger than our earlier filters (106 cm 3 ) was designed, fabricated, and tested at relatively high flowrates. Filtration experiments were performed using aqueous uranium oxide particle suspensions with Arizona Road Dust (ARD) as a soil simulant. At a flowrate of 125 mL/min, the apparatus’ uranium capture rate was exceptionally high (96 %), but selectivity was poor due to the high rate of capture for diamagnetic soil constituents (e.g., 77 % for silicon). All particles were captured at a lower rate when the flowrate was increased to 250 mL/min, but uranium selectivity was significantly increased due to the more substantial reduction in diamagnetic particle capture (i.e., capture rate of 77 % and 15 % for uranium and silicon, respectively). When backwashing the apparatus at the same flowrates used during filtration experiments, the rate of uranium recovery tended to be fairly low. Nevertheless, higher flowrates (1 L/min) and sonication were both shown to be highly effective methods of increasing uranium recovery. Magnetic field simulations were also performed to investigate potential optimizations to the design of the apparatus. These simulations showed that the intensity of the applied magnetic field could be increased by increasing the thickness of the steel magnetic housing. Additionally, stochastic trajectory simulations were performed to investigate the potential mechanisms of particle capture.

HGMF↗

Exploration Mission Particulate Matter Filtration Technology Performance Testing in a Simulated Spacecraft Cabin Ventilation System

Human deep space exploration missions will require advances in long-life, low maintenance airborne particulate matter filtration technology. As one of the National Aeronautics and Space Administrations (NASA) developments in this area, a prototype of a new regenerable, multi-stage particulate matter filtration technology was tested in an International Space Station (ISS) module simulation facility. As previously reported, the key features of the filter system include inertial and media filtration with regeneration and in-place media replacement techniques. The testing facility can simulate aspects of the cabin environment aboard the ISS and contains flight-like cabin ventilation system components. The filtration technology test article was installed at the inlet of the central ventilation system duct and instrumented to provide performance data under nominal flow conditions. In-place regeneration operations were also evaluated. The real-time data included pressure drop across the filter stages, process air flow rate, ambient pressure, humidity and temperature. In addition, two video cameras positioned at the filtration technology test articles inlet and outlet were used to capture the mechanical performance of the filter media indexing operation under varying air flow rates. Recent test results are presented and future design recommendations are discussed.

particulate matter filtration↗

Graphene-Based Filtration Media for Spacecraft Potable Water Systems: An Early Investigation

Graphene-based materials have allowed fundamental advances in fields such as energy storage, electronics development, material science, optics, medicine, and water processing due to its unique two-dimensional structure, mechanical robustness, large surface, and high conductivity. However, little to no effort has been devoted to exploiting and studying these materials to develop new water technologies suited for spacecraft applications. One such application is the potential use of graphene-based materials as filtration media for reclaimed water. Therefore, studying the adsorptive performance of these new materials becomes crucial in identifying the opportunity to replace/upgrade State-of-the-Art filtration media currently used in space vehicles with water-recovery capability; especially if consumable requirements can be lessened as a result of extended filtration capacity. This early life-support-systems investigation pioneers in graphene-research by testing a number of graphene-based materials in comparative adsorption and antimicrobial experiments where contaminant removal efficiency, maximum adsorption capacity, and log reduction are probed. This preliminary investigation informs on the practicability of using graphene-based materials as filtration media and provides a discussion on the scaling-up and optimization of this prospective filtration technology for spacecraft potable water systems.

graphene↗

Graphene-Based Filtration Media for Spacecraft Potable Water Systems: An Early Investigation

Graphene-based materials have allowed fundamental advances in fields such as energy storage, electronics development, material science, optics, medicine, and water processing due to their unique two-dimensional structure, mechanical robustness, large surface, and high conductivity. However, little to no effort has been devoted to exploiting and studying these materials to develop new water technologies suited for spacecraft applications. One such application is the potential use of graphene-based materials as filtration media for reclaimed water. Therefore, studying the adsorptive performance of these new materials becomes crucial in identifying the opportunity to replace/upgrade state-of-the-art filtration media currently used in space vehicles with water recovery capability; especially if consumable requirements can be lessened as a result of extended filtration capacity. This early Life-Support-Systems investigation pioneers in graphene research by testing a number of graphene-based materials in comparative adsorption and antimicrobial experiments where contaminant removal efficiency, maximum adsorption capacity, and bacterial reduction are probed. This preliminary investigation informs on the practicality of using graphene-based materials as filtration media and provides a discussion on the scaling-up and optimization of this prospective filtration technology for spacecraft potable water systems.

