Search NASA⌕ Search

SEARCH · Search NASA

Results for “Freezing tolerance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

33 records · Page 2

Hollow Fiber Spacesuit Water Membrane Evaporator Development and Testing for Advanced Spacesuits

The spacesuit water membrane evaporator (SWME) is being developed to perform the thermal control function for advanced spacesuits to take advantage of recent advances in micropore membrane technology in providing a robust heat-rejection device that is potentially less sensitive to contamination than is the sublimator. Principles of a sheet membrane SWME design were demonstrated using a prototypic test article that was tested in a vacuum chamber at JSC in July 1999. The Membrana Celgard X50-215 microporous hollow fiber (HoFi) membrane was selected after recent contamination tests as the most suitable candidate among commercial alternatives for HoFi SWME prototype development. A design that grouped the fiber layers into stacks, which were separated by small spaces and packaged into a cylindrical shape, was developed into a full-scale prototype consisting 14,300 tube bundled into 30 stacks, each of which are formed into a chevron shape and separated by spacers and organized into three sectors of ten nested stacks. Vacuum chamber testing has been performed characterize heat rejection as a function of inlet water temperature and water vapor backpressure and to show contamination resistance to the constituents expected to be found in potable water produced by the distillation processes. Other tests showed the tolerance to freezing and suitability to reject heat in a Mars pressure environment.

Bue, Grant C.↗

Shuttle Spacelab Core Equipment Freezer

This paper describes the preliminary design of a Shuttle Spacelab Core Equipment Freezer. The unit will provide the capability to freeze and store many experiment specimens. Two models of the unit are planned. One model provides storage at -70 C; the other model will provide -70 C storage, a freeze dry capability, storage at a selectable temperature in the range of 0 C to -70 C, and means of maintaining close temperature tolerances. In addition an exchanger loop will be available at 4 C for cooling of a centrifuge and a remote storage compartment. A test tube holder, a dish holder and thermal capacitors for rapid freezing of large specimens will also be provided. A Stirling Cycle was selected as the active refrigerator for minimum cost and weight.

Copeland, R. J.↗

Aviation turbine fuel properties and their trends

This paper is an examination of published Jet A inspection data covering selected property distributions, averages, and trends for the period from 1969 to 1979. Yearly median values of aromatics, mercaptan sulfur content, 10-percent distillation temperature, smoke point, and freezing point are changing with time, approaching their specification limit values, particularly in the last three years. A near-specification property is defined as one within a stated tolerance band around the specification limit. On this basis, most fuel samples have one to three near-specification properties, the most common being aromatics, smoke point, and freezing point.

Friedman, R.↗

Power Hibernation for Low-Cost Solar Powered Lunar Missions

Because the surface of the Moon drops to cryogenic temperatures, no solar-powered lunar spacecraft have reliably operated beyond a single lunar day. Passive thermal control cannot keep a spacecraft sufficiently warm for the 354-hour lunar night, and active thermal control requires a dramatic increase in battery mass at the expense of payload mass. Extreme conditions seen on the lunar surface suggest a radioisotope solution is ideal, but mass, cost, and schedule are inconsistent with low-cost frequent flight intent of the commercial lunar payload services (CLPS) program. To solve the issue of lunar night survivability without radioisotope sources of power and heat, a lunar power hibernation approach is being developed at the Glenn Research Center, which exploits the ability of common 18650 Lithium-ion cells to passively survive cryogenic freeze-thaw cycles and recover without apparent performance degradation. A key aspect of this hibernation approach is the use of cryogenically operable electronics that safely manage the restoration of the battery thermal environment at lunar dawn. A spacecraft utilizing this strategy will operate into the lunar night on batteries until the state of charge or spacecraft temperature reaches a predetermined threshold. At this point, systems are shut down and the battery is isolated from the main bus to prevent charge or discharge during the freezing and thawing transitions. The system remains passive until lunar dawn, where temperatures can reach as low as 50 K. All electronics must be tolerant to these conditions. When the solar arrays are finally illuminated at lunar dawn, the main bus power electronics will initiate a “cold start” and begin regulating array power. The main bus electronics must be designed to operate at cryogenic temperatures. Array power is used to warm the battery and passive electronics back to operational temperatures. Once batteries are returned to normal temperatures, diagnostics and precharging is performed, as needed, and the battery is reconnected. The overall spacecraft system reboots and returns to nominal operations until lunar night returns. To assure that we can develop batteries suited for many hibernation freeze/thaw cycles, STMD Space Technology Research Grant Program (STRG) has selected two principal investigators that will thoroughly characterize of the Li-ion cell through the freeze-thaw process, investigate degradation mechanisms, and identify potential diagnostic techniques. STMD STRG is also funding an investigation of Gallium-Nitride semiconductors for cryogenic power applications. This work includes physics-informed modeling that considers cryogenic conductivity, carrier mobility, and quantum effects that govern semiconductor performance at cryogenic temperatures. These models can enable engineers to develop accurate cryogenic simulation models that assist in the design of power controls stable over the entire lunar surface temperature range. Meanwhile, Glenn is performing cryogenic testing of batteries and electronics, establishing design guidelines for power applications in extreme cold lunar environment, and potentially developing a hibernation technology demonstrator. The hibernation approach will enable low-cost lunar robotic missions to extend their operating lifetime to many months while minimizing development costs and impact on payload capacity. The need for cryogenically operable electronics is restricted to only main bus power and battery controls, as the majority of systems simply need to passively tolerate cryogenic temperatures. This allows developers to continue to exploit the cost savings of legacy and COTS hardware with minimum modification. For these reasons, lunar power hibernation is a viable near-term solution for lunar night survivability for solar powered commercial landers.

