Search NASA⌕ Search

SEARCH · Search NASA

Results for “Forced convection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Motorette Thermal Performance Testing and Modeling for an Electric Motor with Additively Manufactured Hollow Conductors with Integrated Heat Pipes

This paper discusses the design, build and test of a motorette to characterize the thermal performance of an additively manufactured coil integrated with heat pipes. The motorette is powered using a variable frequency AC power supply and cooled through two independent cooling systems. The first cooling system cools the stator core using forced convection of air flowing over a finned heat sink mounted on the stator outer diameter. The second cooling system cools the heat pipes using forced convection of 50-50 water ethylene glycol (WEG) mixture flowing through condenser chambers. A 3D thermal FEA model of the setup is built and heat transfer coefficients (HTC) of convective boundaries are computed using coolant flow rates from test data and empirical equations. Temperature at locations on the coil and heat sink are recorded and compared to thermal model predicted values. A maximum temperature error of 22.7% occurs at 180ARMS and 800 Hz operating point for the AM dual coil. The thermal model provides higher temperatures compared to test results and hence it is on the conservative side but in general, there is good correlation between test and model results. Lastly, opportunities for improvement to both test data measurement and 3D thermal FEA modeling are discussed.

additive manufacturing↗

Pronghorn: A Multidimensional Coarse Mesh Application for Advanced Reactor Thermal-Hydraulics

This paper presents an overview of Pronghorn, a multiscale thermal-hydraulic (T/H) application developed by Idaho National Laboratory and the University of California, Berkeley. Pronghorn, built on the open-source finite element Multiphysics Object-Oriented Simulation Environment (MOOSE), leverages state-of-the-art physical models, numerical methods, and nonlinear solvers to deliver fast-running advanced reactor T/H simulation capabilities within a modern software engineering environment. This work summarizes the physical models, multiphysics and multiscale coupling, and numerical discretization in Pronghorn with emphasis on our initial target application to pebble bed reactors (PBRs). A diverse set of applications are shown to depressurized natural circulation in the SANA experiments, forced convection in the Pebble Bed Modular Reactor, three-dimensional (3-D)/one-dimensional coupling of Pronghorn and RELAP-7 systems T/H for loop analysis in the High Temperature Reactor Power Module, and forced convection in the Mark-1 Pebble Bed Fluoride-Salt-Cooled High-Temperature Reactor. A multiphysics coupling of Pronghorn, RELAP-7, and Griffin deterministic neutronics for a gas-cooled PBR demonstrates the capability of the MOOSE framework for reactor design calculations. These applications highlight the verification and validation underlying Pronghorn’s software development while emphasizing features that improve upon capabilities offered by legacy tools in areas such as 3-D unstructured meshing, physics modeling, and multiphysics coupling.

97 MATHEMATICS AND COMPUTING↗

Subseasonal Variability of U.S. Coastal Sea Level from MJO and ENSO Teleconnection Interference

Abstract Climate variability affects sea levels as certain climate modes can accelerate or decelerate the rising sea level trend, but subseasonal variability of coastal sea levels is underexplored. This study is the first to investigate how remote tropical forcing from the MJO and ENSO impact subseasonal U.S. coastal sea level variability. Here, composite analyses using tide gauge data from six coastal regions along the U.S. East and West Coasts reveal influences on sea level anomalies from both the MJO and ENSO. Tropical MJO deep convection forces a signal that results in U.S. coastal sea level anomalies that vary based on MJO phase. Further, ENSO is shown to modulate both the MJO sea level response and background state of the teleconnections. The sea level anomalies can be significantly enhanced or weakened by the MJO-associated anomaly along the East Coast due to constructive or destructive interference with the ENSO-associated anomaly, respectively. The West Coast anomaly is found to be dominated by ENSO. We examine physical mechanisms by which MJO and ENSO teleconnections impact coastal sea levels and find consistent relationships between low-level winds and sea level pressure that are spatially varying drivers of the variability. Two case studies reveal how MJO and ENSO teleconnection interference played a role in notable coastal flooding events. Much of the focus on sea level rise concerns the long-term trend associated with anthropogenic warming, but on shorter time scales, we find subseasonal climate variability has the potential to exacerbate the regional coastal flooding impacts. Significance Statement Coastal flooding due to sea level rise is increasingly threatening communities, but natural fluctuations of coastal sea levels can exacerbate the human-caused sea level rise trend. This study assesses the role of tropical influences on coastal subseasonal (2 weeks–3 months) sea level heights. Further, we explore the mechanisms responsible, particularly for constructive interference of signals contributing to coastal flooding events. Subseasonal signals amplify or suppress the lower-frequency signals, resulting in higher or lower sea level heights than those expected from known climate modes (e.g., ENSO). Low-level onshore winds and reduced sea level pressure connected to the tropical phenomena are shown to be indicators of increased U.S. coastal sea levels, and vice versa. Two case studies reveal how MJO and ENSO teleconnection interference played a role in notable coastal flooding events. Much of the focus on sea level rise concerns the long-term trend associated with anthropogenic warming, but on shorter time scales, we find subseasonal climate variability has the potential to exacerbate the regional coastal flooding impacts.

