Search NASASearch

SEARCH · Search NASA

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Deviations from the Porter-Thomas Distribution due to Nonstatistical 𝛾 Decay below the 150 Nd Neutron Separation Threshold

We introduce a new method for the study of fluctuations of partial transition widths based on nuclear resonance fluorescence experiments with quasimonochromatic linearly polarized photon beams below particle separation thresholds. It is based on the average branching of decays of 𝐽=1 states of an even-even nucleus to the 2$^{+}_{1}$ state in comparison to the ground state. Between 5 and 7 MeV, a constant average branching ratio for 𝛾 decays from 1 − states of 0.490(16) is observed for the nuclide 150 Nd. Assuming 𝜒 2 -distributed partial transition widths, this average branching ratio is related to a degree of freedom of 𝜈 = 1.93⁢(12), rejecting the validity of the Porter-Thomas distribution, requiring 𝜈 = 1. The observed deviation can be explained by nonstatistical effects in the 𝛾-decay behavior with contributions in the range of 9.4(10)% up to 94(10)%.

150 ≤ A ≤ 189

Ab initio prediction of FeCr sigma (001)/FCC Fe(111) interfacial energy: Effect of interfacial doping of C, B, and N

Interfacial energy plays a crucial role for high-temperature material systems in determining their microstructure evolution and mechanical properties. Optimizing the interfacial energy through doping can improve the stability, performance, and overall functionality of these materials. Here, the present study delivers theoretical investigation on the sigma FeCr (001)//FCC Fe (111) interfacial energy using ab initio methods, focusing on the implications of interfacial doping with important interstitial elements carbon (C), boron (B), and nitrogen (N). The calculated interfacial energy without doping is 0.183J/m 2 . Upon doping, notable reductions in interfacial energy were observed. Doping with B decreased the interfacial energy to 0.046J/m 2 , with single C doping to 0.126J/m 2 , with two C doping to 0.098J/m 2 , and with a single N doping to 0.071J/m 2 . These findings not only shed light on the atomistic origin for the effect of stabilizing the microstructure of stainless steel at elevated temperatures by interstitial doping, but also present a systematic, thorough ab initio approach to predict interfacial doping properties and guide alloy design to enhance the performance and stability.

FeCr sigma phase

Gallium oxide (Ga2O3) as a radiation detector distinguishing neutrons and gammas

Gallium oxide (Ga2O3) is a promising ultrawide bandgap semiconductor for radiation detection with the potential of integrating electronic and scintillation functions within a single crystal device. This study establishes the scintillation response of β-Ga2O3 gamma irradiation from yttrium-88 (88Y). Then, californium-252 (252Cf) is used as a spontaneous fission source of mixed neutron and gamma radiation field to measure scintillation signals. Pulse shape discrimination and constant fraction discrimination techniques were used to separate neutron and gamma interaction events. Further investigation indicates that the prompt temporal responses of β-Ga2O3 for gammas and neutrons may enable discrimination of the two by prompt pulse fitting methods, focused around the initial peak. For gamma irradiation, we observed a rise time (τr) of 2.1 ns, decay time (τd) of 9.5 ns, and a full width at half maximum (FWHM) of 6.2 ns. For neutrons, it showed a τr of 2.3 ns, a τd of 12.1 ns, 9.4 ns FWHM, and reduced peak intensity. A diamond detector exhibited a more symmetrical τr and τd for both gamma and neutron signals and therefore is less effective at discriminating between the two by this method. This draws attention to β-Ga2O3’s ability to distinguish neutron and gamma particles. These findings showcase Ga2O3’s potential as a next-generation semiconductor for applications in nuclear safety and medical imaging, where precise discrimination between neutron and gamma interactions is essential.

Valdes, D. J. (ORCID:0000000304373720)

Clustering and Cliques in Preferential Attachment Random Graphs with Edge Insertion

In this paper, we investigate the global clustering coefficient (a.k.a transitivity) and clique number of graphs generated by a preferential attachment random graph model with an additional feature of allowing edge connections between existing vertices. Specifically, at each time step t, either a new vertex is added with probability f(t), or an edge is added between two existing vertices with probability 1 – f(t). We establish concentration inequalities for the global clustering and clique number of the resulting graphs under the assumption that f(t) is a regularly varying function at infinity with index of regular variation –$\gamma$, where $\gamma$ $\in$ [0, 1). Finally, we also demonstrate an inverse relation between these two statistics: the clique number is essentially the reciprocal of the global clustering coefficient.