Space power↗

NASA Tech Briefs, November 2007

Topics include: Wireless Measurement of Contact and Motion Between Contact Surfaces; Wireless Measurement of Rotation and Displacement Rate; Portable Microleak-Detection System; Free-to-Roll Testing of Airplane Models in Wind Tunnels; Cryogenic Shrouds for Testing Thermal-Insulation Panels; Optoelectronic System Measures Distances to Multiple Targets; Tachometers Derived From a Brushless DC Motor; Algorithm-Based Fault Tolerance for Numerical Subroutines; Computational Support for Technology- Investment Decisions; DSN Resource Scheduling; Distributed Operations Planning; Phase-Oriented Gear Systems; Freeze Tape Casting of Functionally Graded Porous Ceramics; Electrophoretic Deposition on Porous Non- Conductors; Two Devices for Removing Sludge From Bioreactor Wastewater; Portable Unit for Metabolic Analysis; Flash Diffusivity Technique Applied to Individual Fibers; System for Thermal Imaging of Hot Moving Objects; Large Solar-Rejection Filter; Improved Readout Scheme for SQUID-Based Thermometry; Error Rates and Channel Capacities in Multipulse PPM; Two Mathematical Models of Nonlinear Vibrations; Simpler Adaptive Selection of Golomb Power-of- Two Codes; VCO PLL Frequency Synthesizers for Spacecraft Transponders; Wide Tuning Capability for Spacecraft Transponders; Adaptive Deadband Synchronization for a Spacecraft Formation; Analysis of Performance of Stereoscopic-Vision Software; Estimating the Inertia Matrix of a Spacecraft; Spatial Coverage Planning for Exploration Robots; and Increasing the Life of a Xenon-Ion Spacecraft Thruster.

Source record↗

Design and Testing of an Active Heat Rejection Radiator with Digital Turn-Down Capability

NASA's proposed lunar lander, Altair, will be exposed to vastly different external environment temperatures. The challenges to the active thermal control system (ATCS) are compounded by unfavorable transients in the internal waste heat dissipation profile: the lowest heat load occurs in the coldest environment while peak loads coincide with the warmest environment. The current baseline for this fluid is a 50/50 inhibited propylene glycol/water mixture with a freeze temperature around -35 C. While the overall size of the radiator's heat rejection area is dictated by the worst case hot scenario, a turn-down feature is necessary to tolerate the worst case cold scenario. A radiator with digital turn-down capability is being designed as a robust means to maintain cabin environment and equipment temperatures while minimizing mass and power consumption. It utilizes active valving to isolate and render ineffective any number of parallel flow tubes which span across the ATCS radiator. Several options were assessed in a trade-study to accommodate flow tube isolation and how to deal with the stagnant fluid that would otherwise remain in the tube. Bread-board environmental tests were conducted for options to drain the fluid from a turned-down leg as well an option to allow a leg to freeze/thaw. Each drain option involved a positive displacement gear pump with different methods of providing a pressure head to feed it. Test results showed that a start-up heater used to generate vapor at the tube inlet held the most promise for tube evacuation. Based on these test results and conclusions drawn from the trade-study, a full-scale radiator design is being worked for the Altair mission profile.

