Search NASA⌕ Search

SEARCH · Search NASA

Results for “Functional Fault”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development and performance of high-temperature superconducting CORC ® cables with CFD REBCO tapes

Abstract Increasing the normal zone propagation velocity (NZPV) in superconducting cables based on rare earth barium copper oxide (REBCO) tapes is expected to cause a paradigm shift by enabling the development of faster and more reliable quench detection systems to mitigate the development of destructive hot spots. Furthermore, a higher NZPV is beneficial in terms of fault current limitation capabilities by accelerating the homogenization of the quench in superconducting power devices. One way envisioned to increase the NZPV of cables based on REBCO tapes is the current flow diverter (CFD) concept. A Conductor on Round Core (CORC ® ) cable made with CFD REBCO tapes, called CFD CORC ® cable, and a CORC ® cable made with regular REBCO tapes, were fabricated and tested. The critical current of the CFD and regular CORC ® cables were obtained at temperatures ranging from 67 to 77 K in self-field. Measurements showed that the NZPV was increased by a factor of 4–4.5 in the case of the CFD CORC ® cable. Furthermore, the results suggest that the NZPV depends only on the applied current, similar to what has been observed previously on single REBCO tapes. These results demonstrate the successful integration of CFD REBCO tapes in CORC ® cables, without compromising their superconducting properties or their enhanced NZPV. The possibility of enhancing the NZPV of REBCO-based cables could facilitate quench detection, which remains an important issue in HTS magnet applications. This advancement also holds promise for the fault current limitation functionality of CORC ® cables.

Ben Saâd, Haïfa (ORCID:0000000216205364)↗

Fault isolation and fault-tolerant control for nonlinear stochastic distribution control systems with multiplicative faults

Here, in this paper, a fault isolation, diagnosis and fault tolerant control algorithm is proposed for nonlinear multiple multiplicative faults stochastic distribution control systems employing Takagi–Sugeno fuzzy system. To obtain the detailed fault information, a fault detection algorithm is introduced to discover the fault occurrence time. Then a fault isolation observer is built to produce the residual, and the error system is separated to subsystems affected only by disturbance and multiplicative faults. Moreover, a fault estimation scheme is presented to obtain the fault magnitude information. When faults occur, the system output probability density function will deviate from the desired distribution. So the model predictive control fault tolerant control scheme is needed to minimize the impact of faults as much as possible to make sure that the post fault output probability density function track the desired probability density function. The validity of the designed algorithm is demonstrated through a simulation example, where the fault tolerant control algorithm ensures that the system output probability density function still track the given output probability density function despite the complex case of multiple multiplicative faults occurring simultaneously.

42 ENGINEERING↗

Model Predictive Fault-Tolerant Tracking Control for PDF Control Systems With Packet Losses

In this article, a fault-tolerant tracking control strategy is investigated for nonlinear probability density function (PDF) control systems with the actuator fault, uncertainties, unknown disturbance, and random packet losses. The control input signal dropout and measurement signal dropouts are described as the independent Bernoulli distribution. An adaptive fault diagnosis (FD) observer based on the Lyapunov function is given to simultaneously estimate the fault, disturbance, and state with packet losses. Furthermore, different from the traditional robust fault-tolerant control (FTC), a new active fault-tolerant tracking controller is designed based on the model predictive control framework, which has better adaptive fault-tolerant performance. Finally, the validity of the proposed FTC method has been proved by a simulation study of a papermaking process.

42 ENGINEERING↗

Real-Time Model-Adaptive Relaying Applied to Microgrid Protection

In microgrids, the short-circuit current magnitude is significantly limited by more than an order of magnitude due to the relatively small inverter-based resources. Commercially available protective devices for distribution cannot reliably protect a microgrid due to their dependence on the magnitude of the fault current. Moreover, overcurrent relays typically cannot function properly for a microgrid because they are incapable of detecting faults and/or performing the coordination between the relays in inverter-based microgrids operated in the islanded mode. This paper proposes a model-adaptive relay designed to adjust the relay curves based on the available generation and the network topology. The proposed method runs a real-time model of the microgrid, which gathers information from the network to calculate the available short-circuit current in the specified node. The fault current from the model is then used for the adaptive algorithm to calculate the relay settings, considering coordination with the downstream fuses and upstream reclosers. This work presents the validation of the proposed method in Hardware-in-the-Loop, in a hardware testbed as well as field deployed in a real microgrid in East-Tennessee.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Origin of giant electric-field-induced strain in faulted alkali niobate films

