Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fuel cell stack efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Laser 3D printing of highly compacted protonic ceramic electrolyzer stack

Solid oxide electrolysis cells (SOECs) for H 2 production is a core technology for H2@scale. However, its conventional manufacturing methods adapted from the manufacture of solid oxide fuel cells (SOFC) need high cost, especially for small-volume production. The emerging laser 3D printing (L3DP) technology with computer-aided 3D printing and computer-controlled laser processing can fulfill layer-by-layer digital shaping and rapid in-situ consolidating feedstock into complicated geometries. L3DP, a promising additive manufacturing (AM) technology, has achieved significant success in manufacturing plastic and metal parts, which is currently attracting considerable attention for the cost-effective, rapid, and flexible manufacturing of heterogeneous multilayered ceramic devices (e.g., SOECs, SOFCs, and solid-state batteries). It is believed that the L3DP can integrate the advantages of selective consolidation of heterogeneous layers, accurate control of layer microstructures, high processing heat efficiency, high processing speed, high stack compactness, high stack design flexibility, and low stack sealing area for cost-effective, rapid, and flexible manufacturing of SOECs to meet DOE’s electrolyzer target.

08 HYDROGEN↗

Titanium-Cerium Electrode-Decoupled Redox Flow Batteries Integrated With Fossil Fuel Assets For Load-Following, Long-Duration Energy Storage

Operation of fossil plants at partial capacity with frequent cycling results in decreased efficiency, increased emissions and increased wear and maintenance. The objective of this project is to advance the integration of a titanium-cerium electrode-decoupled redox flow battery (RFB) system with conventional fossil-fueled power plants through technical and economic system-level studies and component scale-up and R&D. The Ti-Ce chemistry has a pathway to meet the DOE cost targets of $\$$100/kWh and $\$$0.05/kWh-cycle owing to the use of low-cost, earth abundant elemental actives and incorporation of inexpensive carbon felt electrodes and non-fluorinated anion exchange membrane (AEM) separators. The initial unit cell design was scaled up, with some modifications made to improve ease of manufacturing, from 25 cm 2 cell area to 400 cm 2 . Electrochemical tests demonstrated operation at a current density up to 50 mA/cm 2 , which is on par with other commercial RFB offerings. Furthermore, the Ti-Ce technology developed by WashU was evaluated and tested by industrial team partner, Giner, Inc., in their modular 3-cell stack. Several cell design modifications and alternate component material selections were successfully implemented to accommodate this chemistry while reducing polarization and leakage. Results from stack testing show high columbic efficiency and indicate that further optimization of cell compression and components will lead to successful operation of the Ti-Ce ED-RFB over longer duration at the multi-cell stack level. Engineering and cost analysis showed that an RFB system with power output on the order of 100 MW and with a charge/discharge duration of approx. 12 hours is the most cost effective for integration with fossil plants. At this scale, projected cycling of fossil fuel power plants can be significantly reduced. The use of a storage system is shown to reduce the fossil plant standalone cost of electricity by $\$$7/MWh, through increased capacity factor and improved average efficiency, in the scenario of high penetration of renewable power.

20 FOSSIL-FUELED POWER PLANTS↗

Operando X-Ray Diffraction During High Temperature Electrolysis

This work presents the design, development, and deployment of an operando X-ray diffraction (XRD) system for high-temperature electrolysis (HTE), enabling real-time characterization of solid oxide electrolysis cells (SOECs) under true operational conditions. The integration of an HTE test stand within a synchrotron radiation environment, mimicking the conditions of a laboratory setup, aims to enhance our understanding of the degradation processes affecting the performance and longevity of SOECs. Utilizing a custom furnace and a high precision motor stack assembly at the Stanford Synchrotron Radiation Lightsource (SSRL), the system revealed unparalleled insights into the structural evolution of SOEC components through various operational stages, including initial heat ramp, cell reduction, fuel ramp, and wet electrolysis. Initial results demonstrate the significant impact of the initial heating and cooling on secondary phase formation within the SOEC, highlighting the utility of operando XRD for developing more efficient and durable hydrogen production technologies.

