Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Bridging the Flux Gap: Sap Flow Measurements Reveal Species-Specific Patterns of Water Use in a Tallgrass Prairie

Woody encroachment, the process through which woody plants (trees and shrubs) replace grasses and wildflowers in grassland ecosystems, is occurring globally. Because woody plants use water differently (e.g., rates, soil depths of uptake, and time periods of activity) than grasses, woody encroachment could potentially change the water cycle in grasslands. In order to understand how grassland water use might change with ongoing woody encroachment, we measured continuous rates of water loss in common plant species in a North American grassland. Furthermore, we found that the main encroaching shrub in this grassland used more water over time than grasses or wildflowers. Additionally, this shrub and grasses used a large amount of water at night compared to wildflowers. Finally, we found that different weather conditions had different impacts on how water was used by woody plants, grasses, and wildflowers. We suggest that woody encroachment might reduce the amount of water stored in grasslands, which could alter the composition of grassland plants in the future.

54 ENVIRONMENTAL SCIENCES↗

Flow Measurements in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m) is vital to the medical imaging community. It is a radioactive tracer that emits gamma rays as it decays and it is these gamma rays that are then detected through imaging. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. One method of generating Mo-99 is using accelerator based technology, through the irradiation of Mo-100 using an electron beam. This is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and requires extensive cooling of the Mo-100 targets and target housing using pressurized helium gas. Before beam on target, the design of the target stack and target housing is tested at LANL using laser based diagnostics experiments. We quantify the velocity field of the helium gas around the target housing to estimate whether the cooling provided is sufficient for the design and to validate computational fluid dynamics (CFD) models. Fiber optic imaging is also developed for use during cold testing (without beam on target) as well as during irradiation, to obtain real time information on disc performance.

07 ISOTOPE AND RADIATION SOURCES↗

SULI Internship Deliverables (Flow Orifice Design: Measuring Degas Flow of Experiment Loops at the Advanced Test Reactor)

These deliverables present a design for a new orifice flow meter to be installed in three experiment loops at the Advanced Test Reactor. The current configuration of the experiment loop system has an orifice that is not properly sized to the low flow rates of the degas line of the pressurizer system, causing inaccurate flow measurements. Under consideration of flow conditions and system constraints, an iterative procedure was utilized to determine the optimal sizing for a new orifice. This orifice is designed to accurately and precisely measure the flow rate of the degas line, which will consequently improve control of the pressure and chemistry of the loop pressurizer system. The scope of this project includes recommendations for orifice sizing, material, flange type, face type, and installation location on the loop piping spools. The design is suitable for experiment loops 1D-N, 2B-SE, and 2D-SW and meets all necessary standards.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development and experimental evaluation of an acoustic flow meter prototype for measuring air flow

Here, this study outlines the development and testing of a flow meter prototype specifically designed for use in nuclear reactor environments. The meter uses flow-induced vibration to measure flow rates and is designed for remote monitoring in harsh environments where radiation can damage electronics. The device generates a vibration signal produced by a feedback system when fluid flows out of an orifice and interacts with a downstream wedge. The frequency of the vibration signal corresponds directly to flow rate and velocity. The study investigates geometric parameters intrinsic to the prototype, such as orifice height, width, edge distance, and chamber length. Different configurations were also tested, including a bypass loop with variable cross-sections around the device. The investigation results reveal the impact of these geometric parameters on the vibration signal output, providing valuable insights for future design improvements and enhancing the effectiveness of flow metering systems used in nuclear reactor applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying Uncertainties in Heat Capacity Measurements of Molten Salts Determined Using Differential Scanning Calorimetry

Uncertainty in specific heat capacity values of a molten salt determined by using differential scanning calorimetry (DSC) was assessed based on the precision of replicate measurements of heat flows used in the calculation and effects of corrections that are commonly made to heat flow measurements. The ratio method of determining heat capacity was applied using the results of replicate heat flow measurements made with two empty cells, a sapphire reference material, and three samples of a doped NaCl-UCl 3 salt mixture. Replicate measurements with empty cells were used to quantify the effects of system instabilities and sensitivities on the measured heat flows of sapphire and salt. The combined effects of uncertainties in individual heat flow measurements made with blank cells using this system were quantified to be 2.6 μV based on isothermal holds before and after the scan, with cell placement adding the greatest uncertainty. This value was used as the tolerance for accepting background-corrected heat flows measured with sapphire and salt to calculate the specific heat capacity. The acceptable heat flows measured for sapphire and salt over the temperature range of 540 to 725 °C resulted in calculated specific heat capacity values ranging from 0.53 to 0.91 J g −1 K −1 with an overall average value of 0.70 J g −1 K −1 and an uncertainty of 0.22 J g −1 K −1 at the 99 % confidence level. The combined uncertainty in the specific heat capacity masked detection of any effect of temperature or salt composition that occurred.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Method and system to measure gas flow

