Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluid Shifts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Microwave Resonant Cavity Transducer Recalibration Procedures

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Inner diameter of the cylindrical cavity is 22.2 mm, and the thin wall is approximately 200µm thick. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Sodium flow rate sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed. From the measurements, we observed significant scatter in high temperature liquid sodium at low flow velocity values. Our hypothesis is that this is caused by temperature drift in the liquid, which results in thermal expansion of the cavity and a drift in the resonator frequency. In this report, we investigate temperature dependence of the resonant frequency through development of analytic models and preliminary analysis of experimental data. In addition, we develop a procedure for compensation for temperature drift during flow sensing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Third Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Probabilistic Analysis of Long-Term Degradation of Microwave Cavity Flow Sensor

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. We have performed a proof-of-concept experiment of flow sensing with the transducer in liquid sodium at 340°C in impinging liquid jet geometry. The transducer remained in liquid sodium for 70 days. After removal, no structural damage was observed, and the expected transducer response was verified in a water test. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance. Since a yellowish residue was observed on the transducer surface after 70 days of immersion in liquid sodium, we have investigated possible evidence of corrosion. Chromium depletion is a typical indicator of the corrosion process in stainless steel. Scraping off a residue from the transducer and performing scanning electron microscopy (SEM) with energy dispersive analysis (EDS) did not find any chromium in the residue. Approximately 60% of the residue consisted of copper, which can be attributed to contamination of sodium due to powder residue from machining of copper and brass components of the transducer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Probing Pore Size and Connectivity in Porous Silicas Using 13C MAS NMR Spectroscopy of Supercritical Methane

Measuring the pore size and pore-size distributions and exploring the fluid-exchange dynamics between different types of pores in porous materials remains a significant experimental challenge but is critical to understanding catalysis, chromatography, nutrient cycling, and a whole range of geochemical phenomena, including shale gas and tight gas extraction. Here, we present the results of 1D 13 C NMR and 2D exchange spectroscopy (EXSY) NMR investigations of a porous silica using supercritical methane (scCH 4 ) as a direct probe of pore size and fluid exchange between pore types. The results show that the 13 C chemical shift of scCH 4 adsorbed in nanometer-scale silica pores becomes more negative with increasing pore diameter, in agreement with trends reported for gas hydrates, zeolites, MOFs, and clays and other microporous (<10 nm pores) geochemical materials. These 13 C chemical shifts follow a natural log–linear trend with pore size in the vacuum-dried porous silicas studied here, allowing one to predict pore size based on the 13 C chemical shift in dry silica nanopores. The EXSY and 1D 13 C NMR results both show that CH 4 exchanges between pore and bulk fluid environments over rate scales from 0.01 to 1 kHz in vacuum-dried samples and that exchange dynamics must be considered when interpreting 13 C NMR of pore-adsorbed CH 4 . Introducing H 2 O to the system causes the 13 C chemical shift to become more negative with increasing H 2 O content as a result of H 2 O preferentially filling small pores, forcing CH 4 to occupy larger pores that are better connected to the bulk environment. Likewise, the 1D 13 C data show a decreased distribution of exchange rates between pore-adsorbed and bulk CH 4 in the presence of H 2 O.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Well proppants

Deployable smart acoustic resonance particles have dense cores, compliant matrixes surrounding the cores and stiff outer shells surrounding the matrixes. The particles have mechanical stress sensitivities that provide unique band gap shifts when compressed. Groups of similar particles with similar stress sensitivities and similar band gap shifts are added at different times to hydraulic fluids, as circulated through wells with the fluid and pushed into fractures. A plural, sonic monopole well logging tool is lowered into the well to determine locations and depth of fractures and local pressures by distinct resonance of individual groups.

Pollock, Jacob↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial full core SMR simulations with NekRS

This document describes the completion of a recent milestone of the ExaSMR program concerning "Full core simulations". The ExaSMR project is developing tools for coupling Monte Carlo (MC) radiation transport solvers to a computational fluid dynamics (CFD) solver. Work is based on the Shift MC, OpenMC MC, and Nek5000/NekRS CFD codes. As part of this milestone, a novel set of pin-resolved CFD full-core simulations have been performed for the first time. These simulations represent a significant increase in capability in what is now possible with CFD on pre-Exascale systems. The simulations have been performed with the spectral element solvers NekRS on the supercomputer Summit. Multiple simulations campaigns have been conducted: (1) LES simulations in bare bundle, (2) RANS simulations in bare bundles, (3) RANS simulations with momentum sources and (4) Conjugate heat transfer calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A weighted shifted boundary method for immersed moving boundary simulations of Stokes' flow

