Electron- and light-induced stimulated Raman spectroscopy for nanoscale molecular mapping

We propose and theoretically analyze a new vibrational spectroscopy, termed electron- and light-induced stimulated Raman (ELISR) scattering, that combines the high spatial resolution of elec-tron microscopy with the molecular sensitivity of surface-enhanced Raman spectroscopy. WithELISR, electron-beam excitation of plasmonic nanoparticles is utilized as a spectrally-broadband butspatially-confined Stokes beam in the presence of a diffraction-limited pump laser. To characterizethis technique, we develop a numerical model and conduct full-field electromagnetic simulations toinvestigate two distinct nanoparticle geometries, nanorods and nanospheres, coated with a Raman-active material. Our results show the significant (10 6 -10 7 ) stimulated Raman enhancement that isachieved with dual electron and optical excitation of thesenanoparticle geometries. Importantly,the spatial resolution of this vibrational spectroscopy for electron microscopy is solely determinedby the nanoparticle geometry and the plasmon mode volume. Our results highlight the promiseof ELISR for simultaneous high-resolution electron microscopy with sub-diffraction-limited Ramanspectroscopy, complementing advances in superresolutionmicroscopy, correlated light and electronmicroscopy, and vibrational electron energy loss spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Electron Spectro-Microscopy (ESM) Beamline at NSLS-II

Photoelectron spectroscopy is a primary tool for the study of the electronic structure of materials and the chemical composition of surfaces. High-resolution angle-resolved photoemission spectroscopy (ARPES) has the unique ability to map the energy bands in momentum space. Furthermore, going beyond the single particle picture, the self-energy corrections caused by correlations in solids can be extracted from the analysis of the emission line shape. The current level of refinement, in terms of energy and angular resolution (ΔE < 1 meV, Δθ < 0.1°), makes the technique sensitive to the lowest energy excitations and the dynamics of electrons, which in turn virtually determine all the macroscopic properties of any system and govern the chemical, electrical, magnetic, and physical processes. Similarly important, X-ray photoelectron microscopy (XPEEM), combined with the low-energy electron microscopy (LEEM), is indispensable in probing the complexity of chemical, structural, electronic and magnetic properties of surfaces and shallow interfaces, with the spatial resolution of few tens of nanometer (nm). The Electron-Spectro-Microscopy beamline (ESM) has been recently commissioned at NSLS-II and is now in operation. The primary spectroscopic technique is photoemission, performed over a wide energy range with control of light polarization and in a variety of flux/resolution conditions. The beamline has two experimental end stations that allow to perform ARPES and XPEEM/LEEM, separately. The ARPES end station focuses on high energy-resolution work, with spot-size of a few microns. The XPEEM/LEEM end station is a full-field microscope (XPEEM) operating either with the synchrotron generated X-rays (XPEEM), or with an internal electron gun (LEEM). Spatial resolution is crucial in studies of newly synthesized complex materials since they are often initially available only as small specimens (typically micron size). Furthermore, chemical inhomogeneities on surfaces are often an integral part of surface chemical processes. Finally, the ESM beamline with X-ray spots of few microns is optimized to study the electronic structure of novel materials with microscopy capabilities.

47 OTHER INSTRUMENTATION↗

Chapter 4: Physically informed deep learning networks for simulating microstructure evolution of 3D polycrystals

As discussed in the previous chapter, high energy diffraction microscopy (HEDM) is used to study the micromechanical evolution of a material during in situ loading. HEDM experiments have been used to verify crystal plasticity (CP) simulations [119, 91, 90, 120], for experimental planning, material design, and to further analyze experimental results. However, Fast Fourier transform-based CP (CP-FFT) or finite element-based CP (CP-FE) methods are often too slow to be used in real-time during an experiment. CP-FFT is faster than CP-FE simulations due to the absence of meshing, but can still take hours to simulate the response of a single volume depending on the size and number of strain steps [127]. Reducing computation time would create a larger exploration space in planning and design, and enable faster analysis of experimental results and real-time feedback during an experiment. This research expands upon previous works to develop a workflow for predicting the full-field evolution of a 3D polycrystal. The workflow is simplified from previous works to predict only orientation and elastic strain tensors (from which stress tensors are calculated). The network is physically informed through loss functions and network architecture for a more robust model. The orientation predictions are informed about the cubic crystal symmetry of the material by incorporating disorientation and misorientation information into the network architecture and loss. The Von Mises stress is used to enforce the correct stress-strain trends in the strain tensor predictions. Additional total strain steps from the elastic and elastoplastic region are included to better capture the stress-strain evolution at smaller total strain steps. Material and hardening parameters are additional inputs into the networks to further inform the network and to study the network’s ability to predict different materials other than those used for training.