A system for measuring gas flow generally including a passive acoustic wave generator disposed in a gas flow stream to passively generate an audio signal through vortex shedding, a sound capturing instrument disposed outside the gas stream to produce an electrical signal representative of the acoustic signal, a temperature sensor to obtain temperature measurements indicative of the temperature of the gas flow stream and a control system for determining the gas flow, such as velocity or flow rate, as a function of the acquired acoustic and temperature measurements. The acoustic wave generator includes a corrugated flow channel whose geometric design is so tuned to generate an acoustic emission whose frequency signature varies as a function of the gas flow velocity. The control system may acquires time-domain acoustic data, and process that data to obtain a frequency-domain representation from which gas velocity or gas flow rate can be determined.

Cetiner, Mustafa S.↗

A software‐defined networks ‐based measurement method of network traffic for 6G technologies

Abstract In software‐defined networks (SDN) for 6G technologies, the controller should accurately and efficiently measure the flow traffic in switches for traffic engineering. Fine‐grained flow measurement can more accurately describe the traffic in the network, but it also consumes much more resources. To reduce the overhead incurred in the measurement process and obtain the approximate fine‐grained measurements, we propose a novel lightweight measurement scheme that runs in the controller. The novel lightweight measurement architecture consists of two parts: coarse‐grained measurement and interpolation‐optimization. In the first part, based on the SDN architecture, we use the pull‐based random sampling method to quickly obtain the coarse‐grained measurement of flow traffic through OpenFlow protocol. In the second part, we insert some discrete values into the coarse‐grained measurement with the interpolation theory, then we optimize interpolation results until finding the optimal fine‐grained flow traffic measurement by utilizing the multiconstraint method. We verified the feasibility of the proposed measurement method, and simulation results show that the measurement error of the proposed method is under 25%, but the flow measurement overhead of this method occupies only 3.3% compared with that of the fine‐grained method.

Huo, Liuwei↗

Eddy Current Flow Meter Measurements and Modeling Validation

The goal of the eddy current flow meter (ECFM) is to monitor velocities and temperatures of conductive liquid metals. The ECFM can also detect voids in two-phase liquid metal flows. Measurement of these flows can greatly improve the accuracy of the empirical formulas used for fluid dynamics near the reactor core and aid in mapping any non-uniformities in fluid flow such as estimates of temperature and phase. While the eventual goal is to develop the ECFM for the liquid sodium surrounding the Versatile Test Reactor (VTR) core, this report focuses on modeling and experimental validation of ECFM for a moving solid test rod and for liquid mercury in the Target Test Facility (TTF) flow loop to better understand and further develop ECFM measurement capabilities by validating model predictions with benchmark experiments. Eventually the models could be used to design and optimize future ECFMs for specific applications such as monitoring flow within the VTR pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

In-situ thermophysical measurement of flowing molten chloride salt using modulated photothermal radiometry

Molten salts are leading candidates for high-temperature heat transfer fluids (HTFs) for thermal energy storage and conversion systems in concentrated solar power (CSP) and nuclear energy power plants. The ability to probe molten salt thermal transport properties in both stationary and flowing status is important for the evaluation of their heat transfer performance under realistic operational conditions, including the temperature range and potential degradation due to corrosion and contamination. However, accurate thermal transport properties are usually challenging to obtain even for stagnant molten salts due to different sources of errors from convection, radiation, and corrosion, let alone at flowing status. To the best of authors’ knowledge, there is no available in-situ technique for measuring flowing molten salt thermal conductivity. Here, we report the first in-situ flowing molten salt thermal conductivity measurement using modulated photothermal radiometry (MPR). We could successfully perform the first in-situ thermal conductivity measurement of flowing molten NaCl-KCl-MgCl 2 in the typical operating temperature (520 and 580 °C) with flow velocities ranging from around 0.3 to 1.0 m s -1 . The relative change of the molten salt thermal conductivity was measured. Gnielinski’s correlation was also used to estimate the heat transfer coefficient h of the flowing NaCl-KCl-MgCl 2 in the given experimental condition. Furthermore, the work showed the potential of the MPR technique serving as an in-situ diagnostics tool to evaluate the heat transfer performance of flowing molten salts and other high-temperature HTFs.