Sunada, Eric↗

Experimental Effervescence and Freezing Point Depression Measurements of Nitrogen in Liquid Methane-Ethane Mixtures

NASA is designing an unmanned submarine to explore the depths of the hydrocarbon-rich seas on Saturn's moon Titan. Data from Cassini indicates that the Titan north polar environment sustains stable seas of variable concentrations of ethane, methane, and nitrogen, with a surface temperature near 93 K. The submarine must operate autonomously, study atmosphere/sea exchange, interact with the seabed, hover at the surface or any depth within the sea, and be capable of tolerating variable hydrocarbon compositions. Currently, the main thermal design concern is the effect of effervescence on submarine operation, which affects the ballast system, science instruments, and propellers. Twelve effervescence measurements on various liquid methane-ethane compositions with dissolved gaseous nitrogen are thus presented from 1.5 bar to 4.5 bar at temperatures from 92 K to 96 K to simulate the conditions of the seas. After conducting effervescence measurements, two freezing point depression measurements were conducted. The freezing liquid line was depressed more than 15 K below the triple point temperatures of pure ethane (90.4 K) and pure methane (90.7 K). Experimental effervescence measurements will be used to compare directly with effervescence modeling to determine if changes are required in the design of the thermal management system as well as the propellers.

Submarine↗

Reliable Power Hibernation and Recovery for Solar Powered Lunar Missions

NASA Glenn Research Center has been working on a solution to surviving the lunar night based on the discovery that Li-Ion cells can survive the freeze/thaw process. This implies that a lunar surface spacecraft could hibernate through the coldest portions of the night and recover at lunar dawn. Survival and recovery also depend on power electronics capable of tolerating the cold and reliably starting at lunar dawn based on solar array output alone. GRC is working with STMD Space Technology Research Grant investigators to characterize Li-ion cells through the freeze-thaw process and fully understand the electro-chemical and thermal-mechanical processes to assure reliable cell hibernation and recovery. Further, we are working with investigators to determine what power semiconductor material, transistor technology, and power architecture is best suited for reliable cold start at lunar dawn and methodically restoring the power system to full operation for the next lunar cycle.

Spacecraft Power↗

Advanced Liquid-Cooling Garment Using Highly Thermally Conductive Sheets

This design of the liquid-cooling garment for NASA spacesuits allows the suit to remove metabolic heat from the human body more effectively, thereby increasing comfort and performance while reducing system mass. The garment is also more flexible, with fewer restrictions on body motion, and more effectively transfers thermal energy from the crewmember s body to the external cooling unit. This improves the garment s performance in terms of the maximum environment temperature in which it can keep a crewmember comfortable. The garment uses flexible, highly thermally conductive sheet material (such as graphite), coupled with cooling water lines of improved thermal conductivity to transfer the thermal energy from the body to the liquid cooling lines more effectively. The conductive sheets can be layered differently, depending upon the heat loads, in order to provide flexibility, exceptional in-plane heat transfer, and good through-plane heat transfer. A metal foil, most likely aluminum, can be put between the graphite sheets and the external heat source/sink in order to both maximize through-plane heat transfer at the contact points, and to serve as a protection to the highly conductive sheets. Use of a wicking layer draws excess sweat away from the crewmember s skin and the use of an outer elastic fabric ensures good thermal contact of the highly conductive underlayers with the skin. This allows the current state of the art to be improved by having cooling lines that can be more widely spaced to improve suit flexibility and to reduce weight. Also, cooling liquid does not have to be as cold to achieve the same level of cooling. Specific areas on the human body can easily be targeted for greater or lesser cooling to match human physiology, a warmer external environment can be tolerated, and spatial uniformity of the cooling garment can be improved to reduce vasoconstriction limits. Elements of this innovation can be applied to other embodiments to provide effective heat transfer over a flexible and surface-conformable fashion without the limitation of fluid freeze points.

Ruemmele, Warren P.↗

Acceptable Tolerances for Matching Icing Similarity Parameters in Scaling Applications

This paper reviews past work and presents new data to evaluate how changes in similarity parameters affect ice shapes and how closely scale values of the parameters should match reference values. Experimental ice shapes presented are from tests by various researchers in the NASA Glenn Icing Research Tunnel. The parameters reviewed are the modified inertia parameter (which determines the stagnation collection efficiency), accumulation parameter, freezing fraction, Reynolds number, and Weber number. It was demonstrated that a good match of scale and reference ice shapes could sometimes be achieved even when values of the modified inertia parameter did not match precisely. Consequently, there can be some flexibility in setting scale droplet size, which is the test condition determined from the modified inertia parameter. A recommended guideline is that the modified inertia parameter be chosen so that the scale stagnation collection efficiency is within 10 percent of the reference value. The scale accumulation parameter and freezing fraction should also be within 10 percent of their reference values. The Weber number based on droplet size and water properties appears to be a more important scaling parameter than one based on model size and air properties. Scale values of both the Reynolds and Weber numbers need to be in the range of 60 to 160 percent of the corresponding reference values. The effects of variations in other similarity parameters have yet to be established.