08 HYDROGEN↗

Stress evolution and creep deformation in solid-oxide electrolysis cell systems – Dynamic modeling and multi-objective optimization to maximize stack life and efficiency

Here, this study develops a thermal stress model of solid-oxide electrolysis cells (SOECs) including a model for creep strain and failure probability that is integrated with a dynamic plant-wide model of a hydrogen production process. Uncertainties in key material properties of the cell are quantified to assess their impact on stress profile variability. The oxygen electrode is found to have about 10 times higher failure probability compared to the fuel electrode. The study shows that if the stack operation is not optimized, cycling operation would lead to stress build-up eventually leading to catastrophic failure. A dynamic optimization problem is set up for obtaining the optimal operational profile considering a variable hydrogen production rate. Due to the tradeoff between the efficiency and stress build-up, the dynamic optimization problem is multi-objective. It is observed that the optimizer can considerably reduce the stress build-up (i.e., can increase the stack life) albeit at the cost of a lower efficiency thus exhibiting strong tradeoffs between capital and operating costs. For example, if the stack would be replaced in 0.5 yr, specific energy requirement would be 48.5 kWh/kg H 2 while for a stack replacement time of about 6 yr, the specific energy requirement rises by about 4.2 %.

SOEC↗

Investigating realistic anode off-gas combustion in SOFC/ICE hybrid systems: mini review and experimental evaluation

Solid oxide fuel cells (SOFCs) have been deployed in hybrid decentralized energy systems, in which they are directly coupled to internal combustion engines (ICEs). Prior research indicated that the anode tailgas exiting the SOFC stack should be additionally exploited due to its high energy value, with typical ICE operation favoring hybridization due to matching thermodynamic conditions during operation. Consequently, extensive research has been performed, in which engines are positioned downstream the SOFC subsystem, operating in several modes of combustion, with the most prevalent being homogeneous compression ignition (HCCI) and spark ignition (SI). Experiments were performed in a 3-cylinder ICE operating in the latter modus operandi, where the anode tailgas was assimilated by mixing syngas (H 2 : 33.9%, CO: 15.6%, CO 2 : 50.5%) with three different water vapor flowrates in the engine’s intake. While increased vapor content significantly undermined engine performance, brake thermal efficiency (BTE) surpassed 34% in the best case scenario, which outperformed the majority of engines operating under similar operating conditions, as determined from the conducted literature review. Nevertheless, the best performing application was identified operating under HCCI, in which diesel reformates assimilating SOFC anode tailgas, fueled a heavy duty ICE (17:1), and gross indicated thermal efficiency ([Formula: see text]) of 48.8% was achieved, with the same engine exhibiting identical performance when operating in reactivity-controlled compression ignition (RCCI). Overall, emissions in terms of NO x and CO were minimal, especially in SI engines, while unburned hydrocarbons (UHC) were non-existent due to the absence of hydrocarbons in the assessed reformates.

Engineering↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗

Performance and Durability of Hybrid Fuel Cell Systems for Class-8 Long Haul Trucks

Hybrid fuel cell-battery configurations are investigated that overcome thermal management issues in fuel cell powertrains for heavy-duty Class 8 trucks. The battery is sized so that it has sufficient capacity to provide supplemental power and energy on a hill climb transient at end-of-life. A dynamic load sharing strategy is developed to distribute the power demand between the fuel cell system (FCS) and the energy storage system in a manner that optimizes their lifetimes. The FCS end-of-life is identified as the terminal point beyond which the stack cannot generate the rated power with target power density at 0.7 V and 40 °C ambient temperature. Reaching the target lifetime with a-Pt/C cathode catalyst in one hybrid configuration requires voltage clipping to 813 mV, idle power limited to 50 kW, catalyst overloading to 0.45 mg cm -2 total Pt in anode and cathode, and 44% active membrane area oversizing. The stack and FCS drive cycle efficiencies decrease by 4.2% and 5.4%, respectively, during the electrode lifetime. Further, the FCS performance, durability and cost are compared with the targets of 68% peak efficiency, 0.30 mg cm -2 total Pt loading, 2.5 kW/g PGM Pt group metal (PGM) loading, 750 mW cm -2 power density, 25,000-h lifetime and $80/kW cost.