97 MATHEMATICS AND COMPUTING

Compact in-vacuum gamma-ray spectrometer for high-repetition rate PW-class laser–matter interaction

With the advent of high repetition rate laser facilities, novel diagnostic tools compatible with these advanced specifications are required. This paper presents the design of an active gamma-ray spectrometer intended for these high repetition rate experiments, with particular emphasis on functionality within a PW level laser-plasma interaction chamber’s extreme conditions. The spectrometer uses stacked scintillators to accommodate a broad range of gamma-ray energies, demonstrating its adaptability for various experimental setups. In addition, it has been engineered to maintain compactness, electromagnetic pulse resistance, and ISO-5 cleanliness requirements while ensuring high sensitivity. The spectrometer has been tested in real conditions inside the PW-class level interaction chamber at the BELLA center, LBNL. The paper further details the calibration process, which utilizes a 60 Co radioactive source, and describes the unfolding technique implemented through a stochastic minimization method.

47 OTHER INSTRUMENTATION

GADRAS-DRF Enhancements for Safeguards – Custom Peak Fitting to Enhance Model Fitting and Isotopics

One major software update was accomplished within the Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF) package. This update allows users to adjust individual peak fits for use in subsequent analysis processes within GADRAS-DRF. A graphical user interface (GUI) was implemented so users can see the effect of their fit adjustments on the spectrum. This new feature will enhance the capability of the previously funded auto-enrichment and peak-based 1D model fit feature that was implemented in FY23 (Fiscal Year). Isotopic analysis was performed using M400 data obtained from uranium standards and the isotopic assessment is given with and without manual peak adjustments.

07 ISOTOPE AND RADIATION SOURCES

GADRAS-DRF Validation for Safeguards and Custom Peak Fit Enhancements

In previous years, SGTech funded enhancements to the isotopics routine in the software called Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF), including the addition of peak fit customization capabilities. A project was also funded that focused on implementing a peak-based model fitting routine, allowing model fitting to be performed without dependence on export-controlled cross-sections. In FY25 significant improvements were made to the custom peak fitting interface, accompanied by several validation studies within GADRAS-DRF. These studies encompassed IsotopeID performance, distributed source analysis, isotopics validation, and activity estimation. Additionally, the peak-only model fitting option was validated using an HPGe measurement of a rotating drum with line sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Indium Tin-Doped Oxide Interactions with Solvent Radiolysis Products

Transparent conductive oxides (TCOs), such as indium tin-doped oxide (ITO), are ubiquitous as components of electronics and are ideal electrode substrates for catalysis, energy transformation reactions, and energy storage applications. Recently, researchers have recognized their effectiveness as electrode materials for manipulating actinide oxidation states in solution. Despite their popularity as electrode materials, prior studies focused extensively on the direct radiolysis of TCO materials in air and rarely examined these effects within a solution, limiting our fundamental understanding of the interactions between solvent radiolysis products and these substrates in high radiation environments. Here, in this study, we characterize the effects of solvent radiolysis products—arising from the gamma irradiation of water, aqueous nitric acid solutions, and n-dodecane—on the composition, surface speciation, and band structure of ITO thin films on a glass substrate as a function of absorbed dose using UV-visible spectroscopy, scanning electron microscopy, photoelectrochemistry, and X-ray photoelectron spectroscopy. Our work demonstrates that mesoporous thin film electrodes of ITO exposed to gamma radiation in each solvent accumulate defects and exhibit solvent and dose dependent changes to their surface and interfacial properties. These electrodes maintain their electrochemical function and improve their photoelectrochemical performance up to at least 100 kGy of accumulated gamma dose, confirming their utility in solvents exposed to ionizing radiation fields.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Forward Modeling of Gamma Reaction History Signatures From Anticipated Deuterium-Tritium Filled MagLIF Implosions on Sandia’s Z-Machine

Nuclear reaction history measurements provide a bang time and burn width of Inertial Confinement Fusion (ICF) implosions and are essential for understanding implosion performance to constrain ICF capsule design. When fusion fuel contains Deuterium (D) and Tritium (T) gas, reaction history is informed by measuring the 16.75 MeV gamma rays generated from the D(T,γ) 5 He reaction. Such DT based reaction history measurements have not been made on the Magnetized Laser Inertial Fusion (MagLIF) platform on Sandia’s Z-Machine due to the lack of Tritium being used. The recent development of ICF implosions with tritiated fuel will open the possibility of measuring the gamma reaction history on the Z-Machine. A forward model of the Gamma Reaction History diagnostic on Z (GRH-Z) has been developed using the MCNP6.3 (Monte-Carlo N-Particle) radiation transport code. The model included the Z-Machine geometry of interest to characterize the impact of neutron induced gamma rays on the DT reaction history measurements. In addition, the impulse response functions of the GRH-Z diagnostic to understand the temporal response of the detector, and the minimum yields required to make a reaction history measurement were calculated. This approach also predicted that with T 2 gas doping of MagLIF implosions a reaction history may be made for high performance shots >8e12-2.4e13 depending on the chosen threshold for the detector, with a maximum signal to background ratio of 25%. It was found that for long duration ICF implosions that additional collimation will be needed to prevent the neutron induced gamma rays from modifying the shape of the measured DT reaction history curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Measurements of a LYSO crystal array from threshold to 100 MeV

