Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flight Demonstration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗

Tailoring the Physicochemical Properties of Nb Thin Films via Surface Engineering Methods

The modification of surface oxide layers formed on niobium (Nb) thin films via chemical mechanical planarization (CMP) and accelerated neutral atom beam (ANAB) processing provides a promising route toward tailoring their emergent properties and performance when used as superconducting qubits. Here, in this study, we show that CMP- and ANAB-formed Nb oxides are significantly thinner and smoother than the native oxide, as revealed by transmission electron microscopy (TEM) and atomic force microscopy. Scanning TEM and energy-dispersive X-ray spectroscopy along with X-ray photoelectron spectroscopy identified an oxidation gradient within the native and surface-engineered oxides. The topside layer is dominated by Nb 5+ (Nb 2 O 5 ), with various Nb suboxides present closer to the oxide/metal interface. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) depth profiling confirmed the presence of an oxygen content gradient and demonstrated the enhanced resistance of the CMP- and ANAB-formed oxides to oxygen surface exchange and subsequent diffusion via 18 O 2 isotopic labeling experiments. ToF-SIMS also identified an interfacial layer containing trapped hydrogen (H)-containing species at the Nb oxide/metal interface. In situ ToF-SIMS and TEM revealed migration of the H/OH interfacial layer coinciding with decomposition of the surface oxide. Furthermore, our density functional theory calculations indicated that both H from moisture present in ambient air and bulk H in Nb films tend to segregate at the interface. These findings underscore the importance of understanding surface oxidation mechanisms, hydrogen incorporation, and their impact on the designed functionalities of Nb-based devices.

36 MATERIALS SCIENCE↗

Delineating the Impact of Transition‐Metal Crossover on Solid‐Electrolyte Interphase Formation with Ion Mass Spectrometry

Abstract Lithium‐metal batteries (LMB) employing cobalt‐free layered‐oxide cathodes are a sustainable path forward to achieving high energy densities, but these cathodes exhibit substantial transition‐metal dissolution during high‐voltage cycling. While transition‐metal crossover is recognized to disrupt solid‐electrolyte interphase (SEI) formation on graphite anodes, experimental evidence is necessary to demonstrate this for lithium‐metal anodes. In this work, advanced high‐resolution 3D chemical analysis is conducted with time‐of‐flight secondary‐ion mass spectrometry (TOF‐SIMS) to establish spatial correlations between the transition metals and electrolyte decomposition products found on cycled lithium‐metal anodes. Insights into the localization of various chemistries linked to crucial processes that define LMB performance, such as lithium deposition, SEI growth, and transition‐metal deposition are deduced from a precise elemental and spatial analysis of the SEI. Heterogenous transition‐metal deposition is found to perpetuate both heterogeneous SEI growth and lithium deposition on lithium‐metal anodes. These correlations are confirmed across various lithium‐metal anodes that are cycled with different cobalt‐free cathodes and electrolytes. An advanced electrolyte that is stable to higher voltages is shown to minimize transition‐metal crossover and its effects on lithium‐metal anodes. Overall, these results highlight the importance of maintaining uniform SEI coverage on lithium‐metal anodes, which is disrupted by transition‐metal crossover during operation at high voltages.

Chemistry↗

Associated Particle Imaging of Neutron Inelastic Scatter: 3-D Reconstruction, Capabilities, and Challenges