33 ADVANCED PROPULSION SYSTEMS↗

Performance and cost of fuel cells for off-road heavy-duty vehicles

Hydrogen fuel cell-powered off-road vehicles can replace hydrocarbon-powered off-road vehicles to reduce carbon dioxide and criteria pollutant emissions in the agriculture, construction, and mining industries. Vehicle manufacturers and customers recognize health and environmental benefits of emissions reductions but are ultimately compelled by the total cost of ownership of their vehicles. In this study, we conduct a technoeconomic evaluation for three hallmark off-road vehicles, tractors, wheel loaders, and excavators, comparing vehicles with hydrogen fuel cell + battery hybrid powertrains to traditional diesel powertrains. Stakeholder-valued performance metrics include fuel cell engine power, engine durability, hydrogen consumption rate, hydrogen storage system volume, and energy-regenerative drivetrain efficiency. The total cost of ownership includes capital, operating and maintenance, fuel, and fuel storage costs. State-of-the-art fuel cell powered wheel loaders and excavators are currently cost competitive with diesel platforms. If targeted improvements to cost, performance, and durability improvements of fuel cell stacks and storage systems are achieved, fuel cell systems would be cost competitive for tractors and significantly lower total cost of ownership options for wheel loaders and excavators.

33 ADVANCED PROPULSION SYSTEMS↗

SPUTTERED THIN FILMS FOR VERY HIGH POWER, EFFICIENT, AND LOW-COST COMMERCIAL SOFCS

The aim of this project was to leverage the low area specific resistance (ASR) of Redox’s GDC electrolyte-based cell architecture and increase solid oxide fuel cell (SOFC) efficiency (i.e., open circuit voltage, or OCV) without significantly increasing cell resistance. The key to achieving the increased SOFC efficiency is the introduction of a thin sputtered yttria stabilized zirconia (YSZ) electron-blocking layer and a thin sputtered gadolinia doped ceria (GDC) barrier layer on top of the half-cell substrate (i.e., anode and GDC electrolyte). A key initial effort of the project was to improve the quality of the half-cell substrate surface so that any remaining defects were significantly smaller than the desired film thickness. During lab-scale trials, we had to overcome challenges with film cracking during post-sputtering treatments (e.g., thermal anneals) as well as damage to the sputtering targets. After the initial lab-scale trials, the focus shifted toward the use of commercial scale sputtering equipment with a sputtering equipment manufacturer in the microelectronics industry. Using the commercial sputtering equipment, we deposited films with different variations of power, PO2, sputtering time, platen speed, etc. We then determined the combinations of sputtering conditions and post-sputtering treatments that yielded high-quality films without cracks or other significant defects. While thin films were deposited on cells as large as 10 cm by 10 cm, the processing was optimized using 4 cm by 4 cm cells. Cell performance was evaluated in stainless-steel test fixtures between 500 °C and 700 °C with hydrogen fuel fed to the anode and air fed to the cathode. Extensive studies allowed us to determine that modified cathode and cathode contact firing processes were required to achieve theoretical OCV. Moreover, use of the new firing processes resulted in the need for a modified cathode contact to achieve a low ASR. In summary, the project demonstrated the performance of high OCV (1.13 V at 650 °C) from sputtered layers and a low ASR (~0.25 Ohms-cm2 at 650 °C) resulting from a modification of cathode/contact processing and the introduction of alternative contact layers that are sufficient to yield a Gen-1 cell with a maximum power density of approximately 1.2 W/cm2. At an operating voltage of 0.74 V, this would yield a cell power density of ~1.1 W/cm2. While not utilized in this project, a Redox Gen-2 cell has a catalyst-infiltrated porous anode that reduces the ASR by more than 50% from that of the Gen-1 cells used in this project. Therefore, if the sputtered YSZ electron-blocking layer and GDC barrier layer are added to a Gen-2 half cell with a similar increase in OCV to the theoretical value of ~1.13 V at 650 °C, and if the same improvement in ASR (from that demonstrated in this project) is achieved when using the Gen-2 half-cell architecture as a sputtered cell substrate, then the power density at 0.74 Vop could be as high as ~2.6 W/cm2. The impact of such power density gains, while still maintaining high cell efficiency, and thus high system efficiency, is a dramatic decrease in system cost because the stack represents ~30-40% of the SOFC system cost.