graphene↗

Research Update: Liquid gated membrane filtration performance with inorganic particle suspensions

Membrane filtration technology is widely used across several industries. But its efficiency is plagued by fouling, which ultimately deteriorates the membrane’s performance. This paper provides a research update on the biologically inspired liquid-enabled gating mechanism that acts as a novel filtration and separation approach offering reduction in transmembrane pressure (TMP), improved throughput, and reduced fouling. We study the performance of such Liquid Gated Membranes (LGMs) and present their benefits for filtration in the presence of model inorganic (nanoclay particles) fouling. We show over twofold higher throughput, nearly threefold longer time to foul, more than 60% reduction in irreversible fouling, ability to return to baseline pressures after backwashing along with reduction in use of backwash water, and 10%-15% reduction in TMP for filtration of nanoclay particles. Fouling models exhibit not only delayed onset of fouling for LGMs compared to the control but also different fouling characteristics. These results demonstrate the potential of the liquid gating mechanism, which can lead to breakthroughs in membrane technology applications in particle filtration, microfiltration, and ultrafiltration.

36 MATERIALS SCIENCE↗

Assessment of a Filtration Waste Qualification Method for LAWPS

The Low-Activity Waste Pretreatment System (LAWPS) facility is planned to pretreat Hanford tank waste supernate by filtering solids and processing through ion exchange columns to remove cesium. The filtration process is achieved through cross flow filtration using a stainless steel Mott filter with a 0.1-micron grade. The goal of this effort was to assess whether a batch, or dead end, filtration (DEF) device replicating the LAWPS cross flow filter could be employed to qualify each feed campaign prior to delivery to LAWPS. The objective for filtration feed qualification is to determine whether the cross-flow filters deployed in LAWPS will remove solids while maintaining a de minimus flow rate of permeate. To that end, the DEF was tested with simulants and the results compared with those obtained from cross flow filtration tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NSRD-20, Functional Testing of Novel MTC HEPA Filtration Media

To improve the safety of Department of Energy (DOE) nuclear facilities, this project aimed to develop ceramic high efficiency particulate air (HEPA) filters that also create a low pressure-drop (dP) in use. The filters under consideration use mini-tubular ceramic (MTC) HEPA filtration media made with different architectures. Once successful, this project will reduce life-cycle costs, including safety basis, operational, and waste-disposal costs. The technology’s mini-tubular geometry is known to reduce dP when compared to flow through membranes of equivalent mass and surface area. Low dP facilitates retrofitting advanced filters into existing DOE facilities to make them safer while simultaneously reducing operational costs. Operations of ventilation systems are a key cost driver for DOE nuclear facilities; reducing dP can significantly reduce DOE’s operational costs. However, the filtration efficiency (FE) of this type of filtration media depends on the architecture of the filter media in an unknown way and requires testing. Functional testing of filtration media with different architectures will establish the performance of the filtration media and will enable development of guidance on design requirements to optimize filter performance.

36 MATERIALS SCIENCE↗

Effect of filtration on rolling-element-bearing life in contaminated lubricant environment

Fatigue tests were conducted on groups of 65 millimeter-bore ball bearings under four levels of filtration with and without a contaminated MIL-L-23699 lubricant. The baseline series used noncontaminated oil with 49 micron absolute filtration. In the remaining tests contaminants of the composition found in aircraft engine filters were injected into the filter's supply line at a constant rate of 125 milligrams per bearing-hour. The test filters had absolute particle removal ratings of 3, 30, 49, and 105 microns (0.45, 10, 30, and 70 microns nominal), respectively. Bearings were tested at 15,000 rpm under 4580 newtons radial load. Bearing life and running tract condition generally improved with finer filtration. The 3 and 30 micron filter bearings in a contaminated lubricant had statistically equivalent lives, approaching those from the baseline tests. The experimental lives of 49 micron bearings were approximately half the baseline bearing's lives. Bearings tested with the 105 micron filter experienced wear failures. The degree of surface distress, weight loss, and probable failure mode were found to be dependent on filtration level, with finer filtration being clearly beneficial.

Loewenthal, S. H.↗