Associated particle imaging (API) offers unique advantages for 3-D imaging of neutron inelastic scatter, including single-view tomographic imaging and data acquisition when access is limited to only one side of the interrogated object. However, widespread adoption of neutron inelastic scatter imaging has been impeded by several inherent challenges, most prominently spatial resolution, self-attenuation, and statistical noise. Here, in this work, the capabilities and challenges of neutron inelastic scatter imaging are investigated. Instead of focusing on a single imaging application, we identify imaging principles that hold for various neutron inelastic scatter imaging techniques. The primary challenges for 3-D imaging are characterized. The inherent spatial resolution in the time-of-flight (TOF) dimension is derived based on the known system timing resolution and scan geometry. Three reconstruction algorithms are described and demonstrated, including the introduction of modern iterative reconstruction incorporating a physics-based system model. Simulation is leveraged to demonstrate imaging capability with varying coincidence count levels and system timing resolution. An example of measured data with both back-scatter and forward-scatter detector positioning is presented. System design characteristics and their effects on image quality are identified. The imaging framework presented in this article has the potential to facilitate growth of 3-D neutron inelastic scatter API by identifying applications that are a good match for the technique and by targeting system development resources toward the requirements of a specific imaging task.

Associated particle imaging (API)↗

General-Purpose Heat Source Radioisotope Thermoelectric Generator Flight Unit 5 Refurbished (GPHS-RTG F5R) Electrically Heated Thermal Vacuum Testing

Idaho National Laboratory (INL) has been tasked with the evaluation and refurbishment of the General Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) Flight Unit 5 (GPHS-RTG F5R or F5R) that was defueled in 2005. This paper describes the testing of F5R in the thermal vacuum chamber and evaluation of the data demonstrating the generator meets updated Cassini-Huygens requirements. The generator produced 260 We of power at the specified 4100 Wth heat source inventory. This power exceeded the power requirement for 250 We , confirming system integrity and demonstrating that the generator is capable of potential NASA missions.

30 - DIRECT ENERGY CONVERSION↗

GPHS-RTG F5R Electrically Heated Thermal Vacuum Testing

Idaho National Laboratory (INL) has been tasked with the evaluation and refurbishment of the General Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) Flight Unit 5 (GPHS-RTG F5R or F5R) that was defueled in 2005. This paper describes the testing of F5R in the thermal vacuum chamber and evaluation of the data demonstrating the generator meets updated Cassini-Huygens requirements. The generator produced 260 We of power at the specified 4100 Wth heat source inventory. This power exceeded the power requirement for 250 We , confirming system integrity and demonstrating that the generator is capable of potential NASA missions.

30 - DIRECT ENERGY CONVERSION↗

Crossover Effects of Transition‐Metal Ions on Lithium‐Metal Anode in Localized High Concentration Electrolytes

Abstract The stability of the solid–electrolyte interphase (SEI) is critical to the cycle life of lithium‐metal batteries (LMBs). While the crossover effect of transition‐metal ions from cathode to anode is extensively studied in lithium‐ion batteries with graphite anodes, its impact on LMBs remains largely unexplored. Herein, this study investigates the electrochemical and chemical properties of SEI layers formed on lithium‐metal anodes in localized high‐concentration electrolytes (LHCEs) containing dissolved transition‐metal ions (Ni 2+ , Mn 2+ , and Co 2+ ). It is demonstrated that transition‐metal ions in LHCEs reduce the coulombic efficiency (CE) and significantly degrade the cycle life of LMBs. Time‐of‐flight secondary‐ion mass spectrometry (ToF‐SIMS) reveals that SEI structures differ depending on the dissolved TM ion, with Mn 2+ and Co 2+ inducing severe destabilization, and Ni 2+ exhibiting a less severe impact. These findings underscore the detrimental effects of transition‐metal crossover effects in LMB systems.

Guo, Zezhou [Materials Science and Engineering Pro↗

High-Temperature Neutron Diffraction Study of Vanadium and Vanadium–Niobium Null-Matrix Alloy for Spectrum Normalization

