Development of Compact Gamma Camera for Detection of Prostate Carcinoma

BNL and Hybridyne will jointly develop a compact gamma camera capable of localizing cancerous tumors within the prostate gland. The new gamma-ray camera will consist of a pixilated cadmium-zinc-telluride (CZT) detector array, which would be flip-chip bonded to a suitable substrate. Application specific integrated circuits would also be developed to read out the electronic signals from the pixels, and the detector/ASIC would be integrated into a small probe capable of imaging shaped radioactive phantoms to simulate the detection of cancerous tumors within the prostate gland.

99 GENERAL AND MISCELLANEOUS↗

Optimization of a parallel hole collimator/CdZnTe gamma-camera architecture for scintimammography

Purpose: Small field-of-view CdZnTe (CZT) gamma cameras are increasingly studied for breast lesion detection to complement mammography or ultrasonographic findings. However, in classical collimation configurations, they remain limited by the trade-off between spatial resolution and sensitivity. The HiSens architecture was proposed to overcome these limitations. Using an accurate 3D localization of the interactions inside the detector, this architecture leads to a gain in sensitivity without loss in spatial resolution. In this article, the relevance of the HiSens architecture for planar scintimammography is studied. Methods: A detective quantum efficiency (DQE) computation method is developed and used to optimize the dimensioning of a parallel hole collimator dedicated to scintimammography. Based on the DQE curves, the impact of the collimator-to-detector distance is studied. Two algorithms are proposed to combine data acquired with different collimator-to-detector distances. Results: It is shown that CZT detector virtual pixelization increases system sensitivity by 3.3 while preserving a standard LEHR spatial resolution. The introduction of a gap between the CZT detector and the collimator is useful to modulate the DQE curve shape. The combination of data acquired using different gaps in the image formation process leads to enhanced restoration of the frequency content of the images, resulting in image contrast and spatial resolution improvements. Conclusions: Acquisition duration or injected activity could be markedly reduced if the HiSens architecture with an appropriate collimator-detector gap were used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DRAGO gamma camera

In this work, we present the results of the experimental characterization of the DRAGO (DRift detector Array-based Gamma camera for Oncology), a detection system developed for high-spatial resolution gamma-ray imaging. This camera is based on a monolithic array of 77 silicon drift detectors (SDDs), with a total active area of 6.7 cm{sup 2}, coupled to a single 5-mm-thick CsI(Tl) scintillator crystal. The use of an array of SDDs provides a high quantum efficiency for the detection of the scintillation light together with a very low electronics noise. A very compact detection module based on the use of integrated readout circuits was developed. The performances achieved in gamma-ray imaging using this camera are reported here. When imaging a 0.2 mm collimated {sup 57}Co source (122 keV) over different points of the active area, a spatial resolution ranging from 0.25 to 0.5 mm was measured. The depth-of-interaction capability of the detector, thanks to the use of a Maximum Likelihood reconstruction algorithm, was also investigated by imaging a collimated beam tilted to an angle of 45 deg. with respect to the scintillator surface. Finally, the imager was characterized with in vivo measurements on mice, in a real preclinical environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging performance comparison between a LaBr{sub 3}:Ce scintillator based and a CdTe semiconductor based photon counting compact gamma camera

The authors report on the performance of two small field of view, compact gamma cameras working in single photon counting in planar imaging tests at 122 and 140 keV. The first camera is based on a LaBr{sub 3}:Ce scintillator continuous crystal (49x49x5 mm{sup 3}) assembled with a flat panel multianode photomultiplier tube with parallel readout. The second one belongs to the class of semiconductor hybrid pixel detectors, specifically, a CdTe pixel detector (14x14x1 mm{sup 3}) with 256x256 square pixels and a pitch of 55 {mu}m, read out by a CMOS single photon counting integrated circuit of the Medipix2 series. The scintillation camera was operated with selectable energy window while the CdTe camera was operated with a single low-energy detection threshold of about 20 keV, i.e., without energy discrimination. The detectors were coupled to pinhole or parallel-hole high-resolution collimators. The evaluation of their overall performance in basic imaging tasks is presented through measurements of their detection efficiency, intrinsic spatial resolution, noise, image SNR, and contrast recovery. The scintillation and CdTe cameras showed, respectively, detection efficiencies at 122 keV of 83% and 45%, intrinsic spatial resolutions of 0.9 mm and 75 {mu}m, and total background noises of 40.5 and 1.6 cps. Imaging tests with high-resolution parallel-hole and pinhole collimators are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

A novel method to evaluate gamma camera rotational uniformity and sensitivity variation