A large electromechanical response in ferroelectrics is highly desirable for developing high-performance sensors and actuators. Enhanced electromechanical coupling in ferroelectrics is usually obtained at morphotropic phase boundaries requiring stoichiometric control of complex compositions. Recently it was shown that giant piezoelectricity can be obtained in films with nanopillar structures. Here, we elucidate its origin in terms of atomic structure and demonstrate a different system with a greatly enhanced response. This is in non-stoichiometric potassium sodium niobate epitaxial thin films with a high density of self-assembled planar faults. A giant piezoelectric coefficient of ~1900 picometer per volt is demonstrated at 1 kHz, which is almost double the highest ever reported effective piezoelectric response in any existing thin films. The large oxygen octahedral distortions and the coupling between the structural distortion and polarization orientation mediated by charge redistribution at the planar faults enable the giant electric-field-induced strain. Our findings demonstrate an important mechanism for realizing the unprecedentedly giant electromechanical coupling and can be extended to many other material functions by engineering lattice faults in non-stoichiometric compositions.

36 MATERIALS SCIENCE↗

Probing the Damage Zone at Parkfield

Rocks are heterogeneous materials that exhibit nonlinear elastic (anelastic) behavior at scales ranging from the laboratory to Earth. In the laboratory, typical, complex relationships exist between stress and strain that include hysteresis, finite relaxation times, strain rate, and history dependence. These behaviors are linked to important characteristics such as stress, porosity, permeability, material integrity, and material failure. In this work, we adopted a “pump-probe” type experiment common in laboratory studies, using solid earth tides as the low-frequency pump and empirical Green's function as the high-frequency probe. By probing the velocity at different points in the pump cycle, we constrained important information about the strain-modulus relationship. Near the San Andreas Fault, we observed strongly nonlinear elastic behavior that characterizes the damage zone. We also constrained important aspects of hysteretic behavior that are related to damage properties and possibly pore pressure. Away from the fault, the nonlinear behavior is diminished.

58 GEOSCIENCES↗

Fault location in High Voltage Multi-terminal dc Networks Using Ensemble Learning

Precise location of faults for large distance power transmission networks is essential for faster repair and restoration process. High Voltage direct current (HVdc) networks using modular multi-level converter (MMC) technology has found its prominence for interconnected multi-terminal networks. This allows for large distance bulk power transmission at lower costs. However, they cope with the challenge of dc faults. Fast and efficient methods to isolate the network under dc faults have been widely studied and investigated. After successful isolation, it is essential to precisely locate the fault. The post-fault voltage and current signatures are a function of multiple factors and thus accurately locating faults on a multi-terminal network is challenging. In this paper, we discuss a novel data-driven ensemble learning based approach for accurate fault location. Here we utilize the eXtreme Gradient Boosting (XGB) method for accurate fault location. The sensitivity of the proposed algorithm to measurement noise, fault location, resistance and current limiting inductance are performed on a radial three-terminal MTdc network designed in Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Capabilities of multivariate Bayesian inference toward seismic hazard assessment

Multivariate Bayesian analysis can bring significant benefits to seismic hazard analysis: Its multivariate feature enables computing scalar and vector hazard without making any approximations; Correlations between intensity measures are implicitly modeled, permitting direct simulation of ground motion selection tools such as the conditional mean spectrum and the generalized conditioning intensity measure; and Its updating feature enables a seamless integration of new ground motion data into the hazard results. Here, we first develop a multivariate Bayesian ground motion model through the NGA-West2 database. The model functional form considers fault-type, magnitude, and distance dependencies, and also the linear and the rock intensity dependent site response. We use a hybrid Markov Chain Monte Carlo sampling to perform Bayesian inference consisting of Gibbs step and a multilevel Metropolis-Hastings step. We then perform several checks on the model and note that its performance is satisfactory. Finally, we illustrate the merits of this multivariate Bayesian analysis, which include: ground motion model updating with ground motion data recorded in the last four years not part of the NGA-West2 database; computation of scalar and vector seismic hazard using the un-updated and updated ground motion models for Los Angeles, CA; and simulation of the conditional mean spectrum under scalar and vector IM conditioning while accounting for different sources of aleatoric and epistemic uncertainties.