Anderson, David N.↗

Long Duration Testing of a Spacesuit Water Membrane Evaporator Prototype

The Spacesuit Water Membrane Evaporator (SWME) is a heat-rejection device that is being developed to perform thermal control for advanced spacesuits. Cooling is achieved by circulating water from the liquid cooling garment (LCG) through hollow fibers (HoFi?s), which are small hydrophobic tubes. Liquid water remains within the hydrophobic tubes, but water vapor is exhausted to space, thereby removing heat. A SWME test article was tested over the course of a year, for a total of 1200 cumulative hours. In order to evaluate SWME tolerance to contamination due to constituents caused by distillation processes, these constituents were allowed to accumulate in the water as evaporation occurred. A test article was tested over the course of a year for a total of 1200 cumulative hours. The heat rejection performance of the SWME degraded significantly--below 700 W, attributable to the accumulation of rust in the circulating loop and biofilm growth. Bubble elimination capability, a feature that was previously proven with SWME, was compromised during the test, most likely due to loss of hydrophobic properties of the hollow fibers. The utilization of water for heat rejection was shown not to be dependent on test article, life cycle, heat rejection rate, or freezing of the membranes.

Bue, Grant C.↗

Long Duration Testing of a Spacesuit Water Membrane Evaporator Prototype

The Spacesuit Water Membrane Evaporator (SWME) is a heat-rejection device that is being developed to perform thermal control for advanced spacesuits. Cooling is achieved by circulating water from the liquid cooling garment (LCG) through hollow fibers (HoFi s), which are small hydrophobic tubes. Liquid water remains within the hydrophobic tubes, but water vapor is exhausted to space, thereby removing heat. A SWME test article was tested over the course of a year, for a total of 600 cumulative hours. In order to evaluate SWME tolerance to contamination due to constituents caused by distillation processes, these constituents were allowed to accumulate in the water as evaporation occurred. A test article was tested over the course of a year for a total of 600 cumulative hours. The heat rejection performance of the SWME degraded significantly--below 700 W, attributable to the accumulation of rust in the circulating loop and biofilm growth. Bubble elimination capability, a feature that was previously proven with SWME, was compromised during the test, most likely due to loss of hydrophobic properties of the hollow fibers. The utilization of water for heat rejection was shown not to be dependent on test article, life cycle, heat rejection rate, or freezing of the membranes.

Bue, Grant C.↗

Increase of cold tolerance in cotton plant (Gossypium hirsutum L.) by mepiquat chloride

Three mepiquat chloride (MC) concentrations - 40, 70, and 100 g a.i./ha - were used to spray cotton (Gossypium hirsutum L., cultival McNair 220) plants to determine whether or not MC would increase their cold tolerance. Seven to ten days after the spray, the plants were exposed to three different cold treatments. No important difference in cold damage was noticed between the control and the MC-treated plants when they were exposed repeatedly to 4.5 C. No plants died when exposed to 0.5 C for 12 h; however, 90% of the 1st and 2nd leaves of the control plants were damaged. This was three times more damage than those leaves of plants treated with 70 and 100 g a.i./ha MC concentrations; 60% f the control and 10-20% of the MC-treated plants died when the plants were subjected to a cold hardening process with 15.5 C day (12 h) and 1.7 C night (12 h) for 10 days, and then, held at -2.2 C for 24 hours. The electrolyte leakage and reflectance measurement data showed that the cell membranes of the MC-treated plants sustained much less damage than those of the control. Freezing injury was easily assessed by reflectance measurements at the 1.65 micrometer wavelength.

Gausman, H. W.↗

Heat Rejection Systems Utilizing Composites and Heat Pipes: Design and Performance Testing

Polymer matrix composites offer the promise of reducing the mass and increasing the performance of future heat rejection systems. With lifetimes for heat rejection systems reaching a decade or more in a micrometeoroid environment, use of multiple heat pipes for fault tolerant design is compelling. The combination of polymer matrix composites and heat pipes is of particular interest for heat rejection systems operating on the lunar surface. A technology development effort is under way to study the performance of two radiator demonstration units manufactured with different polymer matrix composite face sheet resin and bonding adhesives, along with different titanium-water heat pipe designs. Common to the two radiator demonstration units is the use of high thermal conductivity fibers in the face sheets and high thermal conductivity graphite saddles within a light weight aluminum honeycomb core. Testing of the radiator demonstration units included thermal vacuum exposure and thermal vacuum exposure with a simulated heat pipe failure. Steady state performance data were obtained at different operating temperatures to identify heat transfer and thermal resistance characteristics. Heat pipe failure was simulated by removing the input power from an individual heat pipe in order to identify the diminished performance characteristics of the entire panel after a micrometeoroid strike. Freeze-thaw performance was also of interest. This paper presents a summary of the two radiator demonstration units manufactured to support this technology development effort along with the thermal performance characteristics obtained to date. Future work will also be discussed.

Jaworske, Donald A.↗