Search NASA⌕ Search

SEARCH · Search NASA

Results for “Free Field Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

9- by 15-Foot Low-Speed Wind Tunnel Acoustic Free Field Evaluation; Part 1: Qualification Report Summary and Part 2: Anechoic Environment Characterization Field Test Report

This report describes test results from an assessment of the acoustically treated 9x15 Foot Low Speed Wind Tunnel at the NASA Glenn Research Center in Cleveland, Ohio in July of 2016. The tests were conducted in accordance with the recently adopted international standard ISO 26101-2012 on Qualification of Free Field Test Environments. This method involves moving a microphone relative to a source and comparing the sound pressure level versus distance measurements with theoretical inverse square law spreading.

propulsion↗

Spectral signatures of transverse optical modes in semiconductor nanowires

In order to build nanophotonic devices, it is important to understand and ultimately control the optical mode structure within potential components such as nanoscale waveguides. However, experimental characterization of such modes in the optical regime is difficult due to the nanoscale dimensions of such components and the perturbations that would be induced by a near-field probe. Here, we demonstrate a probe-free, far-field method to characterize the optical modes within GaN nanowires (NWs) based on a novel off-axis scanning confocal microscope system. Using this microscope, we observe spectral signatures resulting from lateral leakage of waveguide modes when they exceed their respective cutoff limits. We identify these modes within hyperspectral images using an analytical model coupled with finite element simulations. The model can also be used to predict the spectral signatures for given geometrical and dielectric parameters, which enabled us to deduce the transverse dimension of the NW from hyperspectral images with an accuracy of ∼ <#comment/> 30 nm .

Wang, Maoji↗

9- by 15-Foot Low-Speed Wind Tunnel Acoustic Free-Field Evaluation After Renovation Part 1: Test Report Summary Part 2: Anechoic Environment Characterization: Field Test Report

This report describes test results from an assessment of the acoustically treated 9- by 15-Foot Low Speed Wind Tunnel at the NASA Glenn Research Center in Cleveland, Ohio in June of 2019. The tests were conducted in accordance with the recently adopted international standard ISO 26101-2012 on Qualification of Free Field Test Environments. This method involves moving a microphone relative to a source and comparing the sound pressure level versus distance measurements with theoretical inverse square law spreading.

wind tunnel↗

Joule Heating Effect on Field-Free Magnetization Switching by Spin-Orbit Torque in Exchange-Biased Systems

Switching of magnetization via spin-orbit torque provides an efficient alternative for nonvolatile memory and logic devices. However, to achieve deterministic switching of perpendicular magnetization, an external magnetic field collinear with the current is usually required, which makes these devices inappropriate for practical applications. As such, in this work, we examine the current-induced magnetization switching in a perpendicularly magnetized exchange-biased Pt/CoFe/IrMn system. A magnetic field annealing technique is used to introduce in-plane exchange biases, which are quantitatively characterized. Under proper conditions, field-free current-driven switching is achieved.We study the Joule heating effect, and we show how it can decrease the in-plane exchange bias and degrade the field-free switching. Furthermore, we discuss that the exchange-bias training effect can have similar effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An experimental study of multiple jet mixing

Measurements of an incompressible jet issuing from an array of rectangular lobes, equally spaced with their small dimensions in a line, both as a free jet, and as a confined jet, are carried out in three parts: (1) on a single rectangular free jet, (2) on the same jet in a multiple free jet configuration, and (3) on the same jet in a multiple jet configuration with confining surfaces (two parallel plates are symmetrically placed perpendicular to the long dimension of each lobe covering the entire flow field under consideration). In the case of a single rectangular free jet, the flow field of the jet is characterized by the presence of three distinct regions in the axial mean velocity decay and are referred to as: potential core region, two dimensional type region, and axisymmetric type region. In the case of a multiple free jet, the flow field for downstream distance X greater than 60D (D = width of a lobe) resembles that of a jet exiting from a two dimensional nozzle with its short dimension being the long dimension of the lobe.