58 GEOSCIENCES↗

Strain-driven oxygen vacancy ordering in LaNiO 3 thin films revealed by integrated differential phase contrast imaging in scanning transmission electron microscopy

Rare-earth nickelates, such as LaNiO 3 (LNO), exhibit complex electronic properties, with ordered oxygen vacancies (OOV) influencing conductivity and magnetic behavior. We investigate the structural stability of strain-induced OOV phases in LNO thin films grown on SrTiO 3 substrates and the impact of Ruddlesden–Popper (RP) faults. Using high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) and integrated differential phase contrast (iDPC) STEM imaging, we conducted atomic-scale structural and compositional analyses of OOV. Geometric phase analysis (GPA) was employed to measure the strain in fault-free and RP fault regions, while density functional theory (DFT) calculations explored different OOV arrangements in the LNO phase. Simulated iDPC-STEM imaging of energy-stabilized structures was performed to correlate with experimental results. Here, our findings reveal superstructure modulation in the chemical composition and atomic-scale lattice structure in LNO, primarily due to the formation of the OOV in Ni–O layers of the LaNiO 2.5 phase. The out-of-plane compressive strain of about 2% stabilizes this phase, reducing the strain, diminishing OOV, and transforming them into LNO.

36 MATERIALS SCIENCE↗

Development of a Scalable Risk-informed Predictive Maintenance Cloud-based Strategy at Nuclear Power Plants

The fact that light-water reactor operation and maintenance costs are prohibitively expensive and contribute to the premature decommissioning of nuclear power plants is partly due to how the equipment is monitored. In recent years, cloud computing has emerged as a dominant technology, as its low cost, computing and storage adaptability, and ability to host applications across numerous virtual infrastructures potentially make it a cost-effective alternative to onsite storage and diagnostics. In this paper, a technological assessment is carried out on a provisional cloud deployment architecture for a nuclear power plant predictive monitoring system. This cloud-based monitoring system would enable maintenance and diagnostic analysts and other authorized plant users to remotely monitor equipment functionality, thus enabling early fault detection and effective predictive maintenance practices. To provide data processing and storage, sensor device networking, and database management, the Microsoft Azure cloud platform is utilized as part of the proposed cloud architecture; however, this analysis could be extended to other cloud computing service providers as well. The focus of this paper is on application of cloud resources for enabling predictive maintenance, identification of technological hurdles associated with moving to a cloud-computing-based architecture, and potential benefits from moving to a centralized cloud system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pinning dislocations in colloidal crystals with active particles that seek stacking faults

There is growing interest in functional, adaptive devices built from colloidal subunits of micron size or smaller. A colloidal material with dynamic mechanical properties could facilitate such microrobotic machines. Here we study via computer simulation how active interstitial particles in small quantities can be used to modify the bulk mechanical properties of a colloidal crystal. Passive interstitial particles are known to pin dislocations in metals, thereby increasing resistance to plastic deformation. We extend this tactic by employing anisotropic active interstitials that travel super-diffusively and bind strongly to stacking faults associated with partial dislocations. We find that: (1) interstitials that are effective at reducing plasticity compromise between strong binding to stacking faults and high mobility in the crystal bulk. (2) Reorientation of active interstitials in the crystal depends upon rotational transitions between high-symmetry crystal directions. (3) The addition of certain active interstitial shapes at concentrations as low as 60 per million host particles (0.006%) can create a shear threshold for dislocation migration. This work demonstrates how active materials in a dense matrix can locally sense their environment and lead to bulk property changes.

36 MATERIALS SCIENCE↗

High Impedance Fault Detection Through Quasi-Static State Estimation: A Parameter Error Modeling Approach

This paper presents a model for detecting high impedance faults using parameter error modeling and a two step per-phase weighted-least squares state estimation process. The proposed scheme leverages the use of Phasor Measurement Units and synthetic measurements to identify per-phase power flow and injection measurements which indicate a parameter error through ?2 Hypothesis Testing applied to the composed measurement error. Although current and voltage waveforms are commonly analyzed for high-impedance fault detection, wide area power flow and injection measurements, which are already inherent to the state estimation process, also show promise for real-world high-impedance fault detection applications. The error distributions after detection share the measurement function error spread observed in proven parameter error diagnostics and can be applied to high-impedance fault identification. Further, this error spread across measurement functions related to the fault will be clearly discerned from measurement error. Case studies are performed on the IEEE 33-Bus Distribution System along with the proposed model in Simulink.