01 COAL, LIGNITE, AND PEAT↗

High Efficiency and Transient Air Systems for Affordable Load-Following Heavy Duty Truck Fuel Cells

Hydrogen fuel cell powered vehicles are one of the potential paths to reducing vehicle emissions. An important subsystem of the hydrogen fuel cell system is an air handling system that provides the needed oxygen (in air) to react with hydrogen in the fuel cell stack for electric power generation. Today’s systems use an electric motor to power an air compressor that supplies oxygen to the fuel cell stack. This process requires significant electrical power and is the largest parasitic power loss in hydrogen fuel cell vehicles. In addition to parasitic power loss, hydrogen fuel cell systems often have reliability issues associated with the air handling system. Reliability is of significant concern for heavy duty applications (especially long-haul applications). This project aims to improve both the electrical power consumption and reliability of hydrogen fuel cell air handling systems to meet the needs of heavy duty on-highway vehicle applications.

08 HYDROGEN↗

Developing Stable Critical Materials and Microstructure for High-Flux and Efficient Hydrogen Production through Reversible Solid Oxide Cells

Reversible Solid Oxide Cells (RSOCs), which operate as either Solid Oxide Fuel Cells (SOFCs) or Solid Oxide Electrolytic Cells (SOECs), hold great promise for clean, high-efficiency energy conversion and hydrogen production. However, their commercial potential is hindered by stability issues arising from temperature-induced materials degradation. While substantial progress has been made in developing durable, reduced-temperature SOFCs - bringing them closer to commercial deployment, SOECs still exhibit substantially higher degradation rates at both the cell and stack levels under practical operating conditions.

08 HYDROGEN↗

Recent developments in catalyst-related PEM fuel cell durability

Cost and durability remain the two major barriers to the widespread commercialization of polymer electrolyte membrane fuel cell (PEMFC)-based power systems, especially for the most impactful but challenging fuel cell electric vehicle (FCEV) application. Commercial FCEVs are now on the road; however, their PEMFC systems do not meet the cost targets established by the U.S. Department of Energy, primarily due to the high platinum loading needed on the cathode to achieve the requisite performance and lifetime. Furthermore, while the activities of a number of commercial Pt-based alloy cathode catalysts exceed the beginning-of-life (BOL) targets, these activities, and the overall cathode performance, degrade via a variety of mechanisms described herein. Degradation is mitigated in current FCEVs by utilizing a cathode catalyst with a lower BOL activity (e.g., much lower transition metal alloy content and larger BOL nanoparticle size), necessitating higher catalyst loadings, and through the utilization of system controls that avoid conditions known to exacerbate degradation processes, such as limiting the fuel cell stack voltage range. The design and development of active and robust materials and eliminating the need for vehicle mitigation strategies would greatly simplify the operating system, allowing for greater transient operation, avoiding large hybridization, and curtailing of fuel cell power. Although system mitigation strategies have provided the near-term pathway for FCEV commercialization, material-specific solutions are required to further reduce costs and improve operability and efficiency. Future material developments should focus on stabilization of the electrode structure and minimization of the catalyst particle susceptibility to dissolution caused by oxide formation and reduction over PEMFC cathode-relevant operating potentials plus minimization of support corrosion. Ex situ accelerated stress tests have provided insight into the processes responsible for material and performance degradation and will continue to provide useful information on the relative stability of materials and benchmarks for robust and stable materials-based solutions not requiring system mitigation strategies to achieve adequate lifetime.