Krothapalli, D.↗

Interplanetary Radiation and Internal Charging Environment Models for Solar Sails

A Solar Sail Radiation Environment (SSRE) model has been developed for defining charged particle environments over an energy range from 0.01 keV to 1 MeV for hydrogen ions, helium ions, and electrons. The SSRE model provides the free field charged particle environment required for characterizing energy deposition per unit mass, charge deposition, and dose rate dependent conductivity processes required to evaluate radiation dose and internal (bulk) charging processes in the solar sail membrane in interplanetary space. Solar wind and energetic particle measurements from instruments aboard the Ulysses spacecraft in a solar, near-polar orbit provide the particle data over a range of heliospheric latitudes used to derive the environment that can be used for radiation and charging environments for both high inclination 0.5 AU Solar Polar Imager mission and the 1.0 AU L1 solar missions. This paper describes the techniques used to model comprehensive electron, proton, and helium spectra over the range of particle energies of significance to energy and charge deposition in thin (less than 25 micrometers) solar sail materials.

Minow, Joseph I.↗

Rotor CFD Analysis at Terrestrial and Martian Atmospheric Densities

Much effort has been made to enhance exploration on Mars. In addition to a rover and Mars-orbiting satellites, a Mars helicopter (MH) was proposed in order to augment planetary research. Computational Fluid Dynamics (CFD) simulations have been performed to have a better understanding of the behavior and performance of vertical lift Planetary Aerial Vehicles (PAV). Due to the large differences in atmospheric conditions between Mars and Earth, predicting and testing rotorcraft performance is a complex task. The goal of this project is to understand the capability of the mid-fidelity CFD software RotCFD to predict rotor performance in terms of thrust at 1013.25 milibar and 14 milibar corresponding to Terrestrial and Martian conditions, respectively. Also, in order to characterize the wind tunnel wall effects free field and wind tunnel simulations were performed, analyzed and compared. Different analytical tools have been used in order to aid with the design process for the future vertical lift planetary aerial vehicles. One of them includes experimental tests performed on a rotor in the Aeolian Wind Tunnel (AWT) facility at NASA Ames Research Center under different pressure conditions ranging from Terrestrial to Martian atmospheric conditions. Other software was used as well in order to capture the aerodynamic coefficients of the corresponding rotor sections based on the Mach and Reynolds numbers used for the experimental tests. The aerodynamic coefficients were input into RotCFD, and various simulations were performed under Terrestrial and Martian conditions in order to mimic the experimental test. Then, the obtained results from RotCFD were compared with the AWT collected data.

Atmospheric Pressures↗

Upgrade of the PNNL TEPC and Multisphere Spectrometer

The Pacific Northwest National Laboratory (PNNL) has used two types of instruments, the tissue equivalent proportional counter (TEPC) and the multisphere spectrometer for characterizing neutron radiation fields in support of neutron dosimetry at the Hanford site. The US Department of Energy recently issued new requirements for radiation protection standards in 10 CFR 835 which affect the way that neutron dose equivalent rates are evaluated. In response to the new requirements, PNNL has upgraded the analyses used in conjunction with the TEPC and multisphere. The analysis software for the TEPC was modified for this effort, and a new analysis code was selected for the multisphere. These new analysis techniques were implemented and tested with measurement data that had been collected in previous measurements. In order to test the effectiveness of the changes, measurements were taken in PNNL’s Low Scatter Room using 252Cf sources in both unmoderated and D2O-moderated configurations that generate well-characterized neutron fields. The instruments were also used at Los Alamos National Laboratory (LANL), in their Neutron Free-in-Air calibration room, also using neutron sources that generate well-characterized neutron fields. The results of the software modifications and the measurements are documented in this report. The TEPC measurements performed at PNNL agreed well with accepted dose equivalent rates using the traditional analysis, agreeing with the accepted value to within 13% for both unmoderated and moderated 252Cf sources. When the new analysis was applied to the TEPC measurement data, the results were high compared to the new accepted value. A similar pattern was seen for TEPC measurements at LANL. Using the traditional analysis method, results for all neutron sources showed good agreement with accepted values, nearly always less than 10%. For the new method of analysis, however, the TEPC responded with higher dose equivalent rates than accepted, by as much as 25%. The reason for the overresponse is that there is very little attenuation of the neutrons by tissue, so it cannot match the effect of attenuation by 1 cm of tissue called for in the new standards. This could be corrected with a modified instrument with a thicker wall, or by analytical means that would need to be developed. The multisphere spectrometer performed reasonably well both at PNNL and at LANL. It could produce a neutron spectrum that was similar to the accepted spectrum, and total flux values were usually within 15% of the accepted values. Dose equivalent rates were usually within 18% of the accepted values. The average energies, however, were usually lower than the accepted values. The performance of this instrument could be much better than seen in this study. If PNNL were to add some moderating spheres to its measurement set and calculate a new set of instrument response functions, performance could be improved. The multisphere could then be a more useful instrument for assessing the dose equivalent rate in the workplace.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved electrical properties of free standing blend polymer for renewable energy resources