Cooper, Austin↗

Stacking Fault Induced Symmetry Breaking in van der Waals Nanowires

While traditional ferroelectrics are based on polar crystals in bulk or thin film form, two-dimensional and layered materials can support mechanisms for symmetry breaking between centrosymmetric building blocks, e.g., by creating low-symmetry interfaces in van der Waals stacks. Here, we introduce an approach toward symmetry breaking in van der Waals crystals that relies on the spontaneous incorporation of stacking faults in a nonpolar bulk layer sequence. The concept is realized in nanowires consisting of Se-rich group IV monochalcogenide (GeSe 1–x S x ) alloys, obtained by vapor–liquid–solid growth. The single crystalline wires adopt a layered structure in which the nonpolar A-B bulk stacking along the nanowire axis is interrupted by single-layer stacking faults with local A-A' stacking. Density functional theory explains this behavior by a reduced stacking fault formation energy in GeSe (or Se-rich GeSe 1–x S x alloys). Computations demonstrate that, similar to monochalcogenide monolayers, the inserted A-layers should show a spontaneous electric polarization with a switching barrier consistent with a Curie temperature above room temperature. Second-harmonic generation signals are consistent with a variable density of stacking faults along the wires. Here, our results point to possible routes for designing ferroelectrics via the layer stacking in van der Waals crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geomechanical in situ testing of fault reactivation in argillite repositories

Abstract. Pressurization of natural faults as a result of repository-induced effects can lead to their reactivation and permeability generation in case such features are present near disposal tunnels. Potential driving forces for such pressurization are the temperature increase caused by heat-producing high-level radioactive waste and the generation of hydrogen and other gases due to corrosion of engineered materials. We are primarily concerned about pressurization and fault activation in host rocks and faults that have very low natural permeability for pore pressure increases to dissipate, such as the argillite rocks currently investigated in Switzerland, France and other countries. This presentation discusses a series of in situ experiments of fault activation by fluid injection conducted in the argillite rock (Opalinus clay) at the Mont Terri underground research laboratory in Switzerland. A multi-model monitoring test bed was installed at Mont Terri that includes distributed fiber optics for strain, temperature, and acoustics; local fault pore pressure and three-dimensional displacement sensors; active seismic imaging; and passive seismic monitoring. The fault experiments (and their subsequent analysis via hydromechanical modeling) provide a new fundamental understanding of the coupling between pore pressure, fault deformation and permeability generation as a function of time and allow exploring how seismic and aseismic events may impact the integrity of faulted argillite host rock. Our experimental observations demonstrate that significant flow (and transport) can occur along the initially impermeable argillite fault when rupture is activated. However, the fault permeability decreases to almost its pre-activation value when fluid injection ceases and fluid pressure drops. Dilatant slip on the fault plane alone does not explain the observed increase in fault permeability; pressure-induced fault opening also plays a role, favored by the softness of the shale along with the fact that the structure of the fault zone prevents fluids from diffusing into the adjacent damage zone. Rupture initiation and permeability generation is initially aseismic, associated only with an increase in noise level and emerging tremors. Micro-earthquakes are initiated later in the experiments and typically occur away from the fluid-pressurized area. Hydromechanical models show that stress transferred from the initial aseismic deformation can build up to stress criticality and later induce seismic rupture. After presenting the experimental results, we will close the presentation with an outlook to future experimental campaigns using the fault test bed at Mont Terri. We are currently planning a controlled thermal stimulation of the fault, where instead of fluid injection as a trigger mechanism we will heat up the nearby rock volume and measure potential effects on fault stability. Lessons learned from our past and future experiments will help inform the safety assessment of geologic disposal in argillite host rock.

Birkholzer, Jens T.↗

Maximizing Efficiency and Quality: Leveraging Automated Testing for Laboratory Commissioning

The traditional commissioning process uses sampling to select equipment for functional acceptance testing when large quantities of equipment are present. Although this approach is generally effective in identifying wide-spread issues, it has several shortcomings: it fails to evaluate equipment not included in the sample, provides only a one-time validation of equipment operation, and the standard documentation is a simple checklist of pass/fail questions. During the construction and commissioning process of the new Research and Innovation Laboratory (RAIL) in Golden, CO, the National Renewable Energy Laboratory team engaged Group14 Engineering to implement a Connected Commissioning process using fault detection and diagnostic software for automated functional acceptance testing. This presentation highlights the advantages offered by automated functional testing in this critical laboratory setting: (1) sampling 100% of BAS-connected equipment during functional testing, (2) testing results backed by data beyond the traditional pass/fail checklist, and (3) an automated test process that can be regularly executed by the building management team for ongoing commissioning throughout the life of the building. The presentation will also cover technical challenges associated with Connected Commissioning and the important conversations with key stakeholders that need to occur well before functional acceptance testing in order to successfully implement the automated testing processes.

automated testing↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration: Preprint

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