The Shifted Boundary Method (SBM) belongs to the class of unfitted (or immersed, or embedded) finite element methods, and relies on reformulating the original boundary value problem over a surrogate (approximate) computational domain. The surrogate domain is constructed so as to avoid cut cells and the associated problematic implementation and numerical integration issues. Accuracy is maintained by modifying the original boundary conditions using Taylor expansions: hence the name of the method, that shifts the location and values of the boundary conditions. Here, in this article, we extend the SBM to the simulation of incompressible Stokes flow, by appropriately weighting its variational form with the elemental volume fraction of active fluid. This approach allows to drastically reduce spurious pressure oscillations in time, which are produced if the total volume of active fluid were to change abruptly over a time step. The proposed Weighted SBM (W-SBM) exactly preserves states of hydrostatic equilibrium, and induces small mass and momentum conservation errors, which converge as the grid is refined. This is in analogy to cutFEMs and related unfitted approaches, which rely on an affine representation of cut boundaries. We demonstrate the robustness and accuracy of the proposed method with an extensive suite of two-dimensional tests.

97 MATHEMATICS AND COMPUTING↗

Direct measurements of the 3D plasma velocity in single-helical-axis RFP plasmas

The first local velocity measurements of helical equilibrium plasmas in the Reversed Field Pinch (RFP) Single Helical Axis (SHAx) state using a Charge Exchange Recombination Spectroscopy (CHERS) diagnostic are presented. Measurements show strong axisymmetric and non-axisymmetric flow, with n ¼ 5 components of flow related to the ðm; nÞ¼ð1; 5Þ dominant magnetic mode on the order of the axisymmetric flow in certain regions of the plasma, as well as significant n > 5 flow. Flow measurements are compared with NIMROD simulations of visco-resistive, single-fluid MHD in toroidal and cylindrical geometries with limited axial periodicity. Both measurements and the simulation with toroidal geometry show stronger inboard flows relative to the outboard flows, which is attributed to the toroidal geometry of the device. In the experiment, the n ¼ 5 component of flow is phase shifted from the reconnection-like flow pattern observed in the single-fluid simulations, possibly due to decoupling of the ion and electron fluids over much of the plasma. Finally, the strength of the helical angular flow shear relative to the critical shear necessary to disrupt nonlinear coupling between tearing modes is calculated around the helical magnetic axis. The shear in the measured flow is on the order of the theoretical critical threshold needed to nonlinearly decouple modes, but the measurement uncertainty in the gradient of the flow is large.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced Manganese Oxidation at the Biofilm–Fluid Interface Drives Pore-Scale Patterns in Mineral Precipitation

Microbial oxidation of manganese (Mn) from aqueous Mn(II) to solid-phase Mn(III, IV) minerals catalyzes Mn(II) removal in natural and engineered porous systems. However, little is known about the spatiotemporal evolution of Mn biomineralization in confined spaces that experience simultaneous Mn(II) delivery and Mn oxide precipitation. Here, we combine time-lapse microscopy, image analysis, and mass spectrometry to quantify the extent and rate of Mn biomineralization by Pseudomonas putida GB-1 in an optically transparent two-dimensional porous medium. We found that Mn(II) oxidation initially occurred within biofilms but shifted over time toward the edges of biofilms in contact with pore fluid. Minerals precipitated outside of the initial biofilm footprint likely due to surface-mediated oxidation of Mn(II) by nascent biogenic Mn oxides, reinforcing a gradient in mineral accumulation from the Mn(II) source near the reactor inlet to the outlet. The rate of mineral precipitation outside the biofilm footprint surpassed the rate of mineral accumulation inside biofilms within 6 h and accounted for two-thirds of the total Mn oxide mass in the pore space at the end of the experiment. This work advances a mechanistic understanding of coupled biotic and abiotic Mn oxidation in porous environments while providing a novel platform to quantify microbe-mineral-fluid interactions.

Biofilms↗

Probing ethane phase changes in bead pack via high-field NMR spectroscopy

Phase equilibria analysis in two-phase systems requires discernment of the individual phases as well as the interfacial region. The phase behavior of fluids in constraint geometries have been studied through several techniques. High-Field Nuclear Magnetic Resonance (HF-NMR) can be used to detect fluid phases, i.e. gas, liquid, or supercritical fluid, in the bulk or under confinement. In solution-state HF-NMR, each phase exhibits a distinct chemical shift that correlates to the phase density. In turn, the emergence of multimodal in NMR spectra reveals the coexistence of multiple phases in fluid systems. Our results for ethane show that HF-NMR can enable tracking phase changes in the bulk, but also in macro-scale (10–100's μm in pore size) porous systems at various pressure and temperature conditions, even when the system us out of equilibrium. Finally, these results creates potential opportunities to investigate phase changes influenced by confinement in porous systems, though additional steps are necessary.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A conservative phase-space moving-grid strategy for a 1D-2V Vlasov–Fokker–Planck Solver