Blend polymer electrolytes are prepared for salt concentration (Ö/Li = 4) with the constant ratio (0.5 gm) of PEO and PAN using solution casting technique. The prepared free standing solid polymeric film is characterized by Field Emission Scanning Electron Microscopy (FESEM) which confirms the homogeneous distribution of dissociated salt in blend polymer matrix. After addition of salt the ionic conductivity value is found to be of the order of 7.13 × 10{sup −5} Scm{sup −1} which is three orders higher when compared with pure blend polymer films. The microscopic interaction among the polymer-ion, ion-ion has been confirmed by the Fourier Transform Infrared (FTIR) Spectroscopy. A very fine correlation has been built in the electrical conductivity and FTIR result. On the basis of above finding, a prepared free standing solid polymeric film appears to be appropriate for the energy storage/conversion device applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Saturation of tearing modes in reversed field pinches with locally linear force-free magnetic fields and its application to quasi-single-helicity states

A simple formula for predicting the width of a saturated island, formed as a consequence of tearing perturbation of linear force-free fields in cylindrical geometry, is derived. The formula makes it possible to calculate the saturated island width in terms of the values of parameters characterizing the initial force-free equilibrium and can be applied to equilibria of interest for reversed field pinches. In particular it is applied, in this paper, to force-free equilibria with piecewise constant radial profile of the pinch parameter, which have been recently suggested to be relevant for the formation of quasi-single-helicity states. The main result is that the island width becomes larger as a parameter, that quantifies the departure from a relaxed Taylor state, increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral and spatial characterization of rice field mosquito habitat

Irrigated rice provides an ideal breeding habitat for Anopheles free-borni, the western malaria mosquito, throughout California. In a 1985 study, it was determined that early-season rice canopy development, as monitored using remotely sensed data, could be used to distinguish between high and low mosquito producing rice fields. This distinction could be made over two months prior to peak mosquito production. It was found that high-producing fields were located in an area characterized by a diversity of land use, including livestock pastures, whereas the low-producing fields were in an area devoted almost exclusively to the cultivation of rice. The ability to distinguish between high and low mosquito producing fields prior to peak mosquito production is important in terms of mosquito habitat surveillance and control.

Wood, Byron L.↗

Renormalization group flows in a Lifshitz-like four-Fermi model

We study renormalization group flows in the Lifshitz-like N-flavor four-Fermi model discussed in [Phys. Rev. D 80, 105018 (2009)]. In the large-N limit, a nontrivial flow occurs in only one of all possible marginal couplings and one relevant coupling, which provides the scale for Lorentz invariance violations. We discuss in detail the phase diagram and renormalization group flows in the space of couplings, which includes the Lifshitz fixed point, the free field fixed point and a new fixed point characterized by z=1 scaling and a violation of Lorentz invariance, which cannot be tuned away by adjusting a parameter. In the broken symmetry phase, the model flows from the z=3 Lifshitz-like fixed point in the ultraviolet to this new fixed point in the infrared. However, in a modified version of the present model, which has an effective ultraviolet cutoff much smaller than the Lorentz invariance violating scale, the infrared behavior is governed by an approximately Lorentz invariant theory, similar to the low-energy limit of the usual relativistic Nambu-Jona-Lasinio model. Such a modified model could be realized by a supersymmetric version of the present model, if it exists.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-485: Investigation of a Synthetic Diamond Detector for Tomotherapy Dosimetry