An alternative to the conventional method of performing the AAPM Report 52 rotational uniformity and sensitivity test has been developed. In contrast to the conventional method in which a Co-57 sheet source is fastened to the collimator, this new point-source method acquires the images intrinsically using a Tc-99m point source placed near the isocenter of gantry rotation. As with the conventional method, the point-source method acquires 5x10{sup 6} count flood images at four distinct gantry positions to calculate the maximum sensitivity variation (MSV)--a quantitative metric of rotational uniformity and sensitivity variation. The point-source method incorporates corrections for the decay of Tc-99m between acquisitions, the curvature in the image intensity due to variation in photon flux across the detector from a near-field source, and the source-to-detector distance variations between views. The raw point-source images were fitted with an analytic function in order to compute curvature- and distance-corrected images prior to analysis. Five independent MSV measurements were performed using both conventional and point-source methods on a single detector of a dual-headed SPECT system to estimate the precision of each method. The precision of the point-source method was further investigated by performing ten independent measurements of MSV on six different detectors. Correlation between the MSV calculated by the two methods was investigated by performing the test on nine different detectors using both methods. Different levels of sensitivity variations were also simulated on four detectors to generate 40 additional paired points for correlation analysis. The effect of the total image counts on the MSV estimated with the new method was evaluated by acquiring image sequences with 5x10{sup 6}, 10x10{sup 6}, and 20x10{sup 6} count images. The MSV calculated using the conventional and point-source methods exhibited a high degree of correlation and consistency with equivalence. The precision of the point-source method (0.145%) is lower than the conventional method (0.04%) but sufficient to test MSV. No statistically significant dependence of MSV with the point-source method on the total image counts over a range of (5-20)x10{sup 6} counts was observed. Curvature correction of the images prior to the generation of difference images renders images more conducive to qualitative inspection for structured, nonrandom patterns. The advantages of the new methodology are that multiple detectors of a gamma camera can be evaluated simultaneously which substantially reduces the time required for MSV testing and the reduced risk of accidental damage to the collimators and patient proximity detection system from having to mount a sheet source on each of the detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part I. Evaluation in phantoms

Purpose: Molecular breast imaging (MBI) is a nuclear medicine technology that uses dual-head cadmium zinc telluride (CZT) gamma cameras to image functional uptake of a radiotracer, Tc-99m sestamibi, in the breast. An important factor in adoption of MBI in the screening setting is reduction of the necessary administered dose of Tc-99m sestamibi from the typically used dose of 740 MBq to approximately 148 MBq, such that MBI's whole-body effective dose is comparable to that of screening mammography. Methods that increase MBI count sensitivity may allow a proportional reduction in the necessary administered dose. Our objective was to evaluate the impact of two count sensitivity improvement methods on image quality by evaluating count sensitivity, spatial resolution, and lesion contrast in phantom simulations. Methods: Two dual-head CZT-based MBI systems were studied: LumaGem and Discovery NM 750b. Two count sensitivity improvement methods were implemented: registered collimators optimized for dedicated breast imaging and widened energy acceptance window optimized for use with CZT. System sensitivity, spatial resolution, and tumor contrast-to-noise ratio (CNR) were measured comparing standard collimation and energy window setting [126-154 keV (+10%, -10%)] with optimal collimation and a wide energy window [110-154 keV (+10%, -21%)]. Results: Compared to the standard collimator designs and energy windows for these two systems, use of registered optimized collimation and wide energy window increased system sensitivity by a factor of 2.8-3.6. Spatial resolution decreased slightly for both systems with new collimation. At 3 cm from the collimator face, LumaGem's spatial resolution was 4.8 and 5.6 mm with standard and optimized collimation; Discovery NM 750b's spatial resolution was 4.4 and 4.6 mm with standard and optimized collimation, respectively. For both systems, at tumor depths of 1 and 3 cm, use of optimized collimation and wide energy window significantly improved CNR compared to standard settings for tumors 8.0 and 9.2 mm in diameter. At the closer depth of 1 cm, optimized collimation and wide energy window also significantly improved CNR for 5.9 mm tumors on Discovery NM 750b. Conclusions: Registered optimized collimation and wide energy window yield a substantial gain in count sensitivity and measurable gain in CNR, with some loss in spatial resolution compared to the standard collimator designs and energy windows used on these two systems. At low-count densities calculated to represent doses of 148 MBq, this tradeoff results in adequate count density and lesion contrast for detection of lesions {>=}8 mm in the middle of a typical breast (3 cm deep) and lesions {>=}6 mm close to the collimator (1 cm deep).