Meteorology & Atmospheric Sciences↗

Sodium Chemistry Assessment and Initiation of Sodium Exposure Experiment on A709 Commercial Heats and LPBF 316H SS

This report documents sodium chemistry characterization and the initiation of forced‑convection sodium exposure experiments for two structural materials for sodium‑cooled fast reactors (SFRs): Alloy 709 (solution‑annealed and with an additional 775 °C/10 h precipitation treatment) and laser powder bed fusion (LPBF) 316H stainless steel tensile specimens printed with an as‑built surface condition. The sodium exposure experiment was conducted in a forced‑convection sodium loop with two vessels operated at 550 °C and 600 °C, and a cold trap maintained at <130 °C. Carbon activity in sodium was quantified using a nickel‑foil equilibration method. Initial post‑exposure evaluation after ~1,000 h indicates negligible thickness change for Alloy 709 and a small but measurable mass decrease. To isolate thermal effects from sodium effects, parallel thermal‑aging experiments were performed on Alloy 709 at 550 °C and 600 °C. Baseline tensile tests at room temperature, 550 °C, and 600 °C show expected reduction in strength with increasing temperature and serration tensile curves at elevated temperatures, consistent with dynamic strain aging. After 3,000 h thermal aging, Alloy 709 exhibits modest strengthening and reduced ductility at 550 °C. Together, these results establish the loop chemistry conditions and provide the initial corrosion and mechanical property results for ongoing long‑duration sodium exposure of Alloy 709 and LPBF 316H stainless steel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

General Correlations for Laminar Flow Friction Loss and Heat Transfer in Plain Rectangular Plate-Fin Cores

In this paper, new generalized correlations for predicting the average fanning friction factor f and average Nusselt number Nu for laminar flow in plain plate-fin compact cores of rectangular cross section are presented. These are based on extended experimental data, as well as three-dimensional computational simulations, obtained for a broad range of fin density and geometrical attributes. The results indicate that while the fully developed forced convection scales only with the interfin channel cross-sectional ratio α (fin spacing by fin height), the entrance region hydrodynamic and thermal performance is additionally a function of the fin-core length L, flow Reynolds number Re, and fluid Prandtl number Pr. The developing flow and convection is further shown to scale as: (fRe)~(L/d h Re) 1/2 , and Nu ~(L/d h Re) 1/2 Pr 1/3 Φ(α), where f, Re, and Nu are all based on the hydraulic diameter dh of the interfin flow channel. Generalized correlations for both (fRe) and Nu are developed by the corresponding scaling of the forced convection behavior and asymptotic matching of the entrance or developing flow (short fin-core flow length) and the fully developed flow (large fin-core flow length) region performance. Finally, the predictions from these correlations are found to be within ±15% of all available experimental data for air, water, and glycol (0.71 ≤ Pr ≤ 10), and fin cores with 0 < α ≤ 1.