36 MATERIALS SCIENCE↗

Solute effects upon dislocation motion and recovery in Mg alloys (Final Report)

The objective the research was to develop a firmer understanding of the interactions between substitutional solute atoms and dislocations within Mg alloys. These interactions govern the absolute and relative mobilities of various types of dislocations in Mg (e.g., basal < a>, non-basal < a>, and pyramidal < c+a>). Furthermore, they have an impact on dislocation recovery processes (e.g., cross-glide, climb, rearrangement, and annihilation). Ultimately, solute-dislocation interactions strongly impact a) strain hardening, b) strain rate sensitivity, c) plastic anisotropy of textured polycrystals, d) texture evolution, e) dislocation substructures evolution, and even f) recrystallization behavior. It is broadly known that Mg alloys exhibit poor low temperature formability. Since formability is largely governed by properties (a) – (c) in this list, it is critical to develop a better understanding of solute-dislocation interactions, if one hopes to improve the situation. While the theory of static solute strengthening is well developed, especially for alloys with face centered cubic (FCC) crystal structures, there are outstanding questions related to applications to hexagonal close packed (HCP) crystal structures and dynamic strain aging (DSA) in materials of various structures. DSA has far-reaching implications for metal formability and, in the case of Mg alloys, appears to correlate with the so-called rare-earth (RE) texture which has been shown to benefit formability. The Portevin-Le Chatelier (PLC) effect, and associated negative strain rate sensitivity, occur at higher temperatures (>100℃) in Mg alloys as compared with similar Al alloys, even though they have similar melting points and solute diffusivities. Our preliminary research has shown that modern, physics-based models of DSA can be tuned to describe the behavior of Mg alloys if a rather higher activation enthalpy is assumed for cross-core diffusivity. While this partially explains the delay in DSA to higher temperatures, it is also hypothesized that this delay is due in part to the intrinsically more thermally activated (rate sensitive) nature of non-basal < a> dislocation motion which is required for macroscopic flow of Mg alloys, whereas octahedral slip in many FCC metals like aluminum is essentially athermal at room temperature. It was originally proposed to employ a combination of in-situ diffraction-based experimental characterization to validate existing theory. It was envisioned to perform in-situ transmission electron microscopy (TEM) to assess individual dislocation behavior and in-situ high-energy X-ray diffraction (HEXRD) techniques which were showing great promise for elucidating collective dislocation behavior, 2 including recovery, especially if the contributions to various forms of diffraction peak broadening (𝜂𝜂,𝜔𝜔,and 2𝜃𝜃) can be effectively integrated. Finally, it was envisioned to perform discrete dislocation dynamics (DDD) modeling approaches to aide in the interpretation of both TEM and HEXRD experiments. In the end, mechanical tests were performed on more complex Mg alloys which exhibited evidence of dynamic strain aging, and this led to the establishment of another project. Mechanical test data obtained at McMaster University served as the basis of an assessment of the applicability of Bazinski’s “stress equivalence” theory of solute strengthening to polycrystalline alloys of Mg. Although we did not succeed in applying the approach to Mg alloys, we did develop expertise with the HEXRD approach using a BCC, β-Ti alloy and demonstrated numerous new capabilities that may be applied to any polycrystalline material in collaboration with researchers at CHESS and around the world: (1) assessment of details of the elastoplastic transition (yielding) using a combination of HEXRD and full-field polycrystal plasticity modeling, (2) the first-ever experimental observation of strong stress rotation within the individual grains of a polycrystalline material, and (3) a comprehensive analysis of the grain-level dislocation density evolution based upon diffraction peak broadening along 𝜂𝜂,𝜔𝜔,and 2𝜃𝜃 directions. This final aspect allowed us to confirm that dislocations were gliding on multiple plane types and not restricted to {110} type planes, and it also provided clues as to why some grains were unloading during straining, with surprising implications for our understanding of the effects of geometrically necessary dislocations (GNDs). Finally, graduate student, Mohammed Shabana, developed a MATLAB code which confirmed the conclusions of Prof. Catalin Picu (Rensallear Polytechnic Institute, RPI) regarding the effect of solute-trapped, forest dislocations on the breaking stress of Lomer lock junctions in FCC metal alloys. He applied the same anisotropic line-tension model to a variety of dislocation junction configurations and found an inconsistency in the widely cited results of Dupuy and Fivel regarding the Hirth Lock, and he outlined an approach to extend these finding to HCP Mg alloys that we are still pursuing with discretionary fundings at UVA.