Purpose: Tomotherapy treatments are characterized by rotational deliveries of flattening-filter free fields resulting in high-gradient dose distributions. Small volume, rotationally independent detectors are needed for accurate dosimetry. PTWs microDiamond detector, with its small sensitive volume (0.004mm{sup 3}), could potentially be an ideal detector for Tomotherapy. The microDiamond detector was tested against a small volume Exradin A1SL ion chamber for Tomotherapy open-field and IMRT commissioning measurements. Methods: Custom detector holders were fabricated to allow A1SL and microDiamond measurements in the Tomotherapy Cheese phantom and a square solid water phantom. The microDiamond rotational dependence within the Tomotherapy phantom was tested by incrementally rotating the detector in between static-gantry angle Tomotherapy irradiations. Longitudinal Tomotherapy profiles, for all field sizes, were measured with the microDiamond and A1SL detectors at 1.5cm depth in the square phantom, and compared to film. Detector axes were aligned parallel to table motion. Per TG-119 recommendations, both detectors were calibrated to known doses in phantoms and used to measure high-dose points in TG-119 H and N and Prostate plans. The measurements were compared to the treatment planning system and subsequently compared to published TG-119 confidence limits. Results: The microDiamond angular dependence was less than 0.5%. The average difference between the detectors and film-measured longitudinal profile 80–20% penumbras were 0.03+/-0.04mm and 1.36+/-0.22mm for the microDiamond and A1SL, respectively. The average difference between the detector and filmmeasured field sizes were 0.07+/-0.01mm and 0.09+/-0.02mm for the microDiamond and A1SL, respectively. The measured confidence limits were 0.023 and 0.015 for microDiamond and A1SL, respectively. TG-119 reported a confidence limit of 0.034. Conclusion: The microDiamond measured open-field longitudinal Tomotherapy profiles more closely resembled film measurements, compared with the A1Sl chamber. Furthermore, the microDiamond was shown to have low angular dependence and both detectors were able to accurately measure the highdose points in TG-119 H and N and prostate plans. Our institution has research grants with PTW.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal Fault Tolerance Analysis of Carbon Fiber Rope Barrier Systems for Use in the Reusable Solid Rocket Motor ( RSRM) Nozzle Joints

Carbon Fiber Rope (CFR) thermal barrier systems are being considered for use in several RSRM (Reusable Solid Rocket Motor) nozzle joints as a replacement for the current assembly gap close-out process/design. This study provides for development and test verification of analysis methods used for flow-thermal modeling of a CFR thermal barrier subject to fault conditions such as rope combustion gas blow-by and CFR splice failure. Global model development is based on a 1-D (one dimensional) transient volume filling approach where the flow conditions are calculated as a function of internal 'pipe' and porous media 'Darcy' flow correlations. Combustion gas flow rates are calculated for the CFR on a per-linear inch basis and solved simultaneously with a detailed thermal-gas dynamic model of a local region of gas blow by (or splice fault). Effects of gas compressibility, friction and heat transfer are accounted for the model. Computational Fluid Dynamic (CFD) solutions of the fault regions are used to characterize the local flow field, quantify the amount of free jet spreading and assist in the determination of impingement film coefficients on the nozzle housings. Gas to wall heat transfer is simulated by a large thermal finite element grid of the local structure. The employed numerical technique loosely couples the FE (Finite Element) solution with the gas dynamics solution of the faulted region. All free constants that appear in the governing equations are calibrated by hot fire sub-scale test. The calibrated model is used to make flight predictions using motor aft end environments and timelines. Model results indicate that CFR barrier systems provide a near 'vented joint' style of pressurization. Hypothetical fault conditions considered in this study (blow by, splice defect) are relatively benign in terms of overall heating to nozzle metal housing structures.