In this work, we develop a conservative configuration- and velocity-space (i.e., phase-space) moving-grid strategy for the Vlasov–Fokker–Planck (VFP) equation in a planar geometry. The velocity-space grid is normalized and shifted in terms of the thermal speed and the bulk-fluid velocity, respectively. The configuration-space grid is moved according to a mesh-motion-partial-differential equation (MMPDE), which equidistributes a monitor function that is inversely proportional to the gradient-length scales of the macroscopic plasma quantities. The resulting inertial terms in the transformed VFP equations are discretized to ensure the discrete conservation of mass, momentum, and energy. To satisfy the discrete conservation theorems in the presence of phase-space mesh motion, we employ the method of discrete nonlinear constraints – explored in previous studies – but the underlying symmetries are determined in a much more efficient manner than before. The conservative grid-adaptivity strategy provides an efficient scheme that resolves important physical structures in the phase-space while controlling the computational complexity at all times. We demonstrate the favorable features of the proposed algorithm through a set of test cases of increasing complexity. The problems test independent components of the algorithms, as well as the integrated capability on settings relevant to inertial confinement fusion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanoscale viscosity of confined polyethylene oxide

Complex fluids near interfaces or confined within nanoscale volumes can exhibit substantial shifts in physical properties compared to bulk, including glass transition temperature, phase separation, and crystallization. Because studies of these effects typically use thin film samples with one dimension of confinement, it is generally unclear how more extreme spatial confinement may influence these properties. In this work, we used x-ray photon correlation spectroscopy and gold nanoprobes to characterize polyethylene oxide confined by nanostructured gratings (<100nm width) and measured the viscosity in this nanoconfinement regime to be ~500 times the bulk viscosity. Here, this enhanced viscosity occurs even when the scale of confinement is several times the polymer's radius of gyration, consistent with previous reports of polymer viscosity near flat interfaces.

36 MATERIALS SCIENCE↗

Pressure shifted valve timing

A hydraulic pump-motor includes a cylinder block including a plurality of fluid chambers, a piston in each of the fluid chambers, a cam, a fixed valve area profile, and a timing adjustment actuator. The cam includes a cam surface that engages the pistons and drives movement of the pistons relative to the fluid chambers in response to relative rotation between the cam and the fluid chambers. The fixed valve area profile is configured to control fluid flows between the fluid chambers and first and second ports. The timing adjustment actuator is configured to adjust an angular orientation of the fixed valve area profile relative to an angular orientation of the cam based on a pressure differential between a pressure at the first port and a pressure at the second port.

Boyce-Erickson, Grey C.↗

Subsurface microbial community structure shifts along the geological features of the Central American Volcanic Arc

Subduction of the Cocos and Nazca oceanic plates beneath the Caribbean plate drives the upward movement of deep fluids enriched in carbon, nitrogen, sulfur, and iron along the Central American Volcanic Arc (CAVA). These compounds fuel diverse subsurface microbial communities that in turn alter the distribution, redox state, and isotopic composition of these compounds. Microbial community structure and functions vary according to deep fluid delivery across the arc, but less is known about how microbial communities differ along the axis of a convergent margin as geological features (e.g., extent of volcanism and subduction geometry) shift. Here, we investigate changes in bacterial 16S rRNA gene amplicons and geochemical analysis of deeply-sourced seeps along the southern CAVA, where subduction of the Cocos Ridge alters the geological setting. We find shifts in community composition along the convergent margin, with communities in similar geological settings clustering together independently of the proximity of sample sites. Microbial community composition correlates with geological variables such as host rock type, maturity of hydrothermal fluid and slab depth along different segments of the CAVA. This reveals tight coupling between deep Earth processes and subsurface microbial activity, controlling community distribution, structure and composition along a convergent margin.

Science & Technology - Other Topics↗

Effects beyond ideal MHD on stability of wide and enhanced pedestal regimes in NSTX

Stability of edge-localized modes (ELMs) in spherical tokamaks is explored using the extended MHD model. Linear NIMROD simulations have been performed for three NSTX discharges 132543, 132588, and 141133, to investigate the role of resistivity, diffusivity, and shear flows on the onset of ELMs. The first discharge represents the wide pedestal regime and the later two discharges represent ELM-free enhanced pedestal H-mode. We first present the effect of toroidal rotation shear and find a flow shear destabilizing effect in these NSTX discharges. Simulations are also extended to include the two-fluid and ion gyroviscosity effects. Simulations show that the flow shear can shift the mode spectrum and alter the critical condition of ELM onset. We also uncover that ELM onset prediction in spherical tokamaks requires effects beyond MHD, in particular gyroviscosity and diamagnetic terms could stabilize Peeling-Ballooning modes consistent with the experimental observation of ELM-free regimes in NSTX. The findings give new insight into the nature of the interplay between resistivity, flows, and diamagnetic stabilization in ELM suppression and have potential applications to ELM control schemes in NSTX-U and next-generation spherical tokamaks. This study identifies the essential physical effects that must be included in future predictive and validation simulations.

NSTX↗