36 MATERIALS SCIENCE↗

Microstructure Clones

Background: A material’s microstructure drives its material performance. Contemporary crystal plasticity experiments compare full-field strain measurements of polycrystal specimens to models. Because each specimen is unique, it is impossible to know which features of the observed deformation are deterministic vs statistical; thus, differences between model and experiment may or may not be significant. Objective: This paper introduces the invention of microstructure clones. Microstructure clones are 2D oligocrystal specimens that have nearly identical microstructures to remedy the aforementioned experimental limitations. Having specimens with nearly identical microstructures will allow for multiple destructive tests of a microstructure (either as repeats or intentionally different experiments), an ability to “see the future” by providing insight into how a specimen will deform, variability quantification, and experimental investigations of response to small microstructural changes. Methods: This work introduces microstructure clones. Repeatability of these clones is demonstrated in tensile bars of pure nickel. Local strain measurements from digital image correlation are compared between clone specimens and compared to results from a crystal plasticity finite element model. Results: Two sets of microstructure clones were tested in this study and displayed very consistent deformation responses within each clone set. Small observed differences in deformation invite investigation into microstructure stochasticity and the effect of small microstructural and loading differences. Conclusions: Microstructure clones represent a significant shift in understanding structure–property relationships. This work reshapes experimental crystal plasticity to allow for experiments that control for specific variables, quantification of microstructural stochasticity (and other sources of stochasticity), and opportunities for replicating experiments.

Crystal Plasticity↗

An Internal Digital Image Correlation Technique for High-Strain Rate Dynamic Experiments

Full-field, quantitative visualization techniques, such as digital image correlation (DIC), have unlocked vast opportunities for experimental mechanics. However, DIC has traditionally been a surface measurement technique, and has not been extended to perform measurements on the interior of specimens for dynamic, full-scale laboratory experiments. This limitation restricts the scope of physics which can be investigated through DIC measurements, especially in the context of heterogeneous materials. The focus of this study is to develop a method for performing internal DIC measurements in dynamic experiments. The aim is to demonstrate its feasibility and accuracy across a range of stresses (up to 650 MPa), strain rates (10 3 - 10 6 s -1 ), and high-strain rate loading conditions (e.g., ramped and shock wave loading). Internal DIC is developed based on the concept of applying a speckle pattern at an inner-plane of a transparent specimen. The high-speed imaging configuration is coupled to the traditional dynamic experimental setups, and is focused on the internal speckle pattern. During the experiment, while the sample deforms dynamically, in-plane, two-dimensional deformations are measured via correlation of the internal speckle pattern. In this study, the viability and accuracy of the internal DIC technique is demonstrated for split-Hopkinson (Kolsky) pressure bar (SHPB) and plate impact experiments. The internal DIC experimental technique is successfully demonstrated in both the SHPB and plate impact experiments. In the SHPB setting, the accuracy of the technique is excellent throughout the deformation regime, with measurement noise of approximately 0.2% strain. In the case of plate impact experiments, the technique performs well, with error and measurement noise of 1% strain. The internal DIC technique has been developed and demonstrated to work well for full-scale dynamic high-strain rate and shock laboratory experiments, and the accuracy is quantified. Here, the technique can aid in investigating the physics and mechanics of the dynamic behavior of materials, including local deformation fields around dynamically loaded material heterogeneities.