25 ENERGY STORAGE↗

Preliminary Reversible Solid Oxide System Specification

This report presents the preliminary documentation of a 10 MWe DC reversible solid oxide cell (rSOC) system designed to use both electrical and thermal energy from a nuclear power plant (NPP). The system is designed to consume 10 MWe DC in electrolysis mode while producing hydrogen from demineralized feedwater. In fuel cell mode, the same stacks produce 2.37 MWe DC of electricity by reacting hydrogen and oxygen, while generating water as a byproduct which is recycled to be used later in the electrolysis mode. The system detailed in this specification is a high-temperature steam electrolysis (HTSE) system when operated in the electrolysis mode. HTSE systems have the benefit of producing hydrogen at a higher efficiency than conventional low-temperature electrolysis (LTE) systems. In this report it is assumed that some of the heat required for HTSE operation comes from an NPP. Heat extraction from an NPP for use in electrolysis mode of the rSOC system allows preheating and vaporization of feedwater before recuperators and trim heaters raise the feed temperature to the approximately 800 °C before entering the solid oxide stacks. The purpose of an rSOC system in a utility company setting is to employ energy arbitrage with a dispatchable demand load which can consume excess electricity generation during times of low grid demand / high generation and can produce electricity for the grid during times of high grid demand / low generation. There is a wide range of energy storage technologies that could be used for utility-scale energy arbitrage (utility-scale battery storage is considered the baseline technology), the object of this work is not to compare and contrast rSOC technology with any of these other technologies, but only to present this preliminary design for consideration and for use in future conceptual or front end engineering design (FEED) work. This document is not meant to be a final specification or definitive description of the rSOC system, but it is meant to showcase preliminary process modeling results, provide boundary conditions and interface requirements such as input feed and utility stream flowrates, temperatures, and pressures as well as thermal and electrical energy requirements, and output conditions in both electrolysis mode and fuel cell mode. These results are intended to inform the future development of a conceptual demonstration-scale study to assess the technical and economic feasibility of a future demonstration of an rSOC integrated project at an NPP.

08 HYDROGEN↗

Corrosion resistance of functionally graded TiN/Ti coatings for proton exchange membrane fuel cells

Bipolar Plates (BPP) are important components of proton exchange membrane fuel cell (PEMFC) stacks. In the development of innovative fuel cell designs, it is advantageous to use aluminum for these applications, however, this material lacks the necessary corrosion resistance. Since the performance of PEMFC stacks depends on BPP properties, in particular, corrosion resistance, depositing titanium nitride (TiN) thin films onto aluminum substrates may improve their efficiency and durability. Present work focuses on improving corrosion resistance and hydrophobicity of TiN/Ti by using N graded films deposited onto aluminum substrates (AA-1100) by grid-assisted magnetron sputtering (GAMS). Electrochemical impedance spectroscopy (EIS) with potentiodynamic and potentiostatic polarization are used to investigate the performance of the substrate/film system at room temperature and 70 oC, thus simulating a prototypic PEMFC electrolyte environment. Electrochemical test results showed that graded TiN films improved corrosion resistance when compared with both the homogeneous films and the AA1100 uncoated substrate. Furthermore, contact angle results reveal improved hydrophobicity for both homogeneous and graded TiN coatings when compared with the AA1100 substrate.

25 ENERGY STORAGE↗

Thermo-economic analysis of a solid oxide fuel cell-gas turbine hybrid with commercial off-the-shelf gas turbine

The thermodynamic and economic performance of a natural gas-fueled solid oxide fuel cell (SOFC)-gas turbine (GT) hybrid system with a commercial off-the-shelf GT is investigated. Until today, commercial GTs are primarily engineered for the direct use of energy dense fuels, such as natural gas, and the integration of commercial GTs into a SOFC-GT hybrid remains challenging. In this work technically feasible and economically viable GT operating modes are identified to gauge the technology’s competitiveness on the free market. Steady state, full load operating conditions were established for various GT operating modes: I) constant spool speed operation, II) variable spool speed operation and III) partially closed compressor inlet guide vanes. For each GT operating mode, the performance was investigated over a range of SOFC fuel utilization factors, while considering physical constraints inside the SOFC, such as local temperature gradients in flow direction as well as overall cell temperature differences. The results of the thermodynamic evaluation served as inputs for the economic analysis of the SOFC-GT hybrid power plant. The results show that the integration of an off-the-shelf GT not only results in a significant derating of the GT, but also substantially impacts the SOFC operation, the main power producer in this SOFC-GT hybrid. To maximize the SOFC power output it is desirable operate the GT in a region of high air mass flow rates and low pressure ratios, which increases the number of stacks that can be accommodated and reduces the SOFC cooling requirement. The lowest costs of electricity are obtained at constant spool speed operation, while the highest efficiencies are reached at variable spool speed operation. Critical for the integration of off-the-shelf GTs, which historically have been designed for natural gas, is the surge margin. The largest surge margins are obtained by closing the compressor inlet guide vanes. Furthermore, higher SOFC fuel utilization factors are shown to increase the surge margin as the turbine firing temperature is decreased.