Clayton, J. Louie↗

Calibration of High Frequency MEMS Microphones

Understanding and controlling aircraft noise is one of the major research topics of the NASA Fundamental Aeronautics Program. One of the measurement technologies used to acquire noise data is the microphone directional array (DA). Traditional direction array hardware, consisting of commercially available condenser microphones and preamplifiers can be too expensive and their installation in hard-walled wind tunnel test sections too complicated. An emerging micro-machining technology coupled with the latest cutting edge technologies for smaller and faster systems have opened the way for development of MEMS microphones. The MEMS microphone devices are available in the market but suffer from certain important shortcomings. Based on early experiments with array prototypes, it has been found that both the bandwidth and the sound pressure level dynamic range of the microphones should be increased significantly to improve the performance and flexibility of the overall array. Thus, in collaboration with an outside MEMS design vendor, NASA Langley modified commercially available MEMS microphone as shown in Figure 1 to meet the new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Over the years, several methods have been used for microphone calibration. Some of the common methods of microphone calibration are Coupler (Reciprocity, Substitution, and Simultaneous), Pistonphone, Electrostatic actuator, and Free-field calibration (Reciprocity, Substitution, and Simultaneous). Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones for wideband frequency ranges; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size. Hence a substitution-based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone.

Shams, Qamar A.↗

Parallel transport of long mean-free-path plasmas along open magnetic field lines: Plasma profile variation

Parallel transport of long mean-free-path plasma along an open magnetic field line is characterized by strong temperature anisotropy, which is driven by two effects. The first is magnetic moment conservation in a non-uniform magnetic field, which can transfer energy between parallel and perpendicular degrees of freedom. The second is decompressional cooling of the parallel temperature due to parallel flow acceleration by conventional presheath electric field which is associated with the sheath condition near the wall surface where the open magnetic field line intercepts the discharge chamber. To the leading order in gyroradius to system gradient length scale expansion, the parallel transport can be understood via the Chew-Goldbeger-Low (CGL) model which retains two components of the parallel heat flux, i.e., q{sub n} associated with the parallel thermal energy and q{sub s} related to perpendicular thermal energy. It is shown that in addition to the effect of magnetic field strength (B) modulation, the two components (q{sub n} and q{sub s}) of the parallel heat flux play decisive roles in the parallel variation of the plasma profile, which includes the plasma density (n), parallel flow (u), parallel and perpendicular temperatures (T{sub Parallel-To} and T{sub Up-Tack }), and the ambipolar potential ({phi}). Both their profile (q{sub n}/B and q{sub s}/B{sup 2}) and the upstream values of the ratio of the conductive and convective thermal flux (q{sub n}/nuT{sub Parallel-To} and q{sub s}/nuT{sub Up-Tack }) provide the controlling physics, in addition to B modulation. The physics described by the CGL model are contrasted with those of the double-adiabatic laws and further elucidated by comparison with the first-principles kinetic simulation for a specific but representative flux expander case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deep-ultraviolet ptychographic pocket-scope (DART): mesoscale lensless molecular imaging with label-free spectroscopic contrast

The mesoscale characterization of biological specimens has traditionally required compromises between resolution, field-of-view, depth-of-field, and molecular specificity, with most approaches relying on external labels. Here we present the Deep-ultrAviolet ptychogRaphic pockeT-scope (DART), a handheld platform that transforms label-free molecular imaging through intrinsic deep-ultraviolet spectroscopic contrast. By leveraging biomolecules’ natural absorption fingerprints and combining them with lensless ptychographic microscopy, DART resolves down to 308-nm linewidths across centimeter-scale areas while maintaining millimeter-scale depth-of-field. The system’s virtual error-bin methodology effectively eliminates artifacts from limited temporal coherence and other optical imperfections, enabling high-fidelity molecular imaging without lenses. Through differential spectroscopic imaging at deep-ultraviolet wavelengths, DART quantitatively maps nucleic acid and protein distributions with femtogram sensitivity, providing an intrinsic basis for explainable virtual staining. We demonstrate DART’s capabilities through imaging of tissue sections, cytopathology specimens, blood cells, and neural populations, revealing detailed molecular contrast without external labels. The combination of high-resolution molecular mapping and broad mesoscale imaging in a portable platform opens new possibilities from rapid clinical diagnostics, tissue analysis, to biological characterization in space exploration.

60 APPLIED LIFE SCIENCES↗