This study systematically evaluates a vanadium–niobium (V 94.1 Nb 5.9 ) null-matrix alloy as a reference material for neutron spectrum normalization and compares its performance with that of pure vanadium under identical experimental conditions. Neutron diffraction experiments are conducted on the VULCAN Engineering Materials Diffractometer at the Spallation Neutron Source, Oak Ridge National Laboratory, over a temperature range from room temperature to 1200 °C under vacuum. Pure vanadium exhibited distinct Bragg peaks across all temperatures, with its diffraction behavior influenced by both sample orientation and temperature. As the temperature increased, the diffraction peaks shifted to larger d-spacings and decreased in intensity, while spectral deviation near d ≈ 2.8 Å exceeded 10% at 1200 °C. In contrast, the V–Nb alloy produced a nearly featureless spectrum over the full d-spacing range, confirming near-complete cancellation of coherent scattering over the wide temperature range. Its spectra were insensitive to sample orientation, temperature, and microstructural evolution, with spectral deviation around d ≈ 2.8 Å exceeded 5% at 1200 °C. In conclusion, these results demonstrate that the V–Nb null-matrix alloy provides a thermally stable, efficient, and reliable normalization standard for time-of-flight diffractometers or other instrument where it is needed, enabling reduced data acquisition time and improved data quality in high-temperature neutron diffraction experiments.

Alloys↗

Ion implantation of magnesium guests into type II silicon clathrate films: an alternate approach to doping a cage-like silicon allotrope

Type II silicon clathrates, with their unique cage-like structure, offer exciting potential for applications in thermoelectrics, photovoltaics, and quantum materials due to their tunable electronic and thermal properties. This study investigates the use of ion implantation to introduce targeted guest atoms, which act as dopants, into type II Si clathrate films. The focus is on Mg as a test case for implantation, a dopant previously unreported in type II Si clathrates. The effects of ion implantation on the metastable Si clathrate structure were examined through systematic investigation of implant parameters. Time-of-flight secondary ion mass spectrometry depth profiling confirmed the successful implantation of Mg, while X-ray diffraction and confocal Raman spectroscopy demonstrated minimal structural damage at lower fluences, with the clathrate framework retaining its integrity without converting to other phases. At the higher end of the fluence range implantation caused localized transitions from clathrate to amorphous silicon. Implant activation using rapid thermal annealing was examined with the clathrate structure stable up to 500 °C and being converted to diamond silicon above this temperature. Post-implantation and activation structural characterization showed evidence of damage reversal. Electron paramagnetic resonance studies provided indirect evidence of dopant incorporation. These findings establish a foundation for introducing alternative guests/dopants into the Si clathrate cages through ion implantation, advancing their tunability for next-generation quantum and optoelectronic devices.

36 MATERIALS SCIENCE↗

Inefficacy of mallard flight responses to approaching vehicles

Vehicle collisions with birds are financially costly and dangerous to humans and animals. To reduce collisions, it is necessary to understand how birds respond to approaching vehicles. We used simulated (i.e., animals exposed to video playback) and real vehicle approaches with mallards (Anas platyrynchos) to quantify flight behavior and probability of collision under different vehicle speeds and times of day (day vs. night). Birds exposed to simulated nighttime approaches exhibited reduced probability of attempting escape, but when escape was attempted, fled with more time before collision compared to birds exposed to simulated daytime approaches. The lower probability of flight may indicate that the visual stimulus of vehicle approaches at night (i.e., looming headlights) is perceived as less threatening than when the full vehicle is more visible during the day; alternatively, the mallard visual system might be incompatible with vehicle lighting in dark settings. Mallards approached by a real vehicle exhibited a delayed margin of safety (both flight initiation distance and time before collision decreased with speed); they are the first bird species found to exhibit this response to vehicle approach. Our findings suggest mallards are poorly equipped to adequately respond to fast-moving vehicles and demonstrate the need for continued research into methods promoting effective avian avoidance behaviors.