36 MATERIALS SCIENCE↗

Efficient facemask decontamination via forced ozone convection

The COVID-19 crisis has taken a significant toll on human life and the global economy since its start in early 2020. Healthcare professionals have been particularly vulnerable because of the unprecedented shortage of Facepiece Respirators (FPRs), which act as fundamental tools to protect the medical staff treating the coronavirus patients. In addition, many FPRs are designed to be disposable single-use devices, creating an issue related to the generation of large quantities of non-biodegradable waste. In this contribution, we describe a plasma-based decontamination technique designed to circumvent the shortages of FPRs and alleviate the environmental problems posed by waste generation. The system utilizes a Dielectric Barrier Discharge (DBD) to generate ozone and feed it through the fibers of the FPRs. The flow-through configuration is different than canonical ozone-based sterilization methods, in which the equipment is placed in a sealed ozone-containing enclosure without any flow through the mask polymer fibers. We demonstrate the rapid decontamination of surgical masks using Escherichia coli ( E. coli ) and Vesicular Stomatitis Virus (VSV) as model pathogens, with the flow-through configuration providing a drastic reduction in sterilization time compared to the canonical approach. We also demonstrate that there is no deterioration in mask structure or filtration efficiency resulting from sterilization. Finally, we show that this decontamination approach can be implemented using readily available tools, such as a plastic box, a glass tube, few 3D printed components, and the high-voltage power supply from a plasma globe toy. The prototype assembled for this study is portable and affordable, with effectiveness comparable to that of larger and more expensive equipment.

36 MATERIALS SCIENCE↗

Radiative Heat Transport and Optical Characterization of High Temperature Molten Salts

The goal of this project was to advance the field of molten fluoride radiative heat transfer (RHT), through optical property measurements, heat transfer loop construction and operation, and computational fluid dynamics simulations. The following outcomes have been accomplished. A comprehensive review has been conducted to compile all available RHT-relevant optical absorption data for molten fluorides. The various measurement methods have also been compiled and critiqued. Thermal emission measurement methods have been refined and documented. A unique thermal emissivity measurement facility has been constructed and used to measure the emissivity of flowing FLiBe-exposed SS316 samples. A slight increase has been observed in the emissivity compared to unexposed SS316. A dual reflectance-emission setup was partially demonstrated for the purpose of molten fluoride absorption measurement. Preliminary infrared edge data for FLiNaK was obtained. A visible near-infrared (NIR) measurement setup has been constructed and will be used to measure absorption of corrosion products in FLiBe. A new multi-band thermal radiation method using blackbody-weighted spectral bands for the absorption-coefficient was deployed to investigate the thermal performance of the UW Natural Circulation FLiBe Loop under various power levels and operating conditions. The results showed an increasing and decreasing trend in the overall heat transfer with optical thickness with a maximum at optical thickness τ D ≈Ο(1). A forced convection FLiBe loop was constructed for the purpose of studying corrosion and thermal hydraulic phenomena. A vertical cantilever pump is used to achieve up to 5 gpm and 5 m/s flow velocity in hot and cold test sections. A methodology has been established for modeling radiative heat transfer (RHT) in molten salt coolants for the purpose of quantifying the contribution of thermal radiation in conditions relevant to FHR or MSR systems. The comparison between the results obtained for forced and mixed convection showed that in the studied ranges of optical thickness, the maximum effect of RHT on overall heat transfer was 60% improvement observed at z/D = 250 for forced convection; whereas for mixed convection, that value was higher at 170% observed at z/D = 30. The highest effect of RHT on the overall energy distribution was observed at τ D ≈3.4. Negligible effect (<20%) was observed above τ D =18 and below τ D ≈0.002. A CFD code-to-code comparison was conducted using COMSOL Multiphysics at UW-Madison and STAR-CCM at MIT, for a forced and mixed convection laminar flow for a grey medium in a vertical heated using both COMSOL Multiphysics at UW-Madison and STAR-CCM at MIT. The relative error was the largest at τ D =40 for the radiative heat flux, bulk temperature, and Nusselt number. On the other hand, the relative error was the least at τ D =0.002 for the conductive heat flux, bulk temperature, and Nusselt number.

Anderson, Mark↗

Impacts of Permeability Heterogeneity and Background Flow on Supercritical CO 2 Dissolution in the Deep Subsurface