We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each 2.5 x 2.5 x 18 cm 3 crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution were measured using low-energy gamma sources. The ten crystals were assembled as an array and subjected to a 30–100 MeV positron beam with excellent momentum definition. The energy and timing resolutions were measured as a function of energy, and the spatial resolution was determined at 70 MeV. An additional measurement using monoenergetic 17.6 MeV gammas produced through a p-Li resonance was later made after the photosensors used in positron testing were improved. Here, as an example of the results, the energy resolution at 70 MeV of (1.52 ± 0.03) % is more than two times better than reported results using previous generation LYSO crystals.

Electromagnetic calorimeter

Thermal aging effects on crosslinked polyethylene cable insulation with decabromodiphenyl ether flame retardant alternative

Decabromodiphenyl ether (decaBDE) has been extensively used as a flame retardant in several applications, including nuclear electrical cable insulation. However, decaBDE has been identified as a persistent, bioaccumulative and toxic (PBT) substance, leading to regulatory scrutiny. The Environmental Protection Agency (EPA) published a regulation on January 6, 2021, aimed at phasing out the manufacturing, processing, and distribution of decaBDE. This rule set a compliance deadline of March 8, 2021, for the manufacture and processing of decaBDE, and an extended deadline of January 6, 2023, for specific applications including wire and cable insulation in nuclear power generation facilities. In response to such regulations, RSCC, a major supplier of safety-related electrical cables and associated products to the U.S. nuclear industry updated the formula of their crosslinked polyethylene (XLPE) insulation to replace the historically used decaBDE flame retardant with an acceptable alternative. This change from the previous decaBDE-containing XLPE prompted interest in comparative performance of the two material formulations, especially with respect to characteristics relevant to safety-related function such as thermal and radiation resistance. RSCC graciously provided samples of wire insulated with the decaBDE-containing XLPE formulation and corresponding wire insulated with XLPE of the new formulation, containing a decaBDE alternative. In this work we compare characteristics of the two formulations and a previously produced commercial version of the RSCC decaBDE-containing XLPE insulation subjected to thermal aging at 150 °C and 165 °C. The comparison was focused on mechanical durability, thermal stability in the oxidative environment, and chemical structures. Briefly, • Tensile elongation at break (EAB) results showed loss of mechanical elasticity with longer aging time, as expected. Aging time dependence of EAB did not differ between the decaBDE-containing and decaBDE-alternative samples. • Subtle differences between the two materials can be detected from Fourier-transform infrared spectroscopy (FTIR) absorbance spectra in the range below 1700 cm -1 , are assumed to be related to decomposition of flame retardant additives during thermal aging. • The oxidation induction time (OIT) data seemed to show that the unaged decaBDE-containing XLPE material is more thermally stable than the unaged decaBDE-alternative material, but the discrepancy in OIT decreased with aging time and the OIT values of the two materials became similar starting with the 4 th day of aging at 165 °C. This thermal aging investigation confirmed that the mechanical durability, a key property monitored for cable qualification, was not significantly affected by the modification of the formulation with a decaBDE alternative flame-retardant system in the investigated thermal aging conditions. Further studies on the same sets of materials exposed to thermal and gamma radiation aging would further inform comparison of the materials safety-related function.