60 APPLIED LIFE SCIENCES↗

Full Device Evaluation of Metal Halide Perovskite Solar Cells in Low Earth Orbit Aboard the International Space Station

This study investigates how sustained low Earth orbit (LEO) exposure affects metal halide perovskite (MHP) thin films and perovskite solar cells (PSCs). It examines samples deployed on the Materials International Space Station Experiment (MISSE) 15 and 16 missions. Five methylammonium lead iodide (MAPI) thin films are deployed on MISSE-16, each with distinct UV filters to selectively attenuate AM0 spectral bands. While post-flight optical analysis reveals that the least UV-exposed film exhibits the highest emission and lowest non-radiative recombination rate, no clear correlation is observed among the rest, and all MAPI films maintained excellent integrity throughout the mission. MISSE-15 deployed eight PSCs with diverse structures, MHP compositions, and contact materials. Post-flight analysis reveals stable, highly emissive MHPs, but damaged contacts due to ion migration, which caused loss of electrical response. The MISSE missions demonstrate MHPs' suitability for space applications, while highlighting the need for improved interfacial layers and contact materials to enhance charge carrier mobility, prevent ion migration, and improve charge carrier extraction efficiency.

14 SOLAR ENERGY↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

Transient Pulse-Response Time-of-Flight Mass Spectrometry for Complex, Deactivating Heterogeneous Catalytic Systems: Application to Ethane Dehydroaromatization

The study of complex, multistep bond-forming and -breaking reactions in heterogeneous catalytic systems often encounters challenges associated with the involvement of large numbers of intermediates among branching pathways. Kinetic information obtained from traditional steady-state measurements can be complemented with that from time-resolved methods to uncover details of the underlying chemistry. Herein, we describe an approach for tracking the complete time-resolved chemical composition (ca. 4–200 u) of a reactor effluent in response to a reactant pulse. We use a six-port rotary valve with a metered sampling loop to pulse reactants at ambient pressure into a flow reactor packed with a catalyst bed within the isothermal region of a heated furnace. The temporal evolution of effluent species is tracked using time-resolved molecular-beam time-of-flight mass spectrometry. We highlight the possibilities that this method has to offer by studying the complex bifunctional mechanism of ethane dehydroaromatization over an HZSM-5-supported platinum catalyst. We demonstrate that energy-tunable ionization sources, which facilitate isomer resolution, enable the measurement of the full mass spectral time-dependent system response. This includes the evolution of major products and mechanistically relevant reactive intermediates such as 1,3-butadiene and cyclopentadiene; these species have not previously been observed from this reaction. In additional studies, we also assess the role of platinum in the catalyst by examining temporal responses to ethane and ethylene feeds. Results show that two temporally distinct formation pathways exist for methane and benzene, and that their importance depends on both catalyst composition and reactant identity. Additionally, characteristics of catalyst deactivation are uniquely observable in the time-resolved mass spectral response, including the selective deactivation of a benzene formation pathway. The combination of time-of-flight mass spectrometry with tunable ionization enables the simultaneous observation of all effluents in a complex mixture of intermediates with isomer/isobar differentiation capabilities that can be applied to any complex reaction system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Energy Scale Correction Techniques for the X-ray Transition Edge Sensors of the Athena mission

The X-ray Integral Field Unit (X-IFU) onboard the future European X-ray telescope Athena will be the first space instrument carrying an array of more than a thousand transition edge sensors. One of the key challenges of the X-IFU is the measurement of narrow X-ray atomic lines to determine velocity shifts at an unprecedented level of accuracy. For this reason, the energy scale of the instrument needs to be known with extreme accuracy, of 0.4 eV (1σ) up to 7 keV. The energy scale will be measured on the ground through a dedicated calibration campaign using fiducial X-ray sources. Though calibrated, the energy scale is extremely sensitive to the environmental conditions around the TES array, and drifts in the readout chain electronics. Uncorrected, the energy scale can naturally drift up to hundreds of eVs. Changes of the TES gain will be monitored via onboard X-ray calibration sources, and the energy scale will be corrected either per pixel, or within a small groups of pixels. Although simulations show that a 0.4 eV level can be achieved, the very high accuracy required by the X-IFU calls for experimental validation. A dedicated measurement campaign has been performed by NASA Goddard Space Flight Center to characterize the energy scale of a prototype kilo-pixel array of X-IFU-representative TESs. The analysis of the data demonstrated the ability to correct for various drifts using two fiducial lines to track the temporal gain variation. In this paper, we propose to extend this study on the same data set by investigating multi-parameter correction techniques based on both the pulse-height of the fiducial line and the prepulse baseline level, using the knowledge of the TES energy scale at reference temperature/magnetic field set points acquired on the ground. Investigations on the co-adding of pixels to perform a joint correction over pools of pixels is also explored.