Motivated by CO 2 capture and sequestration (CCS) design considerations, we consider the coupled effects of permeability heterogeneity and background flow on the dissolution of a supercritical CO 2 lens into an underlying deep, confined aquifer. We present the results of a large-scale Monte Carlo simulation study examining the interaction of background flow rate and three parameters describing multi-Gaussian log-permeability fields: mean, variance, and correlation length. Hundreds of high-resolution simulations were performed using the PFLOTRAN finite volume software to model CO 2 dissolution in a kilometer-scale aquifer over 1,000 years. Predictive dimensionless scaling relationships relating CO 2 dissolution rate to heterogeneity statistics, Rayleigh (Ra) and Péclet (Pe) numbers were developed for both gravitationally dominated free convection to background flow-dominated forced convection regimes. An empirical criterion, Pe = Ra 3/4 , was discovered for regime transition. All simulations converged quickly to a quasi-steady, approximately linear dissolution rate. However, this rate displayed profound variability between permeability field realizations sharing the same heterogeneity statistics, even under mild permeability heterogeneity. In general, increased heterogeneity was associated with a lower mean and higher variance of dissolution rate, undesirable from a CCS design perspective. The relationship between dissolution rate and background flow was found to be complex and nonlinear. Dimensionless scaling relationships were uncovered for a number of special cases. Results call into question the validity of the Boussinesq approximation in the context of modest-to-high background flow rates and the general applicability of numerical simulations without background flow.

42 ENGINEERING↗

Modeling of the High Temperature Test Facility Using RELAP-7

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is an electrically heated, helium cooled, experimental facility. The HTTF was modeled using RELAP-7 in both 1-D and 3-D for validation. Due to core symmetry, 1/6th of the HTTF core was modeled in 3-D using the coupled heat conduction and forced convection capabilities of RELAP-7. This served as a validation case for RELAP-7 and its capabilities to model advanced nuclear technologies such as high temperature gas-cooled reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Conjugate Heat Transfer Modeling of Salt-Filled Fuel Pins for Stable Salt Reactor Safety Analysis

The Stable Salt Reactor (SSR) combines the proven structural design of light water reactor fuel assemblies with the inherent safety and fuel-cycle advantages of molten salt technology. In its fast reactor configuration, the SSR utilizes recycled nuclear waste as fuel, sealed within narrow salt-filled fuel pins and cooled by a surrounding liquid salt coolant. Reliable transfer of heat from the molten fuel salt through the cladding to the external coolant is essential for both reactor safety and performance. This work investigates conjugate heat transfer (CHT) in the SSR’s salt-filled fuel pins using NekRS, a high-fidelity spectral element computational fluid dynamics (CFD) solver. The analyses capture internal natural convection within the molten fuel salt and external forced convection in the coolant, under steady-state and transient operating conditions. Parametric studies evaluate how variations in reactor power and coolant flow rate influence heat transfer distributions and system response. The high-fidelity CFD results are time-averaged and post-processed for direct comparison with moderate-fidelity Reynolds-averaged Navier–Stokes (RANS) models, and for the development of reduced-order models within the SAM system code. These validated models support fast-running safety analyses of normal and off-normal transients, improving predictive capability for key safety margins. By integrating advanced CFD with system-level safety tools, this study strengthens the modeling framework for SSR design, reduces uncertainty in molten salt CHT simulations, and accelerates the engineering and licensing of next-generation nuclear reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Influences of Environmental Relative Humidity and Horizontal Scale of Subcloud Ascent on Deep Convective Initiation

This study examines two factors impacting initiation of moist deep convection: free-tropospheric environmental relative humidity (φ E ) and horizontal scale of subcloud ascent (R sub ), the latter exerting a dominant control on cumulus cloud width. A simple theoretical model is used to formulate a “scale selection” hypothesis: that a minimum R sub is required for moist convection to go deep, and that this minimum scale decreases with increasing φ E . Specifically, the ratio of R 2 sub to saturation deficit (1 - φ E ) must exceed a certain threshold value that depends on cloud-layer environmental lapse rate. Idealized, large-eddy simulations of moist convection forced by horizontally varying surface fluxes show strong sensitivity of maximum cumulus height to both φ E and R sub consistent with the hypothesis. Increasing R sub by only 300–400 m can lead to a large increase (>5 km) in cloud height. A passive tracer analysis shows that the bulk fractional entrainment rate decreases rapidly with R sub but depends little on φ E . However, buoyancy dilution increases as either R sub or φ E decreases; buoyancy above the level of free convection is rapidly depleted in dry environments when R sub is small. While deep convective initiation occurs with an increase in relative humidity of the near environment from moistening by earlier convection, the importance of this moisture preconditioning is inconclusive as it is accompanied by an increase in R sub . Overall, it is concluded that small changes to R sub driven by external forcing or by convection itself could be a dominant regulator of deep convective initiation.