14 SOLAR ENERGY↗

In-situ thermal transport measurement of flowing fluid using modulated photothermal radiometry

In situ thermal transport measurement of flowing fluid could be useful for the characterization and diagnosis of practical thermal systems such as fluid heat exchangers and thermal energy storage systems. Despite abundant reports on the ex-situ thermal conductivity measurement of stagnant fluids, a suitable technique for the thermal conductivity measurement of flowing fluid has been rarely reported. Here, this paper presents the thermal conductivity measurement of flowing fluid within a pipe using a non-contact modulated photothermal radiometry (MPR) technique, where the surface of the pipe is heated by an intensity-modulated laser and the heat diffuses into the fluid with suitable modulation frequency. We design a tube section with small wall thickness suitable for the MPR measurements to maximize the sensitivity of the thermal response to the fluid properties while minimizing the lateral heat spreading effect. Intrinsic thermal conductivity of different fluids was obtained within a proper range of frequency and flow velocity where the forced convection effect is negligible. The forced convection effect became prominent at high flowing velocity and at low modulation frequency, leading to higher effective thermal conductivity of the fluid. It is found that the intrinsic thermal conductivity could be obtained when the flow velocity is less than 100 mm/sec and Re D 1/2 Pr 1/3 < 100 for DI water and Xceltherm oil under the specified experimental conditions, where Re D is the Reynolds number and Pr is the Prandtl number.

42 ENGINEERING↗

Evaluation of Hopper Flow Prediction based on Cubical Triaxial Tester Data and FEM

A cubical triaxial tester (CTT) laboratory device was used to collect key bulk flow characteristics of Crumbles® 6mm rotary sheared woody biomass and Crumbles® 2mm rotary sheard corn stover. The flow properties and a CAD model of a hopper and conveyor system to predict the consistency of flow of material from the hopper. Prediction included the likeliness of jamming, bridging, or ratholing. Each material was then loaded into the hopper and the actual bulk flow was measured. Measured flow closely matched the predicted flow.

09 BIOMASS FUELS↗

Perturbed Ion Temperature and Toroidal Flow Profile Measurements in Rotating Neoclassical Tearing Mode Magnetic Islands

The perturbed ion temperature and toroidal flow were measured in rotating Neoclassical Tearing Modes (NTM) in a tokamak for the first time. These toroidally and radially resolved profiles were obtained by impurity ion spectroscopy in a 2,1 NTM in DIII-D. In agreement with drift-kinetic simulations, the electron temperature profile is flat, while the ion temperature gradient is restored across the magnetic island O-point in the presence of fast ions; the perturbed flow has minima in the O-points and maxima at the X-points. Furthermore, these measurements provide the first confirmation of the theoretically expected ion temperature and flow response to a magnetic island needed to predict the NTM on set threshold scaling for ITER and other future tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of flow properties coupled to experimental and numerical analyses of dense, granular flows for solar thermal energy storage

Granular flows of sintered bauxite proppants were researched along an inclined plane for solar thermal energy storage applications. Granular flow properties needed to drive numeric granular models were measured for improved numerical model predictions for Carbobead CP 50/140, 40/100, and 30/60 particles. Particle shape and size distributions were determined by coupling optical microscopy to an in-house image processing algorithm. The impulse excitation technique was used to measure elastic and shear moduli, and compute Poisson’s ratio. The coefficient of static sliding friction was measured using the slip-stick method, and the static rolling friction was determined from measured shear on particles positioned between two hot-pressed plates. The coefficient of restitution was measured by dropping particles on a surface and determining the kinetic energy before and after impact with the surface using high resolution particle tracking velocimetry. Particle size did not significantly impact the coefficients of restitution and static rolling friction, however, particle shape distribution resulted in a large variation in measurements. An inclined flow experiment was performed to characterize granular flows of Carbobead CP 30/60 particles using particle image velocimetry. Numerical models of the experiment using discrete element method were generated with the measured mechanical properties as inputs for comparison with experimental results. A constant directional torque rolling friction model best predicted bulk granular flow behavior. Furthermore, good agreement between the model and experiment was achieved at ambient, steady state conditions, with average velocity differences <10%.

14 SOLAR ENERGY↗

Measuring differential flow angle fluctuations in relativistic nuclear collisions

Recently studies of the differential nature of the flow angle fluctuations, known as event plane angular decorrelation, indicated that measurements that assume a common symmetry plane may need to consider the flow angle fluctuations effect. Using the HIJING and AMPT models, it is shown that the flow angle fluctuations measurements, obtained with the two- and three-subevents correlation method, could have significant nonflow effects associated with long- and short-range nonflow correlations. The current study demonstrates the four-subevents cumulant methods' ability to reduce the nonflow effects. Finally, it is further argued that the measurements using the four-subevents correlation method can be used to provide accurate quantification of the differential flow angle fluctuations.