25 ENERGY STORAGE↗

Reversible solid oxide cells: Early performance and microstructural evolution during electrolysis and switched mode operation

Incorporating more renewables into our energy mix will require a diversity of technological solutions. Reversible solid oxide cell systems (RSOCs) operating reversibly between fuel cell and electrolysis modes with high round-trip efficiencies offer one such solution. However, questions remain about the stability of the oxygen and fuel electrodes under reversible operation. Here, in this study, single cells with the configuration Ni-YSZ|YSZ|GDC10|NNO-NDC50|NNO are operated by reversible cycling under potentiostatic conditions. Test conditions are chosen to be representative of average stack conditions that are likely to be encountered during operation of a stack constructed of such cells. The results of reversible cycling over 500 h (21 cycles) are compared with operating the cells under potentiostatic conditions in the electrolysis-only mode (i.e., without cycling). Voltage-current density (DC), AC complex impedance spectroscopy, distribution of relaxation times (DRT) analysis, and scanning electron microscopy (SEM) indicate excellent reversibility and stability of the neodymium nickelate-based oxygen electrodes in both electrolysis and reversible cycling modes. Degradation behavior is attributed to the loss and coarsening of connected Ni particles in the fuel electrode, particularly in the active layer. However, reversible operation mitigates this degradation compared to operation in the electrolysis-only (SOEC-only) mode.

25 ENERGY STORAGE↗

Integrated protonic ceramic electrochemical cell for sustainable energy economy using water-energy nexus framework