54 ENVIRONMENTAL SCIENCES↗

Combustion of Butyl acetate as an alternative additive to petroleum fuels

Blending petroleum fuels with oxygenates is a common approach to stem the depletion of crude oil while also mitigating the impact of their combustion on the environment. It has recently been considered that butyl acetate (BA, C6H12O2 , boiling point of 399K) could be a viable oxygenate additive to diesel fuel. The platform used to study combustion of commercial and synthesized BA was an isolated droplet burning with spherical symmetry. The experiments were carried out in a drop tower to minimize buoyant convection. Restricting motion by supporting droplets on 14 micrometer fibers eliminated forced convection. Precise control of the initial diameter was achieved by first deploying large droplets and letting them evaporate to the size of interest, here being between 0.3 mm to 0.8 mm. The experimental results show that commercial and the newly synthesized BA burned almost identically for the evolution of droplet and flame diameters. Droplets burned slower as the initial diameter was increased and soot formation was noted for the larger sizes studied due to a residence size effect. Burning in a buoyant convective field showed higher burn rates due to the convective effect and that the asymmetric flames became nearly spherical as diameter decreased. The study illustrates the significant value that the microgravity environment brings to evaluating performance of oxygenated fuels synthesized by new production methods.

Wang, Yujie↗

Air-Cooled RCCS CFD Modeling Validation 2025

Slide deck for the Advanced Reactor Technologies Gas Cooled Reactor (ART-GCR) program review. The slides show the progress on the air-cooled reactor cavity cooling system (RCCS) CFD validation work. The validation of the air-cooled RCCS is performed using the experimental facility at the University of Wisconsin-Madison. The slide deck provides a progress update on this year's achievements. The natural convection tests under uniform power are modeled and compared with the experimental results. The results show good agreement with the experimental results. A sensitivity study on the RANS turbulence models is performed. Additionally, the contribution of radiative and convective heat transfer within the heated cavity is calculated and compared to forced convection setups.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Numerical Simulations of Orographic Convection across Multiple Gray Zones

Idealized simulations are used to determine the sensitivity of moist orographic convection to horizontal grid spacing Δ h . In simulated mechanically (MECH) and thermally (THERM) forced convection over an isolated ridge, Δ h is varied systematically over both the deep-convection (Δ h ~ 10 –1 km) and turbulence (Δ h ~ 1 km–100 m) gray zones. To aid physical interpretation, a new parcel-based bulk entrainment/detrainment diagnosis for horizontally heterogeneous flows is developed. Within the deep-convection gray zone, the Δ h sensitivity is dominated by differences in parameterized versus explicit convection; the former initiates convection too far upstream of the ridge (MECH) and too early in the diurnal heating cycle (THERM). These errors stem in part from a large underprediction of parameterized entrainment and detrainment. Within the turbulence gray zone, sensitivities to Δh arise from the representation of both subcloud- and cloud-layer turbulence. As Δ h is decreased, MECH exhibits stronger cloud-layer entrainment to enhance the convective mass flux M co , while THERM exhibits stronger detrainment to suppress Mco and delay convection initiation. The latter is reinforced by increased subcloud turbulence at smaller Δ h , which leads to drying and diffusion of the central updraft responsible for initiating moist convection. Numerical convergence to a robust solution occurs only in THERM, which develops a fully turbulent flow with a resolved inertial subrange (for Δ h ≤ 250 m). In MECH, by contrast, turbulent transition occurs within the orographic cloud, the details of which depend on both physical location and Δ h .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical Simulation of a Natural Convection–Driven Air-Cooled Reactor Cavity Cooling System Experiment