36 MATERIALS SCIENCE↗

A large field-of-view high-resolution hard x-ray microscope using polymer optics

Here, we present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field X-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross-section is used for uniformly illuminating samples over a large field of view (FoV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wave-front distortions. Using a specific lens-pair designed for 20 keV X-rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FoV, 80 × 80 µm 2 in extent. The results were contrasted with those collected under illumination using commercial two-dimensional parabolic lenses with a smaller FoV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of ‘mesoscopic’ phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.

47 OTHER INSTRUMENTATION↗

Near-field imaging of optical resonances in silicon metasurfaces using photoelectron microscopy

Precise control of light–matter interactions at the nanoscale lies at the heart of nanophotonics. However, experimental examination at this length scale is challenging since the corresponding electromagnetic near-field is often confined within volumes below the resolution of conventional optical microscopy. In semiconductor nanophotonics, electromagnetic fields are further restricted within the confines of individual subwavelength resonators, limiting access to critical light–matter interactions in these structures. In this work, we demonstrate that photoelectron emission microscopy (PEEM) can be used for polarization-resolved near-field spectroscopy and imaging of electromagnetic resonances supported by broken-symmetry silicon metasurfaces. We find that the photoemission results, enabled through an in situ potassium surface layer, are consistent with full-wave simulations and far-field reflectance measurements across visible and near-infrared wavelengths. In addition, we uncover a polarization-dependent evolution of collective resonances near the metasurface array edge taking advantage of the far-field excitation and full-field imaging of PEEM. Here, we deduce that coupling between eight resonators or more establishes the collective excitations of this metasurface. All told, we demonstrate that the high-spatial resolution hyperspectral imaging and far-field illumination of PEEM can be leveraged for the metrology of collective, non-local, optical resonances in semiconductor nanophotonic structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct detection system for full-field nanoscale X-ray diffraction-contrast imaging

Recent developments in X-ray science provide methods to probe deeply embedded mesoscale grain structures and spatially resolve them using dark field X-ray microscopy (DFXM). Extending this technique to investigate weak diffraction signals such as magnetic systems, quantum materials and thin films prove challenging due to available detection methods and incident X-ray flux at the sample. We present a direct detection method developed in conjunction with KAImaging which focuses on DFXM studies in the hard X-ray range of 10s of keV and above capable of approaching nanoscale resolution. Additionally, we compare this direct detection scheme with routinely used scintillator-based optical detection and achieve an order of magnitude improvement in exposure times allowing for imaging of weakly diffracting ordered systems.

47 OTHER INSTRUMENTATION↗

Stereo Imaging Velocimetry Technique Using Standard Off-the-Shelf CCD Cameras

Stereo imaging velocimetry is a fluid physics technique for measuring three-dimensional (3D) velocities at a plurality of points. This technique provides full-field 3D analysis of any optically clear fluid or gas experiment seeded with tracer particles. Unlike current 3D particle imaging velocimetry systems that rely primarily on laser-based systems, stereo imaging velocimetry uses standard off-the-shelf charge-coupled device (CCD) cameras to provide accurate and reproducible 3D velocity profiles for experiments that require 3D analysis. Using two cameras aligned orthogonally, we present a closed mathematical solution resulting in an accurate 3D approximation of the observation volume. The stereo imaging velocimetry technique is divided into four phases: 3D camera calibration, particle overlap decomposition, particle tracking, and stereo matching. Each phase is explained in detail. In addition to being utilized for space shuttle experiments, stereo imaging velocimetry has been applied to the fields of fluid physics, bioscience, and colloidal microscopy.

McDowell, Mark↗