79 ASTRONOMY AND ASTROPHYSICS↗

Origin of spin-driven ferroelectricity and effect of external pressure on the complex magnetism of the 6⁢ H perovskite Ba 3 ⁢Ho⁢Ru 2⁢ O 9

The compound Ba 3 HoRu 2 O 9 magnetically orders at 50 K (T N1 ), followed by another complex magnetic ordering at 10.2 K (T N2 ). The second magnetic phase transition was characterized by the coexistence of two competing magnetic ground states associated with two different magnetic wave vectors (K 1 = 0.5 0 0 and K 2 = 0.25 0.25 0). The multiferroicity and magnetoelectric coupling were predicted below T N2 in these 4d-based materials. Here, in this work, we have discussed the origin of spin-driven ferroelectricity, which is not known yet, and the nature of magnetoelectric domains. We have investigated the compound through time-of-flight neutron diffraction, synchrotron x-ray diffraction (XRD), ac susceptibility, frequency-dependent complex dielectric spectroscopy, and dc magnetization under external pressure. We have demonstrated that the noncollinear structure involving two different magnetic ions, Ru (4d) and Ho (4f), breaks the spatial inversion symmetry via inverse Dzyaloshinskii-Moriya (DM) interaction through strong 4d-4f magnetic correlation, which shifts the oxygen atoms and results in nonzero polarization. Such an observation of inverse DM interaction from two different magnetic ions which cause ferroelectricity is rarely observed. The stronger spin-orbit coupling of 4d orbital might play a major role in creating DM interaction of noncollinear spins. We have systematically studied the spin and dipolar dynamics, which exhibit intriguing behavior with shorter coherence lengths of second magnetic phase associated with the k 2 wave vector. The results manifest the development of finite-size magnetoelectric domains instead of true long-range ordering, which justifies the experimentally obtained low value of ferroelectric polarization. The lattice parameters and volume show a sharp anomaly at T N2 obtained by analyzing the temperature-dependence XRD, which is consistent with the ferroelectric transition, predicting a noncentrosymmetric space group, $P\bar{6}2c$, for this compound. Furthermore, we have investigated the effect of external pressure on this complex magnetism. The result reveals an enhancement of ordering temperature by the application of external pressure (~1.6 K/GPa). The external pressure might favor stabilizing the magnetic ground state associated with second magnetic phase. Our study shows an unconventional mechanism of spin-driven ferroelectricity involving inverse DM interaction between Ru (4d) and Ho (4f) magnetic ions due to strong 4d-4f cross coupling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Identifying neutron sources using recoil and time-of-flight spectroscopy

Identification of neutron sources is central to nuclear physics and its applications, from planetary science to nuclear security, yet direct source discrimination from measured neutron spectra remains fundamentally elusive. Here, we introduce a Bayesian protocol that directly infers source ensembles from measured neutron spectra by combining full-spectrum template matching with probabilistic evidence evaluation. Applying this protocol to recoil and time-of-flight spectroscopy, we recover single- and two-source configurations with strong statistical significance (beyond 4⁢𝜎) at event counts as low as ∼10 3 . These results demonstrate that neutron spectral signatures can be leveraged for robust source identification, opening a new observational window for both fundamental research and operationally driven applications.

neutron physics↗