36 MATERIALS SCIENCE

Plasma proteomic biomarkers of physical frailty in heart failure: a propensity score matched discovery-based pilot study

Background: Physical frailty is highly prevalent in heart failure (HF), but we lack an understanding of the underlying pathophysiology. Proteomics evaluation of plasma samples may elucidate potential mechanisms and biomarkers of physical frailty in HF. We aimed to identify plasma proteomic biomarkers that are differentially expressed between physically frail and non physically frail adults with HF. Methods: This was a secondary analysis of a subset of data and plasma samples from a study of frailty among patients with New York Heart Association (NYHA) Functional Classification I-IV HF. Physical frailty was measured using the Frailty Phenotype Criteria. Propensity score matching was used to match pairs of physically frail (n = 20) vs. non-physically frail (n = 20) patients on clinical characteristics. Plasma samples were processed using a sensitive liquid chromatography mass spectrometry platform, utilizing a multiplexed tandem mass tag-labeled quantitative proteomics approach. Differentially expressed proteins were quantified individually using paired t tests with associated log fold change of 0.3 and Fisher’s combined p values. Results: The sample (n = 40) was 62.8±16.9 years old, 58% female, and 55% NYHA Class III/IV. Proteomics analysis revealed 7 proteins differentially expressed using full differential criteria: matrix metalloproteinase-14 was downregulated in frailty, and copine-1, low affinity immunoglobulin gamma Fc region receptor III-A and III-B, probable non-functional immunoglobulin kappa variable 2D-24, glutathione S-transferase Mu 1, and argininosuccinate lyase were upregulated in frailty. Conclusions: Proteomic biomarkers related to the immune system, stress response, and detoxification were differentially expressed between physically frail and non-physically frail adults with HF.

Biomarkers

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Identification and time evolution of thionyl chloride (SOCl 2 ) radiolysis products

In this study, innovative solutions are needed to reduce the amount of high-level waste generated by used nuclear fuel recycling strategies to support the widespread adoption of sustainable nuclear fission energy technologies. To this end, a new sulfur chloride-based process has been developed to recycle zirconium alloy-based materials, which make up a significant fraction of high-level radioactive waste. To support the continued development of this process, we present new data on the potential reaction pathways over time of the products arising from the gamma and electron beam radiolysis of neat thionyl chloride (SOCl 2 ). Interrogation of the gamma irradiated liquid by Raman spectroscopy provided more conclusive identification of the SOCl 2 degradation products, specifically sulfur dichloride (SCl 2 ), molecular chlorine (Cl 2 ), sulfur dioxide (SO 2 ), and sulfuryl chloride (SO 2 Cl 2 ). In comparison, the high dose rate (~10 7 Gy s -1 ) electron beam irradiations formed significantly more degradation products. For both cobalt-60 gamma and electron beam irradiations, the observed degradation products were found to evolve as a function of time post-irradiation via the same reaction pathways, with indication of a solvent regeneration mechanism. These findings are fortuitous for process development, as such a mechanism would be beneficial for process longevity and cost effectiveness.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA

Inferring fusion nuclear burnwidths with low gain photomultiplier impulse response functions

When an inertial confinement fusion implosion is compressed, it maintains thermonuclear density and temperatures for a very short time scale, about 100 ps. The Gamma Reaction History diagnostic measures the time evolution of the fusion burn, but its temporal resolution is limited by the use of a photomultiplier tube (PMT) to amplify the photon signal. Multichannel plate-based PMTs have a fast (~120 ps) full-width at half-max impulse response function (IRF), but the time scale is similar to the incoming physics signal. An analysis routine is used to remove the effect of the PMT IRF and infer the incident fusion burnwidth. With the National Ignition Facility achieving ignition and creating much brighter signals, the PMTs are run at gains three orders of magnitude lower than nominal operation. Calibration at these settings shows the PMT IRFs get ~15% wider. Taking the gain-dependent IRF can affect the inferred nuclear burnwidths by up to ~15%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Transverse single-spin asymmetries in $γ$ SIDIS as a direct probe of quark-gluon-quark longitudinal momentum structure

Transverse single-spin asymmetries in the semi-inclusive deep-inelastic production of isolated photons ($\gamma$SIDIS), $A_{UT}^{\gamma {\rm SIDIS}}$, provide an unprecedented opportunity to extract the quark-gluon-quark correlators $F_{FT}(x,x')$ and $G_{FT}(x,x')$ point-by-point in their full support $x,x'$. We utilize realistic models for these functions, based on input from the Sivers transverse momentum dependent parton distribution function and imposing constraints from the $d_2$ matrix element calculated in lattice QCD, in order to provide numerical estimates for $A_{UT}^{\gamma {\rm SIDIS}}$ at the Electron-Ion Collider (EIC). We thoroughly explore the EIC phase space in order to isolate in which regions the asymmetry can be sizable, finding it can be as much as $10\%$ or larger for certain kinematics. Given that $F_{FT}(x,x')$ and $G_{FT}(x,x')$ are basically unknown, $A_{UT}^{\gamma {\rm SIDIS}}$ will be an important future measurement to learn about multi-parton correlations in the nucleon.

Electron-Ion Collider