Reliance on fossil fuels will continue for the next decades even though there are global pushes away from it to mitigate the overarching climate challenge, most especially by its highest consumers and availability. While there is a hastening global shift away from fossil fuel, integrating its assets into this technology helps limit the risk and future losses of stranded assets and reduce the cost of investment in the new technologies. Moreover, the generation of electricity from intermittent renewable sources like solar and wind has witnessed a significant surge in recent years, leading to a pressing demand for practical energy storage systems. Electrical energy storage is anticipated to play a pivotal role in the future global energy system, facilitating load-leveling operations to support the greater integration of renewable and distributed generation. Reversible electrochemical cells (RECs) offer a promising option for addressing the fossil fuel assets integration and energy storage challenges through the interconversion between electrical and chemical energy and concurrent utilizing carbon emission. In their electrolysis mode, the RECs convert electricity into durable, storable, and portable valuable chemical fuels such as syngas and methane. Conversely, the produced chemical fuels can be used as reactants in the fuel cell mode to generate electricity on demand with minimal (hydrocarbons) or zero when H2 or NH3 is used emissions. However, a challenging goal for this type of technology remains to achieve optimal operation and high roundtrip efficiencies, which has hindered the deployment of previous electrochemical cells. This dissertation demonstrates how reversible protonic ceramic electrochemical cells (RePCECs) can be integrated with fossil fuel power plants and renewable energy sources as a potential energy storage system. In this work, integrated RePCEC systems are designed and examined using computational modeling at scales to determine appropriate system configurations and operating conditions that achieve high roundtrip efficiencies. Cell level design of the PCEC is the first approach, several cells are assembled for the stack level model that is integrated into combined cycle powerplant and solar photovoltaic for the system level model. After critical literature review, this answered the operational and integration research questions proposed to address these challenges. The designed systems perform two functions, utilizing captured CO2 and storing renewable energy through co-electrolysis of steam and CO2. The co-electrolysis reaction involves endothermic water electrolysis and exothermic methanation reaction. To enhance high roundtrip efficiency, there is a need for thermal balance and management in the electrolysis mode. This involves operating the RePCEC stack under conditions that favor methane production to balance out heat needed by water electrolysis, it crucial for the RePCEC system operation. Methanation is enhanced by low temperatures. Leveraging on fabricated BCZYYb-electrolyte RePCEC, the cell model designed revealed that the optimum temperature for methane production is 450℃ at atmospheric pressure. Thus, to achieve optimum system performance, operating in the temperature range 450-525℃ is recommended at the given configuration, combining between the optimum temperature for methane production and temperature for the optimum stack roundtrip efficiency. Configuration with carbon capture system and purge stream is the optimum configuration from the seven conceptualized and evaluated. The modeling outcomes include a thermodynamic examination of integrated RePCEC systems, calibration of cell and stack level models, and steady-state simulation and integration into a 600MW combined cycle power plant retrofitted with two two-stage membrane-based carbon capture system and a wastewater treatment and recovery unit. At 100% powerplant loading, the stack and system roundtrip efficiencies are 72% and 51.37% respectively. Adding a purge stream for produced hydrogen at the system downstream improves the efficiencies to 74 and 55.48% respectively. At atmospheric pressure and 525℃, the system model suggests that a stack roundtrip of 82% is achievable, and overall system efficiency increases by reducing the energy consumption by the balance of plant components for steam generation and storage. Economic analysis of the process gives levelized cost of methane as $2.24/MMBtu lower than the conventional production route that range between $3.46/MMBtu and $9.85/MMBtu. The lifecycle analysis shows that the global warming potential for the production of methane and hydrogen from the RePCEC system is 3.83 kg CO2 eq which is lower than 9.35 kg CO2 eq emission during steam methane reforming for hydrogen production. This answered both the environmental and economic concerns in the raised research question. The proposed RePCEC configuration and analysis carried out in this dissertation to address the surge in renewable energy and challenges with PCEC technology hold significant potential in achieving large-scale energy storage while simultaneously reducing carbon emissions. These advancements, coupled with suitable governmental policies and incentive programs, have the potential to economically disrupt the natural gas industries by using RePCEC systems for methane production, thereby making them more favorable for eventual implementation and commercialization.

25 ENERGY STORAGE↗

Multi-Constituent Airborne Contaminants Capture with Low Cost Oxide Getters and Mitigation of Cathode Poisoning in Solid Oxide Fuel Cell

The technical effort and scientific findings, discussed in this report, documents operational barriers and associated long term performance stability challenges posed by the presence of trace airborne multi-constituent contaminants present in high-temperature electrochemical systems, including Solid Oxide Fuel Cells (SOFCs), Solid Oxide Electrolysis Cells (SOECs), Ion Transport Membranes, and Gas Separation systems. Above systems, offering promises for cleanliness and energy efficiency, face challenges with electrode poisoning stemming from the presence of trace contaminants including gaseous Cr/B/Si vapors in the presence of intrinsic contaminants SO 2 /CO 2 /H 2 O gases. The study indicates that the long-term electrical performance degradation in SOFC systems can be traced to electrochemical, structural, and mechanical changes across cell, stack, and balance of plant components resulting from interactions with trace contaminants leading to increase in both ohmic and non-ohmic polarizations. The degradation primarily results from solid-state and gas-phase materials migration, electrode poisoning, and interactions at the cell and stack levels. Cathode degradation emerges as a significant factor impacting overall SOFC performance, especially related to the presence of intrinsic and extrinsic airborne impurities such as SOx, CrOx(OH)y, SOx, Si(OH)x, and HBOx. Although at trace levels, prolong systems operation at higher airflow (3-10X stoichiometric) allow the accumulation of contaminants within the cell components leading to electrical performance degradation through poisoning and electrode deactivation.

20 FOSSIL-FUELED POWER PLANTS↗