Ensuring the efficient removal of decay heat from the reactor vessel is essential for the safety of advanced reactor technologies. Several Generation-IV concepts incorporate variations in the reactor vessel cooling systems to achieve this objective. High-temperature gas-cooled reactors utilize a reactor cavity cooling system (RCCS), a passive ex-vessel system designed to operate without active components or external power during accident conditions. The RCCS removes decay heat primarily through radiative and convective heat transfer mechanisms. Here, this study presents a comprehensive validation of a computational fluid dynamics Reynolds-averaged Navier-Stokes model for the University of Wisconsin-Madison air-cooled RCCS facility. Validation was conducted for both high- and low-power natural convection cases under a uniform heating profile. Near-wall resolution was found to be critical for accurately modeling natural convection in the RCCS; employing an all-𝑦 + wall treatment resulted in wall temperature discrepancies exceeding 50 °⁢𝐶 compared to a wall-resolved mesh. Thermal-hydraulic behaviors under natural and forced convection conditions were compared within the heated cavity and RCCS. A turbulence model sensitivity analysis indicated that low-Reynolds number k-ɛ, k-ω shear stress transport (SST), and Reynolds stress transport models produce similar wall temperature predictions. A buoyancy modeling sensitivity study revealed that the Boussinesq approximation significantly underpredicted thermal-hydraulic behavior in the RCCS. Based on these findings, modeling recommendations are provided. The validated data set along with identified sensitivities refine the modeling of natural convection in the RCCS. The information produced by this study supports RCCS design, optimization, and safety evaluations, enabling the calibration and verification of reduced-order thermal-hydraulic models.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat transfer enhancement due to cold cap motion from bubbling in a waste glass melter

In this study, a computational fluid dynamics (CFD) model was developed to model the motion of a solid cold cap in a waste glass melter. Forced convection bubblers at the base of the melter release air into the molten glass, which forms large bubbles that travel upwards to the cold cap and augment heat transfer from the glass to the cold cap. The CFD model employs the Navier- Stokes equations to solve for the fluctuating flowfield using a rigid body motion dynamic fluid body interaction module. This allows for movement of the floating body in response to the bubbling forces calculated at each time step. Further, the heat flux delivered to the cold cap by the convective bubbling is studied as a function of the bubbling rate. Results for the moving cold cap are compared with the computed heat flux trends for a stationary cold cap. The heat flux delivered to the cold cap from the glass is 25% higher for the case with the moving cold cap. The heat flux was found to be proportional to v0.6 as opposed to v0.9 (where v is the normalized bubbling rate) for the stationary cold cap.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A computational analysis of effective R-values of buried ducts – the dynamic performance of buried ducts

Here, this paper evaluates the thermal performance of ducts partially or fully buried in loose-fill attic insulation. The overall thermal resistance between the ducts and the attic is referred to as an effective R-value. This paper shows a strong dependency of assumed attic temperature on the effective R-value. Based on the results, the effective R-value can be about twice as much with an attic temperature of 130 °F [54.4 °C], compared to when the attic temperature is 80 °F [26.7 °C]. Thus, this paper provides a polynomial regression equation based on a large set of simulations to determine the effective R-value of buried ducts depending on attic temperature and whether the HVAC system runs in cooling or heating mode. Further, the work presented in this paper investigated the potential impact of convective airflow within the attic insulation, particularly around the ducts. The analysis was based on computational fluid dynamics (CFD) and indicated that convectional forces are presented around the exterior surface of the ducts, but with negligible impact on the overall heat balance between the duct and the attic space.

97 MATHEMATICS AND COMPUTING↗

Modelling and analysis of salt-convection effect on oxide reduction process for uranium oxides using smoothed particle hydrodynamics

Oxygen ion transport via molten salt continuum is a key kinetic feature of electrochemical reduction process for uranium oxides in molten salt. During the electrolysis, the evolution of oxygen ion concentration field in molten salt continuum appears from porous metallic layer to open bulk salt. Despite the important role affecting process throughput, its effect coupled with controlled salt movement was not adequately investigated. To capture the reactive oxygen ion transport phenomena, a multidimensional reduction model based on smoothed particle hydrodynamics (SPH) was combined with the advection-diffusion model. A pelletized oxide fuel bed capturing interconnected salt continuum is considered as a reactant material geometry, which allows forced convective delivery of molten salt through the reactant materials with a relatively low pressure head. Here, in this study, reduction time of a pelletized-fuel bed was quantified with respect to key design parameters of the reactant material configuration. The simulation results demonstrated the advantage of salt convection which effectively removes oxygen ion products from the reactant materials and consequently accelerates the reduction process. Moreover, the reduction-time correlation of a single pelletized fuel was developed as a function of relevant dimensionless parameters and was extended to the application for a pelletized-fuel bed. Finally, several insights and implications in the use of a pelletized oxide fuel were presented. The developed SPH-based framework enabled multi-physics analysis of governing dynamics in appreciating and screening candidate reactant material configurations in a cost-effective manner.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