60 APPLIED LIFE SCIENCES↗

Implementation of test for quality assurance in nuclear medicine gamma camera

In nuclear medicine (NM) over 90% of procedures are performed for diagnostic purposes. To ensure adequate diagnostic quality of images and the optimization of the doses received by patients originated from the radioactive material is essential for regular monitoring and equipment performance through a quality assurance program (QAP). The QAP consists of 15 proposed performance tomographic and not tomographic gamma camera (GC) tests, and is based on recommendations of international organizations. We describe some results of the performance parameters of QAP applied to a GC model e.cam Siemens, of the Department of NM of the National Cancer Institute of Mexico (INCan). The results were: (1) The average intrinsic spatial resolution (R{sub in}) was 4.67 {+-} 0.25 mm at the limit of acceptance criterion of 4.4 mm. (2) The sensitivity extrinsic (S{sub ext}), with maximum variations of 1.8% (less than 2% which is the criterion of acceptance). (3) Rotational Uniformity (U{sub rot}), with values of integral uniformity (IU) in the useful field of view detector (UFOV), with maximum percentage change of 0.97% and monthly variations equal angles, ranging from 0.13 to 0.99% less than 1%. (4) The displacement of the center of rotation (DCOR), indicated a maximum deviation of 0.155 {+-} 0.039 mm less than 4.795 mm, an absolute deviation of less than 0.5 where pixel 0.085 pixel is suggested, the criteria are assigned to low-energy collimator high resolution. (5) In tomographic uniformity (U{sub tomo}), UI values (%) and percentage noise level (rms%) were 7.54 {+-} 1.53 and 4.18 {+-} 1.69 which are consistent with the limits of acceptance of 7.0-12.0% and 3.0-6.0% respectively. The smallest cold sphere has a diameter of 11.4 mm. The implementation of a QAP allows for high quality diagnostic images, optimization of the doses given to patients, a reduction of exposure to occupationally exposed workers (POE, by its Spanish acronym), and generally improves the productivity of the service. This proposal can be used to develop a similar QAP in other facilities and may serve as a precedent for the proposed regulations for quality assurance (QA) teams in MN.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spatially Tracked Hand-held Gamma Camera for Surgery

The goal of the project was to develop and test a 3-dimensional (3D) imaging technology designed to overcome limitations of current non-imaging lymph node mapping methods by integrating a newly developed, unique hand-held gamma camera (HGC) into a platform for freehand SPECT (single photon emission computed tomography). Sentinel lymph node biopsy is a vital component of surgical oncology in the process of establishing the extent of disease and likelihood of metastasis. The team was successful in the development and testing of the device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging system for cardiac planar imaging using a dedicated dual-head gamma camera

A cardiac imaging system employing dual gamma imaging heads co-registered with one another to provide two dynamic simultaneous views of the heart sector of a patient torso. A first gamma imaging head is positioned in a first orientation with respect to the heart sector and a second gamma imaging head is positioned in a second orientation with respect to the heart sector. An adjustment arrangement is capable of adjusting the distance between the separate imaging heads and the angle between the heads. With the angle between the imaging heads set to 180 degrees and operating in a range of 140-159 keV and at a rate of up to 500kHz, the imaging heads are co-registered to produce simultaneous dynamic recording of two stereotactic views of the heart. The use of co-registered imaging heads maximizes the uniformity of detection sensitivity of blood flow in and around the heart over the whole heart volume and minimizes radiation absorption effects. A normalization/image fusion technique is implemented pixel-by-corresponding pixel to increase signal for any cardiac region viewed in two images obtained from the two opposed detector heads for the same time bin. The imaging system is capable of producing enhanced first pass studies, bloodpool studies including planar, gated and non-gated EKG studies, planar EKG perfusion studies, and planar hot spot imaging.

47 OTHER INSTRUMENTATION↗

Modeling an Interwoven Collimator for A 3D Endocavity Gamma Camera

Positron emission tomography (PET) and single-photon emission-computed tomography (SPECT) are important nuclear-medical imaging tools in diagnosing cancers and creating effective treatment plans. Here, commercially imaging systems are operated externally and can create 3D images of the whole body or of specific organs by rotating the gamma-ray detectors, and then employing software to reconstruct the 3D images from the multiple 2D projections at different angles of view.

36 MATERIALS SCIENCE↗

FXR double-pulse gamma camera imaging plans

Presentation describes project to improve radiographic diagnostic capability in the Contained Firing Facility at Site 300 to take full advantage of ongoing improvements to the linac.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy of Measured Activity by the Dual Head Gamma Camera

The subject of research was investigation of the accuracy in determining the {sup 99m}Tc activity injected in a container simulating a single organ. Data acquisition as made with different width and range of energy windows described in the article. The activities of {sup 99m}Tc were determined with an error ranging from 7% to 27%. The most probable source of errors are scattered photons.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Application of Two Phase (Liquid/Gas) Xenon Gamma-Camera for the Detection of Special Nuclear Material and PET Medical Imaging

The McKinsey group at Yale has been awarded a grant from DTRA for the building of a Liquid Xenon Gamma Ray Color Camera (LXe-GRCC), which combines state-of-the-art detection of LXe scintillation light and time projection chamber (TPC) charge readout. The DTRA application requires a movable detector and hence only a single phase (liquid) xenon detector can be considered in this case. We propose to extend the DTRA project to applications that allow a two phase (liquid/gas) xenon TPC. This entails additional (yet minimal) hardware and extension of the research effort funded by DTRA. The two phase detector will have better energy and angular resolution. Such detectors will be useful for PET medical imaging and detection of special nuclear material in stationary applications (e.g. port of entry). The expertise of the UConn group in gas phase TPCs will enhance the capabilities of the Yale group and the synergy between the two groups will be very beneficial for this research project as well as the education and research projects of the two universities. The LXe technology to be used in this project has matured rapidly over the past few years, developed for use in detectors for nuclear physics and astrophysics. This technology may now be applied in a straightforward way to the imaging of gamma rays. According to detailed Monte Carlo simulations recently performed at Yale University, energy resolution of 1% and angular resolution of 3 degrees may be obtained for 1.0 MeV gamma rays, using existing technology. With further research and development, energy resolution of 0.5% and angular resolution of 1.3 degrees will be possible at 1.0 MeV. Because liquid xenon is a high density, high Z material, it is highly efficient for scattering and capturing gamma rays. In addition, this technology scales elegantly to large detector areas, with several square meter apertures possible. The Yale research group is highly experienced in the development and use of noble liquid detectors for astrophysics, most recently in the XENON10 experiment. The existing facilities at Yale are fully adequate for the completion of this project. The facilities of the UConn group at the LNS at Avery Point include a (clean) lab for detector development and this group recently delivered an Optical Readout TPC (O-TPC) for research in Nuclear Astrophysics at the TUNL in Duke University. The machine shop at UConn will be used (free of charge) for producing the extra hardware needed for this project including grids and frames.

07 ISOTOPE AND RADIATION SOURCES↗

Improving quality assurance for assembled COMS eye plaques using a pinhole gamma camera

A quality assurance system has been designed to verify the location and strength of seeds loaded in a brachytherapy eye plaque. This system consists of (1) a pinhole camera in conjunction with a Lumisys ACR-2000i computed radiography (CR) unit to image the location and measure the relative strength of the seeds with autoradiography, and (2) a source strength jig with a survey meter to estimate the total activity of the seeds in the plaque. Five holders of different sizes were made for fixation of the COMS (Collaborative Ocular Melanoma Study) plaques (12, 14, 16, 18, and 20 mm) in the camera. The plaque-to-pinhole distance (d{sub pp}) has been optimized to be 30 mm to give approximately uniform intensity on the CR image for uniformly loaded COMS plaques. The pinhole-to-detector distance (d{sub pd}) can be kept at either 30 mm for 1:1 scale, or at larger distances for higher magnification. For a 1:1 scaling and pinhole diameter of 0.345 mm, useful images are obtained with time-activity product (mCi sec) ranging from 5 to 250 mCi sec. Within this range, the pinhole system is able to differentiate seed activities of >10%. The resulting pinhole autoradiograph is able to (1) confirm the correct number of seeds loaded in the plaque, (2) verify the proper sitting of the seeds in the silastic carrier and the plaque, (3) verify the relative activity distribution of the seeds loaded in the plaque, and (4) potentially evaluate the integrity of the seed. The source strength measurement system is able to measure the total strength of seeds in the plaque ranging from 10 to 80 mCi with an uncertainty of 5%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TestDose: A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry

Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest.com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user’s imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan™ therapeutical treatment was implemented using the 4D XCAT model. Whole-body “step and shoot” acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan™ kinetics, a dosimetry computation performed on the ICRP 110 model is also presented. Conclusions: The proposed platform offers a generic framework to implement any scintigraphic imaging protocols and voxel/organ-based dosimetry computation. Thanks to the modular nature of TestDose, other imaging modalities could be supported in the future such as positron emission tomography.

60 APPLIED LIFE SCIENCES↗